Image Capture. X-Ray X-Ray Generation Film Can be exposed directly to x-ray, but sensitivity is very low Nitrate – 1910s to 1930s Acetate – 1920s to.

Similar presentations


Presentation on theme: "Image Capture. X-Ray X-Ray Generation Film Can be exposed directly to x-ray, but sensitivity is very low Nitrate – 1910s to 1930s Acetate – 1920s to."— Presentation transcript:

1 Image Capture

2 X-Ray

3 X-Ray Generation

4 Film Can be exposed directly to x-ray, but sensitivity is very low Nitrate – 1910s to 1930s Acetate – 1920s to mid 1960s Polyester – mid 1950s to present Topcoat Emulsion Adhesive Base

5 Intensifying Screens Intensifying Screen Intensifies available x-ray light X-rays

6 Film PACS Film is the detector and storage…..“The PACS”

7 Digital Imaging Ultrasound Nuclear Medicine Computed Tomography Magnetic Resonance

8 Computed Radiography Digital Image Capture

9 Expose plate Drop into Reader PMT scans plate Converts to Digital Sends to monitor Digital Image Capture - CR

10 Imaging PlateExcited Phosphor High Energy Low Energy X-ray Energy Digital Image Capture - CR

11 High Energy Low Energy Laser Scanning Creating Visible Light, Digital Capture Excited Phosphor Digital Image Capture - CR

12 High Energy Low Energy Bright White Light Excited Phosphor Digital Image Capture - CR

13 Flat Panel Detector Digital Image Capture

14 Image Capture - DR Flat Panel Detector Image info captured Converts to Digital Sends to monitor

15 TFT Array CsI Photodiode X-rays TFT Array GOS Photodiode X-rays Discussion of CsI vs. GOS Csi focuses scintillator light to TFT High Image quality GOs scatters produced light to TFT causing reduced image quality Flat Panel Technology - Cross Section

16 Technology Review

17 Flat Panel Technology - Cross Section

18 Digital Image Capture - Flat Panel 8 Million X-ray Energy High Energy Low Energy

19 High Energy Low Energy X-ray Energy 8 Million Digital Image Capture - Flat Panel

20 Digital Radiography Performance

21 4096 Imaging Performance Digital Receptors

22 4096 Speed Digital Receptors

23 Digital Radiography

24 Image Generation - Today Using 100 yr old technology……Vacuum Tubes Heats a negatively charged metal filament to1000º C Combination of heat and charge releases electrons Strikes a positively charged electrode X-rays created by the energy of the impact

25 Image Generation - Future Electron Field Emission A myriad of carbon nano-tubes on a platform Compact source of x-rays that can be controlled with great precision, built into an array Each element programmed to fire when required