Www.DoctorVermeulen.com A Comparison Between Two Leading Stereotactic Platforms in the Treatment of Multiple Metastases Sandra Vermeulen MD, James Raisis.

Slides:



Advertisements
Similar presentations
FACET - European Journal of Cancer Care March 2006 slides available at: Stereotactic radiosurgery Gordon, K. 1.
Advertisements

10th Annual Lung Cancer Conference Radiation Oncology
Do you know what ’ s in people ’ s head?. Brain tumors 72 male 72 male HPI: presents to E.R. with history of confusion, change of personality, left sided.
Para-spinal Tumors Encircling the Spinal Cord IMRT Comparison of Several Target Definitions.
TREATMENT PLANNING PHOTONS & ELECTRONS Karen P. Doppke 3/20/2007.
CyberKnife Truly a Technological Advancement Mohammad AlBader.
Radiosurgical Planning. Radiosurgery Tumor = bad Brain = good Critical structures = good and sensitive Minimally invasive procedure that uses an intense,
Stereotactic Radiosurgery Jimmy Johannes Physics 335 – Spring 2004 Final Presentation
Stereotactic surgery Radiosurgery Gamma Knife
Dos 741 Protocols & Studies in Rad Onc 2011 Charles Poole
Stereotactic RadiologyStereotactic Radiology By: Jeremy Lishner.
Surgery Surgery is the initial therapy for nearly all patients with brain tumors and can cure most benign tumors, including meningiomas Goal : to remove.
Innovation/Impact: By designing a simulated human shaped (anthropomorphic) plastic phantom with targets, organs at risk (OAR) and heterogeneities, the.
Breast Cancers With Brain Metastases are More Likely to be Estrogen Receptor Negative, Express the Basal Cytokeratin CK5/6, and Overexpress HER2 or EGFR.
Radiotherapy Planning for Esophageal Cancers Parag Sanghvi, MD, MSPH 9/12/07 Esophageal Cancer Tumor Board Part 1.
Shannon M MacDonald 1, Salahuddin Ahmad 2, Stefanos Kachris 3, Betty J Vogds 2, Melissa DeRouen 3, Alicia E Gitttleman 3, Keith DeWyngaert 3, Maria T Vlachaki.
Comparison of MRI Perfusion and PET-CT in Differentiating Brain Tumor Progression from Radiation Injury after Cranial Irradiation T. Jonathan Yang, M.D.
Vertebral Fractures After Stereotactic Ablative Radiotherapy of Lung Tumors Todd A. Aguilera MD PhD 1, Nicholas Trakul MD PhD 2, David B. Shultz MD PhD.
NECN Lung NSSG April 2012 Managing Solitary Brain Metastases from NSCLC Dr Paula Mulvenna Consultant Clinical Oncologist Northern Centre for Cancer Care.
Working Together: How to Build a Radiosurgical Center and Partnership Sandra Vermeulen, M.D. Seattle Cyberknife Center at Swedish Cancer Institute Seattle,
Learn More At: Northwest Hospital Gamma Knife Center Dr. Sandra Vermeulen, M.D. Swedish Cancer Institute Northwest Hospital Gamma.
Mariah Cordie and Deb Norrell. What is CyberKnife?  World’s first and only robotic radiosurgery system designed to treat tumors throughout the body non-
Comparison of Rectal Dose Volume Histograms for Definitive Prostate Radiotherapy Among Stereotactic Radiotherapy, IMRT, and 3D-CRT Techniques Author(s):
1 Overview of Gamma Knife ® Surgery Dr. Sandra Vermeulen, M.D. Swedish Cancer Institute Northwest Hospital Gamma Knife Center Seattle, Washington Learn.
Learn More At: Dose-Response and Dose- Complications Relationships in Stereotactic Radiosurgery for Trigeminal Neuralgia Sandra.
Decreased Risk of Radiation Pneumonitis With Coincident Concurrent Use Of Angiotensin- Converting Enzyme Inhibitors In Patients Receiving Lung Stereotactic.
The RPC Proton Therapy Approval Process
Learn More At: CyberKnife Radiosurgery in the Treatment of Early and Advanced (Oligo-Metastases) Breast Cancer Sandra Vermeulen,
12/09/2011Position Sensitive Detectors 91 &. 12/09/2011Position Sensitive Detectors 92 Tracking of Moving Fiducial Markers during Radiotherapy using a.
Radiological Physics Center David Followill, Ph.D. and RPC Staff.
The Radiological Physics Center’s Anthropomorphic Quality Assurance Phantom Program Carrie F. Amador, Nadia Hernandez, Andrea Molineu, Paola Alvarez, and.
Conflict of Interest Declaration: Nothing to Disclose Presenter: Sophie Lamoureux Title of Presentation: A Comparison of Stereotactic Body Radiotherapy.
Gamma Knife Kelly & Tarah.
M ETHODS Median dose was 22Gy (range: ) in 1 to 5 fractions Median treatment volume was 12.6 cc (range: ). Assessed for eligibility.
REGULATORY HISTORY of ZOMETA and AREDIA JAW OSTEONECROSIS (ONJ) Oncologic Drug Advisory Committee March 4, 2005 Nancy S. Scher, M.D.
Saad El Din I, M.D *, Abd El AAl H, M.D *, Makaar W, M.D *, El Beih D, M.Sc †, Hashem W, M.Sc * *Department of Clinical Oncology and Radiotherapy, Kasr.
Purpose/Objectives: A percentage of patients receiving stereotactic radiosurgery (SRS)/fractionated stereotactic radiotherapy (FSRT) for Schwannomas initially.
Reducing excess imaging dose to cancer patients receiving radiotherapy Adam Schwertner, Justin Guan, Xiaofei Ying, Darrin Pelland, Ann Morris, Ryan Flynn.
Surgery for Metastatic Brain Tumor from Breast Cancer
SRS/SRT AUDIT Dr Sarah Pascoe Neuro-Oncology Study Day 8 th June 2007.
THE IMPLEMENTATION OF ABLATIVE HYPOFRACTIONATED RADIOTHERAPY FOR STEREOTACTIC TREATMENTS IN THE BRAIN AND BODY: OBSERVATIONS ON EFFICACY AND TOXICITY IN.
Evaluating the Clinical Outcomes of Sixty-Three Patients Treated with Gamma Knife as Salvage Therapy for Glioblastoma Multiforme Erik W Larson, Halloran.
Neurosurgery Department Shuang Ho Hospital New Taipei City, Taiwan Wei-Lun Lo, M.D. THE APPLICATION OF PERFEXION GAMMA KNIFE RADIOSURGERY FOR INFRA-SKULL.
Treatment Chart Record of patients radiation therapy history. Must contain: History and diagnosis Rationale for treatment Treatment plan Consent Documentation.
Extending intracranial treatment options with Leksell Gamma Knife® Icon™ Key Statements from Customer Perspective by University Medical Centre Mannheim.
Rationale in the Single Session Treatment of Lung Tumors
Evaluation Of RTOG Guidelines For Monte Carlo Based Lung SBRT Planning
Salvage Stereotactic Body Radiotherapy (SBRT) Following In-Field Failure of Initial SBRT for Spinal Metastases  Isabelle Thibault, MD, Mikki Campbell,
Leksell Gamma Knife® Icon™
Pain Control by Image-Guided Radiosurgery for Solitary Spinal Metastasis  Samuel Ryu, MD, Ryan Jin, MD, Jian-Yue Jin, PhD, Qing Chen, PhD, Jack Rock, MD,
Colorectal SSG: SABR and Oligometastatic Disease
Junliang Liu, M.D., M.Sc. Ph.D., FRCPC Assistant Professor
Left Posterior Superior Right Anterior Inferior
The Role of Cyberknife Stereotactic Body Radiation Therapy in the Treatment of Localized and Advanced Prostate Cancer David M. Spellberg M.D., FACS Naples.
Fig. 4. Percentage of passing rate between clinical and 544 plans.
Radiosurgical Planning
Doc.Ing. Josef Novotný,CSc
Insert tables Insert graphs Insert figure
Novel Technique for Early Detection of Pancreatic Cancer
Dosimetry of Alternative Techniques for Accelerated Partial Breast Irradiation Hanh Pham, B.S, CMD, Thanh Nguyen, BS, Christina Henson, MD, Salahuddin.
LEKSELL GAMMA KNIFE PERFEXION
CK RS for non-resectable pancreatic tumors
Re-irradiation with VMAT for progressive brain metastases after previous whole brain radiation for radionecrosis risk avoidance. Marilena Theodorou, MD.
Treatment Overview: The Multidisciplinary Team
Intensity-Modulated Radiotherapy for Lung Cancer: Current Status and Future Developments  Clara Chan, MD, Stephanie Lang, MSc, Carl Rowbottom, PhD, Matthias.
Surgical Management of Brain Metastases
Rarer Bone Tumors Thomas F. DeLaney, M.D. Co-Director: Sarcoma Program
GHG meeting at ESTRO36 May, 2017
Impact of approaches for clinical and radiological monitoring on predicting of short-term and long-term disability outcomes in multiple sclerosis Brian.
Examples illustrating the study definitions of groups A, B, and C
Presentation transcript:

A Comparison Between Two Leading Stereotactic Platforms in the Treatment of Multiple Metastases Sandra Vermeulen MD, James Raisis MD, Francisco Li MS, Per Kjäll PhD Northwest Hospital Gamma Knife, Seattle Seattle Cyberknife, Seattle R & D Physics, Eletka Instruments AB, Stockholm, Sweden

Radiosurgical Stereotactic Platform Objectives Precision Reproducibility Operator Friendly Patient comfort Treatment time constraints Frame, No frame

Cyberknife Credentials Approved by the FDA since 2001 More than 120 hospitals and medical centers provide CyberKnife technology Greater than 40,000 patients treated worldwide More than 400 peer review papers have been published Patient mix: 50% cranial, 50% extra-cranial

Cyberknife

Cyberknife Characteristic that Differ from Gamma Knife No immbolization frame –Real-time imaging required –Motion tracking required Capable of Fractionation –important if tumors engulf optic apparatus, spinal cord or other sensitive structures –Large tumors Extra-cranial targeting below the clavicle possible More staffing requirements More complex QA requirements

Brain Metastases Most patients have multiple lesions –MRI screening evaluations show 80% of patients have more than 1 metastases and 50% have 3 or more Many patients require more than one SRS session during the course of their disease Are CK and GK beam profiles the same for 1, 4 or 10 metastases?

Index Conformity (PIV/TV ratio) of Radiosurgical Treatment Plans Defined in the RTOG radiosurgical guidelines as a measure of the conformity of the Prescribed Dose (PIV) to the Target Volume (TV).

CK Cone Size Selection CK cone diameters (mm) available: –5, 7.5, 10, 12.5, 15, 20, 25, 30, 35, 40, 50, 60 An output factor is a ratio of dose for a given field size to that for a reference field size The output factor of the 5 mm cone has not been verified by the manufacturer

Extreme Brain Metastases Case MH is a 35y/o mother of 2 with a 4 year history of metastatic breast cancer involving brain, lung and bone. Systemic treatment includes chemotherapy, monoclonal antibodies and hormones SRS by CK has been given twice for BM (6 lesions have been treated over 2 years) Patient has been followed for 6 months with 10 intracranial lesions, all under 1 cm With a continued KPS of 80%, patient has refused WBRT because of the risk of dementia and the GK because of the frame placement

CyberKnife: Single Matrix and Multiple Matrix Plans Multiple Matrix Single Matrix

Cyberknife: Conformity Index Multiple and Single Matrix Multiple Matrix, 2.08 CI/2.17 nCI Single Matrix, 1.68 CI/1.70 nCI

Cyberknife: “Dose Stacking”

Gamma Knife: Single Matrix and Multiple Matrix Plans Multiple Matrix, nCI 1.04Single Matrix, nCI 1.14

Cyberknife Limitations in the Treatment of Multiple Metastases When treating more than 4 lesions, target conformity is lost and normal brain inclusion within lower non-prescription isodose volumes is increased. Output measurement of 5 mm cone not verified by manufacturer (most center do not treat tumors smaller than 4 mm’s)

Conclusion The dosimetry of either GK or CK in the treatment of < 4 metastases which are greater than 5 mm’s is comparable by radiosurgical standards When treating > 4 metastases, a larger number of lesions can be treated with GK than CK with better dosimetry and less normal brain inclusion within lower isodose volumes.