Gates automation. Summary  Choosing the appropriate model  Faac Product Range (Sliding Gates)

Slides:



Advertisements
Similar presentations
COMPOBAT WE WILL BUILD YOUR BATTERY-CHARGING FACILITY TAILOR-MADE SOLUTIONS FOR HANDLING YOUR BATTERIES.
Advertisements

Installation of. Congratulations for choose this GSM car alarm system for your car. Taking a few minutes to watch this Installation Guide and read the.
First Paper Feed Area Table Height Adjustment: There are two ways of adjusting the upper limit sensor. 1. You can put two sheets of paper on the paper.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Feasibility Study of Replacing an Industrial Hydraulic Lift System with an Electro-Mechanical Lift System Critical Design Review Thursday, 21 September.
Purpose Body Making module is designed for bending the laminated foil film in the shape of a tube, for welding the side seam and for cutting bodies with.
Service Engineering Synchronizer Maintenance. Service Engineering Synchronizer: What is it? The Synchronizer is a device that helps match engine speed.
Installation. Indoor Unit Installation Typical Installation.
How to carry out experiments using MPMS March 2012 Takeshi NAKAGAWA.
Project 2000 University Product Training
HIE-ISOLDE HEBT: characteristics Beamline diameter: 40 mm (REX: 100 mm) Beamline height: 1.75 m Beamline vacuum: low 1e-7- high 1e-8 mbar Connection of.
COPYRIGHT SILCA SpA 2005 Silca is a member of the Kaba Group.
OSHA Subpart Q Concrete and Masonry Construction.
for swing-leaf gate operators
Steering Columns.
General idea of a couple of check rod system and adjustments
Installation. Indoor Unit Installation Typical Installation.
AccuMax Multi-Point Injection Mechanics
A Preliminary Design of the Rotator for the DES Simulator Stand February 28, 2008 Edward Chi Fermilab/PPD/MD.
Usage Guidelines Throughout this template you will find tip-boxes to the left of the slides. To remove this box from the final presentation, simply click.
EGD ELECTRICAL ELECTRICAL SYMBOLS.
The machine is built to comply with the accident prevention, hygiene and electric standards in force. MODUL SERIES MODULAR DECK OVENS Control panel features:
Parking systems & Access Control Bologna October 13, 2011 FAAC J 355 HA M30-P1 crash rated bollard.
STARTING SYSTEM.
INTRODUCTION OF BTI PRODUCTS STRATEGY ON SELLING BTI This presentation is designed to : Aid you in selling BTI products Understanding the advantages.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of Interlogix Europe & Africa.
FAAC Bollard Range March
Installation. Indoor Unit Installation Typical Installation.
Gates automation. Summary  Choosing the appropriate model  Faac Product Range (Swing gates)  Faac Product Range (Sliding Gates)
GEARMOTORS FOR INDUSTRIAL SECTIONAL DOORS GEARMOTORS FOR INDUSTRIAL SECTIONAL DOORS.
NEW SLIDING DOOR OPERATOR SERIES A140 AIR
S800H Hybrid Operator. Summary  S700H bug fixing  New S800H  Lever manual release  Hydraulic manual release.
MKT May 2012 C850: Fast sliding gate operator. MKT May 2012 Summary  Why a fast slider operator?  USPs  Applications  Details  Technical specifications.
Flat Saw Training. Flat Saw Sizes –Low Horsepower Blade diameters range from 8” (200mm) to 18” (450mm) Power ranges from 4 to 25 horsepower.
My working experience Marco Villa Tue, 2 nd Dec 2008.
RADIATION SOURCE Design Review Dmitry Gudkov BE-BI-ML.
24V DC - Swing gate automation with articulated arm 391.
Lower Structure Revised Catcher. Catcher Mechanism The lever arm is adjusted so that the clamp is at its full height above the mass. An Allen key is.
New sliding gates gearmotor C721 (24 Vdc). Summary  Why a new 24Vdc operator?  USPs  Technical specifications.
MECVEL SIGNS THE “SLIDING DOORS” REMAKE: SLIDING DOORS ONLY WITH OUR LINEAR ACTUATORS!
Target Commissioning Target installed in ISIS “Demonstrator” target in R78 Initial commissioning plans Chris Booth Sheffield 11 th February 2008.
VCBs are well protected with interlocking switches for its switching device operation with busbar. Switching devices in VCBs have to be disabled or enable.
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
Swing gate automation with articulated arm
Garage Doors Operators 24V DC D600 – D1000. WHY? To have a product able to compete with market leaders by design and functionality Garage doors operators.
Motor bike- Clutch working GROUP-I RAJUKUMAR HARSHATH JOSHUA DANIEL BHASKER SANTHOSH.
New hydraulic 24V swing-leaf gates operator S450H FAAC International Workshop 2009 Rimini, Italy September 2009 by SAT.
New sliding gates gearmotor C720 24V. Summary  Why a 24V operator?  USPs  Technical specifications.
IOPtiMate™ OT-135P2 Technical Training – Part I System Description, Installation & Operation IOP (07)
Automotive Differential
Different cable reel has a different role. Hysteresis type cable reel working principle and scope The working principle of A. Power control system is.
Automation and Drives A&D SD Customer Service & Support A&D SD CST 20/11/04 1 of 13 10A Control Board Exchange.ppt Introduction Procedure Setting up Exchanging.
The Quality Control Company Quanti TM product series “Simplicity is the ultimate sophistication” - Leonardo da Vinci.
CML 700i measuring light curtains Integrated interfaces and control unit for even simpler operation Leuze electronic | CML 700i product launch | Status:
Control and signalling Harmony Easy XA2E Ø 22 mm, plastic push-buttons, switches with metallic-look ring Introducing the Easy line Essential automation.
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
Select your System Freedom Micro DI.
Drive systems for livestock
Machine Guarding OSHA 29 CFR
Gates automation 1.
SuperQuest Salem Arms – Best Practices.
Microwave Motion Activator I (Automatic Door Sensor)
Clarkson University Electric Knights E54
Programming Concepts (Part B) ENGR 10 Introduction to Engineering
Korea University of Technology and Education
Universal Parallel Gripper
1.11: Robot Controller.
Dupont or Metal worn gear (optional)
Chapter 7: Classroom and shop manuals
Presentation transcript:

Gates automation

Summary  Choosing the appropriate model  Faac Product Range (Sliding Gates)

Choosing the appropriate model The status of the gate structure has a direct influence on the automation safety and reliability The gate structure must be suitable for automation. The following are necessary in particular: wheel diameter must be in proportion to the weight of the gate to be automated, an upper guide must be provided, plus mechanical stop limits to prevent the gate derailing. The soil must permit sufficient stability for the foundation plinth. There must be no pipes or electric cables in the plinth excavation area. If the gearmotor is exposed to passing vehicles, install, if possible, adequate means of protection against accidental impact. Check if an efficient earthing is available for connection to the gearmotor. The mechanical travel limit presence is mandatory

Choosing the appropriate model It is good to comply with customer requests if technically possible, otherwise it is advisable to suggest the most suitable technical solution You must choose the operator based on: - the application type (residential, condominial, industrial) - weight of the sliding gate - length of the sliding gate (15 m maximum) - In case, suggest the customer to use double sliding gate - always check that the operator complies with the requested duty cycle

Installation Prepare a foundation plinth and wall the foundation plate, supplying one or more sheaths for routing electric cables. Using a spirit level, check if the plate is perfectly leveled. Wait for the cement to set.

Installation Lay the electric cables for connection to the accessories and power supply To make the connections efficiently, allow the cables to project by about 40 cm from the hole of the foundation plate.

Installation Fix mechanically the operator using the supplied side brackets. Adjust the operator height according to the manual specs

Installation Position the nylon rack or the chain, depending on you installation specifications

Installation Make sure that there is always some space between the pinion and the rack (at least 1,5 / 2 mm). If the rack you are using has slots instead of holes for the fixing, place the screw on the top position. This will be useful in the future when the gate settling will need a rack position adjustment: the gate will lower, and you will have space to raise the rack.

Summary  Choosing the appropriate model  Faac Product Range (Sliding Gates)

740/1 Maximum gate weight: 500 kgs (740) / 900 kgs (741) Only available with Z16 pinion Quick and easy installation thanks to the built-in, prewired control unit. Anti-crushing protection is ensured by an electronic device directly controlling drive torque. As the gearmotor is non reversing, no electric locks need to be installed. In the event of power failure, the rotation of the key protected release device makes it possible to open and close the gate manually. Simplifed “on display” programming. Magnetic limit switch.

740/1 Rated duty cycle is 30% (740) or 40% (741)

746 ER Maximum gate weight: 600 kgs (Z16 pinion) / 400 kgs (Z20 pinion) Available in CAT (chain transmission) configuration and RF configuration (chain with idle transmission) Maximum anti-crushing safety by coupling the twin-disk oil-bath clutch with the electronic device and encoder. As the gearmotor is non reversing, no electric locks need be installed. Key protected lever release device. Magnetic limit switch device, simplifed installation of limit switch magnets Designed for height and side adjustable fastening. Control board, protected by a housing, for simplifed programming via display.

746 ER Rated duty cycle is 70%

844 ER Maximum gate weight: 1800 kgs (Z16 pinion) – ERZ16 model Available in CAT (chain transmission), RF (chain with idle transmission) and R (without pinion) configurations Ideal for commercial and industrial applications. Anti-crushing safety. As the gearmotor is non reversing, no electric locks need to be installed In the event of power failure, the key-operated release device makes it possible to open and close the gate manually. Twin-disk clutch in oil-bath. Inductive or magnetic limit switch (according to model).

844 ER Rated duty cycle is 70%

Troubleshooting Common problems to be solved -The gate doesn’t move -Motor starts but the gate doesn’t move -The gate is opening 20/40 cm then stops and reverses -The gate can’t reverse -The gate doesn’t open when receiving and OPEN signal -The gate remains opened

Troubleshooting The gate doesn’t move Check that: The electronic board is powered The capacitor is correctly connected between the two motor phases LEDs on the electronic board are correctly lit up The clutch is correctly adjusted The force on the electronic board is correctly setup If the encoder is not present, disable it in the parameters

Troubleshooting The motor starts but the gate doesn’t move Check that: The capacitor is correctly connected between the two motor phases LEDs on the electronic board are correctly lit up The clutch is correctly adjusted The force on the electronic board is correctly setup If the encoder is not present, disable it in the parameters

The gate is opening 20/40 cm then stops and reverses Troubleshooting Check that: The gate doesn’t have any friction over the entire route The encoder sensitivity is correctly regulated If the encoder is not present, disable it in the parameters The gate can’t reverse its direction Check the clutch regulation

Troubleshooting The gate doesn’t open when receiving and OPEN signal Check that: LEDs on the electronic board are correctly lit up The whole radio system is correctly connected and setup. When sending and OPEN signal from the remote control, the OP-A should light up.

Troubleshooting The gate remains opened Check that: The closing photocells are not engaged (this happens when FSW-CL is off) There isn’t any OPEN pulse always on