DQM for the RPC subdetector M. Maggi and P. Paolucci.

Slides:



Advertisements
Similar presentations
Giuseppe Roselli (CMS-RPC) Università degli Studi di Bari – INFN RPC Efficiency with Track Reconstruction Giuseppe Roselli.
Advertisements

RPC Trigger Software ESR, July Tasks subsystem DCS subsystem Run Control online monitoring of the subsystem provide tools needed to perform on-
CSC DQA and Commissioning Summary  We are responsible for the online and offline DQA for the CSC system, a US ATLAS responsibility  We are ready for.
US LPC Muon Group CMSSW code development efforts N. Terentiev Carnegie Mellon University CMS EMU Meeting, Florida Institute of Technology February 17-18,
Data Quality Monitoring for CMS RPC A. Cimmino, D. Lomidze P. Noli, M. Maggi, P. Paolucci.
2011 HV scan SF6 flow-meter accident 2011 Results comparison RPC HV efficiency scan Pigi Paolucci on behalf of RPC collaboration.
MuonDPG/RPC M. Maggi INFN Bari. DQM tool for the DCS data Control Analysis Tool (CAT) by Cimmino, Lomidze, Paolucci, Polese To 1.Make custom DCS data.
A. Cimmino - P. Paolucci - G. Polese / DCS meeting DQM tool for the DCS data What the RPC community needs: 1.Make online/offline DCS data.
Event display monitoring Giuseppe Zito : Infn Bari Italy Beliy Nikita : University of Mons-Hainaut Belgium.
Data Quality Monitoring of the CMS Tracker
L3 Filtering: status and plans D  Computing Review Meeting: 9 th May 2002 Terry Wyatt, on behalf of the L3 Algorithms group. For more details of current.
Central DQM Shift Tutorial Online/Offline. Overview of the CMS DAQ and useful terminology 2 Detector signals are collected through individual data acquisition.
Central DQM Shift Tutorial Online/Offline. Overview of the CMS DAQ and useful terminology 2 Detector signals are collected through individual data acquisition.
RPC Readiness for Data-taking RPC Collaboration 1.
Offline Tracker DQM Shift Tutorial. 29/19/20152 Tracker Shifts Overview Online Shifts at P5 (3/day for 24 hours coverage) – One Pixel shifter and one.
Test Of Distributed Data Quality Monitoring Of CMS Tracker Dataset H->ZZ->2e2mu with PileUp - 10,000 events ( ~ 50,000 hits for events) The monitoring.
JCOP Workshop September 8th 1999 H.J.Burckhart 1 ATLAS DCS Organization of Detector and Controls Architecture Connection to DAQ Front-end System Practical.
Web Based Monitoring DT online shifter tutorial Jesús Puerta-Pelayo CIEMAT Muon_Barrel_Workshop_07/July/10.
DQM Architecture From Online Perspective EvF wkg 11/10/2006 E. Meschi – CERN PH/CMD.
RPC PAC Trigger system installation and commissioning How we make it working… On-line software Resistive Plate Chambers Link Boxes Optical Links Synchronization.
XXVI Workshop on Recent Developments in High Energy Physics and Cosmology Theodoros Argyropoulos NTUA DCS group Ancient Olympia 2008 ATLAS Cathode Strip.
Level 3 Muon Software Paul Balm Muon Vertical Review May 22, 2000.
CMS Databases P. Paolucci. CMS DB structure HLT-CMSSW applicationReconstruction-CMSSW application FronTIER read/write objects.
ATLAS Liquid Argon Calorimeter Monitoring & Data Quality Jessica Levêque Centre de Physique des Particules de Marseille ATLAS Liquid Argon Calorimeter.
Gnam Monitoring Overview M. Della Pietra, D. della Volpe (Napoli), A. Di Girolamo (Roma1), R. Ferrari, G. Gaudio, W. Vandelli (Pavia) D. Salvatore, P.
Tracker data quality monitoring based on event display M.S. Mennea – G. Zito University & INFN Bari - Italy.
Detector Diagnostics Calibration Analysis Ped/LED/Laser RadDam Analysis Detector Optimization Lumi Detector Performance Monitoring DQM On/Offline Prompt.
A.Golunov, “Remote operational center for CMS in JINR ”, XXIII International Symposium on Nuclear Electronics and Computing, BULGARIA, VARNA, September,
RPC DQA but also Monitoring for the DCS group: status and prospective for Marcello Bindi RPC L1MU Barrel DQM - 08/05/2013.
Barrel RPC Chamber consists of 2 double-gaps, each equipped with a common plane of 96 strips read-out by 6 front-end boards. The two double- gaps have.
Giovanni Polese1 RPC Detector Control System for MTCC Pierluigi Paolucci, Anna Cimmino I.N.F.N. of Naples Giovanni Polese Lappeenranta University.
Clara Gaspar, March 2005 LHCb Online & the Conditions DB.
CMS pixel data quality monitoring Petra Merkel, Purdue University For the CMS Pixel DQM Group Vertex 2008, Sweden.
Introduction CMS database workshop 23 rd to 25 th of February 2004 Frank Glege.
1 Status and Outlook of the RPC Commissioning Marcello Maggi/INFN-Bari.
Overview of DAQ at CERN experiments E.Radicioni, INFN MICE Daq and Controls Workshop.
4 th Workshop on ALICE Installation and Commissioning January 16 th & 17 th, CERN Muon Tracking (MUON_TRK, MCH, MTRK) Conclusion of the first ALICE COSMIC.
ALICE Pixel Operational Experience R. Santoro On behalf of the ITS collaboration in the ALICE experiment at LHC.
RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo.
2009 RPC CAF experience We did a very good exercise at the end of 2009 – 2 shifters + 1 shift leader + Experts: Costantini/Ocampo/Carillo/Cimmino/Lomidze/Tupputi/Trentadue.
Data Quality Monitoring for the CMS Resistive Plate Chamber Detector Anna Cimmino etc etc etc Università degli Studi di Napoli “ Federico II ” & INFN of.
Online (GNAM) and offline (Express Stream and Tier0) monitoring produced results during cosmic/collision runs (Oct-Dec 2009) Shifter and expert level monitoring.
Michele de Gruttola 2008 Report: Online to Offline tool for non event data data transferring using database.
MoA and M & O-B Pigi Paolucci. Introduction The RPC endcap and barrel project were merged in an unique project in the 2009 and so we don’t have a long.
1 Checks on SDD Data Piergiorgio Cerello, Francesco Prino, Melinda Siciliano.
Pixel DQM Status R.Casagrande, P.Merkel, J.Zablocki (Purdue University) D.Duggan, D.Hidas, K.Rose (Rutgers University) L.Wehrli (ETH Zuerich) A.York (University.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
Software for the CMS Cosmic Challenge Giacomo BRUNO UCL, Louvain-la-Neuve, Belgium On behalf of the CMS Collaboration CHEP06, Mumbay, India February 16,
Notes in preparation by the Torino group Sara BolognesiDT Cosmic Meeting 01/11/2007  MTCC note:  calibration section  DQM section  Internal note about.
DQM for the RPC subdetector M. Maggi and P. Paolucci.
The DCS Databases Peter Chochula. 31/05/2005Peter Chochula 2 Outline PVSS basics (boring topic but useful if one wants to understand the DCS data flow)
Online Consumers produce histograms (from a limited sample of events) which provide information about the status of the different sub-detectors. The DQM.
Валидация TRT DCS CONDITIONS SERVICE Евгений Солдатов, НИЯУ МИФИ “Physics&Computing in ATLAS” – 22/09/2010.
Commissioning and run coordination CMS week Commissioning plenary 28-February 2007 DQM and monitoring workshop MandateGoals.
ID Week 13 th of October 2014 Per Johansson Sheffield University.
ATLAS The ConditionDB is accessed by the offline reconstruction framework (ATHENA). COOLCOnditions Objects for LHC The interface is provided by COOL (COnditions.
QC-specific database(s) vs aggregated data database(s) Outline
P. Paolucci G. Pugliese M.Tytgat
RPC Data Certification
Offline shifter training tutorial
Muon DPG 2012 Camilo Carrillo (INFN Napoli) Tim Cox (UC Davis)
Data Quality Monitoring of the CMS Silicon Strip Tracker Detector
Status of RPC software in CMSSW
23 Barrel chambers and 12 Endcap chambers
CMS Pixel Data Quality Monitoring
Status of RPC DQM for Global DAQ in CMSSW
DQM for the RPC subdetector
CMS Pixel Data Quality Monitoring
Pierluigi Paolucci & Giovanni Polese
23 Barrel chambers and 12 Endcap chambers
Presentation transcript:

DQM for the RPC subdetector M. Maggi and P. Paolucci

DQM workshop - 28 feb 07 2 M. Maggi and P. Paolucci Outlook RPC DQM requirements event Data DQM – what we have done and learned during the MTCC we need more “sophisticated” DQM tools to access online database (non event data) guidelines and open issues DQM group composition conclusions

DQM workshop - 28 feb 07 3 M. Maggi and P. Paolucci RPC DQM requirements I DQM has to monitor the RPC detector/trigger behavior and measure and summarize their performances: Online monitoring in FF: pre-scaled subset of LV1 muon events (rate ?) delay is 0 ? CMS CPUs (how many ?) Online monitoring in event consumer: pre-scaled subset of LV1 muon events (rate ?) Full use of DCS and XDAQ data via DB RPC CPUs (to design) delay ? seconds ?

DQM workshop - 28 feb 07 4 M. Maggi and P. Paolucci RPC DQM requirements II Quasi-online: LV1 muon events DCS and XDAQ access via Condition DB RPC CPUs delay of minutes ? Offline monitoring: for RPC experts to have a full analysis Using full events and reconstruction tools using DBs CMS CPus delay ? hours ?

DQM workshop - 28 feb 07 5 M. Maggi and P. Paolucci Event Data monitoring STATUS I DQM-analysis packages developed for RPC in CMSSW and test during the MTCC: EventFilter/RPCRawToDigi (Segoni - Maggi): It drives the raw data unpacking and produces the RPCDigi collection committed to the event. DQM/RPCMonitorModule (Segoni – Maggi): it carries out data integrity check and basic detector functioning tasks POOL Source Raw Data Digi Unpacker DAQ Clusters/RecHits Local Muon Reconstruction RPCMonitorDigi RPCMonitorModule Event

DQM workshop - 28 feb 07 6 M. Maggi and P. Paolucci Event Data monitoring STATUS II DQM/RPCMonitorDigi: Uses the digi produced by the unpacker (i.e. for each h-partition the collection strip with signal and the BX ) to perform chamber performance checks: BXN # of digi Occupancy Cluster multiplicity Cluster size Sync: Specific trigger studies Chamber efficiency is produced by extrapolating DT segments to the RPC mounted on the same DT chamber and looking for matching hits

DQM workshop - 28 feb 07 7 M. Maggi and P. Paolucci Guidelines answers YES, we need history/trendig plots (efficiency, occupancy, cluster size…) YES, we need correlation trends YES, we need tools to extract complex info from condition DB and repository YES, we are using IGUANA to present DQM results MORE, we have to work on how make histo/result persistent MORE, we developed a first prototype of a synoptic view YES, we have a clear hierarchical view of the plots NO, automatic analysis procedures, for the moment YES, we can converge on a run quality flags but we have to work on

DQM workshop - 28 feb 07 8 M. Maggi and P. Paolucci RPC synoptic view We are working on to have a full synoptic view of our system with interactive features, alarm, warning and error

DQM workshop - 28 feb 07 9 M. Maggi and P. Paolucci Do we need.. More.. Tools ? YES For RPC it is CRUCIAL to correlate event data DQM info with PVSS and XDAQ non event data: Chamber efficiency.vs. Noise (XDAQ) Chamber efficiency.vs. Current (PVSS) Noise (XDAQ).vs. Temperature (PVSS) Cluster size.vs Temperature (PVSS) ………………………………………….. To let understand the behavior of the RPC system we need: few summary plots for the DQM shifter (online) more plots for RPC shifter (quasi-online) a complete way to analyze data for the RPC expert (offline)

DQM workshop - 28 feb M. Maggi and P. Paolucci Do we need.. More.. Tools ? YES For MTCC data we developed the following tool CAT For data tacking we want to integrate it in the DQM but we need to take some decisions: 1.How access online at the Condition DB: direct access to the DB or to a replication of the DB ?? 2.Which and how many plots we want to store permanently ?? 3.Do we need reference plots also for correlated data ?? 4.Can we show/store in the DQM full DCS and XDAQ histograms/results too ?? Analysis tools Online DBRoot files DB query histograms DB replication

DQM workshop - 28 feb M. Maggi and P. Paolucci Histos produced during the MTCC using CAT RMS distribution of the 23 chambers for a 4 days period with magnet ON and stable conditions Having 480 chambers only in the barrel it was very useful to have summary plot from DCS (retrieving data from cond. db). We need to think about more summary plots from DQM–DCS–XDAQ RMS = 0.5  A Chamber to check using more info from DCS-DQM-XDAQ for RPC expert

DQM workshop - 28 feb M. Maggi and P. Paolucci A way to use DB HLT-CMSSW applicationReconstruction-CMSSW application read/write objects read/write Transformation (O2O) DCS/DQM Application DQM/Offline Application

DQM workshop - 28 feb M. Maggi and P. Paolucci The open issues … for us How many CPUs on Filter Farm will be used for DQM (0-10% of HTL) ? Which muon trigger downscale we can effort ? Can we have a muon rate of KHz in the Filter Farm ? What can we run on the Storage Manager ? Which latency we can effort for non-event data (Online DB duplication in IT) ? Do we need dedicated RPC CPUs and disks to run the quasi-online DQM ? How have an unique graphical interface for DCS- DQM-XDAQ to help people in shift ? Questions will be already answered here

DQM workshop - 28 feb M. Maggi and P. Paolucci RPC DQM group composition The group works in the DPG under the supervision of M. Maggi and myself and in contact with Muon DPG people. detector DQM: Bari –4 people  sharing with Offline/DQM Napoli –5 people  sharing with DCS Pavia –2 people  sharing with Reco & Ev Displ. trigger DQM: Warsaw group  sharing with trigger activities We need people from the endcap groups

DQM workshop - 28 feb M. Maggi and P. Paolucci Conclusions The RPC-specific components of the DQM structure in CMSSW are well under development and tested on MTCC data with proper Global DAQ format. The development now must focus now on: Interface DQM with the Condition DB Production of historical plots, with interface to off-line DB Select a few number of “smart” summary histo/plot/tables Use also higher level objects (muon tracks, reco tools….) We are developing: detector visualization and web interface, quality test producing warning, error and alarm and tree-like structure for histo, plot….