Chapt. 25 Computed Radiography Digital terms are NOT uniform, but vary from one brand to the next!

Slides:



Advertisements
Similar presentations
DIGITAL RADIOGRAPHY.
Advertisements

Comparison of Film v. Digital Image Display. Process of data capture All image recording systems rely on differential absorption within the patient to.
IMAGE ARTIFACTS.
Digital Detectors n Cassette based Image Storage Phosphor (CR) n Image Intensifier n Scanned Projection n Direct Digitizing (Full Field) –CCD Camera –Selenium.
Radiologic Technology
RAD 350 Chapter 16 Digital Radiography Many types/names for the digital imaging processes and devices.
The Field of Digital Radiography
Digital Radiography.
RAD 354 Chapt. 28 The Digital Image Spatial resolution Contrast resolution Contrast-detail curve Pt. dose considerations.
RAD 354 Chapt. 26 Digital Imaging Many types/names for the digital imaging to come – Types CR: Barium fluorohalide PSP SPR (scan projection RAD): Nal scintillator/photodiode.
RAD 354 Chapt. 24 Intro to Computer Science Historical dates of interest – 1939 first electronic digital computer built – 1944 first general purpose “modern.
Digital Radiographic Imaging 101
Digital Imaging CHAPTERS 1, 4-7 CARTER.
FILM ARTIFACTS.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
RAD 254 Chapter 11 Radiographic Film/Receptor
Digital Radiography Chapter 22. History of Digital Radiography Slower process of conversion because no pressing need to convert to digital radiography.
Direct Digital Radiography or Direct Capture Radiography Bushong Ch. 27.
Chapter 1 Introduction to Digital Radiography and PACS
Elsevier items and derived items © 2008 by Mosby, Inc
Most of the images recorded during conventional radiography are obtained with film/screen combination image receptors. Which in lessens the patient dose.
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
Unit III Creating the Image. Unit III Creating the Image.
Chapter 6: Digital Radiographic Imaging
Quality Control.
FILM PROCESSING GOING BUT NOT OBSOLETE YET. LET’S REVIEW NAME SOME COMPONENTS OF THE STRUCTURE OF THE FILM NAME SOME COMPONENTS OF THE STRUCTURE OF THE.
Lecture (2). 2 1.Explain how to produce x-rays and discuss its properties 2.List the basic components of the radiographic machine and identify primary.
Image Receptor Systems
DIGITAL PROJECTION RADIOGRAPHY COMPUTED RADIOGRAPHY
Digital Radiology. 2 Aim : To become familiar with the digital imaging techniques in projection radiography and fluoroscopy.Aim : To become familiar with.
Computed Radiography.
RAD 254 Digital Imaging Basic Elements of Digital Imaging CR/DR.
Digital Imaging. acronyms 1.PSP 2.CRT 3.ADC 4.IP 5.CR 6.DR 7.PACS 8.SNR 9.CNR 10. CCD 11. FOV 12. LUT 13. DICOM 14. RIS 15. HIS 16. TFT 17. DQE 18. DAP.
Computed Radiography By Prof. Stelmark. Presently, an acceleration in the conversion from screen-film radiography (analog) to digital radiography (DR)
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
Image Capture. X-Ray X-Ray Generation Film Can be exposed directly to x-ray, but sensitivity is very low Nitrate – 1910s to 1930s Acetate – 1920s to.
Digital Radiography and PACS By Professor Stelmark.
Review CR & DIGITAL IMAGING (1) 2012 – RT 244 wk 15
Registry Review Digital Imaging Considerations (Image Production and Evaluation)
Sensitometry By Prof. Stelmark. The study of the relationship between the intensity of exposure of the film and the blackness after processing is called.
Image Quality Q&A. RAPHEX Diagnostic Question 2001 D9: The imaging system which is best for visualizing small high contrast objects is: A. Computed tomography.
Digital Imaging.
RAD 254 Chapter 13 Intensifying Screens Physical purpose: to convert x-ray photons into light photons (done at the phosphor layer)
IMAGE RECEPTORS. Follow the Sequence- Film System Tube Tube Patient Patient (bucky) or non-bucky (bucky) or non-bucky Cassette Cassette INTENSIFYING SCREEN.
RAD 254 Chapt. 26 Digtal Imaging Many types/names for the Digital imaging to come.
DIGITAL IMAGING.
Digital Radiology Dr M A Oghabian Medical Physics Group Tehran University of Medical Sciences
Image Receptor Unsharpness By Professor Stelmark.
DIGITAL RADIOGRAPHY.
Direct Digital Radiography or Direct Capture Radiography
Acronyms. A SEQUENCE OF COMPUTER OPERATIONS FOR ACCOMPLISHING A SPECIFIC TASK Algorithm.
History of digital radiology 1980 Kinos L.T. ET all developed a portable radiographic X-ray camera made of tantalum and aluminum. Digital radiography.
B ASIC P HYSICS OF D IGITAL R ADIOGRAPHY By : Maisa Alhassoun Recommended Book: Walter Huda, REVIEW OF RADIOLOGIC PHYSICS &
Computed Radiography By Prof. Stelmark.
Fundamentals of Digital Radiology
Comparison of Film v. Digital Image Display
Imaging Characteristics
Digital Imaging.
כיצד נרכשת התמונה בסרט הרנטגני?
Computed Radiography Feb.
Digital Imaging CHAPTERS 1, 4-7 CARTER.
Principles of Radiographic Exposure
Principles of Radiographic Exposure
COMPUTED RADIOGRAPHY -Dr.SHEFALI MESHRAM
Chapter 6 Cassetteless Equipment and Image Acquisition
COMPUTED RADIOGRAPHY.
Digital Imaging.
Digital Imaging.
Digital radiography.
Presentation transcript:

Chapt. 25 Computed Radiography Digital terms are NOT uniform, but vary from one brand to the next!

DR introduced in 1981 Fuji introduced “digital imaging” in 1981 –Many forms of digital CR DR

CR Terms PSL= photostimulable luminescence PSP=photostimulable phosphore SPS=storage phosphor screen IP=imaging plate SP=storage phosphore PMT=photomultiplier tube PD=photodiode

PSL & PSP Photostimulable luminescence (PSL) –Emit light promptly AND at a later time! Photostimulable phosphor (PSP) – barium fluorohalide looks physically like an intensifying screen BUT stores the latent image via metastable electrons (STORAGE PHOSPHOR SCREENS) SPSs

The “imaging plate” The PSP screen is inside a “rigid” (not really as they are brittle and do break easily – much more so than film/screen cassettes) cassette The actual imaging receptor is called the IMAGING PLATE

Light Stimulation Emission Process similar to Thermosluminescent dosimetry (TLD – film type badges for dosimetry) They are either “powder” (like an intensifying screen crystal) OR arranged like “needles” i.e. Powder PSP or Needle PSP

Thoughts on PSP’s Powder vs “needle” Highly sensitive to RADIATION = easily fogged!!!

CR Reader The physical receptor - cassette is “loaded” into the reader –IP is removed and moves along the LONG AXIS of the IP!!! (slow scan) –As the IP is moved, a deflection device is used to deflect the LASER beam across the IP (fast scan) IP doesn’t really separate from the cassette and doesn’t go around “rollers” etc.

CR Optical feature To properly and precisely translate EACH metastable electron (latent image forming charge) in a PRECISE fashion to provide for great SPATIAL RESOLUTION

Compare and contrast film-screen to CR techniques Film- screen has much LOWER latitude than CR!!! –As such – a WIDE variety of techniques can be used = Burn em up BURNIE!!!! If in doubt – “BURN IT OUT” Compare Characteristic curves for each:

Image noise Box 25-1 SAME as screen-film noise PLUS Box 25-2 –Mechanical defects – due to the scan drivers –Optical defects – laser, stimulating beam, light quanta emission and collected –Computer defects – electronic noise; too few sampling; too little quantization