High Voltage Test System Results, 03-04/07 J. Long, Indiana University System Overview and Modifications Readout system Breakdown tests of acrylic System.

Slides:



Advertisements
Similar presentations
D. Lipka, MDI, DESY Hamburg; Temperature Simulation DCCT at PETRA III D. Lipka, MDI, DESY Hamburg.
Advertisements

Analog Basics Workshop RFI/EMI Rejection
Sputter Stand Safety Specifics Electrical Hazards High Voltage : Electrical power is required for the high voltage supply, gauging, system controller and.
INSTITUT MAX VON LAUE - PAUL LANGEVIN Fast Real-time SANS Detectors Charge Division in Individual, 1-D Position- sensitive Gas Detectors Patrick Van Esch.
Atsuhiko Ochi Kobe University 4/10/ th RD51 collaboration meeting.
©2012 Fluke Corporation SPRT Health 1 Health Monitoring of SPRTs.
High Voltage Studies, 10/06 – 02/07 J. Long, Indiana University System Modifications Conditioning tests Amplification, leakage current (preliminary) Future.
ELECTROCARDIOGRAM (ECG)
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
Aging, High Rate and Shielding L. Lopes Lip-Coimbra.
High voltage test system update Summary of 2005 results Results from March, May 2006 Possible remaining R&D projects Polished electrodes, clean(er) LHe.
PHYS 142 CH 26 Sarah Eno1 Materials for Lecture Poling cards Demos:
Hans Jostlein, Lar Workshop, November 4, Liquid Argon TPC High Voltage Issues.
New Readout Methods for LAr detectors P. Otyugova ETH Zurich, Telichenphysik CHIPP Workshop on Neutrino physics.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
MICE Target Status Chris Booth Sheffield 10 th May 2006.
Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun.
Test of the high voltage strength of Pelletron’s gas insulation (18-Dec-2008) Recycler Meeting January 21, 2009 A. Shemyakin.
LUMI 1 LUMI Mechanical Design Details Bill Ghiorso.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
09/16/2010© 2010 NTUST Today Course overview and information.
LISA STUDIES AT THE UNIVERSITY OF COLORADO Michael J. Nickerson, Ellery B. Ames, John L. Hall, and Peter L. Bender JILA, University of Colorado and NIST,
STRIPLINE KICKER STATUS. PRESENTATION OUTLINE 1.Design of a stripline kicker for beam injection in DAFNE storage rings. 2.HV tests and RF measurements.
LBNL Test Cryostat Preliminary Design Review Tuning – Field Correction Soren Prestemon, Diego Arbelaez, Heng Pan, Scott Myers, Taekyung Ki.
Chamber parameters that we can modify and that affect the rising time Number of ionisation clusters produced in the drift gap: Poisson Distribution Probability.
HBD Meeting 3/14/06 B. Azmoun BNL Testing and Preparation of HBD Full Scale Prototype for Upcoming Engineering Run Puzzling Behavior of GEM’s To Do List.
Electrostatic Septum For AGS C. Pai Brookhaven National Laboratory Collider-Accelerator Department
Malte HildebrandtDC Status Report, Dear MEG Committee,PSI, April 14 th 2009 this is the first report concerning the drift chamber status as.
Results from the HV Test System Review of current design and assembly J. Long, P. Barnes, J. Boissevain, J. Gomez, S. Lamoreaux, D. Mischke, S. Penttila.
W. Morse PEDM Review1 E/B PEDM R&D W. Morse 12/7/2009.
Scanning Electron Microscope (SEM)
Preliminary HV Results in Superfluid Helium Review of HV system design J. Long, J. Boissevain, J. Gomez, S. Lamoreaux, S. Penttila LANL Amplification and.
Design and Technical Challenges of the ILC Small Angle Interaction Regions October 19 th, 2006J. Borburgh, CERN, AB/BT Electrostatic separator limits With.
CERN ISOLDE / HIE ISOLDE 1 Isolde Target Modulator Prototype development prepared by T. Gharsa TE-ABT-EC CERN.
SQUID Performance in a HV Environment
ELECTRONIC INSTRUMENTATION & PLC DKT Signal Conditioning Circuits.
Sheffield : R. Hollingworth, D. Tovey R.A.L. : R.Luscher Development of Micromegas charge readout for two phase Xenon based Dark Matter detectors Contents:
Update on SBS Back Tracker UVa K. Gnanvo, N. Liyanage, V Nelyubin, K. Saenboonruang, Seth Saher, Nikolai Pillip (visiting from Univ. Tel Aviv, Israel)
HV-SQUID Compatibility Test Study the SQUID performance in a HV environment. Study the HV breakdown –in superfluid under pressure. –using different materials.
RPCs of BESIII Muon Identifier  BESIII and muon identifier  R&D  Mass production  Installation Zhang Qingmin Advisor: Zhang Jiawen.
Long Bo for LAPD Hans Jostlein10/20/2011 December 15, 2015 Long Bo for LAPD 1.
Investigation of effects associated with electrical charging of fused silica test mass V. Mitrofanov, L. Prokhorov, K. Tokmakov Moscow State University.
Plans for HV R&D at LANL Vacuum chamber Supply cryostat Josh Long, Indiana U. Tests in progress Control purity, contaminants, attempt T < 1.8 K Near Future.
Results from the CMS-RPC tests at CERN Gamma Irradiation Facility Roberto Guida CMS-RPC (Bari, Beijing, Napoli, Pavia, Sofia) Seoul, October 2005.
Dielectric Strength of Superfluid Helium Under Pressure Small Pressure-Controlled Cryostat Overview Measurement Cycle Possible Breakdown Mechanisms Dielectric.
DC Spark Developments Nick Shipman - Thursday, 16 August
CLAS12 Drift Chamber Prototyping
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
The Simulation of the HEC What is presently in the description in GeoModel as presented by Joe Boudreau versus What should be in…
Status of the HV Test System Purposes of the HV test system Design and assembly progress Vacuum enclosure Projected assembly and test milestones (short-term)
Kerr Effect-based Measurement of the Electric Field
Recent progress in large THGEM production On behalf of Trieste group and Rui de Oliveira (CERN) S. Levorato RD51 mini week1.
Concept Design for LBNF Far detector (LAr single phase)
Mike Struik / LHC-CRI INSTRUMENTATION FEEDTHROUGH SYSTEM FOR LHC MACHINE ARC QUADRUPOLE MAGNETS. 123rd LHC Vacuum Design Meeting 19 April 1999.
NUMI Primary Beam Review August 14, 2001 NUMI PRIMARY BEAM INSTRUMENTATION Multiwires, Loss Monitors, Toroids Gianni Tassotto.
BY Parmar Anjali Singh Sweta
Recent Changes to the FD TPC Design Bo Yu Oct. 20, 2015.
PSB extraction and transfer kickers LIU TE-ABT review, 20 November L. Sermeus.
MicroBooNE High Voltage System and Feedthrough MicroBooNE Collaboration Meeting Hans Jostlein, December 3,
Electric Pressure Transducer
Installation of the T600 at Fermilab
USING HIGH TEMPERATURE CAMERAS TO MEASURE:
The High Voltage problem
Quality Control Chamber Production
First tests on the roll-formed field cage.
LHC BLM system: system overview
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
The Quench Detection-Wire-Feedthrough Plug-In of W7-X
Report 17 Kelvin's dropper
Liquid Argon TPC High Voltage Issues
Presentation transcript:

High Voltage Test System Results, 03-04/07 J. Long, Indiana University System Overview and Modifications Readout system Breakdown tests of acrylic System performance away from breakdown Direct monitoring of resting current

stainless can aluminum plate wire seal flange G-10 standoff HV plunger control rod Indium seal ceramic standoff HV electrodeground electrode ground control rod Vacuum-LHe HV feedthrough bearings bellows 0.53 m quartz window High voltage system prototype at LANL Vacuum chamber Supply cryostat HV feedthrough Actuator Test proposed amplification method Measure breakdown properties of large volumes of LHe Existing data: 150 kV/cm at 4 K, 1cm gap LHe bath pumping line

Previous results from prototype system Maximum leakage currents under these conditions (95% C. L.) : SF (2.07 K): 733 pA Normal State (3.98 K): 169 pA Short-duration breakdown not affected by neutron radiation (10 6 /s, ~MeV) Small commercial HV feedthrough exceeded maximum rating in air (40 kV) by 25% when immersed in SF Maximum potentials sustained: 11.8 liters Normal State (4.38 K), 7.2 cm gap: (96 ± 7) kV/cm 12.8 liters SF at 2.14 K, 7.8 cm gap: (31 ± 3) kV/cm Possible further degradation below 1.9 K Bubble formation (common breakdown culprit) observed when charging above 10 kV, likely coincident with noise

HV System – Previous modifications : “Common sense” improvements Polished electrodes, plasma discharge cleaner (for Hydrocarbons), dry pumps only, LN2 traps on pumps, pre-cool with cold He gas, basic LHe filtering, attempt electrode conditioning Results: no improvement (pitting, contamination, mechanical failure, discharges behind HV electrode)

Acrylic Breakdown Tests Replaced ceramic standoffs behind HV electrode with acrylic Advantages Poor match of actual perimeter of reference cell design Reference cell perimeter = 2 (50 cm + 10 cm) = 120 cm Total perimeter of standoffs = 44 cm More expensive than slab between electrodes (?) Disadvantages Hollow construction possible Leakage current monitoring comparable to baseline (ceramic) Avoids problems associated with holding objects between electrodes Strong fields (60 kV/cm) available at gaps comparable to reference gap Mimic electrode recesses without modifying electrodes Field behind HV electrode less uniform

Modified Standoff Design for Acrylic Breakdown Tests 6” long, 2” diameter acrylic tube replaces ceramic Steel end pieces same dimensions as on ceramic, mimic recesses John Ramsey, LANL

Modified Standoff Design for Acrylic Breakdown Tests Spring-loaded retaining ring holds acrylic annulus in place against slipping from thermal contraction John Ramsey, LANL

Condition of HV electrode – 12/06 and 02/07 runs Fill-holes and scratches Shim with sharp edges

Installation of acrylic – 04/07 runs Holes patched and polished (insulators have through-holes) No shims necessary

Capacitances Relevant to Voltage, Currents

C HG C HC C HP Capacitances Relevant to Voltage, Currents (cont.) C HF

C HG HVPS 50 kV A C C HC C HP Basic Charging and Readout Circuit A P A G C HF SR570 current amplifier (pA)

Readout - details

Amplification Measurement C HG C HP A P A G C HC A C A P A G A C i - i

Amplification Measurement C HG C HP A P A G C HC A C A P A G A C i - i Easiest (stays fixed, large gap, smaller errors)

Amplification Measurement C HG C HP A P A G C HC A C A P A G A C i - i Easiest (stays fixed, large gap, smaller errors)

Maximum voltages attained – 04/07 Maximum potentials sustained: 10.5 liters Normal State (4.38 K), 6.4 cm gap: (760 ± 70) kV = (119 ± 11) kV/cm 8.2 liters SF at 2.14 K, 5.0 cm gap: (290 ± 40) kV = (58 ± 8) kV/cm RangesComparison with previous results (means) ~20% improvement with extrapolation to 7.5 cm gap

Improved initial gap capacitance Capacitance of HV electrode at small electrode gap: Can now charge larger ( ~ 25%) initial capacitance to same initial voltage (35-40 kV): expect ~ 25% improvement Range of start gaps, 4/07 Previous start gap Likely the result of careful shimming of gap before 4/07 tests

V 0 > 0.95 V 0 MAX V 0 ~ 0.8 V 0 MAX V 0 ~ 0.5 V 0 MAX 4.4 K (18 tests)6/68/84/4 2.1 K (14 tests)0/42/42/6 V0V0 T Charging “statistics:” Established initial gap breakdown of V 0 MAX # successes # attempts to charge at some fraction of V 0 MAX System performance at and below maximum voltage Recorded: V 0 > 0.95 V 0 MAX V 0 ~ 0.8 V 0 MAX V 0 ~ 0.5 V 0 MAX 4.4 K (18 tests)2/6(?)0/80/4 2.1 K (4 tests)0/01/20/2 V0V0 T Number of breakdowns during amplification:

Leakage Current 04/07 – Traditional Method  Q HV = (0.3 ± 2.4) nC i LEAK ≤ 220 pA (95% C. L.) _ AVERAGE leakage current along ALL paths during holding time  t between amplification (moving out) and attenuation (moving in):  Q HV = (-0.4 ± 16) nC i LEAK ≤ 5 nA (95% C. L.) _ 4.4 K (  t ~ 7 hr): 2.1 K (  t ~ 11 min):

Resting Current 04/07 – Direct monitoring Leave system at maximum gap Set current amplifiers to maximum possible sensitivity (resolution ~ 0.01 pA [?]) Take data at 500 Hz (input filter: 100 Hz, 12 dB/octave) for ~ 500 s InsulatorsGND electrode Charger 0 kV 150 kV 290 kV 2.1 K data: N/A (bad connection)?

0 kV 150 kV 290 kV ~ 1s time slices of Insulator current data (60 Hz) (no obvious scaling)

InsulatorGroundCharger 0(offset) NA NA61.7 ch V Resting Current 04/07 – Direct monitoring Average current (pA), 2.1 K data Avg Insulator current vs voltage

InsulatorGroundCharger 0(offset) NA-59.0 Resting Current 04/07 – Direct monitoring Average current (pA), 4.4 K data Avg Insulator current vs voltage

Resting current spectra – 4K Sample rate = 500 Hz Amplifier input filter 100 Hz, 12 dB/octave Insulators: Ground electrode:

Resting current spectra – 4K Sample rate = 500 Hz Amplifier input filter 100 Hz, 12 dB/octave Charger:

Resting current spectra – 4K mean values at ~ 50 Hz (picometer oscillations cause 100 fA currents??) A/m Transducer effect?

Resting current spectra – 4K and 2K Sample rate = 500 Hz Amplifier input filter 100 Hz, 12 dB/octave Insulator data only Factor ~ 10 greater noise below 10 Hz Mean amplitude decreases with applied voltage Beating of 2 additional pumps? (switching off pumps does NOT improve breakdown)

Resting current spectra – 4K, pumps off Sample rate = 500 Hz Amplifier input filter 100 Hz, 12 dB/octave Insulator data shown LHe boil-off increases significantly (“white” effect?) over course of measurement

Resting current spectra – 4K, HV fixed vs floating Insulators: Ground electrode: Set gap to 2.3 cm (ground connection OK) Applied 40 kV with charger fixed to HV Took ~ 5 min. data Retracted charger Took ~ 5 min. data Time-averaged insulator currents: 0.05 pA (HV floating) 0.18 pA (HV fixed)

Conclusions Initial capacitance, smooth electrode features crucial factors in system performance No obvious breakdown / leakage current problems with (uncoated) acrylic Stability/performance of system below 2.2 K (35 torr) still serious concern Some trends in dc and ac resting current with applied voltage and fixed vs floating HV electrode, but no serious degradation Readout needs improvement for sensitivity to small signals

V 0 > 0.95 V 0 MAX V 0 > 0.8 V 0 MAX V 0 > 0.5 V 0 MAX 4.4 K (18 tests)6/614/1418/ K (14 tests)0/42/84/14 V0V0 T Charging “statistics:” Established initial gap breakdown of V 0 MAX # successes # attempts to charge above some fraction of V 0 MAX System performance at and below maximum voltage Recorded: V 0 > 0.95 V 0 MAX V 0 > 0.8 V 0 MAX V 0 > 0.5 V 0 MAX 4.4 K (18 tests)2/62/142/ K (4 tests)0/01/21/4 V0V0 T Number of breakdowns during amplification:

John Ramsey, LANL Design finished this week Procurement by end June Need technician to assemble and install New inner (4K) shield

Leakage Current 12/06 – Traditional Method  Q HV = (6.8 ± 2.6)  C i LEAK = (8.6 ± 3.3) nA _ AVERAGE leakage current along ALL paths during holding time  t between amplification (moving out) and attenuation (moving in):

Leakage current 12/06 – Direct Monitoring Output of current amplifier on plate (insulators): Current (nA) vs time (s) Integrated Current (  C) vs time (s) 4

Leakage current 12/06 – Direct Monitoring Q P = 4.4 ± 0.1  C (zero drift only) Output of current amplifier on plate (insulators): Current (nA) vs time (s) Integrated Current (  C) vs time (s) 4 i LEAK = (5.5 ± 0.2) nA _

Leakage current 12/06 – Direct Monitoring Q P = 4.4 ± 0.1  C (zero drift only) Output of current amplifier on plate (insulators): Current (nA) vs time (s) Integrated Current (  C) vs time (s) 4 i LEAK = (5.5 ± 0.2) nA _  Q HV = (6.8 ± 2.6)  C i LEAK = (8.6 ± 3.3) nA _ Consistent with traditional result but room for several nA leakage elsewhere

Leakage current 12/06 – Direct Monitoring Q G = 2.21 ± 0.07  C (zero drift only) Output of current amplifier on ground electrode: Integrated Current (  C) vs time (s) Current (nA) vs time (s) -8

Leakage current 12/06 – Direct Monitoring Q G = 2.21 ± 0.07  C (zero drift only) Output of current amplifier on ground electrode: Integrated Current (  C) vs time (s) Current (nA) vs time (s) -8 A P A G A C i + i - i A P A G A C Expectation if +6.8 nC leaked off HV via path other than C HG :