Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.

Slides:



Advertisements
Similar presentations
X-ray Photoelectron Spectroscopy
Advertisements

Mass Spectrometry Chem 3500 Mass Spectrometry Y. Zhao Lecture 2 A Glimpse of Mass Spectrometry Began from 1920s: Aston, Dempster, Thompson MS is often.
Performance of a Hybrid RF/DC Quadrupole-Linear Ion Trap Mass Spectrometer James W. Hager MDS SCIEX ASMS, 2002.
Focused ion beam (FIB) 1.Overview. 2.Ion source and optics. 3.Ion-solid interaction, damage. 4.Scanning ion beam imaging. ECE 730: Fabrication in the nanoscale:
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
AMCF Materials Characterization School 2012 X-Ray Photoelectron Spectroscopy Tim Morgan.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
12-1 Molecular Mass Spectroscopy Molecular structure Composition of mixtures Molecular mass spectra Ion Source Mass Spectrometers Applications.
First of all, do you know any methods to check chemical composition? Or how you know what is what? First of all, do you know any methods to check chemical.
Mass Spectrometry Inlet system Ion Source Mass Analyzer Ion Detector.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Chem. 133 – 4/28 Lecture. Announcements Lab Report 2.3 due Today Pass back graded materials (lab reports 2.2, Q5, and AP3.1) Today’s Lecture Mass Spectrometry.
XPS and SIMS MSN 506 Notes.
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
Secondary Ion Mass Spectrometry Professor Paul K Chu.
Secondary Ion Mass Spectrometry Professor Paul K Chu.
Molecular Mass Spectroscopy Chem Introduction In Mass Spectroscopy (MS), atomic and molecular weights are generally expressed in terms of atomic.
Mass Spectrometry.
LC-MS Lecture 7.
Photoelectron Spectroscopy Lecture 7 – instrumental details –Photon sources –Experimental resolution and sensitivity –Electron kinetic energy and resolution.

Russell Rouseff FOS 6355 Summer 2005 What is Mass Spectroscopy Analytical Chemistry Technique Used to identify and quantify unknown compounds Can also.
S. Kugler: Lectures on Amorhous Semiconductors 1 Preparation.
An Introduction to SIMS and the MiniSIMS ToF © Millbrook Instruments Limited Blackburn, UK
Development of a TOF Version of the Desktop MiniSIMS Design & Applications A.J. Eccles, B. Cliff, C. Jones, N. Long, P. Vohralik Millbrook Instruments.
Secondary Ion Mass Spectrometry (SIMS)
ECE/ChE 4752: Microelectronics Processing Laboratory
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
Secondary ion mass spectrometry (SIMS)
Ion implanter – HV terminal 500 kV a number of Nielsen and RF ion sources for gaseous and solid materials mass analysis better than 1 a.m.u. beam current.
반도체 제작 공정 재료공정실험실 동아대학교 신소재공학과 손 광 석 隨處作主立處開眞
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
PARTICLE-INDUCED DESORPTION OF BENZOHYDROXAMIC ACID DERIVATIVES ADSORBED ON A COPPER SURFACE STUDIED BY LASER IONIZATION MASS SPECTROMETRY S.Wyczawska.
Mass spectrometry and the PITZ Sven Lederer Technisches Seminar
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Based on ionization of gas phase molecule followed by analysis of the masses of the ions produced. The Mass Spectrum: Graph of ion intensity versus mass-to-charge.
Chapter 20 # 4, 5, 12, 13, 16. Fig (p.551) Mass spectrum of ethyl benzene Fragment peaks Unit: amu or dalton Fragment peaks.
Quantification Techniques Under Dynamic SIMS 1 Secondary Ion Mass Spectrometer Start-Up Project Overview Secondary Ion Mass Spectrometry Overview MiniSIMS:
The Apparatus…. Ionic target studies…. Neutral target studies…. Queens University Belfast University College London.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Sputter deposition.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Ionization energy?. Ionization energy? EI Ionization??
X-ray absorption spectroscopy (XAS)
Updates of Iowa State University S. Dumpala, S. Broderick and K. Rajan Sep – 18, 2013.
Questions/Problems on SEM microcharacterization Explain why Field Emission Gun (FEG) SEM is preferred in SEM? How is a contrast generated in an SEM? What.
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
Hiden EPIC Quadrupole Mass Spectrometer for Scientific Applications.
Quadrupole Mass Spectrometry Concepts Mass Spectrometers for Residual Gas Analysis.
Section 5: Thin Film Deposition part 1 : sputtering and evaporation
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
Mass Spectrometry u Chapter 12 Chapter 12.
DC Sputtering Disadvantage #1 Low secondary electron yield
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Study of vacuum stability at cryogenic temperature
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Mass Spectrometry Obaid M. Shaikh.
Study of vacuum stability at cryogenic temperature
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
1.6 Magnetron Sputtering Perpendicular Electric Magnetic Fields.
1.6 Glow Discharges and Plasma
Nat. Rev. Nephrol. doi: /nrneph
Molecular Mass Spectroscopy
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Shukui Zhang, Matt Poelker, Marcy Stutzman
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Surface analysis techniques part I
Presentation transcript:

Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis

Secondary Ion Mass Spectrometry What are Secondary Ions? Ions created from the interaction between a surface and an ion beam (the primary ions) Require high vacuum (≤10 -6 torr) in order to minimize ion-ion interactions Analyzed using a mass spectrometer Studies are used to gather information about the surface being analyzed and can fall in to two categories o Dynamic SIMS – used for bulk analysis using a DC ion beam and a QMS o Static SIMS – used for atomic monolayer analysis using a pulsed laser and a TOF

Target of SIMS Studies Typically flat surfaces or rods – CuBe – Al Rapidly growing interest in studying 3D – Organometallics and films from metal or semiconductor surfaces These trends demand that the Mass Spectrometer have – Better Resolution – Higher Sensitivity – Mass Range Options

MAX-CS Probes are the Proven Solution Powerful research grade instruments. o Best performance of flange mounted systems o Heart of Extrel’s VeraSpec Mass Spectrometer Systems o Widest array of options of any of our systems Mass Ranges – 50, 120, 500, 1000, 4000, maximum masses – Based off of quad size + RF frequency Two Quadrupole Sizes MS/MS option Multiple ionization sources Conical aperture on the Ionizer can be located close to the substrate to ionize the desorbed neutral compounds o Energy Filter Ionizer to differentiate between secondary ions and ionized neutrals in the chamber o Has fine control of the ionizer to perform “soft” ionization to retain the molecular ion without fragmentation SIMS Analysis Features of MAX Probe Systems

MAX-LT Probes Provide a Quality solution at an Affordable Cost Research grade performance at an affordable price. – 500 and 1000 amu mass ranges – Positive and negative ion detection Typical applications – Thermal Programmed Desorption (TPD) – Plasma and Chemical Vapor Deposition (CVD) Analysis – UHV Residual Gas Analysis.

SIMS Analysis: Energy Filter Ionizer High Energy ions (1 keV – 100 keV) – Not easily analyzed by QMS – Should be blocked from entering the analyzer Center stop of the energy filter – Keeps neutrals from entering the analyzer Blocks line-of-sight. Excellent Energy Filtering – Cylindrical lens of energy filter – Bandpass lenses above and below the cylinder – Center stop Cone aperture – Allows close placement to the target surface Greater sensitivity to the sputtered plume On-axis energy filter – Fine energy scan – < 0.6 eV FWHM (full width at half maximum) resolution

SimION Modeling of the Energy Filter Ionizer

CuBe Experiment The SIMS spectra for the CuBe alloy were collected using: MAX-120 with a tandem ionizer/energy analyzer o 19 mm Quadrupole & 2.1 MHz QC Base pressure: 1.6x10 -9 Torr Primary ions: 2 keV Ar + ions Incident angle (angle between the sample surface normal and the axis of the ion gun): ~ 80° Collection angle (the angle between the sample surface normal and the axis of the SIMS probe): ~ 10° All of the SIMS spectra were acquired after the sample had been sputtered with a much higher current of the Ar + ions. o SIMS spectra are characteristic of the unoxidized sample surface Ions of different kinetic energy were selected by the energy analyzer Ions coming out of the energy analyzer were then mass analyzed by the quadrupole mass filter o The pass energy of the energy analyzer is set by the voltage applied to the main cylindrical lens of the energy analyzer and the kinetic energy of the selected secondary ions is close to the pass energy

SIMS Spectra: 4.8 eV Pass Energy Copper Beryllium surface analysis

SIMS Spectra: 13.5 eV Pass Energy Copper Beryllium surface analysis

SIMS Spectra: 20.2 eV Pass Energy Copper Beryllium surface analysis

SIMS Spectra: 30.0 eV Pass Energy Copper Beryllium surface analysis

SIMS Data Summary The Be+ and Cu+ ion intensities measured at different pass energies allowing for precise measurement of each compound Pass Energy (eV)Beryllium Intensity (m/z 9; kCPS) Copper Intensity (m/z 63; kCPS) <

Solutions to SIMS Analysis Characteristics of the secondary ions: o Absolute ion intensities depend on the pass energy o The Be-to-Cu ion intensity ratio changes with the pass energy The Be + and Cu + ions from the bombarded CuBe alloy surface have very different ion energy distributions Cu + ion intensity peaks around 20 eV Be + ions achieves its maximum intensity at a much lower kinetic energy

For More Information: Please visit us at Booth XXX Or on our website at Extrel.com