Chapter 5a. 5a-2 Single Twisted Pair Jacket Four pairs (each pair is twisted) are enclosed in a jacket. Copyright 2011 Pearson Education, Inc. Publishing.

Slides:



Advertisements
Similar presentations
How to wire Ethernet Cables. Tools Required CAT 5 Cable - bulk Category 5, cable RJ45 Ends Crimper for RJ45 Wire Cutters - to cut and strip the cable.
Advertisements

HOW TO MAKE UTP CAT-5/5e CABLE
Building a T568B Network Cable Examples of good and bad cables Identification of components Critical areas of cable.
+ Straight-Through Cable Construction Lab 4. + Data Transmission In data transmission system, the transmission medium is the physical path between transmitter.
1 Copyright © 2014 Pearson Education, Inc. Publishing as Prentice Hall. by Mary Anne Poatsy, Keith Mulbery, Eric Cameron, Jason Davidson, Rebecca Lawson,
Hands On: Cutting and Connectorizing UTP Chapter 3a Panko’s Business Data Networks and Telecommunications, 6 th edition Copyright 2007 Prentice-Hall May.
CS335 Networking & Network Administration Thursday April 1.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
Chapter 32 Serway & Jewett 6 th Ed.. 9/22/04 What happens when we close the switch? I t I = 0I = I o R E B.
Chapter 7 Transmission Media
Chapter One Customer Focus and Managing Customer Loyalty
1 Copyright © 2014 Pearson Education, Inc. Publishing as Prentice Hall. by Mary Anne Poatsy, Keith Mulbery, Eric Cameron, Jason Davidson, Rebecca Lawson,
Network Cabling. Introduction Cable is the medium through which information usually moves from one network device to another. There are several types.
Wiring MVRT 2010 – 2011 Season. Table of Contents Wire stripping Crimping Soldering.
The making of Ethernet Standards For the Ethernet Cabling & PoE (power-over-Ethernet).
Cisco – Semester 1 – Chapter 9 Preview Review. Behavioral Objectives Document all work –Do it as work proceeds –Same as chapter 8 guidelines –Don’t forget.
Physical Layer Data Encoding Transmission media Signals Bits to signal transformation  Timing (bit rate)  Synchronization.
Crafting a Cat5e Cable Scott H. Bowers. Materials Raw Cat5e cable ~50 feet. Wire Cutter/Cable Stripper RJ-45 Crimper Ethernet tester RJ-45 terminators.
1 PATCH CORDS BASIC TELECOMMUNICATIONS. 2 Telecom Cabling Even with the advent and deployment of wireless technology, with its inherent problems of size,
Chap 9 Structure Cabling Project Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
Connecting to the Internet through an ISP Networking for Home & Small Business.
GO! All In One 2/E By: Shelley Gaskin, Nancy Graviett, Debra Geoghan Chapter 5 Using Internet Explorer, Microsoft Cloud Computing, and OneNote Copyright.
NETWORK CABLING Chapter 2
Communication channels and transmission media
Physical Transmission
Component 9 – Networking and Health Information Exchange Unit 2-2 Network Media and Hardware Communication Devices This material was developed by Duke.
Crossover Cable Construction
Modern Ethernet Chapter 6. Contents Define the characteristics, cabling, and connectors used in 10BaseT and 10BaseFL Explain how to connect multiple Ethernet.
Transmission Media The physical pathways that connect computers and devices on a network.
SYSTEM ADMINISTRATION Chapter 4 Network Media, Connectors, and Their Characteristics.
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
PREPAIR BY :  MOHD SHARIFUDDIN B SAHABUDIN  12DEP11F11006  IMAN BT ABDULLAH  12DEP11F1002  MUHAMMAD MUIZZUDDIN BIN ZAINOL ABIDIN  12DEP11F1003 
Chapter 9 Review Structured Cabling Project. Chapter 9 Focus The focus of this chapter is standards for networking media. You read that when RJ-45 jacks.
Bits (0s and 1s) need to be transmitted from one host to another. Each bit is placed on the cable as an electrical signal or pulse. On copper cable the.
GO! with Office 2013 Volume 1 By: Shelley Gaskin, Alicia Vargas, and Carolyn McLellan Access Chapter 3 Forms, Filters, and Reports.
Module 3: Networking Media Safe Handling and User of a Multimeter Voltage Measurement Resistance Measurement Series Circuits 3.1.9a.
Cabling Project. Your first responsibility, as the network designer, will be to have your client specify, in writing, the desired outcome of the project.
Making and Testing Cat 5 Cables. EIA/TIA-568A and 568B Straight Through and Crossover Cables EIA/TIA-568 Commercial Building Telecommunications Wiring.
Chapter Six Competitor Analysis and Sources of Advantage.
Project On Ethernet Cable Building & Video Recording James Maclean & Stephen Craig.
Page 1 - © Richard L. Goldman RJ-45 Termination ©Richard L. Goldman June17, 2002.
1 Discovery 2, Ch 4 Notes. 222 Cabling Standards Standards ensure that networks perform to expectations US—IEEE & ANSI/TIA/EIA Canada—CSA (Canadian Standards.
Network Anatomy By: Roland J. Boutte. Ethernet Cable cable used to connect computing devices together directly. two hosts or two switches to each other.
Day 5 Wires. Why wire? Conducts Electricity and directs it to a location. Cheap! Easy to run.
Chapter 2.  Upon completion of this chapter, you should be able to:  Select & install cables for connecting to a dial-up network  Select & install.
How to Make an Ethernet CAT5 RJ45 Crossover Cable
© 2012 Pearson Education, Inc. publishing Prentice Hall. Note 9 The Product Life Cycle.
Telecommunications and Networking
Network Tools and Cabling. Network Tools RJ means "Registered Jack" This is a plastic connector that looks like a large telephone-style connector. Used.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
GO! with Office 2013 Volume 1 By: Shelley Gaskin, Alicia Vargas, and Carolyn McLellan PowerPoint Chapter 3 Enhancing a Presentation with Animation, Video,
Wildland Fire Information and Technology Making and Testing Cat 5 Cables.
T. Hajer Brahim & T. Rania Alakazalah U.Y: 1435/1436 H.
UTP cabeling. Introduction This document shows how to properly construct a Crossover network cable. This cable can be used to directly connect two computers.
Copyright © 2006 Heathkit Company, Inc. All Rights Reserved Introduction to Networking Technologies The Ethernet 10BaseT LAN.
Lecture 2 unit 1.
Copyright © 2013 Pearson Education, Inc. Publishing as Prentice Hall. 1 Skills for Success with Office 2010 Vol. 1, 2e PowerPoint Lecture to Accompany.
How to wire Ethernet Cables. Tools Required CAT 5 Cable - bulk Category 5, cable RJ45 Ends Crimper for RJ45 Wire Cutters - to cut and strip the cable.
ETHERNET CABLE TYLER THORNBURG LTEC STRIPPING AND CUTTING First you will need to strip the wire. I used scissors to cut off the rubber around.
Understand Network Media Types Part 2 LESSON 2.3_B Networking Fundamentals.
Constructing/Testing 4-Pair Cabling Systems
CREATING A 568A, 568B, OR CROSSOVER CABLE Creator:Dennis Groseclose
How to wire Ethernet Cables
Level 2 Diploma Unit 10 Setting up an IT Network
Hands On: Cutting and Connectorizing UTP
Hands On: Cutting and Connectorizing UTP
Ethernet Cable Local Area Networks.
Fundamentals of Computer Networks
Hands On: Cutting and Connectorizing UTP
LAN Cabling CCNA Instructor Training Course October 12-17, 2009
Presentation transcript:

Chapter 5a

5a-2 Single Twisted Pair Jacket Four pairs (each pair is twisted) are enclosed in a jacket. Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

5a-3 The cord terminates in an 8-pin RJ-45 connector, which plugs into an RJ-45 jack in the NIC, hub, or switch. Pin 1 on this side RJ-45 Jack RJ-45 Connector Unshielded (no metal shielding around the 4 pairs) Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

5a-4 RJ-45 Connector 4 Pairs Separated Pen Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Has push-in prong connectors for 8 wires in back 5a-5 Front: RJ-45 Jack Back: 8 Wire Connectors Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Solid-Wire UTP ◦ Each of the eight wires is a solid wire surrounded by insulation. ◦ Solid wires have low attenuation and so can reach 100 meters. ◦ Easy to connectorize (add connectors to). ◦ Brittle and easy to break if handled roughly. Not good for runs through open office areas. 5a-6 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Stranded-Wire UTP ◦ Each of the eight “wires” is really several thin strands of wire surrounded by insulation. ◦ Flexible and rugged: ideal for running around an office area. ◦ Higher attenuation than solid-wire UTP so can only be used in short runs—up to about 10 meters. 5a-7 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Patch Cords ◦ Cut to popular lengths and connectorized at the factory ◦ Tested for quality ◦ Use stranded-wire UTP, which is sufficiently rugged for open office areas ◦ TIA/EIA-568 specifies patch cords for the run from the wall jack to the desktop because it is rugged and flexible 5a-8 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Bulk Wire ◦ Comes in spools of 50 meters or more ◦ Can be cut to precise lengths needed to connect devices ◦ Solid-wire UTP for longer distance and to make connectorization easier ◦ Cut, connectorized, and tested by the user, by the organization, or by a LAN installer ◦ Focus of this chapter 5a-9 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Cut a desired length of UTP.  Make it a little longer than you need. ◦ Adding a connector can take a few inches. ◦ If the connectorization doesn’t test well, you will have to cut the end and install a new connector. ◦ UTP cord should never be pulled tautly; it can break if subjected to pulls. Should be slack after installation. 5a-10 Now do it! Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 You must strip the jacket 3 to 5 cm (1 to 2 inches) at each end. 5a-11 Stripped Jacket Stripper Put Cord Here Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Stripper scores the jacket (cuts into the jacket without cutting through it) to avoid damaging the wires inside the jacket.  Stripper is rotated once around the cord to score it evenly.  The tip of the cord is pulled off after the scoring, exposing 3 to 5 cm (1 to 2 inches) of the wires. 5a-12 Now do it! Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 There are orange, green, blue, and brown pairs.  Each pair has one wire with solid-color insulation and one wire that is white with bands of the pair’s color.  These wires will be placed in a particular order in the RJ-45 connector. 5a-13 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 There are two popular color schemes in TIA/EIA-568. ◦ T568A and T568B. ◦ T568B is the most commonly used color scheme in the United States; we will use it.  Note that T568A is a part of the TIA/EIA- 568 standard, as is T568B. 5a-14 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

PinColor 1White-Orange 2Orange 3White-Green 4Blue 5White-Blue 6Green 7White-Brown 8Brown 5a- 15 Pin 1 on this side on both ends of the cord RJ-45 Jack RJ-45 Connector T568B Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

PinColor 1White-Orange 2Orange 3White-Green 4Blue 5White-Blue 6Green 7White-Brown 8Brown 5a- 16 T568B NIC Transmits on 1 and 2 (Orange) NIC Receives on 3 and 6 (Green) Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

PinColor 1White-Orange 2Orange 3White-Green 4Blue 5White-Blue 6Green 7White-Brown 8Brown 5a- 17 T568B Fan out the wires in their correct order, with white- orange on the left and brown on the right. Now do it! Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Cut the wires straight across so that no more than 1.25 cm (a half inch) of wires are exposed from the jacket. ◦ This controls terminal cross-talk interference.  Be sure to cut straight across or the wires will not all reach the pins when you push them into the connector in the next step! 5a-18 Now do it! Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

5a-19 Back: Hole for UTP Cord Spring Clip to Hold Connector in Front: Connector Pins Strain Relief Area for Crimping Top Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Hold the RJ-45 connector away from you (with the hole in the back toward you) and the spring clip down.  Insert your wires into the connector, white-orange on left.  Push the wires all the way to the end. 5a-20 Now do it! PinColor 1White-Orange 2Orange 3White-Green 4Blue 5White-Blue 6Green 7White-Brown 8Brown Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Check Wire Order ◦ Are the wires in the correct order? ◦ Hint: as a rough first check, the 1 st, 3 rd, 5 th, and 7 th wires from the left should be mostly white. ◦ If not, reinsert them in the correct order. 5a-21 Now do it! PinColor 1White-Orange 2Orange 3White-Green 4Blue 5White-Blue 6Green 7White-Brown 8Brown Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

5a-22 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Get a good crimper.  Cheap ones often fail to make a good connection.  Should have a ratchet for tightening without breaking the connector. 5a-23 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Press down to make a good connection. If you press too lightly, the connection will not work.  Crimping forces the pins on the front of the RJ-45 connector though the insulation, into each wire.  This also crimps the cord at the back end of the connector for strain relief to keep the cord from pulling out if the cord is pulled. 5a-24 Now do it! Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 White-orange is on the left (in Pin 1) at BOTH ENDS of the cord. ◦ You do NOT reverse the order at the other end! 5a-25 Pin 1 on this side RJ-45 Jack RJ-45 Connector Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 After you have connectorized both ends, test your cord.  Misconnection is very common, so every cord must be checked.  Inexpensive continuity testers make sure wires are connected electrically and in the right order.  Expensive performance testers test for the quality of propagation. 5a-26 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Continuity Tester ◦ Test for wires being in right slots and making good contact. ◦ Place connectors of cord into two ends. ◦ Hit Test button. ◦ Did it work? 5a-27 Now do it! Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 If It Didn’t Work ◦ Be sure you understand the problem. ◦ If an open connection, one or more of the wires was not pushed all the way to the end or the crimping did not push the pin all the way through the insulation. Next time, cut the wires straight across and crimp very firmly. ◦ If miswired, see where it was miswired. ◦ Cut off the ends of the cord and reconnectorize. 5a-28 Now do it! Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

 Signal Testers ◦ Expensive testers ◦ Test for signal quality ◦ Test for breaks with time domain reflectometry (TDR), which sends signals and looks for reflections that indicate breaks 5a-29 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall

5a-30 Copyright 2011 Pearson Education, Inc. Publishing as Prentice-Hall All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. Printed in the United States of America. Copyright © 2011 Pearson Education, Inc. Copyright © 2011 Pearson Education, Inc. Publishing as Prentice Hall