Electron Probe Microanalysis EPMA Related Topics: Secondary X-ray Fluorescence (XRF) and Synchrotron Radiation.

Slides:



Advertisements
Similar presentations
NUCP 2371 Radiation Measurements II
Advertisements

X-rays Long Wave IR Visible UV X-rays Gamma rays wavelength (nm) Frau Röntgen's hand.
Instrumental Chemistry
Bragg’s Law nl=2dsinΘ Just needs some satisfaction!! d Θ l
Page 1 Wave / Particle Duality PART I Electrons as discrete Particles. –Measurement of e (oil-drop expt.) and e/m (e-beam expt.). Photons as discrete Particles.
X-ray Diffraction. X-ray Generation X-ray tube (sealed) Pure metal target (Cu) Electrons remover inner-shell electrons from target. Other electrons “fall”
Electron Probe Microanalysis EPMA Related Topics: X-ray Fluorescence (XRF) and Synchrotron Radiation Revised 5/23/2014.
Interference and Diffraction
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
X-Ray Crystallography The most important technique for mineralogy The most important technique for mineralogy Direct measurement of atomic arrangement.
Stanford Synchrotron Radiation Lightsource Sources and Optics for XAS Apurva Mehta.
Spectroscopy. Spectroscopy is complex - but it can be very useful in helping understand how an object like a Star or active galaxy is producing light,
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
Light. Photons The photon is the gauge boson of the electromagnetic force. –Massless –Stable –Interacts with charged particles. Photon velocity depends.
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
What is the nature of Part II. Last week we surmised that photons must carry momentum in spite of the fact that they are massless. Last time we learned.
Instrumental Chemistry Chapter 12 Atomic X-Ray Spectroscopic.
Fiber-Optic Communications James N. Downing. Chapter 2 Principles of Optics.
Chapter 5 Basic properties of light and matter. What can we learn by observing light from distant objects? How do we collect light from distant objects?
Interactions with Matter
What is the nature of Part II. Last week we surmised that photons must carry momentum in spite of the fact that they are massless. Last time we learned.
Instrumentation - making & detecting x-rays Read Roe - Chap 2 through (ignore neutrons)
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Common types of spectroscopy
1 M. Aslam Baig National Center for Physics Quaid-i-Azam University Campus, Islamabad Pakistan
To Atomic and Nuclear Physics to Atomic and Nuclear Physics Phil Lightfoot, E47, (24533) All these slide presentations are at:
III. Analytical Aspects Summary Cheetham & Day, Chapters 2, 3 Chemical Characterization of Solid-State Materials Chemical Composition: Bulk, Surface, …
X-rays are electromagnetic waves (like light) and have a wavelength about the size of atoms. From
Chapter 7 X-Ray diffraction. Contents Basic concepts and definitions Basic concepts and definitions Waves and X-rays Waves and X-rays Crystal structure.
Chapter 3 Light and Matter
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
Lecture 11b Atomic Physics & Nuclear Reactions Copyright © 2009 Pearson Education, Inc.
Chapter 12 Atomic X-Ray Spectroscopy
Tools for Nuclear & Particle Physics Experimental Background.
Space Instrumentation. Definition How do we measure these particles? h p+p+ e-e- Device Signal Source.
Scanning Electron Microscope (SEM)
The Particlelike Properties of Electromagnetics Radiation Wei-Li Chen 10/27/2014.
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
X-Ray Diffraction Dr. T. Ramlochan March 2010.
Last time we defined a crystal as a solid containing translational symmetry. The directions of translation can be used to from a unit cell. A primitive.
Chapter 3 in Massa X-rays What are they? How are they produced? How do x-rays interact with matter? How does the nature of the crystal effect that interaction?
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Other modes associated with SEM: EBIC
Medical Imaging Radiation I. Naked to the Bone: Medical Imaging in the Twentieth Century (Paperback)by Bettyann Kevles Bettyann Kevles E=mc2: A Biography.
LIGHT and MATTER Chapters 12 and 13. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
Plan : intro Characterization of thin films and bulk materials using x-ray and electron scattering V. Pierron-Bohnes IPCMS-GEMME, BP 43, 23 rue du Loess,
Spectrophotometry.
Introduction to Synchrotron Radiation
© 2007 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
1 Spectroscopic Analysis Part 2 – Electromagnetic Radiation Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett Water Studies Centre.
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Gamma ray interaction with matter A) Primary interactions 1) Coherent scattering (Rayleigh scattering) 2) Incoherent scattering (Compton scattering) 3)
Chapter 25 Electromagnetic Waves. Units of Chapter 25 The Production of Electromagnetic Waves The Propagation of Electromagnetic Waves The Electromagnetic.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 2 Light and Matter.
X-ray absorption spectroscopy (XAS)
Plan for Today (AP Physics 2) Ch 24, 27, and 28 Review Day More Review Materials.
LIGHT and MATTER Chapters 11 & 12. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
Graphical Analysis and Applications of Photoelectric Effect
How do we know? Spectroscopy: Experimental Evidence.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
 Matter is any thing that occupies space & has mass  Present in three states: solid, liquid, & gas  It could be divided into elements & compounds 
X-RAY METHODS FOR ORIENTING CRYSTALS
Presentation on.  There are many methods for measuring of fiber structure. Such as:  The absorption of infrared radiation  Raman scattering of light.
© 2017 Pearson Education, Inc.
Instrument Parameters in WDXRF
Electron Probe Microanalysis EPMA
Electron Probe Microanalysis EPMA
Scintillation Counter
Radhabai Kale Mahila Mahavidhyalaya, Ppt. name:- x-Ray techniques
Presentation transcript:

Electron Probe Microanalysis EPMA Related Topics: Secondary X-ray Fluorescence (XRF) and Synchrotron Radiation

What’s the point? We utilize the x-rays produced by the electron microprobe for many research applications. There are other techniques, similar in some ways, that are worth discussing, that utilize x-rays for secondary x-ray fluorescence. Two in particular are: XRF (X-Ray Fluorescence), where x-rays from a sealed tube are used to produce x-rays by secondary fluorescence in samples of interest (traditionally a macro-technique) Synchrotron Radiation, where electrons are accelerated in ~10s- 100s meters diameter rings, and then made to produce highly focused beams of extremely intense x-rays or light, which are then fed into many different types of experiments. The benefits of secondary x-ray fluorescence include very low detection limits (10s of ppm easy in 10 seconds, no backgrounds)

XRF Basics The basics of XRF are very similar to those of EPMA—we are dealing with characteristic x-rays and continuum x-rays— with the exception that we are doing secondary fluorescence : x-ray spectroscopy of our samples using x-rays coming out of a sealed tube to excite the atoms in our specimen. The big difference is that there is NO continuum generated in the sample (x-rays can’t generate the Bremsstrahlung), and we are using BOTH characteristic x-rays of the sealed tube target (e.g., Cr, Cu, Mo, Rh) AND continuum x-rays to generate the characteristic x-rays of the atoms in the sample. XRF has been a bulk analytical tool (grind up grams of your rock or sample to analyze), though recently people are developing “micro XRF” to focus the beam on a ~100  m spot.

X-ray Sources The standard X-ray tube (top right) was developed by Coolidge (at GE) around It is desirable to produce the maximum intensity of x-rays; a Cu target tube might be able to deliver 2 kW. The limiting factor is the heat that the target (anode) can handle; cold water is used to remove heat. Higher power can be delivered by dissipating the heat over a larger volume, with a rotating anode (bottom right). However, this is not normally used for XRF. * Power in watts = current [amps] x voltage [volts] From Als-Nielsen and McMorrow, p. 31

X-ray Attentuation This figure shows the attenuation of the X-rays in the target (sample). In addition to photoelectric absorption (producing characteristic X-rays and photoelectrons [=Auger electrons]), the original X-rays may be scattered. There are two kinds of scattering: coherent (Rayleigh) and incoherent (Compton). X-ray TARGETTARGET characteristic (Rayleigh) (Compton)

X-ray Scattering Coherent scattering happens when the X-ray collides with an atom and deviates without a loss in energy. An electron in an alternating electromagnetic field (e.g. X-ray photon), will oscillate at the same frequency (in all directions). This is useful for understanding X- ray diffraction (in depth). Incoherent scattering is where the incident X- ray loses some of its energy to the scattering electron. As total momentum is preserved, the wavelength of the scattered photon increases by the equation (in Å) where  is the scatter angle. Since  is near 90°, there will be an addition peak from the main tube characteristic peak at about 0.024Å higher wavelength Coherent Incoherent

Compton Scattering Peaks The top figure shows a wavelength spectrum of the Mo Ka peak from the x- ray tube. The other 3 figures show the splitting of the primary Mo Ka peak into a Compton Scattering Peak due to the incoherent scattering in an Al target, and the effect of changing the scattering angle. From Liebhafsky et al, 1972

Continuum of X-ray Tube in XRF Secondary fluorescence by x-rays in the sample does not produce continuum x-rays there. However, the continuum is produced within the selected x-ray tube which is the “gun” in XRF. This continuum is of interest here as it is useful for excitation source in XRF. Kramers (1923) deduced the relationship between continuum intensity, wavelength and atomic number of the x-ray source (“target”): where the x-ray intensity I is a function of x-ray tube current i, Z is the mean Z of the target and min is the E0 equivalent.

Kramers Law and Continuum Intensity Some comments: for maximum XRF counts, you want to maximize your current (I) and minimize your min which is to say 12.4/E0 …or… run at the highest accelerating voltage your x-ray tube can handle (40-50 keV) obviously, the higher the Z of the target in the tube, the higher the counts finally, Kramers Law is sometimes used in EPMA for theoretically modelling the Bremsstrahlung there From Williams, Fig 2.2

On spectral presentation: XRF Why do these look so different from our “normal” EDS view of a spectrum?????

XRF spectrometer An XRF spectrometer is very similar to an electron microprobe: just replace the electron gun with an x-ray tube located very close to the specimen;both the characteristic and the continuum x-rays cause (secondary) fluorescence of the specimen, and the resulting x-rays are focused using collimators in either WDS (crystal + counter) or EDS (solid state detector) mode. Fig 4-1 Williams

A Currently Marketed XRF (WDS version) This actual model contains additional components. There are probably over a dozen companies building and selling XRFs of various designs. In fact, two are here in Madison: Bruker-AXS (~Siemens) and ThermoNORAN (microXRF) From Bruker-AXS brochure

Sample Prep in XRF Samples and standards (fine powders) are mixed with a flux (e.g., a glass disk with ~90% LiBO 4 for major elements, a pressed pellet with ~75% cellulose for traces). The purpose is to minimize “particle size / micro- absorption effects” by producing a more uniform absorption path for samples made of discrete phases that may not have been ground down into submicron sizes.

Correction of XRF Intensity Data XRF intensity data (counts) is much simplier to correct, compared with EPMA data: No Z (atomic number) correction No F (fluorescence) correction Only A (absorption) correction Calibration curves are developed for each element.

Synchrotron Radiation (SR) - Defined* Synchrotron = particle (electron, proton, neutron) accelerator. The particle orbits a track; acceleration is produced by an alternating electric field that is in synchronism with orbital frequency. SR = electromagnetic radiation (e.g. radio waves, X-rays) generated within a synchrotron, or through similar natural process in deep space (e.g. some of strongest celestial radio sources). Electrons or other charged particles moving in a strong magnetic field field are forced to spiral around magnetic lines of forces. If they travel near speed of light, they emit, in direction of travel, a sharp beam of electromagnetic radiation polarized normal to the direction of magnetic field. Whether radiation appears as light or radio waves depends on its frequency, which is determined by the electrons’ velocity. * Encyclopedia Britannica, 1974

Synchrotron Setup From Als-Nielsen and McMorrow

Shown here is the cone of x- rays generated by positrons moving with near-speed-of- light energy through an insertion device. The array of permanent magnets produces a magnetic field that alternates up and down along the positron path, causing the particles to bend back and forth along the horizontal plane. At each bend, the positrons emit synchrotron radiation in the x-ray part of the spectrum. From The Advanced Photon Source at Argonne National Laboratory, October 1997 brochure Wigglers or Undulators and X-rays

From The Advanced Photon Source at Argonne National Laboratory, October 1997 brochure In x-ray scattering experiments, an x- ray beam is passed through a sample, and the intensities and directions of the scattered x-rays are measured. The pattern of scattered x-rays is converted by the computer into information about the arrangement of atoms in the sample. Synchrotron X-ray Diffraction

From The Advanced Photon Source at Argonne National Laboratory, October 1997 brochure A monochromator and a pinhole are used to select the coherent, laser-like part of an x-ray beam from an APS undulator. This beam is then focused to a tiny spot by a zone plate and directed at a sample being studied. As the sample is scanned back and forth across the beam spot, the x-rays transmitted through the sample are recorded in a computer. The data are then used to develop an image showing the structure of the sample Synchrotron X-ray Microscopy

Synchrotron X-ray Spectroscopy A beam of x-rays passes through a sample and a measurement is made of the degree to which x-rays of different energies are absorbed by the sample. One type of x-ray spectroscopy is called extended x- ray absorption fine structure, EXAFS. In EXAFS spectra, weak oscillations indicate the effect of scattering from neighboring atoms by an electron ejected from the atom that absorbs an x-ray. This involves electron scattering effects, rather than the x-ray scattering effects described in the previous slide. The weak oscillations in EXAFS spectra can be analyzed by computer models to infer the relative locations of atoms in the structure.

Advances with X-ray source brightness with time From Als-Nielsen and McMorrow UW-MSN SRC

UW-Madison Synchrotron Radiation Center (Stoughton) In 1965 construction began on the 240 MeV electron storage ring Tantalus “for advanced accelerator concepts” tests. But before its completion in 1968, interest in synchrotron radiation research soared, and changes were made to accommodate SR. And it then became dedicated to SR, and here many breakthroughs were made, e.g., the superiority of the electron storage ring as a source of SR was first shown. In 1977, SRC began construction on a new and much larger SR source, Aladdin (1 GeV storage ring). The SRC storage ring beamlines are optimal for ultrahigh vacuum ultraviolet (vuv) and soft x-ray (sxr) research.

UW-Madison SRC Aladdin was constructed with 36 beam ports, and 4 long straight sections for insertion devices like undulators and wigglers. There are 26 beamlines in operation and 5 under development*. The SRC serves the requirements for many investigations, including: high resolution optical absorption spectroscopy of solids and gases high resolution reflectance spectroscopy of solids photoinduced luminescence in solids and gases photoabsorption, dissociation and ionization cross section measurements chemisorption and physisorption studies modulation spectroscopy * 1996 literature quote. photoelectron diffraction x-ray lithography x-ray microscopy intrared spectroscopy and microscopy (FT-IR)

Resources for XRF and Synchrotron Introduction to X-Ray Spectrometry by K. L. Williams, 1987, Allen & Unwin (covers both XRF and EPMA) X-Rays, Electrons, and Analytical Chemistry by Liebhafsky, Pfeiffer, Winslow and Zemany, 1972, Wiley (title says it all) Elements of Modern X-Ray Physics by Als-Nielsen and McMorrow, 2001, Wiley Synchrotron powder diffraction by L.W. Finger, in Modern Powder Diffraction (Bish and Post, eds) Reviews in Mineralogy Vol 20, 1989, Min. Soc. Am.