Jae Lim Chung MD, MBA 1,3 ; Jin Pyo Hong MD 2,3 ; Kyoung Yul Seo MD, PhD 3 ; Eung Kweon Kim MD, PhD 3 ; Tae-im Kim MD, PhD 3 1 1 Noo Ne Eye Hospital, Seoul,

Slides:



Advertisements
Similar presentations
Comparison of Visual Outcomes With Toric IOL and With Limbal Relaxing Incisions in Cataract Surgery Eriko Fukuyama, MD Fukuyama Eye Clinic Fukuoka, Japan.
Advertisements

Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
Intraoperative Aberrometry Mark Packer, MD, FACS Clinical Associate Professor Oregon Health & Sciences University.
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
A simple and accurate method of alignment for toric intraocular lens implantation using anterior segment optical coherence tomography (OCT). Kazuno Negishi,
Correlation Of Corneal Contour With Higher Order Ocular Aberrations (HOA) In Indian Eyes Manish Chaudhary MS Amit Gupta MS Advanced Eye Centre, Postgraduate.
Long-Term Follow-Up of Toric Intraocular Lens Implantation for Keratoconus Alejandro Navas, MD, MSc, Martha Jaimes, MD, Jesús Cabral, MD, Arturo Ramirez.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
INTRAOPERATIVE FLAP COMPLICATIONS IN LASIK SURGERY PERFORMED BY OPHTHALMOLOGY RESIDENTS IN TRAINING Arturo Gómez-Bastar MD Arturo Ramirez-MirandaMD Lorena.
Placement of Toric Intraocular Lens and the Long-term Change in the Axis of Corneal Astigmatism after Sutureless Cataract Extraction by Phacoemulsification.
David Zadok MD, Isaac Avni MD
Managing the Refractive “Surprise” After Toric IOL Placement Managing the Refractive “Surprise” After Toric IOL Placement Brad H Feldman, MD Derek DelMonte,
Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz.
So-Hyang Chung, MD, PhD, Choun-Ki Joo, MD, PhD Department of Ophthalmology and Visual Science, College of Medicine, The Catholic University of Korea, Seoul,
Hyun Seung Kim, M.D. Department of Ophthalmology, St. Mary’s hospital, The Catholic University of Korea Changes in Astigmatism After Clear Corneal Temporal.
Changes of Presenile Cataracts that had been Operated over 10 years in Korea Sung Kun Chung, M.D. ; Eun-Jung Jun, M.D. Hyun Seung Kim. Department of Ophthalmology.
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
Nizar S Abdelfattah, M.D.1, Marina Israel2, Nermin Osman, M.D.3,
G. Jacob 1,2, C. Bouchard 2, S. Kancherla 1. Edward Hines, Jr. VA Hospital, Hines, IL, Department of Ophthalmology 1. Loyola University Medical Center,
Comparison of Orbscan and Ultrasound Pachymetry Measurements Faik Orucov, MD, Abraham Solomon, MD,Ziv Caspi, David Landau, MD, Eyal Strassman, MD, and.
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
Effects of IOP Lowering Agents on Myopic Regression after Refractive Surgery Lim, Taehyung M.D., Hong, So Jin M.D., Cho, Beom Jin M.D., Ph.D. Chung Kyu-Hyung.
Evaluation of Interface Reflectivity and Corneal Aberrations following DSAEK Hamid Khakshoor, MD Professor of Ophthalmology Mashhad University of Medical.
Hong Kong Eye Hospital Ms Frenchy Chiu Dr Victoria Wong IOL master
The Differences of Depth Parameters of Deposits Depending on the Morphology in Granular Corneal Dystrophy Type Ⅱ by Fourier Domain Optical Coherence Tomography.
Occurrence of Retinal Detachment After Cataract Surgery Peter Jeppesen MD, PhD and Thomas K. Olsen, MD, DMSc Department of Ophthalmology Århus University.
Evaluation of Zonal Equivalent Keratometry Readings After LASIK Timmy Kovoor, MD Orkun Muftuoglu, MD V.Vinod Mootha, MD Steven Verity, MD R. Wayne Bowman,
The authors have no financial interest in the subject matter of this poster Yinfei Xu, Peter S. Hersh, MD, David S. Chu, MD Institutional Affiliations.
ROTATING SCHEIMPFLUG TOPOGRAPHIC PARAMETERS IMPORTANT IN DISTINGUISHING NORMAL FROM KERATOCONIC CORNEAL MORPHOLOGICAL FEATURES Clayton Falknor, MD, Orkun.
Astigmatism management with toric intraocular lenses in cataract patients Adriano Guarnieri 1-2, Luis W. Lu 3-4, Alfonso Arias- Puente INCIVI, Madrid,
Sonia Yoo, MD 1 Fernanda Piccoli, MD 1 Artur Schmitt, MD 1 Takeshi Ide, MD 1 Tsontcho Ianchulev, MD 2 Authors have no financial interest in this subject.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Khairidzan Mohd Kamal MD
ELEVATION AND PACHYMETRY VALUES IN NORMAL CORNEAS OBTAINED BY GALILEI ASCRS Boston April Vision Sana Research Group Vision Sana Research Group.
M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD, L. Wagnerova MD D. Sivekova MD, L. Wagnerova MD Prof. P. Kuchynka MD, PhD Prof. P. Kuchynka MD, PhD The.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Mean Keratometry Measurement Post Penetrating Keratoplasty Jacky Yeung MSc MD, Stephanie Baxter MD FRCS(C) Department of Ophthalmology, Hotel Dieu Hospital,
Partial Coherence Interferometry Failure Rate in a Teaching Hospital Leslie A. Wei 1,2, BA, Nickolaus P. Katsoulakis 2, MD, Theodoros Filippopoulos 3,
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
Nang-Hee Song(MD) 1, Jae-Woong Koh (MD/PhD) 1, Gil-Joong Yoon (MD/PhD) 2 Department of Ophthalmology, Chosun University College of Medicine, Gwangju, Republic.
1 P.O. dei Pellegrini; A.S.L. Napoli 1Centro 2 Dipartimento di Oftalmologia, Seconda Università degli Studi Napoli Scheimpflug topography, Scanning-Slit.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
Futoshi Taketani, MD,PhD,
Sherman W. Reeves, MD, MPH 1,3,4 ; Jacob A. Kozisek, OD 1,2 ; Noumia Cloutier-Gill, OD 1,2 ; David R. Hardten, MD 1,2,3,4 Accuracy of Scheimpflug Imaging.
LogMAR-Analysis of multifocal intraocular lenses: Clinical performance A. Mannsfeld, I.-J. Limberger, A. Ehmer, M.P. Holzer, G. U.Auffarth International.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Risk Factor Analysis of Topographic Progression in Keratoconus Seong Joon Ahn, MD 1,2, Mee Kum Kim MD, PhD 1,2, Won Ryang Wee, MD, PhD 1,2 1 Department.
Hongseok Yang, M.D. Dae Hee Kim, M.D. Department of Ophthalmology, Ajou University School of medicine, Suwon, Korea The authors have no financial interest.
Inadvertent Insertion of an Opposite- Side Tecnis ZM900 Multifocal IOL Wilson Takashi Hida, M.D. Celso Takashi Nakano; Jonathan Lake;
Simulated Experiments on IOL Power Calculation Using Anterior Segment OCT Dong Hyun Jo, M.D., 1,2 Mee Kum Kim, M.D., 1,2 Won Ryang Wee, M.D. 1,2 1 Department.
Corneal shape and corneal aberrations after MicroIncision Cataract Surgery (MICS) NOCHEZ Y, BUREL B, MAJZOUB S, PISELLA PJ C.H.U.
The results of PTK using Fourier-Domain Optical Coherence Tomography for Granular Corneal Dystrophy Type 2 Eung Kweon Kim, MD, Ph.D 1 ; Tae-im Kim, MD,
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
Intraocular Lens Outcomes: Comparison of Technologies and Formulas Carolina Eyecare Physicians, LLC Research Assistant Professor of Ophthalmology Storm.
Department of Ophthalmology, University of Ulsan College of Medicine,
Suppressive effect of combined treatment of orthokeratology and 0
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Outcome of LASIK in Pre-Descemet’s Membrane Corneal Dystrophy
Hôpital Ophtalmique Universitaire
Comparison of Central Corneal Thickness measured by
MP Weikert, M Shirayama, L Wang, DD Koch
Comparison of corneal powers obtained from four different devices
Authors have no financial interest in any product mentioned herein
Comparison of Autokeratometry and Manual Keratometry
The authors have no financial interest
Sun Woong Kim, M.D.1, Hae Jung Sun, M.D.1,
versus 2.75mm Incision Phacoemulsification
성모병원 안센터 CHANGES IN ASTIGMATISM RELATIVE TO IOL HAPTIC INSERTION AXIS IN WITH-THE-RULE AND AGAINST-THE-RULE ASTIGMATISM PATIENTS Hyun Seung Kim, M.D.
Peter Lee MD, Howard Gimbel MD, Maria Ferensowicz MA
Michael Goodman, Alexandra Paul and Andrew Hsu
Presentation transcript:

Jae Lim Chung MD, MBA 1,3 ; Jin Pyo Hong MD 2,3 ; Kyoung Yul Seo MD, PhD 3 ; Eung Kweon Kim MD, PhD 3 ; Tae-im Kim MD, PhD Noo Ne Eye Hospital, Seoul, Korea 2 2 Sae Yan Eye Clinic, Seoul, Korea 3 3 Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea. None of the authors have any commercial or financial interests

 For Successful Outcome Of Toric IOL  Precise Measurement Of Preoperative Corneal Astigmatism  Crucial Point !  To Determine Accuracy & Correlation of 6 Different Keratometers & Topographers 2

 Shin-Nippon Co, Ltd, Japan  Measuring capacity Corneal Radius of Curvature ○ 6.50 ~ 9.40 mm Corneal Keratometric Power ○ 36 ~ 52 D Axis Corneal Astigmatism ○ 0 ~ 180° 3

 Canon, Japan  Measuring capacity Corneal Radius of Curvature ○ 5.5 ~ 10 mm Corneal Refractive Power ○ ~ D Axis Corneal Astigmatism ○ 0 ~ 180° 4

Carl Zeiss Meditec, Germany 2.5 mm measurement diameter Cf. Manual keratometers ~ 3 mm 30 data points per measurement 6 spots x 5 samples 5 images automatically captured in 0.5 sec Displayed result is average of 5 captured images 5

6  Bausch & Lomb, USA  Topography-based  Simulated K-readings (=Sim K’s) c Axis  3 & 5 mm zone statistics Average & SD of Mean & Astigmatic Power Steep & Flat Axis

 Oculus, Germany  Scheimpflug image-based Topographic analysis of Corneal Astigmatism 7

 Tracey Technologies, USA  Dual Acquisition Unit EysSys Corneal Topographer ○ Placido ring-based Wavefront analyzer 8

 Study Population Preoperative visit for Cataract Surgery 257 eyes of 141 patients ○ Age : 54.5 ± 20.5 yrs ○ Sex : Male - 54, Female - 87  Manual Keratometric Measurement Duplicated examination by 2 skillful examiners Considered as Standard  Compared with 5 other Keratometers 9

 Pearson Correlation analysis Between Manual Keratometery Vs Other Methods 10 Vs. Manual Keratometer Pearson Correlation Coefficient iTrace0.947 ORBscan0.921 AutoKeratometer0.919 IOL master0.857 Pentacam0.847

 Pearson Correlation analysis Between Manual Keratometery Vs Other Methods 11 Vs. Manual Keratometer Pearson Correlation Coefficient iTrace0.856 AutoKeratometer0.852 IOL master0.751 ORBscan0.646 Pentacam0.633

 Duplicated Manual Keratometric Measurements By 2 Experienced Operators Taken As Standard  iTrace Approximated This Standard The Most  Auto Keratometer, ORB & IOL Master Showed To Be Reasonably Accurate.  Trend For ORB Fail To Read Accurately In Steep Axis 12