Www.hvac.vn Series RHP Temperature and Humidity Transmitter The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential.

Slides:



Advertisements
Similar presentations
Copyright ©2008 Honeywell International Inc. All rights reserved. Humidity Sensors.
Advertisements

HEALTHCARE BUILDING AUTOMATION
Thermostats The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
 lpha-2000 Series Process Controllers u  lpha pH/ORP 2000 u  lpha CON 2000 u  lpha DO 2000 Eutech Instruments.
HVAC Air Flow Measurement The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Introduction Enthalpy Wheel
Open Channel Flow Panel Meters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Chapter 4 — Control Principles Chapter 4 Control Principles Control System Components Sensors Controllers Controlled Devices Control Agents Control Functions.
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY. “Air conditioning is the control of the humidity of air by either increasing or decreasing its moisture content.
Paddlewheel Flow Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
01/14/2001Temperature and Humidity1 Temperature and Humidity Paul M. Fransioli, CCM AMS Short Course on Introduction to Measurements and Observation Techniques.
Hygrometry.
Understanding Weather Water in the Air Ch. 2 Sec. 1 p
Humidity Sensor Presented by: Key Kai Wong. Outline What is Relative Humidity Manufacturers of Humidity Sensor Humidity Sensor from Honeywell ( HIH series)
Humidity and Moisture Sensors
Humidity - Humidity sensors - Vapour pressure and dew point temperature - Soil moisture sensors - Leaf wetness sensors.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Submersible Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Electromagnetic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Important variables Water: Air: Conversion:
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
Temperature Control Loop
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Industrial Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Gas Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Handheld Digital Manometers The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Differential Pressure ATEX Enclosures The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Miscellaneous Test Equipment Combustion, Tachometers, Hygrometers The materials included in this compilation are for the use of Dwyer Instruments,
Ultrasonic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Powder & Bulk Level Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Temperature Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Water Detectors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Gas Mass Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Chapter 2: Section 1 Weather. Remember… Wind Water.
Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
Vibration Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Pressure Transmitters and Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Air Handler Demonstration The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
Flow Technology Overview The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Humidity The amount of water vapor in the air.. Expressed two ways Relative Humidity Dew Point.
Dew Point and Relative Humidity. What is Humidity? Humidity- the amount of water vapor (WV) in the air Relative Humidity- the % of WV in the air compared.
Lecture Objectives: Discuss the exam problems Answer question about HW 3 and Final Project Assignments Building-System-Plant connection –HVAC Systems.
Hygrometry Part 2.
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
Product Awareness, Commissioning & Maintenance
Fan Coil Controller FC/S 1.1
Temperature sensors Temperature is the most often-measured environmental quantity. This might be expected since most physical, electronic, chemical, mechanical,
資料擷取與感測器 應用實務.
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
HD SIGNAL CONDITIONER SERIES
Copyright SwissFlow B.V.
Industrial Instrumentation: Transmitters
Humidity.
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
Analog Room Command Module
NSA-7000 Stylish flush mount Network Sensors
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY
HD SIGNAL CONDITIONER SERIES
BME680 HUMIDITY SENSOR EDDIE SHEA RUCHEN TANG SEAN SWALVE.
Presentation transcript:

Series RHP Temperature and Humidity Transmitter The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc.

Introduction Combined humidity and temperature sensing The polymer capacitance humidity sensor is not affected by condensation, fog, high humidity, or contaminants

General Specifications Accuracy, RH: RHP-2XXX ±2% 10-90% 25°C RHP-3XXX ±3% 20-80% 25°C RHP-5XXX ±5% 20-80% 25°C Accuracy, Thermistor Temp Sensor: 25°C 77°F) Accuracy, RTD Temp Sensor: DIN Class B; 0°C 32°F) Output signal: 4 to 20 mA/ 0 to 5 mA max

General Specifications RH Sensor: Capacitance polymer Temperature Sensor: Types 1, 2, 3: Solid state band gap Curves A, B, C: Thermistor Curves D, E: Platinum RTD DIN 385 Enclosure: Duct mount: PBT; OSA: Polycarbonate. Enclosure Rating: NEMA 4X (IP66) for OSA mount only Agency Approvals: CE

Relative Humidity Relative humidity (RH) is the amount of water vapor in a volume of air as a proportion of the amount of water vapor the same volume of air will hold at saturation (100% RH) at any given temperature

Capacitance Polymer Humidity Sensors Works similar to a plate capacitor Consists of hygroscopic polymer between two electrodes One of the electrodes is a sensing surface Porous to allow water to pass in and out of polymer Keeps out condensation and contaminants As polymer absorbs water, its dielectric constant changes, creating changes in capacitance proportional to changes in relative humidity

Features Sensor RH range: 0-100% 15 second response time Sensor recovers 100% from saturation Factory calibrated, field replaceable sensors available

Features Wall mount Optional remote or integral LCD display Universal current/voltage output for humidity/temp. Resistive temp. Outputs available Replaceable sensors Well ventilated for more accurate measurements We couldn’t find an updated picture. This was from the website. -MS

Features Duct mount Weather resistant PBT construction Dual temp./RH output Optional display reads both temp. And RH Field replaceable sensor cap of filter Twist-off cover, no screws Available with membrane or sintered filter

Features Outside air NEMA 4X / IP66 housing Field replaceable sensor Multiple knock outs for conduit Screws anchored inside lid top Available w/ SS sintered filter or radiation shield

Applications Wall mount humidity/temp. Mounted in a room – sends signal to controller on vav system to adjust amount of air flow supplied to the space

Duct mount humidity/temp. Monitors the humidity of the air after a humidifier and the humidity in return duct for economizer applications. Applications

Applications Outside air humidity/temp. Used to determine if additional hot or cold water is needed to feed AHU