Multi-colour sctintillator-based ion beam profiler James Green, Oliver Ettlinger, David Neely (CLF / STFC) 2 nd Ion diagnostic workshop June 7-8 th.

Slides:



Advertisements
Similar presentations
Scintillator-based online detectors for laser-accelerated protons –
Advertisements

J. Pozimski-FETS IC 10 May 2006 First experiences with the FETS pepperpot detector.
Extending the Dynamic Range of Radiochromic Film Oliver Ettlinger Ion Instrumentation Workshop, LULI
Design and Experimental Considerations for Multi-stage Laser Driven Particle Accelerator at 1μm Driving Wavelength Y.Y. Lin( 林元堯), A.C. Chiang (蔣安忠), Y.C.
Digital Radiography.
SoLID EC Design for IHEP 2012/10. Basic Features of Preliminary Design Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm.
Ultrafast XUV Coherent Diffractive Imaging Xunyou GE, CEA Saclay Director : Hamed Merdji.
Alexander Klyachko, IU Cyclotron, PTCOG51, Seoul, South Korea, May 17-19, 2012 A.V. Klyachko 1, D.F. Nichiporov 1, L. Coutinho 2, C.-W. Cheng 2, 3, M.
Fluorescence microscopy – Principle and practical consideration Hiro Ohkura.
Scint. Al Internal reflection External reflection ↑ ↑ ↑ Decay Detector Development for Giant Resonance Studies By: Gus Olson Mentor: Dr. D.H.Youngblood.
Richard M. Bionta XTOD July 19-21, 2005 UCRL-PRES-xxxxxx X Ray Diagnostics LCLS FAC Meeting Oct. 27, 2005.
Optical Diagnostics Thomas Tsang tight environment high radiation area non-serviceable area passive components optics only, no active electronics back.
FLASH Experiments with Photons High intensity laser light in the VUV spectral region Harald Redlin; HASYLAB.
Update on LLNL FI activities on the Titan Laser A.J.Mackinnon Feb 28, 2007 Fusion Science Center Meeting Chicago.
Richard M. Bionta XTOD Layout and Diagnostic October 12-13, 2004 UCRL-PRES-XXXXX XTOD Layout and Diagnostic Systems Facility Advisory.
Two-dimensional and wide dynamic range profile monitor using OTR/fluorescence screens for diagnosing beam halo of intense proton beam Y. Hashimoto, T.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
R. M. Bionta SLAC November 14, 2005 UCRL-PRES-XXXXXX LCLS Beam-Based Undulator K Measurements Workshop Use of FEL Off-Axis Zone Plate.
Digital Technology 14.2 Data capture; Digital imaging using charge-coupled devices (CCDs)
Fiber Mesh Diagnostic (FMD) for Transverse profile measurements Project Status Report April 26, 2012 BNL ATF Users Meeting G. Andonian, R. Agustsson, A.
1 Fluorescence Cameras -Dr James Milnes -Live Cell Imaging – Stem Cell Research -Portland Place, London, 24 June 2009 Live Cell Imaging.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
Measurements with the KSTAR Beam Emission Spectroscopy diagnostic system Máté Lampert Wigner Research Centre for Physics Hungarian Academy of Sciences.
Xiaodong Wang ( 王晓冬 ) School of Nuclear Science and Technology Lanzhou University, Lanzhou, China MPGD activities at Lanzhou University July 5, 2013.
INTRODUCTION : Imaging antiprotons INTRODUCTION : Imaging antiprotons First results of real time imaging of the high energy gamma rays coming from antiproton.
HITRAP-Meeting at GSI, Sept., 22 nd, 2005 C.Gabor, O.Meusel, J.Pozimski, H.Klein, U.Ratzinger Measurements with a Detector System for Low Energy Hydrogen.
Angular distribution of fast electrons and
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
S Optical CT scanning of PRESAGE TM polyurethane samples with a CCD-based readout system S J Doran 1*, N Krstajic 1, J Adamovics 2 and P M Jenneson 1 1.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Munich-Centre for Advanced Photonics A pixel detector system for laser-accelerated ion detection Sabine Reinhardt Fakultät für Physik, Ludwig-Maximilians-Universität.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
AIR CORE SCINTILLATION DOSIMETER SUMMARY We have shown that Cerenkov light can be reduced to a negligible level in scintillation dosimetry by using an.
Supported by Imaging the Pedestal Island Structure during the Application of 3D Magnetic Perturbations Office of Science D.J. Battaglia 1*, M.W. Shafer.
Fast Electron Temperature Scaling and Conversion Efficiency Measurements using a Bremsstrahlung Spectrometer Brad Westover US-Japan Workshop San Diego,
Status Report of the LISOL Laser Ion Source Yu.Kudryavtsev, T.Cocolios, M.Facina, J.Gentens, M.Huyse, O.Ivanov, D.Pauwels, M.Sawicka, P.Van den Bergh,
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
Implantation of heavy ions 86 Kr and 132 Xe in emulsion with energy 1.2 A MeV K.Z. MAMATKULOV LHEP, JINR, Dubna, Russia. DjPI, Uzbekistan. “Workshop on.
G. Ferioli, R. Jung - LHC-BI Review Workshop November 19&20 LHC Screen Profile Monitors G. Ferioli, R. Jung Introduction BTV LHC layout Monitor set-up.
Matching monitors for SPS and LHC E. Bravin 31 March 2011.
Beam Halo Monitoring using Optical Diagnostics Hao Zhang University of Maryland/University of Liverpool/Cockcroft Institute.
Active Pixel Sensors in Medical and Biologi The application of Large Area Active Pixel Sensor (LAS) to high resolution Nuclear Medicine imaging Bob Ott.
Neutron Imaging for the Hydrogen Economy Neutrons see material differently than x-rays The fine details of the water in this Asiatic Lily are clear to.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Switching with Ultrafast Magnetic Field Pulses Ioan Tudosa.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Gamma Detector of Plastic Scintillator Oct. 2, 2009 IP-BSM Group 1.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
1 Radiation Environment at Final Optics of HAPL Mohamed Sawan Fusion Technology Institute University of Wisconsin, Madison, WI HAPL Meeting ORNL March.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
g beam test of the Liquid Xe calorimeter for the MEG experiment
Solid-State Cameras for LHC instrumentation
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Instrumentation for Accelerators Technologies for the HL-LHC
Detector development for
Syedah Sadaf Zehra DCU and UNIPD Supervisors
Single-shot visualization of EVOLVING, light-speed index structures by multi-object phase contrast imaging Zhengyan Li, Rafal Zgadzaj, Xiaoming Wang, Chih-Hao.
Diagnostics of FRIBs beam transport line
Neutron imager with Micro Channel Plates (MCP) in electrostatic mirror configuration: first experimental test V. Variale*, B. Skarbo2 1Istituto Nazionale.
Enrica Chiadroni LNF-INFN 20 aprile 2010
HE Calorimeter Upgrade Studies
CMS ECAL Calibration and Test Beam Results
Extreme Ultraviolet Radiation Spectrometer Design and Optimization
Detector development for
Optical Diagnostics tight environment high radiation area
Profile measurements at CTF
Dual readout calorimeter for CepC
Presentation transcript:

Multi-colour sctintillator-based ion beam profiler James Green, Oliver Ettlinger, David Neely (CLF / STFC) 2 nd Ion diagnostic workshop June 7-8 th

Talk outline Diagnostic outline Multi-channel characterisation Reducing EMP & radiation effects Demonstration on Astra Gemini Future developments

High-repetition rate advances Passive media (CR-39, RCF, Image plate) increasing unsuitable Transition to active diagnostics: Scintillators, Micro-channel plates (MCPs), Phosphor screens Target Laser CCD Fibre bundle Scintillators Lens Ion beam Micro-channel plates (MCP) Radiochromic film (RCF)

2D detector head development Diagnostic aims: – 2D beam profiling – Spectral measurement – Beam pointing – Calorimetry Compact scintillator beam head – Scintillator thickness determines energy observation window – Each scintillator has a separate central emission wavelength – Need to avoid optical excitation within scintillator stack Scintillator 3 (Blue) Scintillator 1 (Orange Scintillator 2 (Green) Incident Protons 100 mm 90 mm Detector head Proton stopping ranges

Optical Stimulation Optical Stimulation: – Emission from Blue or Green scintillators can optically stimulate emission from scintillators earlier in the stack – How to stop light travelling back through the system? 5 Scintillator 3 (Blue) Scintillator 1 (Orange Scintillator 2 (Green) Incident Protons

Reducing EMP / radiation impact High resolution 800 x 800 fibre bundles – Image relay from Phosphor / Scintillator to camera outside interaction chamber – Durable with flexible deployment options – Wide transmission range – Long fibre lengths (> 5 m) possible Eliminating background radiation – Gated CCDs to block X-ray / electron signal – CCD safely shielded from hard hits 60um CoreCore Optical Cladding Optical Core Groups of fibres inside bundle

Channel separation Signal split in front of camera into 4 channels, RGB + Extra Dichroic filters used to isolate each scintillator signal RedGreen BlueAll channels Data obtained using from SRIM –

Data Deconvolution System characterised using a Cyclotron proton source Produced a response matrix for each colour channel 8 Predicted Response Matrix -Ideally require 1 on the diagonal, with 0 everywhere else

Astra Gemini experiment Astra Gemini – – 12J 50fs – 5x10 20 Wcm -2 – >10 10 contrast – TCC – Scintillator = 20 cm Scintillator 3 (Blue) Scintillator 1 (Orange Scintillator 2 (Green) Incident Protons MeV 7-9 MeV MeV Laser

Astra Gemini experiment MeV7-9 MeV MeV 50 nm Al Shot a range of Al foils, nm Clear signals on orange and green channels, insufficient flux for blue Clear structure visible with peak off axis for some shots FOV = 30 o 100 nm Al

Imaging novel targetry Microspoke targets shot on Astra Gemini Proton beam imaged using RCF and Scintillator stack 11 1mm Disks: 32um diameter, 40nm thick SiN membranes Supporting wires: 1µm wide, 40 nm thick Hole etched through 400μm thick Si. Scintillator RCF

10 Hz operation Scintillator considerations: – Rapid (  s) recovery between shots – Minimising high dose damage Implement new Scientific CMOS camera – 30 fps continuous full-frame operation – Low noise read-out, 16-bit Dynamic range Data analysis – Real-time data deconvolution for live beam profiles (Desirable – looking for collaborators?)

Future developments Further diagnostic testing – 0.05 Hz to 10 Hz progression – Efficient data capture and analysis Scintillator development – Thin scintillators for high spectral resolution – Calibration at higher (> 30 MeV energies) – Faster scintillators for fast gating – Media lifetime Experimental & industrial collaborations – Experimental access on range of facilities – Next-gen imaging and scintillator technology