J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 1 Exercising emittance measurements in the ATF EXT line Upgrade.

Slides:



Advertisements
Similar presentations
Emittance Reconstruction from measured Beam Sizes A.Faus-Golfe and Jesus Navarro Faus IFIC Valencia.
Advertisements

Sha Bai, Philip Bambade, Glen White FJPPL – FKPPL ATF2 workshop LAL, 11~13 February, 2013 Orthogonality of beam waist corrections in the presence of IPBSM.
SESAME – TAC 2012: M. Attal Maher Attal SESAME Booster Characterization.
Coupling Correction in ATF2 EXT 7 th ATF2 Project Meeting, december 2008 C.Rimbault, LAL Orsay.
Emittance Measurement Simulations in the ATF Extraction Line Anthony Scarfe The Cockcroft Institute.
ATF2 FB/FF layout Javier Resta Lopez (JAI, Oxford University) for the FONT project group FONT meeting January 11, 2007.
Optics for Skew Correction and Emittance Measurement Leo Jenner This talk is going to look familiar if you were at the recent LC-ABD meeting in Manchester…
Mark Rayner, Analysis workshop 4 September ‘08: Use of TOFs for Beam measurement & RF phasing, slide 1 Use of TOFs for Beam measurement & RF phasing Analysis.
July 22, 2005Modeling1 Modeling CESR-c D. Rubin. July 22, 2005Modeling2 Simulation Comparison of simulation results with measurements Simulated Dependence.
Lattice calculations: Lattices Tune Calculations Dispersion Momentum Compaction Chromaticity Sextupoles Rende Steerenberg (BE/OP) 17 January 2012 Rende.
Simulation of IP beam size with orbit jitter + wakefield in EXT-FF ATF2 Project Meeting K.Kubo.
Analysis of ATF EXT/FF Orbit Jitter and extrapolation to IP (Data of ) ATF2 Project Meeting K. Kubo.
Status of very high priority beam tuning software Special ATF2 project meeting, Korea, 1 st October 2008 Cécile Rimbault, on behalf of High Priority task.
1 Proposal for a Multi-Optical Transition Radiation System in ATF2 A. Faus-Golfe, D. McCormick IFIC – SLAC 11 June th TB/SGC Meeting.
ATF2 Javier Resta Lopez (JAI, Oxford University) for the FONT project group 5th ATF2 project meeting, KEK December 19-21, 2007.
Kicker Optics – or – Selected ATF-II EXT Line Performance Issues ATF-II Technical Review, April M. Woodley1/40.
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, N.Kazarinov.
ATF2 optics … 1 3 rd Mini-Workshop on Nano Project at ATF ATF2 optics, tuning method and tolerances of initial alignment, magnets, power supplies etc.
ATF2 Tuning Updates Glen White, SLAC Sept
Matching recipe and tracking for the final focus T. Asaka †, J. Resta López ‡ and F. Zimmermann † CERN, Geneve / SPring-8, Japan ‡ CERN, Geneve / University.
Fifth ATF2 Project Meeting, dec. 2007, KEK, Japan Emittance measurements with multiple wire-scanners and quadrupole scans in ATF EXT C. Rimbault,
Studies on Lattice Calibration With Frequency Analysis of Betatron Motion R. Bartolini DIAMOND Light Source Ltd FMA workshop, Orsay, LURE, 1 st and 2 nd.
ATF1/2 laser-wires Stewart T. Boogert on behalf of UK Extraction line laserwire collaboration A. Aryshev, G. Blair, S. Boogert, A. Bosco, L. Corner, L.
Summary of Commissioning and Tuning session Philip Bambade LAL-Orsay 5 th ATF2 project meeting KEK, 21 December 2007.
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, A.Drozhdin, N.Kazarinov.
EMMA Horizontal and Vertical Corrector Study David Kelliher ASTEC/CCLRC/RAL 14th April, 2007.
Mark Woodley, SLACATF2 Project March 20-21, Summary of Tuning, Corrections, and Commissioning.
Intermediate  configurations at the IP for commissioning and optimization Sha BAI IHEP/LAL Philip BAMBADE LAL.
Mark Rayner 14/8/08Analysis Meeting: Emittance measurement using the TOFs 1 Emittance measurement using the TOFs The question: can we use position measurements.
ATF2 Commissioning Toshiyuki Okugi 2008 / 7 /9 ATF2 beam commissioning meeting, KEK.
Alexander Molodozhentsev KEK for MR-commissioning group September 20, 2005 for RCS-MR commissioning group September 27, 2005 Sextupole effect for MR -
Low emittance tuning in ATF Damping Ring - Experience and plan Sendai GDE Meeting Kiyoshi Kubo.
Vertical Emittance Tuning at the Australian Synchrotron Light Source Rohan Dowd Presented by Eugene Tan.
Frequency Map Analysis Workshop 4/2/2004 Peter Kuske Refinements of the non-linear lattice model for the BESSY storage ring P. Kuske Linear Lattice My.
Analysis of Multipole and Position Tolerances for the ATF2 Final Focus Line James Jones ASTeC, Daresbury Laboratory.
Study of alternative ILC final focus optical configurations Dou Wang (IHEP), Yiwei Wang (IHEP), Philip Bambade (LAL), Jie Gao (IHEP) International Workshop.
First analysis results of EXT MW0-4 X,Y,- 10,-10 wire-size measurements to reconstruct the 4D betatron phase-space.
Design options for emittance measurement systems for the CLIC RTML R Apsimon.
Location of the LW detector- Simulation of the LW signals Lawrence Deacon RHUL ATF2 meeting August 23 rd 2006 KEK.
Upcoming Shift Work at ATF (November 26 – December 21, 2007) and Remote Participation from SLAC ATF training shifts proposal Rob Appleby (contact person,
Emittance Tuning Simulations in the ILC Damping Rings James Jones ASTeC, Daresbury Laboratory.
Emittance measurements with multiple wire-scanners and quadrupole scans in ATF EXT C. Rimbault, Brossard, P. Bambade (LAL) Main goal : - Try to improve.
Summary of Tuning, Corrections, and Commissioning ( Short summary of ATF2 meeting at SLAC in March 2007 ) and Hardware Issues for beam Tuning Toshiyuki.
ATF2 Software Review LAL June 2008 Philip Bambade & Glen White ATF2 weekly meeting June
ERHIC Orbit Correction Studies (Minor Update) Using Oct’14 lattice and dispersion diagnostic January 5, 2015Stephen Brooks, eRHIC FFAG meeting1.
Simulation of the α, dispersion, coupling and β multiknobs in large β optics Sha Bai, Philip Bambade, Benoit Bolzon, Javier Resta Lopez
Tools in CTF3 Simona Bettoni for the CTF3 operation team.
Status of EXT coupling measurement analysis 9 th ATF2 project meeting C.Rimbault (LAL) S. Kuroda, T. Tauchi, N. Terunuma (KEK), G. White, M. Woodley (SLAC)
1 RTML Emittance Measurement Station Yuri Kubyshin (1), Robert Apsimon (2), Hector García (1,2) (1) Technical University of Catalonia (UPC) (2) CERN CLIC.
11/18/2004 FNAL Advanced Optics Measurements at Tevatron Vadim Sajaev ANL V. Lebedev, V. Nagaslaev, A. Valishev FNAL.
Status and plan of Beta-matching in Extraction line Kiyoshi Kubo.
Wakefield effect in ATF2 Kiyoshi Kubo
2nd ATF2 Project Meeting (May 30, 2006)M. Woodley [SLAC]1 ATF2 Layout/Optics (v3.3) nBPM (SLAC) nBPM (KEK) FONT Compton / laserwire ODR Existing ATF Extraction.
Numerical Simulations for IOTA Dmitry Shatilov BINP & FNAL IOTA Meeting, FNAL, 23 February 2012.
4 th ATF2 Project Meeting, 31 May 2007 A. Seryi 1 Summary of SLAC simulation study of emittance growth in the ATF extraction line SLAC team: J. Amann,
Review of Alignment Tolerances for LCLS-II SC Linac Arun Saini, N. Solyak Fermilab 27 th April 2016, LCLS-II Accelerator Physics Meeting.
Simulation for Lower emittance in ATF Damping Ring Kiyoshi Kubo Similar talk in DR WS in Frascati, May 2007 Most simulations were done several.
RF-kick in the CLIC accelerating structures
Measurements and analysis of beam parameters at post-IP wire-scanner
Orbit Response Matrix Analysis
Estimating the effects from non-linearities in the ATF extraction line
Tolerances & Tuning of the ATF2 Final Focus Line
ILC Z-pole Calibration Runs Main Linac performance
Beam Optics Set-Up at SLAC End Station A
3rd ATF2 Project Meeting, December 18-20, 2006
6.1 Introduction to Chi-Square Space
Emittance Diagnostics
ATF2 Layout/Optics (v3.6) Existing ATF Extraction Line
DTL M. Comunian M. Eshraqi.
Yuri Nosochkov Yunhai Cai, Fanglei Lin, Vasiliy Morozov
Presentation transcript:

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 1 Exercising emittance measurements in the ATF EXT line Upgrade of Annecy meeting slides …. J. Brossard / C. Rimbault / P. Bambade (LAL)

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 2 ATF EXT line description & wire scanner position 5 positions for wire scanners Diagnostic section (  x =  y =  ) Each position is equipped with 3 wire scanners oriented at 0, 90 and 10° for y,x and 10° beam-size measurement. Wire thickness = 10  m & 50  m 90° 10° 0° Diagnostic section (  x =  y =  )

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 3 Evolution of Horizontal & Vertical sqrt(beta) and phase functions along EXT line for nominal and modified EXT line. QM7

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 4 Horizontal & Vertical beam size at wire-scanner positions for nominal and modified EXT mad deck.  x =sqrt(  x  x )  y =sqrt(  y  y )  x = m  x=   x(s)  y = m  y=   y(s) Wire thickness = 50  m Wire thickness = 10  m

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 5 Exercice : Run MAD with QM7 = Nominal value & QM7 = QM7-20% Remark : Only the K1 value is modified What about the dipole kick induce by the x-offset position in the quad ? At each wire scanner the beam matrix is computed (output from MAD). A relative gaussian error on  11  33  13 is added (for 1000 succesives « measurements »): At present time, we assume that :  13 =  10° Where  varie from 0 to 30 Assuming no x-y coupling for nominal case ( =0)

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 6 The Least Means Square Method (LMS) is used to find « the LMS solution ». The « 2D-emittance » reconstruction method is base on 3 different over-estiminated linear systems : Example for  x measurement Measurement of  x at the 5 wire scanners (obtained with MAD deck where QM7=QM7-20%) R ij Linear transport coefficent (using QM7 nominal value) Beam matrix element at the reference input point A.  10° measurements to defined  4  5  7 and  8  y measurements to defined  6  9 and  10 Then the 2D projected emittance  x and  y are computed using :

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 7 2D projected emittances

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 8 4D intrinsinc emittances If is diagonalisable then Then the 2D projected emittance  x and  y are computed using :

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 9 Rejection level : 4D intrinsinc emittances BUT …. Preliminary results…. Some mathematical point in MATLAB need to be understand.

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 10 2D projected emittances

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 11 END Next step : Modified the  10° measurement simulation using a tracking particles.

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 12 4d-beam matrix at point A : 4d-beam matrix at point B : Where is the 4D-linear optic matrix from point A to point B. 4d - reconstruction method based on 5 wire scanner measurements

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 13 4d - reconstruction method based on 5 wire scanner measurements If the 4d-linear transport matrix from point A to B is uncoupled Then =(x-beam B) 2 =(y-beam B) 2 -> For « n » points (B,C,…Z), where the x beam size is measure, we have : If we know how to solve this linear system then, we can compute the horizontal emittance : Similar analysis can be performed to estimate :  4, to  10 … and   y can be estimated.

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 14 4d - reconstruction method based on 5 wire scanner measurements If n<3 No solution. If n==3 and M x -1 exist then the solution is known and unique. If n>3 the sytem is « overestimated » and the Least Mean Square (LMS) method can be used to find the « LMS » solution. (in ATF n==5) First question : How sensitive to wire scanner errors this method is ? Second question : What happen if the QM6 quadrupole strength is reduce by 20% ?

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 15 Assumption : the relative error level on « measurements » at position MW0X, MW1X, MW2X, MW3X and MW4X is identical, and tested for values ranging between 0 and 30% The minimum relative error level for y-beam size measurement is at least equal to 13% (D/4~1.25 microns) Where « r » comes from a gaussian distribution having zero mean and X/100 rms First question : How sensitive to wire scanner errors this method is ?

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 16 First question : How sensitive to wire scanner errors this method is ? For each error level, 1000 « measure » have been tested. The plot shows the mean and +/- 1 rms mean value rms value The maximum relative errors (define by the rms value) on  11,  12,  22,  33,  34 and  44 values are approximatively between -30% and +30%

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 17 A part of the 1000 tested « measurements » lead to a unphysical results. In the current analysis, this rejection level is always lower than 4%. First question : How sensitive to wire scanner errors this method is ? Impact on horizontal and vertical emittance reconstruction …  This method leads to underestimate vertical and horizontal emittance. The underestimation of horizontal emittance is higher than the vertical one.

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 18 Second question : What happen if the QM6 quadrupole strength is reduce by 20% ? QM6 is the first bending magnet (with quadrupole part) after the kicker. The quad. strength of this element might have been over-estimated…(TBC) The maximum error level on  11,  12,  22 and  44 is similar to the previous analysis (i.e : +/- 30%) The maximum error level on  33 and  34 reach +100 or +200% !!!

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 19 Second question : What happen if the QM6 quadrupole strength is reduce by 20% ? In presence of WS error, the - horizontal emittance is sligthly underestimated - vertical emittance is greatly over-estimated. Impact on horizontal and vertical emittance reconstruction … The rejection part increase… to reach 40% for error measurement of 30 % Absolute values (m.rad) Absolute values (m.rad) relative values (%) + 30%

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 20 Preliminary Quadrupole Strengh Variation method - 1 MW2X MW3X    (mm 2 )   x = mm.mrad   x = mm.mrad 5 positions for wire scanners QD6X

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 21 Preliminary Quadrupole Strengh Variation method positions for wire scanners QD6X MW2X MW3X   y = e-05 mm.mrad   y = e-05 mm.mrad    (mm 2 )

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 22 Conclusions and perspectives Conclusions and persepctives - For the nominal ATF-EXT line, the LMS* method based on the 5 existing wire scanners induced an underestimation of the vertical and horizontal emittance (function of WS error level). - If the QM6 quadrupole strength is underestimated (by 20%) then the LMS method based on the 5 existing wire scanner induced a « small » horizontal emittance reduction and a « large » vertical emittance estimation (function of WS error level). For QM7 quadrupole strength underestimation an symetric (x-y) effect is observed (see extra slide). - Compare the error sensitivity of the LMS reconstruction method with a « quadrupole strength variation » method. Questions - What are the real « quadrupole strength » of QM6 and QM7 (seen by the extracted bunch) ? - Is it possible to determine WS positions leading to less error sensitive reconstruction method ? - What is the sensitivity of « quadrupole strength variation » method ? (which quad ? which WS ?, new quad position ?, new WS position ? ….). - Is it possible to realize more than 3 measurement per WS to reduce the error level ? - others ideas ? … * LMS : Least Mean Square

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 23 References Many thanks to Mark Woodley for the input MAD file (see : References : ATF Internal reports : ATF-99-01, ATF-00-06, ATF-99-17, ATF-99-08, ATF-00-01…

J. Brossard, C. Rimbault a P. Bambade LAL / / 8-9 nov LAL 24 Extra-slide QM6 quadrupole strength is reduce by 20%  QM7 quadrupole strength is reduce by 20%  (see M. Alabau Pons & al. Talk) + 10% + 30% Absolute values (m.rad) Absolute values (m.rad) Relative values (%)