Harmonic Deconvolution in Ultrasound Vibro-Acoustic images Alexia Giannoula Communications group, Dept of Electrical & Computer Engineering, University.

Slides:



Advertisements
Similar presentations
5.4.2 Diagnosis methods in medicine
Advertisements

Coulomb or Dry Friction Damping.
PHYSICS OF MAGNETIC RESONANCE
Foundations of Medical Ultrasonic Imaging
Non-linear acoustics in Ultrasound Imaging Hans Torp Department of Physiology and Biomedical Engineering NTNU NTNUNorway Hans Torp NTNU, Norway.
Forces and Motion Essential Vocabulary
Pegasus Lectures, Inc. Volume II Companion Presentation Frank Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
A new Ultrasound modality: US Elastography
Ultrasonic Nonlinear Imaging- Tissue Harmonic Imaging.
Introduction Theory Methods Experiments Results Application Summary Dr. Heiko Maaß Institut für Angewandte Informatik Noninvasive Measurement of Elastic.
Ultrasound Medical Imaging Imaging Science Fundamentals.
Information Technology for the Health Professions, 2/e By Lillian Burke and Barbara Weill ©2005 Pearson Education, Inc. Pearson Prentice Hall Upper Saddle.
Dept. Elect. Eng. Technion – Israel Institute of Technology Ultrasound Image Denoising by Spatially Varying Frequency Compounding Yael Erez, Yoav Y. Schechner,
BGA 2007 Different aspects of seismic amplitude decay in viscous magma Patrick Smith Supervisor: Jürgen Neuberg School of Earth and Environment, The University.
Low frequency coda decay: separating the different components of amplitude loss. Patrick Smith Supervisor: Jürgen Neuberg School of Earth and Environment,
Ultrasound Imaging Atam Dhawan.
K L University 1 By G.SUNITA DEPARTMENT OF PHYSICS.
MAGENETIC RESONANCE IMAGINING T2, T5, T7.
Ultrasound Spring 2009 Student Final. Ultrasound AKA: 1)Diagnostic Medical Sonography 2)Sonography3) 4) Vascular Sonography 5)Echocardiography.
GENERATING AND DETECTING OF ULTRASOUND
Ultrasound – Physics & Advances
Introduction of Medical Imaging Chun Yuan. Organization of the Course 8 Lectures (1.5 hours per lecture) – Introduction of medical imaging and MRI – Basic.
Positron Emission Tomography
 Second most prevalent cancer worldwide 3  Fifth most common cause of cancer related death 4  Early diagnosis is a huge factor in survival.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
3/13/2009IB Physics HL 21 Ultrasound Medical Imaging Physics – IB Objectives I.2.7Describe the principles of the generation and the detection of ultrasound.
Ultrasound measurements on tissue Penny Probert Smith Institute of Biomedical Engineering Department of Engineering Science University of Oxford (also.
1 RADIATION FORCE, SHEAR WAVES, AND MEDICAL ULTRASOUND L. A. Ostrovsky Zel Technologies, Boulder, Colorado, USA, and Institute of Applied Physics, Nizhny.
1 Ultrasonic Elasticity Imaging. 2 Elasticity Imaging Image contrast is based on tissue elasticity (typically Young’s modulus or shear modulus).
TAPPINGMODE™ IMAGING APPLICATIONS AND TECHNOLOGY
Building Three-Dimensional Images Using a Time-Reversal Chaotic Cavity
1 ME 660 Intermediate Acoustics Joe Vignola Office: Pangborn G43 Phone: Cell: Class Location:Building.
The effect of visco-elasticity on the stability of inertial cavitation D. Sinden, E. Stride & N. Saffari Department of Mechanical Engineering, University.
DIAGNOSTIC SERVICES What They Do * Perform tests or evaluations that aid in the detection, diagnosis, and treatment of disease, injury or other physical.
Excitation of Vibrational Eigenstates of Coupled Microcantilevers Using Ultrasound Radiation Force ASME 2nd International Conference on Micro and Nanosystems.
Review of Ultrasonic Imaging
Physics 1C Lecture 14B Today: End of Chapter 14 Start of Chapter 24.
STEPPER MOTORS Name: Mr.R.Anandaraj Designation: Associate. Professor Department: Electrical and Electronics Engineering Subject code :EC 6252 Year: II.
4-Jun-161 ULTRASOUND IMAGING Lec 1: Introduction Ultrasonic Field Wave fundamentals. Intensity, power and radiation pressure.
Digital Radiology Techniques used in imaging. Why is technology so important? Prenatal Diagnosis and Management of Conjoined Fetuses.
Digital Beamforming. Beamforming Manipulation of transmit and receive apertures. Trade-off performance/cost to achieve: –Steer and focus the transmit.
1/20 Joyce McLaughlin Rensselaer Polytechnic Institute Interior Elastodynamics Inverse Problems I: Basic Properties IPAM – September 9, 2003.
Psychology Mr. Duez Unit 2 - Biological Bases of Behavior Brain Scans.
Chapters 16, 17 Waves.
Numerical Simulations of Laser-Tissue Interactions Shannon M. Mandel Sophomore Intense Laser Physics Theory Unit Illinois State University Supervisor.
Lecture 13  Last Week Summary  Sampled Systems  Image Degradation and The Need To Improve Image Quality  Signal vs. Noise  Image Filters  Image Reconstruction.
Estimation of Point Spread Function (PSF) in Ultrasound Imaging Clara M Mosquera Lopez.
AP PSYCHOLOGY: UNIT II Introductory Psychology: Biological Bases of Behavior Topic: Research Methods.
EE Audio Signals and Systems Wave Basics Kevin D. Donohue Electrical and Computer Engineering University of Kentucky.
TISSUE HARMONIC IMAGING (THI)
TISSUE HARMONIC IMAGING (THI)
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
TISSUE HARMONIC IMAGING NUR FASHIHA BINTI AZMAN A DIAGNOSTIC IMAGING AND RADIOTHRAPY /2.
EKT 451 CHAPTER 6 Sensor & Transducers.
NUR INANI BINTI MOHD RUZLAN A Tissue harmonic imaging is a technique in ultrasonography that provides images of better quality as compared to conventional.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Date of download: 7/8/2016 Copyright © ASME. All rights reserved. From: Measurement of the Dynamic Shear Modulus of Mouse Brain Tissue In Vivo by Magnetic.
Bou-Cabo Manuel Ardid-Ramírez Miguel Camarena-Femenía Francisco Espinosa-ResolloVíctor Larosa Giuseppina Martínez-Mora Juan A (IGIC- Universitat Politècnica.
Bou-Cabo Manuel Ardid-Ramírez Miguel Camarena-Femenía Francisco Espinosa-ResolloVíctor Larosa Giuseppina Martínez-Mora Juan A (IGIC- Universitat Politècnica.
[1] Ophir, Jonathan, et al. "Elastography: a quantitative method for imaging the elasticity of biological tissues." Ultrasonic imaging (1991) [2] Muthupillai,
Instrumentation & Measurement
Numerical Simulations of Laser-Tissue Interactions
LNF Seminar’ Frascati, Italy
BioSignal Processing.
Review of Ultrasonic Imaging
MR Elastography John B. Weaver
Waves Wave- a disturbance that transfers energy through matter or space. - particles of matter don’t move along with wave. Medium- substance or region.
Electroencephalogram (EEG)
Ultrasonic Imaging Using Contrast Agents
Presentation transcript:

Harmonic Deconvolution in Ultrasound Vibro-Acoustic images Alexia Giannoula Communications group, Dept of Electrical & Computer Engineering, University of Toronto

Elastography  Changes in elastic properties of soft tissue have been often attributed to the presence of disease or abnormal structures  Most techniques in elasticity imaging or elastography involve: » tissue excitation by an external or internal force » detection of the tissue motion or displacement Using Ultrasound, magnetic resonance (MR), acoustic/optical methods Hard inclusion/tumor: smaller displacement B-modeelastogram

Acoustic Radiation Force  A way to excite directly a target inside the body is through the use of the radiation force of ultrasound  Advantages: » Non-invasive (external) excitation » Highly-localized radiation stress field (leads to increased precision)  The radiation force mainly depends on: » The type of propagating medium (lossless/lossy, viscoelastic fluid etc.) » Mechanical properties of the target object » Geometry of the target object

Ultrasound Vibro-Acoustography (USVA) 1.Two CW beams at slightly different frequencies interfere in the focal zone 2.A modulated ultrasound field is generated at the “beat” frequency Df (low) 3.A highly-localized dynamic (oscillating) radiation force is produced 4.In response to the force (stress field), the object vibrates at the same Df 5.Vibration  acoustic emission  Detected by hydrophone/laser vibrometer Detection sensitivity: few nanometers Image resolution: PSF~700μm USVAX-RayPhoto

Proposed Deconvolution Scheme (I)  Usually a blur is observed around the object » Due to the sidelobe effects of the system PSF  Apply separate deconvolution to the fundamental and second harmonic signals recorded by the hydrophone  Higher-harmonics arise due to tissue nonlinearities » Harmonic imaging  better resolution and less noise/blur Second harmonic Fundamental

Proposed Deconvolution Scheme (II)  First and Second-harmonic image formation: ? ξ(r 1 ) object function Each PSF h i represents the response of a point target to the radiation force F i (i=1,2) Obtain 2 deblurred images ξ 1, ξ 2 Fuse the outputs based on the different attenuations: ξ = α 1 ξ 1 + α 2 ξ 2 Form h 1, h 2 Filter each χ 1 (r), χ 2 (r) with the inverse PSFsFind F 1, F 2