A Clustering Algorithm for LumiCal Halina Abramowicz, Ronen Ingbir, Sergey Kananov, Aharon Levy, Iftach Sadeh Tel Aviv University DESY Collaboration High.

Slides:



Advertisements
Similar presentations
CBM Calorimeter System CBM collaboration meeting, October 2008 I.Korolko(ITEP, Moscow)
Advertisements

Proposal for a new design of LumiCal R. Ingbir, P. Ruzicka, V. Vrba October 07 Malá Skála.
TAU Update MPI Munich meeting 17/10/2006 Luminosity Detector R&D Tel Aviv University Halina Abramowicz, Ronen Ingbir, Sergey Kananov, Aharon Levy, Iftach.
13/02/20071 Event selection methods & First look at new PCB test Manqi Ruan Support & Discussing: Roman Advisor: Z. ZHANG (LAL) & Y. GAO (Tsinghua))
P hysics background for luminosity calorimeter at ILC I. Božović-Jelisavčić 1, V. Borka 1, W. Lohmann 2, H. Nowak 2 1 INN VINČA, Belgrade 2 DESY, Hamburg.
Algorithm design for MAPS clustering Bradley Hopkinson / Birmingham Introduction: ● Using LDC01 detector model in Mokka ● MAPS Mokka geometry (Yoshi.
OD Calorimetry Study Update — Leakage Effect and relative calibration Jaewon Park University of Rochester MINERvA/Jupiter Group Meeting, May 31, 2006.
MC Study on B°  J/  ° With J/      °     Jianchun Wang Syracuse University BTeV meeting 03/04/01.
FMS review, Sep FPD/FMS: calibrations and offline reconstruction Measurements of inclusive  0 production Reconstruction algorithm - clustering.
Photon reconstruction and calorimeter software Mikhail Prokudin.
Effect of the Shape of the Beampipe on the Luminosity Measurement September 2008 Iftach Sadeh Tel Aviv University DESY.
Preliminary comparison of ATLAS Combined test-beam data with G4: pions in calorimetric system Andrea Dotti, Per Johansson Physics Validation of LHC Simulation.
Angular resolution study of isolated gamma with GLD detector simulation 2007/Feb/ ACFA ILC Workshop M1 ICEPP, Tokyo Hitoshi HANO collaborated with Acfa-Sim-J.
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Krakow2006.
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Cambridge ILC software tools meeting.
Precise Measurements of SM Higgs at the ILC Simulation and Analysis V.Saveliev, Obninsk State University, Russia /DESY, Hamburg ECFA Study Workshop, Valencia.
Jan MDI WS SLAC Electron Detection in the Very Forward Region V. Drugakov, W. Lohmann Motivation Talk given by Philip Detection of Electrons and.
International Workshop on Linear Colliders, Geneve Muon reconstruction and identification in the ILD detector N. D’Ascenzo, V.Saveliev.
Event Reconstruction in SiD02 with a Dual Readout Calorimeter Detector Geometry EM Calibration Cerenkov/Scintillator Correction Jet Reconstruction Performance.
Simulation of physics background for luminosity calorimeter M.Pandurović I. Božović-Jelisavčić “Vinča“ Institute of Nuclear Sciences, Belgrade, SCG.
Ivan Smiljanić Vinča Institute of Nuclear Sciences, Belgrade, Serbia Energy resolution and scale requirements for luminosity measurement.
Simulation and Analysis of VTX03 and Upgrades to LASS Ryan Page.
September, 19 FCAL Worlshop in Tel Aviv W. Lohmann, DESY Physics Requirements Input From Theory Lessons from LEP LumiCal Simulations BeamCal.
1Frank Simon ALCPG11, 20/3/2011 ILD and SiD detectors for 1 TeV ILC some recommendations following experience from the CLIC detector study
Development of a Particle Flow Algorithms (PFA) at Argonne Presented by Lei Xia ANL - HEP.
Bill Atwood, SCIPP/UCSC, May, 2005 GLAST 1 A Parametric Energy Recon for GLAST A 3 rd attempt at Energy Reconstruction Keep in mind: 1)The large phase-space.
Pandora calorimetry and leakage correction Peter Speckmayer 2010/09/011Peter Speckmayer, WG2 meeting.
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
CBM ECAL simulation status Prokudin Mikhail ITEP.
Electron Detection in the SiD BeamCal Jack Gill, Gleb Oleinik, Uriel Nauenberg, University of Colorado ALCPG Meeting ‘09 2 October 2009.
Calorimeter in front of MUCh Mikhail Prokudin. Overview ► Geometry and acceptance ► Reconstruction procedure  Cluster finder algorithms  Preliminary.
A Luminosity Detector for the Future Linear Collider Ronen Ingbir Prague Workshop HEP Tel Aviv University.
05/04/06Predrag Krstonosic - Cambridge True particle flow and performance of recent particle flow algorithms.
PFAs – A Critical Look Where Does (my) SiD PFA go Wrong? S. R. Magill ANL ALCPG 10/04/07.
Bangalore, India1 Performance of GLD Detector Bangalore March 9 th -13 th, 2006 T.Yoshioka (ICEPP) on behalf of the.
13 July 2005 ACFA8 Gamma Finding procedure for Realistic PFA T.Fujikawa(Tohoku Univ.), M-C. Chang(Tohoku Univ.), K.Fujii(KEK), A.Miyamoto(KEK), S.Yamashita(ICEPP),
Photon reconstruction and matching Prokudin Mikhail.
HEP Tel Aviv University LumiCal (pads design) Simulation Ronen Ingbir FCAL Simulation meeting, Zeuthen Tel Aviv University HEP experimental Group Collaboration.
Pad design present understanding Tel Aviv University HEP Experimental Group Ronen Ingbir Collaboration High precision design Tel-Aviv Sep.05 1.
1 D.Chakraborty – VLCW'06 – 2006/07/21 PFA reconstruction with directed tree clustering Dhiman Chakraborty for the NICADD/NIU software group Vancouver.
BESIII EMC Simulation & Reconstruction He Miao
1 Calorimeters of the Very Forward Region Iftach Sadeh Tel Aviv University DESY Collaboration High precision design March 5 th 2008.
HEP Tel Aviv UniversityLumical - A Future Linear Collider detector Lumical R&D progress report Ronen Ingbir.
The Luminosity Calorimeter Iftach Sadeh Tel Aviv University Desy ( On behalf of the FCAL collaboration ) June 11 th 2008.
1 LumiCal Optimization Simulations Iftach Sadeh Tel Aviv University Collaboration High precision design May 6 th 2008.
7/13/2005The 8th ACFA Daegu, Korea 1 T.Yoshioka (ICEPP), M-C.Chang(Tohoku), K.Fujii (KEK), T.Fujikawa (Tohoku), A.Miyamoto (KEK), S.Yamashita.
Tungsten-Silicon Luminosity Detector with Flat Geometry Ronen Ingbir Tel Aviv University High Energy Physics Experimental Group.
LumiCal background and systematics at CLIC energy I. Smiljanić, Vinča Institute of Nuclear Sciences.
The Surface Rejection with Position Information Gensheng Wang California Institute of Technology CDMS Collaboration Meeting, UCBS Feb. 11, 2005.
W Prototype Simulations Linear Collider Physics & Detector Meeting December 15, 2009 Christian Grefe CERN, Bonn University.
HEP Tel Aviv University Lumical R&D progress report Ronen Ingbir ECFA - Durham2004 Lumical - A Future Linear Collider detector.
Tracking software of the BESIII drift chamber Linghui WU For the BESIII MDC software group.
FCAL Krakow meeting, 6. May LumiCal concept including the tracker R. Ingbir, P.Růžička, V. Vrba.
Study of the Differential Luminosity Spectrum Measurement using Bhabha Events in 350GeV WANG Sicheng 王 思丞 Supervisor: André Sailer.
DESY BT analysis - updates - S. Uozumi Dec-12 th 2011 ScECAL meeting.
1 Dead material correction status. Alexei Maslennikov, Guennadi Pospelov. Bratislava/Kosice/MPI Calorimeter Meeting. 8-December Problems with DM.
Initial proposal for the design of the luminosity calorimeter at a 3TeV CLIC Iftach Sadeh Tel Aviv University March 6th 2009
On behalf of the Acfa-Sim-J Group
FCAL R&D towards a prototype of very compact calorimeter
Luminosity Measurement using BHABHA events
The Optimized Sensor Segmentation for the Very Forward Calorimeter
The reconstruction method for GLD PFA
Detector Configuration for Simulation (i)
Status of ECAL Optimization Study
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Using Single Photons for WIMP Searches at the ILC
Calorimeters of the Very Forward Region
Argonne National Laboratory
Current Status of EMC Reconstruction
Sheraton Waikiki Hotel
Presentation transcript:

A Clustering Algorithm for LumiCal Halina Abramowicz, Ronen Ingbir, Sergey Kananov, Aharon Levy, Iftach Sadeh Tel Aviv University DESY Collaboration High precision design Oct 6 th 2007

Detector design  Layer Gap mm  Silicon Thickness mm  Support Thickness mm  Tungsten Thickness mm  Inner Radius - 80 mm  Outer Radius mm  Phi Cell Size mrad  Theta Cell Size mrad  Crossing Angle - 0 mrad

 Shower-peak layers are those layers which contain a significant fraction of the total hits (normalized) Number of hits per layer Properties of an EM shower in LumiCal

Integration over all layers (after some energy cut) Moliere Radius Properties of an EM shower in LumiCal  The Molière radius is a global detector constant.  Energy spread increases for deeper layers.

Properties of an EM shower in LumiCal An example by way of reconstruction  The 2D center of mass (CM) of each cluster is computed using logarithmic weighting Only hits of high energy contribute.

1.Perform initial 2D clustering in shower-peak layers. 2.Extrapolate “virtual cluster” CMs in non shower-peak layers, and build real clusters accordingly. 3.Build (global) 3D “super clusters” from all 2D layer clusters. 4.Check cluster properties, and (try to) re-cluster if needed. Outline of the algorithm  Events were generated with BHWIDE (1.04) and simulated by Mokka(v p01) using Geant4(v4.8.1.p02). The super-driver LumiCalX of the LDC(00-03Rp) model was used to build LumiCal in Mokka.  The clustering algorithm was written as a Marlin processor, using Marlin(v ).

Nearest neighbor 2D clustering Find the highest energy neighbor of the selected cell Select the cell which Has just been registered Is the neighbor Unregistered ? YES Register it in the chain NO Select the cell and register it in a new chain of cells Go back to the previously registered cell Find the highest energy cell in layer Does the cell have any unregistered neighbors left? YESNO Are we back at the first Cell we started with ? YESNO Is there another unregistered cell in the layer? YESNODONE  Six near neighbors are considered (one/two steps in the radial direction and one step in the azimuthal direction). This is due to the fact that the granularity in the radial direction is much better than the azimuthal one.  After all is said and done, clusters consisting of one cell only are merged with their highest energy neighbor.  This algorithm only work for shower-peak layers where the number of hits is high (at least 4% of the total number of hits in the detector arm). Select one of them Each chain of connected cells is now a cluster.

Nearest neighbor 2D clustering 1.Each cell connects to its highest energy neighbor. 2.Small local clusters are created from the groups of connected cells.  Initial clustering does not use low energy hits (hit must be of the total energy in the detector arm).  This only work for the shower-peak layers where there are many hits.  Free Parameters: - Who are a cell’s near neighbors? - What’s the minimal number of hits that makeup a shower-peak layer? - Which cells are considered as near neighbors? (Each circle-color represents a different cluster)

2D Cluster merging (in small steps)  Still too many clusters remain: - 4 clusters (red, blue, black, green). - 2 particles.  Clusters must be merged carefully to maintain separation of the different particles.

2D Clustering in non shower-peak layers Set the number of global clusters (majority rule) Fit straight lines through cluster CMs and extrapolate virtual-cluster CMs in non shower-peak layers Add small energy hits to existing clusters Create clusters in non shower-peak layers by adding hits inside around the virtual-cluster CMs Fix shower-peak Layers which have the wrong number of clusters Merge 2D layer clusters into global 3D super-clusters

Molière Radius corrections  Two clusters (blue & red full circle) are merged by mistake (green hallow circle).  Inside a cluster’s Molière radius should be found ~90% of the cluster’s total energy.

Molière Radius corrections If for all clusters together E In Molière < 90%, or if for any single cluster E In Molière < 80%, Build new projection-clusters YESNO Is (E In Moli è re < 80%) for each of the projection-clusters? Raise the minimal cell energy threshold Are there enough cells remaining? Correction failed Check if the projection- clusters are an improvement on the original clusters NOYES Correction Successful YESNO

Physics sample - Bhabha events Limits on that prevent leakage Bhabha events Calibration of the detector-signal to energy

So… does it all work?  Choose a cut on energy of 15 [GeV] and integrate clusters that are closer than one Molière radius.

So… does it all work?  Some numbers: (30,000 Bhabha events) - For a minimal separation distance of one Molière radius we have: - Separated well clusters - Not separated - 57 clusters - Miss-separated - 40 clusters - For a minimal separation distance of two Molière radius we have: - Separated well clusters - Not separated - 35 clusters - Miss-separated - 4 clusters (The purity goes to ~ 99%)

Results - Position reconstruction

Results - Energy reconstruction Has yet to be optimized…

Summary 1.A clustering algorithm is being developed for LumiCal. 2.For a Bhabha event sample, with a cluster energy cut of 15 GeV, and cluster separation of at least one Molière radius, position resolution of better than 0.1% is achieved. 3.Under these constraints, the acceptance and efficiency are 95%, while the purity is 97%. 4.Energy resolution still requires further studies. 5.Next steps also include optimization of the free parameters of the algorithm, as well as variations in LumiCal geometry.