Non-Nuclear Methods for Compaction Control of Unbound Materials Nayyar Siddiki, M.S., P.E. Geotech Construction & Tech. Support Engineer Office of Geotechnical.

Slides:



Advertisements
Similar presentations
SOIL CLASSIFICATION Sarik Salim.
Advertisements

Earthworks Module #7 Prepared by Dr. Randy R. Rapp July 2005.
Soil Mechanics - II Practical Portion.
Soil Compaction.
Objectives Be able to use basic volume weight equations
 Soil compaction :  Compaction is the reduction in voids content due to air being forced out of the soil or dissolved in the soil water by mechanical.
Chemical Stabilization of Subgrades Section Engineers ’ Meeting Lake Cumberland State Resort Park March 5-7, 2013.
Mark Lindemann NDOR Geotechnical Engineer.  Background on previous field testing  Research – Non-nuclear field testing  Cost Savings of Going Non-Nuclear.
INTRODUCTION Session 1 – 2
1 Characterization of Granular Base Materials for Design of Flexible Pavements Lulu Edwards, Walter Barker, Don Alexander US Army Engineer Research and.
Review of Relative Density Principles v Relative Density principles apply to compaction of relatively clean, coarse- grained soils. v Relatively clean.
SOIL MECHANICS & TESTING
Chapter 3 Compaction. To improve the density and other properties of soil Increases the solid density improves strength Lowers its permeability Reduces.
Introduction to Soil Mechanics
Engineering Classification of Soils
Compaction Compaction - Densification of soil by removing air voids using mechanical equipment As compaction increases, the following occurs: –Strength.
Proctor Compaction Test for Maximum Dry Density
SESSION 3 Subgrade This module presents the concepts and methods of characterizing the subgrade for the purpose of concrete pavement design. It also highlights.
Textural Identification Properties of Soil Topic D.
Lecture (4). The presence of clay minerals in a fine-grained soil will allow it to be remolded in the presence of some moisture without crumbling. If.
ENCI 5791 Compaction In-situ soils used as: –Bases for the construction of highway pavements –embankments or leveling material for construction projects.
 Embankment Construction – LOTs  What is the maximum length of a LOT? Mainline pavement lanes, turn lanes, ramps, parking lots, concrete box.
Mix Design Review.
1 Overview CQC Asphalt Specifications.  Payment based on Contractor’s Quality Control tests.  FDOT runs verification tests at a lesser frequency. 
Asphalt Quality Assurance Program
SB Certification for Mixture-Based Specification for Flexible Base Summary of Spec Test Procedures Actions to Take for Non-Compliance October 31, 2012.
Unified Soil Classification System Training
Earthwork: Use of Fine Grained & Granular Material.
EARTHWORK RECORD SYSTEM
COMPACTION Topic COMPACTION Presented to Dr. Ayub Elahi Presented by Group leader. M.Zeeshan haider yousaf Zia. # 14 Haider ayub # 13 Bilal ansari #35.
Soil Compaction and Pavement Design
7. Soil Compaction (Das, chapter 6)
INNOVATIVE INTEGRATED METHODOLOGY FOR THE USE OF DECONTAMINATED RIVER SEDIMENTS IN ROAD CONSTRUCTION Progress Meeting November 26 th 2014 Prof. Ing. Massimo.
Quality Control Testing
Concrete Mix Design Technician School
Module 2-5 Field Sampling and Testing.  Identify reasons for conducting field sampling and lab testing  Describe typical field sampling and testing.
Construction Methods Lecture 9 Compacting Lecture 9.
CHAPTER TWO SOIL COMPRESSION.
SHALLOW SURFACE COMPACTION
Field Compaction Equipment and Procedures
Nondestructive Testing and Data Analysis Module 2-3.
Compaction and Stabilization Equipment
Developing a Mixture-Based Specification for Flexible Base.
Field Compaction Equipment and Procedures
Highway Materials Objective Describe briefly some of the physical characteristics and quality control tests for soils, aggregates, and bituminous materials.
1 Kh Training April Gudiance on the selection of Kh Soil Soil to Rock Rock Soil Soil to Rock Rock.
Sampling and Testing Concrete Mixes MATERIAL TESTING LABORATORY
Soil Compaction Topic I Topic I.
THE NATURE OF SOIL By Sarik Salim. The nature of Soil Soil is defined as a collection of mineral particles that was formed due to the weathering process.
Soil and Rock Soil and rock are the principle components of many construction projects. Knowledge of their properties, characteristics, and behavior is.
MODULE-3 Compaction.
Civil Engineering Department College of Engineering Course: Soil and Rock Mechanics (CE 260) Lecturer: Dr. Frederick Owusu-Nimo.
Copyright February 22, Index Properties of Soils Prof. Basuony El-Garhy Geotechnical Engineering and Foundations Civil Engineering Department Faculty.
INNOVATIVE INTEGRATED METHODOLOGY FOR THE USE OF DECONTAMINATED RIVER SEDIMENTS IN ROAD CONSTRUCTION Progress Meeting Pisa, February 25 th 2016 “CLEANSED.
Project Materials Usage and Concerns. Project Materials and Acceptance QC/QA Specifications QC/QA Specifications Quality Control Plans Quality Control.
Construction Inspection for FO Activities - Soils and Earthwork
Ahmedabad Institute of Technology
Marshall & Superpave Mix Design
SOIL CHARACTERISTIC II
SOIL COMPACTION GEOLOGY AND APPLIDE GEOLOGY -:Prepared By:- GEC,GODHRA
8. SOIL COMPACTION.
COMPACTION BY EQUIPMENTS
Compaction According ASTM D 1557/02
Compaction & Consolidation
Update on the current APT Project in Texas
Structural Design of Highway
Structural Design of Highway
Geotechnics 1 (BFC 21702) SOIL COMPACTION.
Pavement materials: Soil
SOILS PRESENTATION ACPA PIPE CLASS By: Colin A. Franco, P.E.
Presentation transcript:

Non-Nuclear Methods for Compaction Control of Unbound Materials Nayyar Siddiki, M.S., P.E. Geotech Construction & Tech. Support Engineer Office of Geotechnical Services, INDOT September 22, 2015

JTRP & In-house Research 1998, JTRP Technical Report Series Cone Penetration Test to Assess the Mechanical Properties of Subgrade Soils 2010, FHWA/IN/JTRP-2010/27 SPR Use of Dynamic Cone Penetration And Clegg Hammer Tests For Quality Control of Roadway Compaction and Construction 2014, FHWA/IN/JTRP SPR-3537 QA/QC of Subgrade and Embankment Construction In-House Research Research and Technical Papers

Clegg Hammer (hammer weight, 10kg). Moisture ProbeMicrowave OvenMoisture Analyzer Dynamic Cone Penetrometer Light Weight Deflectometer Equipments Evaluated

 Measure fundamental properties of material (strength, modulus, etc)  Delineate the poor to good compaction in short time  Simple enough to train and easy to perform with no electronics  Precise enough to accept with confidence  Safety issues (management of nuclear gauges) Motivation Behind The Change

Dynamic Cone Penetrometer DCP

An Un-Assembled DCP Handle Hammer Upper Road 22.6 in. Anvi l Connect Pin Drive Road 30 in. extension Tip 8 kg Variable Rod Drive Road

Soil type An Un-Assembled DCP Correlations R2R2 Penetration depth (inches) Range of applicability Coarse- grained soils Natural Blow Count= 0.17 x OMC x OMC to-128<OMC%<13 Manufactured Blow Count= 4.03 x ln (C u ) to-123.0<C u <6.0 Fine-grained soils Blow Count= x e -23 x PI x e x PI to-6 8 > PI% Blow Count= x e x PI x e x PI to-12 Based on the last research( QA/QC of Subgrade and Embankment Construction) following relationship have been developed and used DCP Correlation

Soil will be defined as cohesive material with more than 35 % passing the No. 200 sieve. Soils are further defined as follows: Clay Soil- Soil with a maximum dry density of 114 lb/ft 3 or less More than 1800 test performed in the laboratory, 3 types of soil identified on the basis of Maximum Dry Density and other parameters Cohesive Soil Soil Types

Granular Soil Granular soil will be defined as soil that is non- cohesive with 35 % or less passing the No. 200 sieve Sandy Soil- Soil with a maximum dry density greater than 120 lb/ft 3 Silty Soil- Soil with a maximum dry density greater than 114 lb/ft 3 and less than or equal to 120 lb/ft 3 Cont’d.

Test Pad Construction  Sieve Analysis………………AASHTO T-88, T-89/or ASTM D-1140  Atterberg Limits ………… AASHTO T-90  Moisture –Density ……… AASHTO T-99  Loss on Ignition……………AASHTO T-267  Ca/Mg Carbonate………… ITM-507*  Sulfate test ITM 510 *Not required unless shells or density <105 lbs. A representative soils sample of (25 lbs) is required from project limit or borrow pit for the above testing. The following laboratory tests are required during construction: Dynamic Cone Penetrometer (DCP)

Sieve Analysis Data with LL & PL DCP Target Information SIEVE ANALYSIS w/ LL & PI in accordance with ASTM D1140 and AASHTO T 89 & T 90 Sample ID# Contract No. Test Performed by: RG District STRUCTURAL BACKFILLY OR N Date HYGROSCOPIC MOISTURE % Corrected Sample WeightSieve Size Retained%passing Total Weight Of Sample (gms.) (#40) 425 um #VALUE! (Weights recorded retained per sieve) Percentages(#200) 75 um #VALUE! Sieve Size Weight Ret. (gms) RetainedPassing 1 1/2" 37.5 mm 1" 25.0 mm 3/4" 19.0 mm 1/2" 12.5 mmHYGROSCOPIC MOISTURE 3/8" 9.5 mm TARE WT. = # mm INITIAL WT. = # mm FINAL WT. = #40 425um MOISTURE = #200 75um 0.00 Gravel Sand►►►► % Coarse Sand Silt,Clay&Coll. % Fine Sand AASHTO Classification = %Passing # AASHTO Group Index = LL =PL =PI = LL and PI Blow Counts Liquid Limit PL44.0 Wet Soil/Tare Dry Soil/Tare Plasticity Index Moisture Loss 21.0 TareTested By: Dry Soil xx % Moisture

Sieve Analysis Data with LL & PL SIEVE ANALYSIS w/ LL & PI in accordance with ASTM D1140 and AASHTO T 89 & T 90 Sample ID#XXXX Contract No.XXXX Test Performed by: RG DistrictXXXX STRUCTURAL BACKFILL N Y OR N Date HYGROSCOPIC MOISTURE % 1.3 Corrected Sample Weight Sieve Size Retained%passing Total Weight Of Sample (gms.) (#40) 425 um #VALUE! (Weights recorded retained per sieve) Percentages(#200) 75 um #VALUE! Sieve Size Weight Ret. (gms) RetainedPassing 1 1/2" 37.5 mm " 25.0 mm /4" 19.0 mm /2" 12.5 mm HYGROSCOPIC MOISTURE 3/8" 9.5 mm # mm 0.0 INITIAL WT. =111.4 # mm 0.0 FINAL WT. =110.0 #40 425um MOISTURE =1.3 #200 75um Gravel0.0 Sand3.2 ►►►► 0.3% Coarse Sand Silt,Clay&Coll % Fine Sand AASHTO Classification = %Passing # AASHTO Group Index = LL =PL =PI = LL and PI Blow Counts Liquid Limit PL44.0 Wet Soil/Tare Dry Soil/Tare Plasticity Index Moisture Loss 21.0 TareTested By: Dry Soil xx % Moisture

Sieve Analysis Data with LL & PL SIEVE ANALYSIS w/ LL & PI in accordance with ASTM D1140 and AASHTO T 89 & T 90 Sample ID#XXXX Contract No.XXXX Test Performed by: RG DistrictXXXX STRUCTURAL BACKFILLNY OR N Date HYGROSCOPIC MOISTURE % 1.3 Corrected Sample Weight Sieve Size Retained%passing Total Weight Of Sample (gms.) (#40) 425 um #VALUE! (Weights recorded retained per sieve) Percentages(#200) 75 um #VALUE! Sieve Size Weight Ret. (gms) RetainedPassing 1 1/2" 37.5 mm " 25.0 mm /4" 19.0 mm /2" 12.5 mm HYGROSCOPIC MOISTURE 3/8" 9.5 mm TARE WT. =61.4 # mm 0.0 INITIAL WT. =111.4 # mm 0.0 FINAL WT. =110.0 #40 425um MOISTURE =1.3 #200 75um Gravel0.0 Sand3.2 ►►►► 0.3% Coarse Sand Silt,Clay&Coll % Fine Sand AASHTO Classification = A-7-6 %Passing # AASHTO Group Index =( 23 ) LL =44.0PL =23.0PI =21 LL and PI Blow Counts Liquid Limit PL Wet Soil/Tare Dry Soil/Tare Plasticity Index Moisture Loss Tare Tested By: Dry Soil xx % Moisture

INDOT FIELD DCP TARGET BLOW COUNTS CONTRACT #XXXXDATE: SAMPLE ID #XXXXDISTRICT: SIEVE ANALYSIS % PASSING 1 1/2" = AASHTO SOIL CLASSIFICATION = % PASSING 1" = % PASSING 3/4" = % PASSING 1/2" = % PASSING 3/8" = % PASSING #4 = % PASSING #8 = % PASSING #10 = % PASSING #30 = % PASSING #40 = % PASSING #200 = BLOW COUNT TARGET BLOW COUNT TARGET 95% C0MPACTION BLOW COUNT TARGET 100% COMPACTION LL = PL = SOIL TYPE PI = ↓ ↓↓↓ (N DCP)REQ|0-12 " CU = #DIV/0! (N DCP)REQ|0-12" NOT SUITABLE FOR MSE WALLS (N DCP)REQ|0-6 " Proctor MATERIALIS NOTEQUIVALENT TO #4 STRUCTURAL BACKFILL MAX WET (pcf) MAY BE * = Additional #8 and #30 Sieve Information is Required MAX DRY (pcf)SULFATE (ppm) = OPTIMUM MOISTURE % ORGANIC % =1MARL%= COLOR= LLR = pH = SUITABLE FOR CHEMICAL MODIFICATION MATERIALEQUIVALENT TOANYSTRUCTURAL BACKFILL IS NOT COMMENTS: Common Ex DCP FIELD TARGET REV Field DCP Target blow Counts

INDOT FIELD DCP TARGET BLOW COUNTS CONTRACT #XXXXDATE: SAMPLE ID #XXXXDISTRICT: SIEVE ANALYSIS % PASSING 1 1/2" = AASHTO SOIL CLASSIFICATION = % PASSING 1" = % PASSING 3/4" = % PASSING 1/2" = % PASSING 3/8" = % PASSING #4 = % PASSING #8 = % PASSING #10 = % PASSING #30 = 70.0 % PASSING #40 = 99.7 % PASSING #200 = 96.8 BLOW COUNT TARGET BLOW COUNT TARGET 95% C0MPACTION BLOW COUNT TARGET 100% COMPACTION LL = 44 PL = 23 SOIL TYPE PI = 21 ↓ ↓↓↓ (N DCP)REQ|0-12 " CU = #DIV/0! (N DCP)REQ|0-12" NOT SUITABLE FOR MSE WALLS (N DCP)REQ|0-6 " Proctor MATERIALIS NOTEQUIVALENT TO #4 STRUCTURAL BACKFILL MAX WET (pcf) 125 MAY BE * = Additional #8 and #30 Sieve Information is Required MAX DRY (pcf) 103 SULFATE (ppm) = OPTIMUM MOISTURE % 21 ORGANIC % =MARL%= COLOR= LLR = pH = SUITABLE FOR CHEMICAL MODIFICATION MATERIALEQUIVALENT TOSTRUCTURAL BACKFILL IS NOT COMMENTS: Common Ex DCP FIELD TARGET REV Cont’d.

INDOT FIELD DCP TARGET BLOW COUNTS CONTRACT #XXXXDATE: SAMPLE ID #XXXXDISTRICT: SIEVE ANALYSIS % PASSING 1 1/2" = AASHTO SOIL CLASSIFICATION =A-7-6 % PASSING 1" = % PASSING 3/4" = % PASSING 1/2" = % PASSING 3/8" = % PASSING #4 = % PASSING #8 = % PASSING #10 = % PASSING #30 = 70.0 % PASSING #40 = 99.7 % PASSING #200 = 96.8 BLOW COUNT TARGET BLOW COUNT TARGET 95% C0MPACTION BLOW COUNT TARGET 100% COMPACTION LL = 44 PL = 23 SOIL TYPE PI = 21 ↓ ↓ ↓↓ (N DCP)REQ|0-12 " CU = #DIV/0! (N DCP)REQ|0-12" NOT SUITABLE FOR MSE WALLS (N DCP)REQ|0-6 " CLAY6 Proctor MATERIALIS NOTEQUIVALENT TO #4 STRUCTURAL BACKFILL MAX WET (pcf) 125 MAY BE * = Additional #8 and #30 Sieve Information is Required MAX DRY (pcf) 103 SULFATE (ppm) = OPTIMUM MOISTURE % 21 ORGANIC % =1MARL%= COLOR= LLR = pH = SUITABLE FOR CHEMICAL MODIFICATION MATERIALIS NOTEQUIVALENT TOANYSTRUCTURAL BACKFILL IS NOT COMMENTS: Common Ex DCP FIELD TARGET REV at optimum Cont’d.

Max. Dry Density-OMC VS Blow Counts

Soil TypeMoisture Compaction Range Clay (<105 lb/cu ft)-2 to + 2% of optimum moisture content Clay ( lb/cu ft)-2 to + 1% of optimum moisture content Silty and Sandy (>114 lb/cuft)-3% of optimum moisture content and optimum Granular5 to 8% Moisture Range for Compaction The moisture range for all soil types are as follows

Silty, Sandy & Granular Soils 6” 3 rd Lift 6” 1 st Lift Dynamic Cone Penetrometer Testing Dynamic Cone Penetrometer (DCP) Clayey Soils 6” 2 nd Lift 3 rd Lift 6” 1 st Lift 2 nd Lift 3 rd Lift 2 nd Lift

Field Test for DCP Blow Counts  One Point Proctor for Cohesive Soils……………ITM 512  Dynamic Cone Penetrometer……………………… ITM 509  Field Determination of Moisture Content of Soils.ITM 506 Dynamic Cone Penetrometer (DCP)

Frequency of Testing  Three random test locations in accordance with ITM 802 for each 2000 cyd of compacted soil.  Moisture test at every 4 hrs for clayey soils.  Moisture test once per day for other type of soils. Note: The moisture sample should represent the entire lift. Additional moisture test may be required if there is an obvious visual change in moisture

Microwave moisture: Microwave with 700 watts input power, G-2 balance, samples size 100 gm, and test duration 5 minutes Stove /or Hot plate: Stove, G-20 or G-2 balance, samples size 1000g/or 500g and test duration 25 minutes Moisture probe: Campbell moisture probe, Proctor mold, rammer, G -20 balance, sample size 3000g, and test duration 25 minutes Field Moisture Test ( ITM 506) Approved Moisture Test Methods

When the soil type changes: One Point Proctor shall be performed to identify the soil type and revised DCP blow counts in accordance with the ITM T

Motive behind performing One Point Proctor To determine the following properties at the project:  Optimum Moisture Content of the blended soils  Maximum Dry Density and the use of ITM 512 Charts  Density based soils classification  Adjusted Optimum Moisture and DCP blow counts One Point Proctor

Compacted Sample Compacted sample & Mold. Record the weight Weigh the mold with specimen

134 pcf 119 pcf +1% 127 pcf MC 12% 134 pcf Example-1 MDD=119 pcf OMC= 12% One Point Proctor ITM Data not to be used with Granular Soils. -Plot based on data acquired from July 1965 to January 1969 by Soils Department. -Moisture must be between -3% and +1% for a valid Maximum Wet Density -These charts are an alternative to the Family of Curves and may be used in accordance with ITM-512 -Revised 4/4/14 Field Criteria for DCP Blow Counts

140 pcf MC 14% Out of range +1% Example-2 One Point Proctor ITM – T -Charts to be used for Clay, Silty, or Sandy soils only. -Moisture must be between -3% and +1% for a valid Maximum Wet Density -These charts are an alternative to the Family of Curves and may be used in accordance with ITM-512 -Revised 4/4/14 Field Criteria for DCP Blow Counts

Dynamic Cone Penetrometer (DCP) Field Criteria for DCP Blow Counts 140 pcf MC 14% Out of range +1% Example-2 One Point Proctor ITM Charts to be used for Clay, Silty, or Sandy soils only. -Moisture must be between -3% and +1% for a valid Maximum Wet Density -These charts are an alternative to the Family of Curves and may be used in accordance with ITM-512 -Revised 4/4/14

6 inches N Value N=1 N=2 N=6 N=4 N=9 N=10 N=15 N=14 N=10 DCP As A Diagnostic Tool

The average DCP blow count will not be less than 17 for the top 6 in. of a 14 in. lift. The average DCP blow count will not be less than 16 for the bottom 8 in. of a 14 in. lift. The average DCP blow count will not be less than 20 for an 8 in. lift.  Moisture Tests for chemically modified soils mixture will be performed at every 4 hours during chemical and soils mixing. Acceptance testing shall be performed with a DCP in accordance ITM 509. The chemically modified soil lift shall meet the following requirements for compaction: Chemically Modified Soil Compaction

Example for the DCP Test Top 6 in. of 14 in. lift 2 lane 1,500 feet DCP Test DCP blow counts: 15 (minimum), 18 and 18 each per 6 in. Average blow counts: ( ) ÷ 3 = 17 blows per 6 in. of 14 in. lift  Bottom 8 in. of 14 in. lift DCP blow counts: 14 (minimum), 18 and 16 each per 8 in. Average blow counts: ( ) ÷ 3 = 16 blows per 8 in. of 14 in. lift.

Blow counts of 18 and above will be used to determine the average for the 8 in. lift. Locations with test results less than the specified minimum blow counts will be retested and shall be reworked if the minimum blow count is not obtained. OR LWD may be used in Lieu of DCP. Cont’d.

DCP Use in Chemically Modified Soils 6 inches 8 inches 8 inches 14 inches 17 blows or more for the first 6 inches 16 blows or more for the next 8 inches 20 blows or more for the first 8 inches Chemically Modified Soils

Leveling Pad Foundation Requirement 6 inches 6 inches 6 inches 6 inches 6 inches 2.5 ft. deep N=5

The frequency of DCP measurements is: 1 DCP test for every 50 ft of linear MSE wall Or 5 DCP tests per end bent Unsuitable areas shall be removed, replaced, and compacted in accordance with 203 and ft. DCP DCP Test Frequency MSE Wall- 731 Rev.

Conclusions:  The DCP is portable, easy to operate, and requires no electronics. It takes only a couple of minutes to learn how to use the DCP  It is an effective tool to identify weak layers when penetration rates are plotted vs. depth.  DCPs can take deeper measurements  DCP readings are not affected by minor shrinkage cracks in soils  Improve inspector safety Dynamic Cone Penetrometer (DCP)

 Directly related to Design  Increase compaction uniformity  Increase productivity due to less time per test  DCP is a good indicator of strength and moisture conditions  Reduce the reliance on the Nuclear Gauge  Improve documentation and reporting Cont’d. Dynamic Cone Penetrometer (DCP)

LWD ITM 508 Control Box 3 ASTM E ZORN model ONLY

(1)Grip (2)Top fix and release mechanism (3)Guide road (4)10 Kg –falling weight (5)Lock pin (6)Set of steel springs (7)Loading plate diameter Three Major Elements: (a)Weight to induce the pulse (b)The loading plate (c)Accelerometer (To determine the deflection) Where q = applied stress, R = plate radius, μ = Poisson ratio, s = deflection Boussinesq Half Space Equation. LWD Setup

 Select site and set up LWD connection to its computational unit.  The test section should be level and smooth.  Set the plate on a prepared surface and seat it by turning it left and right 45 degrees. Do not drop the loading plate on the prepared surface.  LWD plate should not translate laterally with each successive drop. ITM 508, LWD Testing Procedure

 Perform 3 seating drops before collecting the data. If noticing excessive deflection.  Material needs additional compaction.  Following seating drops, perform three drops from a fixed height.  Record the average of 4th, 5th and 6th drops (If the change in deflection is 10 % or greater for any two consecutive drops, the material shall require additional compaction) Cont’d.

INDOT permit LWD testing on the following materials:  Aggregate No.53, No.73, structural backfill size 1,1.5 and 2 in  Chemically Modified soils Light Weight Deflectometer

Maximum Allowable Deflection 203-R-628 COMPACTION ACCEPTANCE WITH LWD (Adopted ) The maximum allowable deflection will be in accordance with the following: Material Type Maximum Allowable Deflection (mm) Lime Modified Soil0.30 Cement Modified Soil0.27 Aggregates over Lime Modified Soil0.30 Aggregates over Cement Modified Soil0.27 Materials not included in the table need a test pad.

Test Pad Construction Test section requirements: 1.AASHTO T-11, T-27, and T Subgrade shall be proof-rolled. 3.Test Pad area is 100 ft. by 20 ft. (part of the roadway). 4.One moisture test is based on AASHTO T-255. Moisture shall be between -3 and OMC. Perform moisture on aggregates before placing on grade.

Proof Rolling of Chemically Modified Subgrade A fully legally loaded tri-axle dump truck. ( About 70,000 lbs.)

100 ft X X X X X X X X X X ½ Width of Placement A Test Section Layout

TD409 LWDt Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD TEST SECTION FOR AGGREGATE OVER SOILS COPY TO:OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Section Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Test Section Position NumberAverage Subgrade LWD Info TypeLWD Assigned Test Number Avg.Test Deflection(S m )(mm)(Info) LWD Test Section Data PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) Test SiteMaximum Allowable Deflection (mm)T255 DATA Laboratory Report Data Material Name and Type Test Number Lab. SM ID (R+7 digits) Station Lab. SM ID (Last 5 digits) Tested on Material Passing (No. 4 or 3/4" Sieve) Optimum Moisture Content (OMC) (%) 1. Wt. of Pan & Wet Material (W1)(lb) or (g) Test Site Moisture Determined Moisture (%) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) Difference (Sp.Prov. -3% to OMC)03. Wt. of Moisture (lb) Line 1 - Line 20.0 Comments Comments 1 4. Wt. of Pan (W3)(lb) or (g) Comments 2 5. Wt. of Dry Material Line 2 - Line 40.0 % Moisture (0.1%) (Line 3 / Line 5) x 100 REMARKS: This procedure will continue until the difference of the average of the 10 LWD test between consecutive roller passes is equal to or less than 0.02 mm. V – VIBRATORY S - STATIC LWD SD Card# Compactor: LWD Serial Number RECORDED IN SITE-MANAGER: Qualified Technician: Cohesive or Granular (Fill or Cut) LWD Test Strip Data Sheet

TD409 LWDt Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD TEST SECTION FOR AGGREGATE OVER SOILS COPY TO:OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Section Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Test Section Position NumberAverage Subgrade LWD Info TypeLWD Assigned Test Number Avg.Test Deflection(S m )(mm)(Info) LWD Test Section Data PassesLWD Assigned Test Number4V+1S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) Test SiteMaximum Allowable Deflection (mm)T255 DATA Laboratory Report Data Material Name and Type Test Number Lab. SM ID (R+7 digits) Station Lab. SM ID (Last 5 digits) Tested on Material Passing (No. 4 or 3/4" Sieve) Optimum Moisture Content (OMC) (%) 1. Wt. of Pan & Wet Material (W1)(lb) or (g) Test Site Moisture Determined Moisture (%) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) Difference (Sp.Prov. -3% to OMC)03. Wt. of Moisture (lb) Line 1 - Line 20.0 Comments Comments 1 4. Wt. of Pan (W3)(lb) or (g) Comments 2 5. Wt. of Dry Material Line 2 - Line 40.0 % Moisture (0.1%) (Line 3 / Line 5) x 100 REMARKS: This procedure will continue until the difference of the average of the 10 LWD test between consecutive roller passes is equal to or less than 0.02 mm. V – VIBRATORY S - STATIC LWD SD Card# Compactor: LWD Serial Number RECORDED IN SITE-MANAGER: Qualified Technician: Cohesive or Granular (Fill or Cut) LWD Test Strip Data Sheet

TD409 LWDt Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD TEST SECTION FOR AGGREGATE OVER SOILS COPY TO:OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Section Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Test Section Position NumberAverage Subgrade LWD Info TypeLWD Assigned Test Number Avg.Test Deflection(S m )(mm)(Info) LWD Test Section Data PassesLWD Assigned Test Number4V+1S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number5V+2S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) Test SiteMaximum Allowable Deflection (mm)T255 DATA Laboratory Report Data Material Name and Type Test Number Lab. SM ID (R+7 digits) Station Lab. SM ID (Last 5 digits) Tested on Material Passing (No. 4 or 3/4" Sieve) Optimum Moisture Content (OMC) (%) 1. Wt. of Pan & Wet Material (W1)(lb) or (g) Test Site Moisture Determined Moisture (%) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) Difference (Sp.Prov. -3% to OMC)03. Wt. of Moisture (lb) Line 1 - Line 20.0 Comments Comments 1 4. Wt. of Pan (W3)(lb) or (g) Comments 2 5. Wt. of Dry Material Line 2 - Line 40.0 % Moisture (0.1%) (Line 3 / Line 5) x 100 REMARKS: This procedure will continue until the difference of the average of the 10 LWD test between consecutive roller passes is equal to or less than 0.02 mm. V – VIBRATORY S - STATIC LWD SD Card# Compactor: LWD Serial Number RECORDED IN SITE-MANAGER: Qualified Technician: Cohesive or Granular (Fill or Cut) LWD Test Strip Data Sheet

TD409 LWDt Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD TEST SECTION FOR AGGREGATE OVER SOILS COPY TO:OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Section Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Test Section Position NumberAverage Subgrade LWD Info TypeLWD Assigned Test Number Avg.Test Deflection(S m )(mm)(Info) LWD Test Section Data PassesLWD Assigned Test Number4V+1S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number5V+2S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number6V+3S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) Test SiteMaximum Allowable Deflection (mm)T255 DATA Laboratory Report Data Material Name and Type Test Number Lab. SM ID (R+7 digits) Station Lab. SM ID (Last 5 digits) Tested on Material Passing (No. 4 or 3/4" Sieve) Optimum Moisture Content (OMC) (%) 1. Wt. of Pan & Wet Material (W1)(lb) or (g) Test Site Moisture Determined Moisture (%) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) Difference (Sp.Prov. -3% to OMC)03. Wt. of Moisture (lb) Line 1 - Line 20.0 Comments Comments 1 4. Wt. of Pan (W3)(lb) or (g) Comments 2 5. Wt. of Dry Material Line 2 - Line 40.0 % Moisture (0.1%) (Line 3 / Line 5) x 100 REMARKS: This procedure will continue until the difference of the average of the 10 LWD test between consecutive roller passes is equal to or less than 0.02 mm. V – VIBRATORY S - STATIC LWD SD Card# Compactor: LWD Serial Number RECORDED IN SITE-MANAGER: Qualified Technician: Cohesive or Granular (Fill or Cut) LWD Test Strip Data Sheet

TD409 LWDt Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD TEST SECTION FOR AGGREGATE OVER SOILS COPY TO:OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Section Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Test Section Position NumberAverage Subgrade LWD Info TypeLWD Assigned Test Number Avg.Test Deflection(S m )(mm)(Info) LWD Test Section Data PassesLWD Assigned Test Number4V+1S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number5V+2S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number6V+3S Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) PassesLWD Assigned Test Number Avg.Test Deflection (S m ) (mm) Test Site Maximum Allowable Deflection (mm)0.267 T255 DATA Laboratory Report Data Material Name and Type Test Number111 Lab. SM ID (R+7 digits) Station Lab. SM ID (Last 5 digits) Tested on Material Passing (No. 4 or 3/4" Sieve) 3/4 Optimum Moisture Content (OMC) (%) 1. Wt. of Pan & Wet Material (W1)(lb) or (g) Test Site Moisture Determined Moisture (%) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) Difference (Sp.Prov. -3% to OMC)0 3. Wt. of Moisture (lb) Line 1 - Line Comments Comments 1 4. Wt. of Pan (W3)(lb) or (g) Comments 2 5. Wt. of Dry Material Line 2 - Line % Moisture (0.1%) (Line 3 / Line 5) x REMARKS: This procedure will continue until the difference of the average of the 10 LWD test between consecutive roller passes is equal to or less than 0.02 mm. V – VIBRATORY S - STATIC LWD SD Card# Compactor: LWD Serial Number RECORDED IN SITE-MANAGER: Qualified Technician: Cohesive or Granular (Fill or Cut)

TD409 LWD Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD AND MOISTURE ACCEPTANCE TESTS COPY TO:OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis AGGREGATES OVER CHEMICALLY MODIFIED SOILS CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Number of Passes with Compactor Comp. Agg. LWD Assigned Test Number Test Deflection (S m ) (mm) Average Deflection (mm) Maximum Allowable Deflection (mm) Laboratory Data Material Name and Type Lab. SM ID (R+12 digits) Optimum Moisture Content (OMC) (%) Test Site Moisture Determined Moisture (%) Difference (Sp.Prov.-3% to OMC)000 Comments Comments 1 Comments 2 PASS OR FAIL OR INFORMATION REQUIREMENTS: ITM 506 DATA Maximum Allowable Deflections Aggregates over Lime Modified Soil 0.30 (mm) Aggregates over Cement Modified Soil 0.27 (mm) Test Number Station Tested on Material Passing (No. 4 or 3/4" Sieve) REMARKS: 1. Wt. of Pan & Wet Material (W1)(lb) or (g) CS = Crushed Stone, G= Gravel, S= Slag 2. Wt. of Pan & Dry Material (W2)(lb) or (g) 3. Wt. of Moisture (lb) Line 1 - Line Wt. of Pan (W3)(lb) or (g) LWD SD Card# 5. Wt. of Dry Material Line 2 - Line 40.0 Compactor: % Moisture (0.1%) (Line 3 / Line 5) x 100 LWD Serial Number RECORDED IN SITE-MANAGER: Qualified Technician: LWD Accepting Data Sheet

Example TD409 LWD Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD AND MOISTURE ACCEPTANCE TESTS COPY TO: OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis FOR CHEMICALLY MODIFIED SOILS CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Number of Passes with Compactor 1 Chem. Modif. LWD Assigned Test Number Test Deflection (S m ) (mm) Average Deflection (mm) Target Maximum Allowable Deflection (mm)0.267 * From test section Maximum Allowable Deflection (mm) Laboratory Data Lab. SM ID (R+12 digits) Optimum Moisture Content (OMC) (%) Test Site Moisture Determined Moisture (%) Sec. OMC or above000 Comments Comments 1 Comments 2 PASS OR FAIL OR INFORMATION REQUIREMENTS: ITM 506 DATA Maximum Allowable Deflections Lime Modified Soil 0.30 (mm), Cement Modified Soil 0.27(mm) Test Number Station Tested on Material Passing (No. 4 or 3/4" Sieve) REMARKS: 1. Wt. of Pan & Wet Material (W1)(lb) or (g) * From test section (Determined by test section) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) 3. Wt. of Moisture (lb) Line 1 - Line Wt. of Pan (W3)(lb) or (g) LWD SD Card# 5. Wt. of Dry Material Line 2 - Line 40.0 Compactor: % Moisture (0.1%) (Line 3 / Line 5) x 100 Cont’d.

Example TD409 LWD Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD AND MOISTURE ACCEPTANCE TESTS COPY TO: OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis FOR CHEMICALLY MODIFIED SOILS CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Number of Passes with Compactor 12 Chem. Modif. LWD Assigned Test Number Test Deflection (S m ) (mm) Average Deflection (mm) Target Maximum Allowable Deflection (mm) * From test section Maximum Allowable Deflection (mm) Laboratory Data Lab. SM ID (R+12 digits) Optimum Moisture Content (OMC) (%) Test Site Moisture Determined Moisture (%) Sec. OMC or above000 Comments Comments 1 Comments 2 PASS OR FAIL OR INFORMATION REQUIREMENTS: ITM 506 DATA Maximum Allowable Deflections Lime Modified Soil 0.30 (mm), Cement Modified Soil 0.27(mm) Test Number Station Tested on Material Passing (No. 4 or 3/4" Sieve) REMARKS: 1. Wt. of Pan & Wet Material (W1)(lb) or (g) * From test section (Determined by test section) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) 3. Wt. of Moisture (lb) Line 1 - Line Wt. of Pan (W3)(lb) or (g) LWD SD Card# 5. Wt. of Dry Material Line 2 - Line 40.0 Compactor: % Moisture (0.1%) (Line 3 / Line 5) x 100 Cont’d.

Example TD409 LWD Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD AND MOISTURE ACCEPTANCE TESTS COPY TO: OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis FOR CHEMICALLY MODIFIED SOILS CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Number of Passes with Compactor 12 3 Chem. Modif. LWD Assigned Test Number Test Deflection (S m ) (mm) Average Deflection (mm) Target Maximum Allowable Deflection (mm)0.267 * From test section Maximum Allowable Deflection (mm) Laboratory Data Lab. SM ID (R+12 digits) Optimum Moisture Content (OMC) (%) Test Site Moisture Determined Moisture (%) Sec. OMC or above000 Comments Comments 1 Comments 2 PASS OR FAIL OR INFORMATION REQUIREMENTS: ITM 506 DATA Maximum Allowable Deflections Lime Modified Soil 0.30 (mm), Cement Modified Soil 0.27(mm) Test Number Station Tested on Material Passing (No. 4 or 3/4" Sieve) REMARKS: 1. Wt. of Pan & Wet Material (W1)(lb) or (g) * From test section (Determined by test section) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) 3. Wt. of Moisture (lb) Line 1 - Line Wt. of Pan (W3)(lb) or (g) LWD SD Card# 5. Wt. of Dry Material Line 2 - Line 40.0 Compactor: % Moisture (0.1%) (Line 3 / Line 5) x 100 Cont’d.

Example TD409 LWD Rev 12 INDIANA DEPARTMENT OF TRANSPORTATION ORIGINAL:PROJECT FILE 6/10/2014 LWD AND MOISTURE ACCEPTANCE TESTS COPY TO: OFFICE OF GEOTECHNICAL ENGINEERING, Indianapolis FOR CHEMICALLY MODIFIED SOILS CONTRACT NO. PROJECT NO. ROAD NO. DATE WEATHER FIELD TEST NO. SITEMANAGER TEST NO. SITEMANAGER SAMPLE I.D NO. (R+12 digits) Test Site Data Station Line No. Ref. To Centerline Elevation or Lift No. Compacted Depth of Lift (inches) Number of Passes with Compactor 12 3 Chem. Modif. LWD Assigned Test Number Test Deflection (S m ) (mm) Average Deflection (mm) Target Maximum Allowable Deflection (mm) * From test section Maximum Allowable Deflection (mm) Laboratory Data Lab. SM ID (R+12 digits) Optimum Moisture Content (OMC) (%) Test Site Moisture Determined Moisture (%) Sec. OMC or above000 Comments Comments 1 Comments 2 PASS OR FAIL OR INFORMATION REQUIREMENTS: ITM 506 DATA Maximum Allowable Deflections Lime Modified Soil 0.30 (mm), Cement Modified Soil 0.27(mm) Test Number Station Tested on Material Passing (No. 4 or 3/4" Sieve) REMARKS: 1. Wt. of Pan & Wet Material (W1)(lb) or (g) * From test section (Determined by test section) 2. Wt. of Pan & Dry Material (W2)(lb) or (g) 3. Wt. of Moisture (lb) Line 1 - Line Wt. of Pan (W3)(lb) or (g) LWD SD Card# 5. Wt. of Dry Material Line 2 - Line 40.0 Compactor: % Moisture (0.1%) (Line 3 / Line 5) x 100 Cont’d.

Chemically modified soils …Three test per 1400 cyd for two lane road. Chemically modified soils shall be ……………………proofrolled Aggregates over chemically modified soils ………Three Test for 800 tons Moisture Test ………………………….One Moisture Test /day LWD Acceptance Testing

 The aggregates larger than 1.5 in. shall not be over 15% in testing location.  The testing location shall not exceed 5% inclination.  The testing location shall not be frozen.  Test shall not be executed when deflection measurements are less than 0.2 mm.  LWD test is questionable in case of shallow ground water (2 feet) or soil with high moisture content. Limitations

 Quick and easy.  Inspector remains on grade at the test site.  Roller operator see the results. Contactor more aware of final test results.  Better understanding of water content.  Easily transfer the data electronically.  Modulus relates reliably with design parameters such as CBR, shear strength and Resilient Modulus.  Test takes about three minutes. Conclusions

Modulus-Based Construction Specification for Compaction of Earthwork and Unbound Aggregate: Appendices DRAFT FINAL REPORT Prepared for National Cooperative Highway Research Program NCHRP Project Transportation Research Board of The National Academies Submitted by: The University of Texas at El Paso Center for Transportation Infrastructure Systems 500 West University Avenue El Paso, TX August 2014 TRANSPORTATION RESEARCH BOARD NAS- NRC PRIVILEGED DOCUMENT This interim report, not released for publication, is furnished only for review to members of or participants in the work of the National Cooperative Highway Research Program (NCHRP). It is to be regarded as fully privileged, and dissemination of the information included herein must be approved by the NCHRP NCHRP Project 10-84

US-50 Selected Test Section in North Vernon

Evaluation of Modulus Based Devices Subgrade Layer: LWD modulus psi. DCP modulus psi for the top 6-in. layer DCP modulus psi for the 12 in. penetration ( Composite modulus of the layer) Subbase Layer: LWD modulus – psi The standard deviation of the LWD replicate tests was 500 psi Subgrade Design Modulus 6500 psi

Device Estimated Tests Per 8-hr Day Daily Employee Rate Daily Equipment Rate Daily Charge Cost Per Test (Approx.) Est. Device Price NDG including 1-Point Proctor 18$336.00$35.00$371.00$20.60$ 8, $12, DCP32$336.00$ 3.00$339.00$10.00$ 1, $ 1, LWD72$336.00$14.00$350.00$ 5.00$ 10, $ 1, Cost Comparison Among NDG, DCP, and LWD Other Costs: NDG - Training: Safety and Maintenance DCP - None LWD- Calibration and Verification

INDOT Compaction Requirements

ITM No T Field Determination of Moisture Content of Soil ITM No T Field Determination of Deflection Using Light Weight Deflectometer ITM No T Field Determination of Strength Using Dynamic Cone Penetrometer ITM No T Field Determination of Maximum Dry Density and Optimum Moisture Content of Soil (AASHTO T272) ITM No T Determination of the Quality of the Soil Plant Growth Layer

LWD Field Testing Procedures intranet.indot.state.in.us/materialtests/pdfs/LWDFieldTestingProcedures.pdf Link for: ITM No T Verifying Soil Test Molds ITM No T Verifying Soil Compaction Rammers

Tel: ext (Cell) Contact information: Nayyar Siddiki