EET286 – Fall 2015 follow-up Four types of clinical equipment

Slides:



Advertisements
Similar presentations
Functions of the Respiratory system
Advertisements

Respiration Respiration is the act or process of breathing.
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Principles of Pressure Transducers James Peerless January 2012.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
Alex Bode Emmanuel Cordova Mikel Dualos Christa Hamilton Medical Instrumentation Spring 2011.
CIRCULATORY AND RESPIRATORY SYSTEMS Homeostasis- maintaining constant internal conditions under changing environmental conditions Organ systems that supply.
Lung Capacity. Tidal Volume  TV: The amount of air going into or out of the lungs on single breath.
South Taiwan University Institute of Mechanical Engineering How to Read SpO 2 and yoga breath’s Reference Prof. :Yi-Chu Hsu Name :Ruei-Cheng Liu Student.
14-May-15Najwa subuh- MSN in Pediatric1. 14-May-15Najwa subuh- MSN in Pediatric2 A pulse-oximeter is a device that measures the amount of saturated hemoglobin.
Respiratory Volumes Used to assess a person’s respiratory status
Cutnell/Johnson Physics 8th edition
Pulmonary Function During Exercise Chapter 10. The Respiratory System Provides gas exchange between the environment and the body Regulates of acid-base.
Objectives Discuss the principles of monitoring the respiratory system
RESPIRATION Dr. Zainab H.H Dept. of Physiology Lec.5,6.
Principles of Biology By Frank H. Osborne, Ph. D. Lab 7 - Respiration and Circulation.
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
POWER SUPPILES LECTURE 20.
The mechanics of breathing and Respiratory Volumes
Cardiovascular System Assessments
Problems of creating physiologically matched artificial cardiac pacemakers Sergei Ovsjanski Tallinn University of Technology 2009.
Pacemaker & its Classification
Single Chamber Temporary Pacing Operations & Troubleshooting.
Respiratory Fitness Ashlea Lockett, Nicky Gilchrist & Jenna Cruickshank.
Ventilators All you need to know is….
Dr Chaitanya Vemuri Int.Med M.D Trainee.  The choice of ventilator settings – guided by clearly defined therapeutic end points.  In most of cases :
Blood pressure monitoring Monica Morosan. AAGBI standards of monitoring A - Induction and Maintenance of Anaesthesia 1. Pulse oximeter 2. Non invasive.
Arterial blood pressure is a measure of the pressure exerted by the blood as it flows through the arteries. The systolic pressure is the pressure of the.
Cardiovascular System
Lecture 8 Electrical energy EMF Resistors in series and parallel
Without reference, identify principles about volume/pressure and high frequency ventilators with at least 70 percent accuracy.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Chapter 16.  Ventilation includes:  Inspiration (inhalation)  Expiration (exhalation)
DEVICES TO PROTECT AGAINST ELECTRICAL HAZARDS
1 Pulmonary Function Tests J.B. Handler, M.D. Physician Assistant Program University of New England.
Pulmonary Function Testing (PFT)
Mechanical Ventilation EMS Professions Temple College.
Pulmonary Function Measurements
ELECTRICAL SAFETY OUTLINE  The basic effect of electricity on human body  Ventricular Fibrillation  Electric shock  Electric Shock – Treatment  Important.
BASICS OF WAVEFORM INTERPRETATION Michael Haines, MPH, RRT-NPS, AE-C
Carbon Dioxide Monitoring
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
Capnography: Current and Future Use by EMS Presented by: Tim Ludwig EMT-P.
Pulmonary Function Tests (PFTs)
Grounding.
Pulmonary Function Studies: Review By Elizabeth Kelley Buzbee AAS, RRT- NPS, RCP Lone Star college Systems- Kingwood.
Chapter 24 Vital Signs.
Copyright © 2009 Pearson Education, Inc. Figure 10.9 The respiratory cycle.
RESPIRATION PRACTICALS
Forces acting on blood during circulation
Hemodynamic Monitoring John Nation RN, MSN Thanks to Nancy Jenkins.
1- Total lung capacity: = tidal volume + inspriatory reserve volume + expiratory reserve volume + residual volume ( 6 liters) 2- Normal Capacity (Functional.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Monitoring in Anesthesia Dr.Arkan Jaafar, M.D. Anesthesiologist,Medical college of Mosul.
The Spirometry 1 Dr Mazen Qusaibaty MD, DIS / Head Pulmonary and Internist Department Ibnalnafisse Hospital Ministry of Syrian health –
the Most Beneficent, the Most Merciful
Noninvasive Blood Pressure Measurement © D. J. McMahon 2014 rev
Capnography: Defined and Clinical Applications
Lung Function Test Physiology Lab-3 March, 2017.
Grounding.
ELECTRICAL SAFETY FOR MEDICAL EQUIPMENT By m.naga sundhari
Lung Capacity.
Maintenance schedule for different equipment and their records in a hospital By Mr. Rahul kumar.
טלמדיסין העברת נתוני חולה (מספריים ווידיאו) בזמן העברה בין בתי חולים.
Physiology of the Respiratory System
CARDIAC DEFIBRILLATORS
CARDIAC DEFIBRILLATORS
PHARMACOTHERAPY - I PHCY 310
Presentation transcript:

EET286 – Fall 2015 follow-up 2015-12-10 Four types of clinical equipment Power Connectors NFPA99 Chassis Leakage (touch) Current Human Heart & Cardiac Cycle Wiggers diagram Pressure Conversions Common Electronic Component Abbreviations Quiz #2 recap Quiz #3 recap

Four types of clinical equipment Monitoring: Detects and displays physiologic data for the purposes of clinical observation. Diagnostic: Detects, displays, and records physiologic data in order to confirm or rule out a disorder or disease. Therapeutic: Applies treatment in the form of energy or medication in order to treat a disorder or disease. Assistive: Used as an accessory to facilitate a medical or surgical procedure.

Power Connectors plug: male connector, furthest away from power source outlet or receptacle: female connector providing power NEMA: (U.S.) National Electrical Manufacturers Association IEC: International Electrotechnical Commission NEMA wire colors: Hot – Black Neutral – White Ground – Green IEC wire colors: Hot – Brown Neutral – Blue Ground Green/Yellow Screw colors on some connectors: Hot – Gold Neutral – Silver Ground – Green HOT (L1) Neutral (L2) Ground (earth) NEMA colors: Black White Green IEC colors: Brown Blue Green/Yellow connectors: Gold Silver Green

NFPA99 Chassis Leakage (touch) Current 1999 edition 2005 edition 2012 edition 2015 edition 10.2.6* Touch Current – Portable Equipment. The touch current for cord- connected equipment shall not exceed 500 uA with normal polarity and the ground wire disconnected (if a ground wire is provided).

Pressure Conversions Most useful conversions in bold 51.7 1.36 14.7 PSI KiloPascal cm of H2O mm of Hg atmosphere millibar 1 PSI = 1 6.89 70.3 51.7 0.068 68.9 1 KiloPascal = 0.145 10.19 7.5 0.0098 10 1 cm of H2O = 0.014 0.1 0.735 0.00097 1 mm of Hg = 0.019 0.133 1.36 0.0013 1.33 1 atmosphere = 14.7 101 1033 760 1013 1 millibar = 0.0147 1.02 0.75 0.0009 Most useful conversions in bold

Manometers, two styles; Pressure measured as a column of mercury: closed end (contains vacuum) measures atmospheric pressure 760 mmHg ‘normal’ higher atmospheric pressure = higher number (pressure in outer space vacuum would be 0 mmHg) open end (contains ambient air pressure) measures applied pressure 0 mmHg is ‘unpressurized’ state higher applied pressure = higher number

Common Electronic Component Abbreviations (rev 2015-12-01) (silk screened on circuit boards and printed on schematics) technical term is "reference designators" B battery BR bridge rectifier BT battery C capacitor CB circuit breaker CR diode CT center tap of transformer D diode F fuse IC integrated circuit (chip) J jack or jumper K relay L coil or inductor LED light emitting diode M motor Q transistor R resistor S switch SW switch T terminal T transformer TP test point U integrated circuit (chip) VR voltage regulator XTAL crystal

ECG trace and display Calibration (y axis): 10 mm = 1 mV Speed (x axis): 25mm = 1 Second |---- 10 mm (1 milliVolt) -----------| |---- 25 mm (1 Second) ----------------------------------------------------------------------------------|

Pacemaker Modes: Asynchronous: provides pulses at a fixed rate Demand (or ‘Synchronous’): provides pulses when the heart fails to beat Rate-Modulated: provides pulses based on the heart’s current activity

Defibs for Cardioversion The use of a small energy pulse from a defibrillator to convert an non-lethal arrhythmia (eg atrial flutter) to a normal sinus rhythm Delivers a pulse about 30ms after the peak of the R-wave, synchronized by the defibrillator Modern units can discriminate the R-wave from the T-wave or noise spikes

Timing of cardioversion pulse Do NOT cardiovert across the T-wave !

Linear power supply (2) (3) (4) (5) Line in (not shown here) Transform (only the output is shown here) Rectify (usually a 4-diode bridge) Filter (usually a big cap & a small cap) Regulate (often with 78xx & 79xx ICs on heat sinks) Linear power supply (2) (3) (4) (5)

from Electrical Safety presentation (class 6) CORRECTED: (per NFPA-99, 2012 edition) Resistance of Ground wire of power cord: 500 milliOhms (500mΩ or .5Ω) Leakage current at the chassis: NC (normal condition) 100 microAmps (100 μA) SFC (Single Fault Condition, e.g. open ground) 500 microAmps (500 μA) Leakage current for any one patient contact lead to ground: 10 μA with ground closed, 50 μA with ground open. Leakage current for each patient contact lead to any other lead: Leakage current for patient leads exposed to line voltage: 50 μA

Leakage current is both capacitive, caused by intrinsic or “distributed capacitance” Leakage current is both capacitive, caused by intrinsic capacitance between conductors; and resistive, caused by imperfect insulation.

Where does the leakage current go?

Open ground ! Where does the leakage current go now?

chassis leakage current: Test device measuring chassis leakage current:

as defined by the IEC standard 60601-1: “Applied Part” of medical equipment as defined by the IEC standard 60601-1: Type B: Applied parts that are generally not conductive and can be immediately released from the patient. May be grounded. eg: Non-invasive BP monitors [think: Body] Type BF: Devices that have direct contact with the patient, or parts that have long term contact with the patient. eg: ECG monitors [think: Body, Floating (ground)] Type CF: Applied parts that have direct contact with the heart. eg: Invasive pressure monitors, defib paddles [think: Cardiac Floating (ground)]

ONE of these ratings should be present on a medical device If ‘Defib Proof’, ONE of these

Troubleshooting invasive BP lines: Almost ideal Air bubbles in the line Line is partially occluded

Damping in any oscillating system: Damping is an effect on any oscillating system that reduces or restricts its oscillations. In a mechanical system, damping is produced by drag in the system. In a fluid system, damping is caused by viscosity. In an electronic system, damping is caused by impedance. Undamped: The system oscillates at its natural resonant frequency. Critically damped: When disturbed, the system returns to equilibrium quickly, without oscillation. Overdamped: When disturbed, the system returns to equilibrium without oscillating. Underdamped: When disturbed, the system oscillates, but the amplitude decreases to zero.

Swan-Ganz catheter (in ‘right’ heart) Starts here Ends up ‘wedged’ here or here

Swan-Ganz Catheter – From the Right Atrium through the Right Ventricle, into the Pulmonary Artery

Pressure waveforms during insertion of the Swan-Ganz catheter:

Most used:

Manual determination of NIBP blood pressure :

NIBP Blood pressure determination by oscillometry i.e. the automated electronic method:

Pressure pulsations during oscillometry:

non-invasive blood pressure monitor

Quiz #3 recap R L #1: Intra-aortic balloon pump (IABP) is inserted into descending AORTA (output of LEFT heart) #3: IABP is typically used for 1-2 days #6: Capnography is measurement of CO2. Measured by how much IR (infrared) light is absorbed by the gas sample. R L (from body) (TO body) (to lung) (to lung) (from lung) (from lung) (from body)

Question #7: Deep breath (or sigh) normal breathing exhaling as much as you can this much air always stays in your lungs note: TLC is often shown as 6 liters, which is normal for a 75 kg (165 #) person. 80 ml per kg of body weight (as shown here) is more accurate.

Pressure-Volume-Flow (X axis for these is time) Question #14: Flow-Volume Loop (time is shown as a counter-clockwise loop): Pressure-Volume-Flow Diagrams (X axis for these is time) exhale note: Residual Volume is shown on the right side (still part of Total Lung Capacity – 6 liters) inhale PEFR: Peak Expiratory Flow Rate: measures how fast a person can exhale (breathe out). PIFR: Peak Inspiratory Flow Rate FVC: Functional Vital Capacity (same as VC)

Respiratory Gasses Blood Components Inspired (inhaled) air: N2 79% O2 21% Expired (exhaled) air: N2 79% O2 16% CO2 5% Blood Components Hemoglobin (hb without attached O2) Oxyhemoglobin (hb with attached O2) Carboxyhemoglobin (hb with attached CO, Carbon Monoxide) gives inaccurate SpO2 Methemoglobin (pron: MET-hemoglobin) cannot bind to O2 and gives inaccurate SpO2 this ratio gives SpO2 in Pulse Oximetry