Lecture 4a Gas Chromatography.

Slides:



Advertisements
Similar presentations
Gas Chromatography.
Advertisements

Gas Chromatography Introduction 1.) Gas Chromatography
Gas Chromatography 427 PHC.
Lecture 8b Gas Chromatography.
Gas Chromatography.
Gas Chromatography & Gas-Liquid Chromatography
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
Lab Methods Day June 25, 2014 Gas Chromatography
Analysis of Residues. Laboratory Analysis of Debris and Other Samples 1. Preparation of Liquid Samples: Liquid samples are simply drawn into a special.
1 Gas Chromatography Lecture a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection.
Chromatography CHEMISTRY Chromatography Chromatography is a technique for separating species based on physical or chemical properties. Usually.
In carbon-13 NMR, what do the number of peaks represent?
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental.
Gas Liquid Chromatography
Gas Chromatography. Gas Chromatography Basics Gas Liquid Chromatography (GLC) Gas Solid Chromatography (GSC) Mobile phase does not interact with analyte.
Chapter 22 GC & LC Gas Chromatography -1 1.Schematic diagram.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Chromatography Year 12.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
By, Blessy Babu. What is Gas Chromatography?  Gas spectroscopy is a technique used to separate volatile components in a mixture.  It is particularly.
Chemical Ideas 7.6 Chromatography. The general principle. Use – to separate and identify components of mixtures. Several different types - paper, thin.
Chapter 27 Gas Chromatography 1. Principles
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Magnet Analytical Chemistry Unit 4
In gas-liquid chromatography (g.l.c.) a long tube contains the chromatography material. The tube is usually coiled so that it takes up less space.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
Gas Chromatography A separation science.... What is Chromatography? The separation of a mixture of two or more compounds or ions by distribution between.
Separation Science Differences in IMFs can be used to separate chemical substances for further analysis. Differences in IMFs can be used to separate chemical.
PLOT Columns P orous L ayer O pen T ubular Porous layer open tubular (PLOT) columns are defined as capillary columns where the inner surface is coated.
animation.php.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
INTRODUCTION TO CHROMATOGRAPY
GAS CHROMATOGRAPHY (GC). GAS CHROMATOGRAPHY Sample is injected (using a syringe) into the injection port. Sample vaporizes and is forced into the column.
Gas Chromatography Experiment. Gas Chromatography - Gas Chromatography (GC) is a common technique used to separate and identify volatile organic compounds.
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
Analytical Separations
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
GAS CHROMATOGRAPHY In gas chromatography (GC), the sample is injected onto the head of a chromatographic column and immediately vaporized. The components.
GAS LIQUID CHROMATOGRAPHY Principles Partition of molecules between gas (mobile phase) and liquid (stationary phase).
Gas Chromatography Refractive Index Polarimetry Next Lecture: Lecture Problem 8 Due Next Thursday: Quiz 7 in Lecture Next Week’s Office Hours: Tuesday.
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
Prof. aza Basic gas chromatography prof. aza Department of Pharmacy, Andalas University STIFI Perintis, Padang STIFAR, Pekan Baru STIFI Bhakti Pertiwi,
Dr. Ashraf M. M. Mahmoud, Associate professor
Gas Chromatography. In Gas Chromatography (GC), a gaseous mobile phase transports a gaseous solute through a long, thin column containing solid or liquid.
Organic Analysis Basic concepts. Elements and Atoms Fundamental building block of all substances is the element. Fundamental building block of all substances.
Gas Chromatography Oleh : Rohayati, S.Pd SMK Negeri 13 Bandung.
Chromatography.
M.PRASAD NAIDU Msc Medical Biochemistry, Ph.D Research scholar.
Drug detection and analysis
Experiments in Analytical Chemistry
Overview Determining Identity Quantitative Analysis
Chemical Ideas 7.6 Chromatography.
A guide for A level students KNOCKHARDY PUBLISHING
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
An analytical instrumentation process
Gas Chromatography.
Chromatography on Chiral Stationary Phases
An Introduction to Chromatographic Separations
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Chromatography on Chiral Stationary Phases
VAPOUR PHASE CHROMATOGRAPHY
Chromatography Daheeya Alenazi.
Gas Chromatography.
Gas Chromatography - Parts
A guide for A level students KNOCKHARDY PUBLISHING
GAS CHROMATOGRAPHY.
CHROMATOGRAPHY.
High performance liquid chromatography (HPLC)
Presentation transcript:

Lecture 4a Gas Chromatography

Introduction Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental labs (water, soil, air), and even in the popular TV culture (crime shows like NCIS (Major Mass Spec), CSI, etc.) Used for the quantitation of compounds Often combined with a mass spectrometer for identification using the fragmentation (by comparison with literature spectra) Traditional equipment requires the use of compounds that are stable enough to be vaporized without decomposition Mainly useful for small or non-polar molecules but not for large molecules i.e., proteins, polymers, etc. Sometimes polar molecules can be converted into derivatives by using i.e., trifluoromethylacetyl groups (F3CC≡O) to increase their volatility

Basic Setup Parts: Injection block, column, oven, detector, carrier gas, computer system The temperature of the injection block has to be above 200 oC to ensure a rapid and complete evaporation of the injected sample The temperature of the detector has to be 20-30 oC above the final column temperature to prevent condensation of the compounds

Theory of Gas Chromatography I The separation of compounds in a mixture is based on different polarities in a direct (interaction with stationary phase i.e., solubility) or indirect way (physical properties i.e., boiling point) The gas chromatography column consists of solid support that is covered with a high-boiling liquid in a thin capillary tube In the example above, compound “X” has a higher affinity towards the stationary phase compared to compound “O” Compound “O” elutes before compound “X” because it displays a lower boiling point and a weaker interaction with the stationary phase O X time ‖

Theory of Gas Chromatography II What influences the outcome in the GC run? The boiling point of the compound The higher the boiling point is, the slower the compound is going to migrate through the column resulting in a longer retention time and peak broadening The polarity of the compound compared to the polarity of the column The stronger the interaction of the compound with the stationary phase is going to be, which increases the retention time and peak broadening The column temperature A lower temperature allows for more interaction of the compound with the stationary phase resulting in longer retention times with improved separation but also peak broadening

Theory of Gas Chromatography III Carrier gas flow rate A higher flow rate allows for less interaction of the compound with the stationary phase resulting in shorter retention times with poorer separation Column length A longer retention time with better separation will be observed but also peak broadening due to increased longitudinal diffusion Amount of the material injected If too much material is injected, close peaks will overlap, which makes the identification (i.e., mass spectrometry) and the quantitation of the compounds more difficult if not impossible The conditions have to be adjusted for each separation problem, which will be very difficult if the compounds to be separated have similar very properties. The goal is to optimize the separation and the retention time for a given separation problem.

Detectors I FID (Flame Ionization Detector) Advantages: Disadvantages: It is very sensitive for most organic compounds (1 pg/s, DLL: 0.1 ppm) Low sensitivity for small molecules i.e., N2, CO, CO2, H2O Disadvantages: The sample is destroyed  It requires three gases (carrier gas (i.e., helium, argon, nitrogen), hydrogen and air/oxygen)

Detectors II TCD (Thermal Conductivity Detector) Advantages: The sample is not destroyed and can be collected after passing through the column Only one gas with a high thermal conductivity needed i.e., helium, hydrogen Disadvantages: The method possesses a significantly lower sensitivity compared to FID (usually 2-3 magnitudes, DLL: 10 ppm) ECD (Electron Capture Detector) It is very sensitive for chlorinated compounds i.e., TCDD, PCB, etc. and organometallic compounds (DLL: 0.1 ppb) Since a radioactive source is used, a special license and area is required for its operation Several carrier gases needed for the ionization i.e., argon/methane

Sample Identification Mass spectrometer Spiking: the sample is run with and without the addition of a spike, which is an authentic sample of compound to be identified Original chromatogram Spike B added If compound A was added as the spike, peak A would increase in area If the spike that was added to the mixture was not a compound in the mixture, an additional peak would be observed This method is semi-quantitative A B

Analysis of Gas Chromatogram I Complete chromatogram (HP-5, weakly polar, achiral) The gas chromatogram is dominated by the solvent peak The peak for (-)-isoborneol and (+)-borneol are not visible in the full chromatogram because of their low concentration (1 mg/mL)

Analysis of Gas Chromatogram II Expansions Expanded further

Chiral GC Column Modified version of b-cyclodextrin (Column: Restek (Rt-bDEXse), 30 m x 0.32 mm x 0.25 mm, Conditions: Ti=85 oC, isothermal) Peak areas in pairs are identical  racemic The assignments of the enantiomers were made on the reduction product of D-(+)-camphor that yields a mixture of (-)-isoborneol and (+)-borneol Rt-bDEXse, 30 mx0.32 mmx0.25 mm, Ti=85 oC, isothermal Isoborneol Borneol (+)-isoborneol (-)-isoborneol (-)-borneol (+)-borneol

Elution Sequence Camphor displays the highest vapor pressure of the three compounds at T=158 oC, a temperature that is close to the average temperature of the GC run (140 to 180 oC). Based on the vapor pressures, one can predict an elution sequence at temperatures above T=158 oC: camphor, isoborneol and borneol Compound p(351 K, 78 oC) p(431 K, 158 oC) camphor 1.07 mmHg 25.7 mmHg isoborneol 1.68 mmHg 24.1 mmHg borneol 0.30 mmHg 17.4 mmHg