UNIT 31 HOME ELECTRICAL SYSTEM
Advertisements

ADX 150 – Engine Repair ADX 170 – Climate Controls
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Unit 206: Domestic hot water systems
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
Objective of the session.
Screened Warning Pipe A screened water pipe is a requirement under the water regulations. The pipe should be one size larger that the supply pipe.
HVACR312 - Refrigeration Metering Devices.
Unit 206: Domestic hot water systems
Engine Systems and Components
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
EET Survey of Electronics
New Mexico FFA Agricultural Mechanics Career Development Event Plumbing.
PHSAUTOMOTIVESALSPHSAUTOMOTIVESALS Charging System tests & Voltage information Checking the charging system with just a volt meter.
Electrical Power Systems
Residential Wiring Facts
Copyright Area II Plumbers JATC. All Rights Reserved. Repairs, Maintenance, and Installation of Electric Residential Water Heaters 8 Hours of.
Presentation on Installation of a Domestic Cold Water Storage Cistern
USING ELECTRICITY – Class 7 HEATING EFFECTS OF ELECTRICITY Done by Mrs. Aparna.S.
Noadswood Science, 2012 Electrical Safety. Electricity Safety To be able identify safety features with electrical components Tuesday, August 11, 2015.
STEAM HEATING.
Hydronic Mechanical Controls
Current, Conductors and Insulators. Current Current: Current refers to electricity that moves through a circuit.
Screened Warning Pipe A screened water pipe is a requirement under the water regulations. The pipe should be one size larger that the supply pipe.
Pages  In this PowerPoint, write down everything that is RED!!
Practical Electricity
Air Handler Terminology
Vacuum system.
Contributed by: Integrated Teaching and Learning Program, College of Engineering, University of Colorado at Boulder.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Ohm’s Law Conductor A conductor is a material that current can pass through easily, like metals.
Objective Describe materials used in electric wiring.
Section 3 Using Heat.
Thermionic Valves.
Basic Electricity By: Rebecca Garcia. Electricity Electricity is seen around us every day. Electrical outlets are found throughout our house. Lightning.
The Cooling System.
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
The Cooling System (Reasons for)
Water Heaters 101 Residential Gas and Electric. Outline Basic water heater features Residential gas overview Residential electric overview Q&A.
HOT WATER Understand and apply domestic hot water system installation and maintenance techniques.
Electric Wiring Conductor A material that allows electricity to move readily and offers low resistance Example: copper, aluminum and water.
Static vs Current Circuit Elements Resistance is V / I Energy switch Make and use How to generate.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Manoj kumar 2009JE0406 Mining machinery engineering.
Plumbing Valves.
Engine Cooling Systems
Components of Construction part 2
Electrical Principles and Wiring Materials
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Air Distribution Control
Types of Cables.
Electrical Gas Plumbing Heating & Cooling
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Special-Purpose Outlets—Water Pump, Water Heater
Practical electricity
Hot water Systems Heaters.
THERMAL PROPERTIES OF MATTER
Hot Water Systems Cylinders and Systems.
Cisterns and Insulation
Wiring the Light and Relay
By: JAGDEEP SANGWAN Refrigeration Basics 101.
1 INTERNATIONAL MARITIME COLLEGE OMAN PROCESS TECHNOLOGY & SYSTEMS (TPTS & PT-TPTS) PE (TPTS & PT-TPTS) (Chapter-3) Chapter - 3 Distillation Systems Textbook.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Presentation transcript:

Direct Hot Water

What Cold Water System is Pictured? What hot Water System is Pictured?

The cold water storage tank acts as a reservoir; it supplies cold water to the hot water cylinder in the direct hot water system. Newer cold water tanks tend to be sealed to comply with the water regulations. Older open toped tanks may be encountered and these should be rectified to comply with current regulations. Cold Water Storage Tank

Byelaw Kit The byelaw kit contains all of the components to make the CWST comply with the regulations. The kit contains;- Tight fitting lid Part 2 float valve Insulation jacket Screened vent Screened warning pipe

Tank Connector A tank connector is used to connect water pipes to the cold water storage tank. The flanges on the connector provide a large clamping surface; there should be a compressible washer / gasket on the inside of the tank to provide a water proof seal. The other end of the tank connector has a compression fitting or sometimes a pushfit connection.

Hot Water Cylinder The direct hot water cylinder can be identified by the number of ports on the cylinder. There should be two ports for the inlet and outlet; and a heating element port

A B Question What type of hot water cylinder is A? What type of hot water cylinder is B?

Hot Water Cylinder Cold water in at the bottom of a cylinder hot water out from the top of a cylinder The cylinder needs to be insulated to make the cylinder energy efficient and reduce wastage Pipes should be lagged up to 1 meter from the cylinder or until they disappear into the floor or wall.

Emersion Heater An emersion heater is fitted to a hot water cylinder by a threaded connection. The heater has a seal to make the connection waterproof but it is recommended that a jointing compound also be used. The element is fitted using an emersion heater spanner.

Emersion Heater The section of the emersion that is inserted into the hot water cylinder consists of two parts. The element Is made from a resistive wire that is insulated and sealed in a copper tube, when and electrical current is passed through the wire it heats up warming the surrounding water. The thermostat Is wired in series to the element, when the water reaches the required temperature the thermostat turns the power off. As the water cools the thermostat registers the temperature drop and turns the power back on.

The emersion heater element has a protective metal cover; to remove this undo the retaining nut. Inside the cover you will see the; Neutral terminal. Thermostat Thermal cut out switch. Live terminal of heating element. Emersion Heater Connections

The live wire is connected to the terminal in the thermostat. The power is then connected by the white wire to the thermal cut out switch. From the thermal cut out switch the power goes to the live terminal of the heating element. The circuit is completed by the neutral cable connected to the neutral terminal. Emersion Heater Connections

The thermostat controls the temperature of the water; It does this by turning off the power to the element when the water is at the required temperature and turning the power back on when the water temperature drops below what it has been set to. The temperature of the water is adjusted by turning the control knob. NB this thermostat has a built in thermal cut out switch; this switches the power off if the temperature gets too high and has to be manually reset before the heating element will start working again. Thermostat

Switch Spur Emersion heaters use a large amount of power; as a result they should have there own switched spur. The switched spur should be a two pole switch normally fitted with an indicator light to shop the circuit is energized. The cable leading from the switch to the immersion heater should be flexible and heat resistant.

The cable connecting the emersion heater to the switch must be heat resistant. It should be rated at least 85°C. Heat resistant cable should be used where ambient temperatures exceed the working range of standard PVC cables which is +5ºC to 70ºC. Heat resistant cables are usually made from butyl. There should be no longer than 1m of flex from the two pole switch to the immersion heater. Switch Spur Cable

Two-Pole Switch The switch for an emersion heater is two pole; this means that both the live and the neutral is switched. Two pole switches are safer as they isolate both of the conductors. Some switches have an indicator light to show there is power to the circuit.

Stratification Stratification is the phenomenon of water of different temperatures forming into strata or ‘layers’. The lower layers are the coldest whilst the highest layers are the hottest. Stratification