CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.

Slides:



Advertisements
Similar presentations
Cable Testing.
Advertisements

1 Alien Crosstalk for the Inexperienced User.
CCNA 1 v3.1 Module 4 Cable Testing. Purpose of This PowerPoint This PowerPoint primarily consists of the Target Indicators (TIs) of this module in CCNA.
111 © 2002, Cisco Systems, Inc. All rights reserved. Finish Phase Overview Testing Troubleshooting Certification Documentation.
Category 6 Solutions Category 6 Solutions. Intent Category 6 Cabling Where it came from What it is Why you need it How you use it.
Testing.
Physical Transmission Media 8 5/9/ Modified by: Brierley.
Pursuit of Better testing Instrument Let's go in the grandway......
Infrastructure and components. Cable The cable and components used in structured cabling systems is defined in the standards –EIA/TIA 568 x There are.
1 Telecom Cabling Testing and cable certification.
Optical Fiber Testing Paul Minko EE 566 Oct. 22, 2003.
Oct-03 ©Cisco Systems CCNA Semester 1 Version 3 Comp11 Mod4 – St. Lawrence College – Cornwall Campus, ON, Canada – Clark slide 1 Cisco Systems CCNA Version.
Physical Media Now that we’ve been over how to encode data as signals, what are the physical media that carry these signals?
NETWORK DESIGN Customer requirements Network topologies Cable choice Hardware TSB 75 TSB72.
Measuring Frequency The amplitude of an electrical signal represents height and is measured in volts. The period is the amount of time to complete one.
TESTING MULTIMODE FIBER
Testing Optical Fiber Links
1 Fiber Optic Measurement Technique Piotr Turowicz Poznan Supercomputing and Networking Center Training Session Kiev 9-10 October.
Copyright CCNA 1 Chapter 6, Part 1 Ethernet Technologies By Your Name.
Copyright CCNA 1 Chapter 4, Part 1 Cable Testing By Your Name.
CCNA 1 v3.0 Module 4 Cable Testing. Purpose of This PowerPoint This PowerPoint primarily consists of the Target Indicators (TIs) of this module in CCNA.
CSE 550 Computer Network Design Dr. Mohammed H. Sqalli COE, KFUPM Spring 2007 (Term 062)
Installation and testing
1 Guide to Network Cabling Fundamentals Chapter 8.
4 Semester 1 CHAPTER 4 REVIEW JEOPARDY Presented by: Terren L. Bichard.
CCNA 1 Module 4: Cable Testing.
1 Semester 1 Module 4 Cable Testing Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
Fiber Optics LINK LOSS BUDGET.
` April 28, 2004 When Gigabit Ethernet (1000BaseT as specified by IEEE 802.3ab) was developed utilizing all four pairs simultaneously and bi-directionally.
Page 1 © 2008 IDEAL INDUSTRIES IDEAL Micro OTDR Oktober 2008 Konstantin Hüdepohl.
1 CCNA SEMESTER 1 V 3.0 CHAPTER 4 – Cable testing.
NESCOT CATC1 Cable Testing CCNA 1 v3 – Module 4. NESCOT CATC2 Waves 1. The _________ of the waves is the amount of time between each wave, measured in.
1 CISCO NETWORKING ACADEMY PROGRAM (CNAP) SEMESTER 1/ MODULE 4 Cable Testing.
Optical Fiber Connections joints and couplers
Component 9 – Networking and Health Information Exchange Unit 2-2 Network Media and Hardware Communication Devices This material was developed by Duke.
Signamax Structured Cabling Seminar. INTRODUCTION.
HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.
O ptical R eturn L oss testing using KI 7340 series Loss Tester Kingfisher International PTY LTD V
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Advantages of the One-Jumper Reference Method 15 July The Advantages of the One-Jumper Reference Method Over the Two-Jumper Reference Method when.
CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.
CABLING SYSTEM BACKBONE SUBSYSTEM.
ANSI/TIA-568-C Generic Telecommunications Cabling APPROVED: FEBRUARY 2, 2009 This template can be used as a starter file for presenting training.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
Networking and Health Information Exchange Unit 2b Network Media and Hardware Communication Devices Component 9/Unit 2b1 Health IT Workforce Curriculum.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
基智科技 結構化佈線系統測試 基智科技 銅線部分 基智科技 Test Standard Requirements.
Sep-03 ©Cisco SystemsCCNA Semester 1 Version 3 Comp11 Mod4 – St. Lawrence College – Cornwall Campus – Clark slide 1.
CABLING SYSTEM ADMINISTRATION. Administration Concept.
CCNA 1 v3.0 Module 4 Cable Testing. Objectives Waves.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
Signamax™ Cabling System Review Revision E. INTRODUCTION.
COPPER AND FIBER REVIEW
BACKBONE SUBSYSTEM. CABLING SYSTEM Backbone Subsystem The Backbone cabling subsystem is based on cabling segments, which link such connection centers.
Cisco Semester 1 Chapter 4 Slides Cable Testing
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
CABLING SYSTEM WARRANTY REGISTRATION. PURPOSE OF CABLING REGISTRATION.
TOPIC 1.2 INTRODUCTION TO NETWORKING. OBJECTIVES By the end of the topic, students should be able to: a) List the elements of data communication systems.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
By: Thomas Olivotti.  PSNEXT stands for Power Sum Near End Crosstalk and is calculated by transmitting a signal down each wire pair in turn and summing.
Developing Cabling Module Situation at August 2006 Vello Vanem.
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
Pertemuan 10 Signal & Noise
Module 4 Cable Testing.
Ch 7 Fiber Optics Technician’s Manual, 3rd. Ed Jim Hayes
Wired and Wireless Troubleshooting
CCNA 1 v3.1 Module 4 Cable Testing
CCNA 1 v3.1 Module 4 Cable Testing
Presentation transcript:

CABLING SYSTEM CERTIFICATION TESTING

TWISTED-PAIR CABLING TESTING

Test Configurations Certification testing may be performed for either of two or both models of the cabling system: –Channel –Permanent Link

Channel Model The Channel test configuration should be used to verify the overall Channel performance Channel starts here ABCDE FIELD TESTER TRWA TOCPHC Channel starts here

Channel Model  1 Any Channel models of the twisted-pair Horizontal and Backbone subsystems with the cable overall length of under 100 m, including connecting hardware and equipment cords, shall pass 100% certification testing The Channel certification testing of the twisted-pair Signamax Cabling System may apply the testing settings of the field testers for the compliance of the cabling system Channel transmission performance parameters with the requirements of various standards (ISO, TIA, CENELEC, AS/NZ and any others available in the field tester software)

Permanent Link Model The Permanent Link test configuration should be used to verify the efficiency of permanently installed cabling Link starts here ABCD FIELD TESTER TRWA TOCPHC Link starts here

Permanent Link Model  3 Any Permanent Link models of the twisted-pair Horizontal and Backbone subsystems with the cable length of less than 90 m (295 ft) shall pass 100% certification testing The Permanent Link certification testing of the twisted- pair Signamax Cabling System may apply the testing settings of the field testers for the compliance of the cabling system Channel transmission performance parameters with the requirements of various standards (ISO, TIA, CENELEC, AS/NZ and any others available in the field tester software)

TEST PARAMETERS

Test Parameters  5 On testing of the category 5e, 6, and 6A Channels and Permanent Links of the twisted-pair cabling system the following parameters shall be tested: Wire map and screen continuity Return loss (RL) Insertion loss (IL) Propagation delay (PD) Propagation delay skew (PDS) Pair-to-pair near-end crosstalk loss (NEXT) Power-sum near-end crosstalk loss (PSNEXT) Pair-to-pair attenuation-to-crosstalk ratio, far end (ACRF) Power-sum attenuation-to-crosstalk ratio, far end (PSACRF)

Test Parameters  1 On testing of the category 6A Channels and Permanent Links of the twisted-pair cabling system the following parameters are recommended to be tested, but not required for the Signamax Cabling System warranty provision: Power-sum alien near-end crosstalk (PSANEXT) loss Average power-sum alien near-end crosstalk (PSANEXT) loss Power-sum attenuation-to-alien crosstalk ratio, far-end (PSAACRF) Average power-sum attenuation-to-alien crosstalk ratio, far-end (PSAACRF)

TEST RESULTS

PASS/FAIL Criteria A Pass or Fail result for each parameter shall be determined by the permissible parameter limits The parameter test result shall be marked with an asterisk (*) when it is closer to the test limit than the measurement accuracy published by the field tester manufacturer for the Permanent Link and Channel

PASS/FAIL Criteria 1 – Parameter allowable limit 2 – Measurement accuracy upper limit 3 – Measured parameter value 4 – Measurement accuracy lower limit

PASS/FAIL Criteria  6 The test results marked PASS obtained as a result of testing of all the parameters determined in  5 shall be registered and submitted for the warranty provision. The test results marked PASS*, FAIL* and FAIL shall not be registered and submitted for the warranty provision

Test Results Saving  7 Any positive test results shall be recorded in an electronic format with software supplied by the field tester manufacturer. The test results supplied in the format not supported by the field tester software shall not be accepted for registration

FIELD TESTERS

Qualified Field Testers  8 Warranty certification testing of transmission performance of the Signamax Cabling Systems shall be performed by one or several of the following field testers : –Agilent Technologies:WireScope 350, WireScope Pro, FrameScope 350 –Fluke Networks:OMNIScanner, OMNIScanner2, DSP-4000, DSP-4100, DSP-4300, DTX-1800, DTX-1200, DTX-LT –IDEAL Industries:LT 8100A, LT 8155T, LT 8600T, LANTEK 6, LANTEK 7, LANTEK 7G, LanTEK II-350, LanTEK II-500, LanTEK II-1000 –JDSU:Certifier40G –Megger:SCT1500, SCT2000 –Psiber Data:WireXpert

Software  9 Qualified field tester used for the Signamax Cabling System testing shall operate with the latest software version as of the date of such testing. Test results obtained with outdated software version are invalid and shall not be accepted for the system warranty registration.

OPTICAL FIBER CABLING TESTING

TEST CONFIGURATIONS

Optical Fiber Link An optical fiber link segment is the passive cabling, to include cable, connectors, and splices (if present), between two optical fiber connecting hardware termination points TEST JUMPER 1 OPTICAL FIBER LINK UNDER TESTTEST JUMPER 2 CROSS-CONNECT OR OUTLET LIGHT SOURCEPOWER METER 850 nm1300 nm ONOF dBm 850 nm 1300 nm  ONOF CROSS-CONNECT

TEST PARAMETERS

Test Parameters Testing of the optical fiber components and systems includes measurements of several major characteristics For the certification testing of the majority of the optical fiber cabling systems, installed in the buildings and campus environments, it is usually sufficient to get the data on insertion loss and, optionally, return loss and optical length Bandwidth (multimode) and dispersion (singlemode) are important performance parameters, however as they cannot be adversely affected by installation practices, they should be tested by the fiber manufacturer and do not require any field testing

Insertion Loss  15 Any optical fiber Links of the Horizontal and Backbone cabling subsystems shall be tested for insertion loss Insertion loss test shall be carried out by the one reference jumper method

FIELD TESTERS

Qualified Field Testers  20 Warranty certification insertion loss testing of the Signamax Optical Fiber Cabling System shall be performed with: –Power meter and light source or –Test equipment listed in  6, including the optical fiber detectors within their sets, facilitating insertion loss tests Characteristics of the test equipment shall comply with the specifications given in sections “ Power meters” and “ Light sources” of the Signamax Cabling System Manual