Dirk Audring DE Academic Village Barcelona 12-15 May 2003 1 Supplying micro-grids with stationary fuel cell systems Prof. Dr.-Ing. G. Balzer, Dipl.-Ing.

Slides:



Advertisements
Similar presentations
Field tests in the Ílhavo Municipal Swimming-Pool on transfer between grid connected and islanding modes Results: Field tests demonstrated the feasibility.
Advertisements

Understanding Electrical TransmissionDemonstration D1 A Guide to the National Grid Transmission Model Demonstration D1 Power losses in transmission.
Modeling of Reconnection of Decentralized Power Energy Sources Using EMTP ATP Ing. Dušan MEDVEĎ, PhD. Železná Ruda-Špičák, 25. May 2010 TECHNICAL UNIVERSITY.
Understanding Electrical TransmissionDemonstration C2 A Guide to the National Grid Transmission Model Demonstration C2 Why are high voltages used for transmission?
ECE Electric Drives Topic 6: Voltage-Fed Converters Spring 2004.
Understanding Electrical TransmissionDemonstration A1 A Guide to the National Grid Transmission Model Demonstration A1 How is electricity generated and.
ECE 4411 Dynamic Braking of Induction Motors Slow down a machine by converting kinetic energy stored in the rotating mass to heat energy in the rotor and/or.
Transformer SONNY P. DE LEON MT 1.
1 Lab #7 – Thevenin/Norton Activity #1 – finding the Thevenin/Norton Equivalent for the function generator –The function generator is a voltage source.
EE4503 Electrical Systems Design
PWM (Pulse Width Modulation)
Two Phase Control. Depending on their design, soft starters control one, two or three phases. The CSX controls only two phases because this allows the.
AC MOTOR INDUCTION MOTOR.
Mehran University Of Engineering & Technology, SZAB Khairpur Mirs Campus ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR.
Motor Start Theory ME00107A.
Overcurrent Protection and Voltage Sag Coordination in Systems with Distributed Generation J. Carlos Gomez 1 M. M. Morcos 2 1 Rio Cuarto National University,
XX - 1 Control of the SuperGrid Crowne Plaza Cabana Palo Alto Hotel Palo Alto, California, November 6-8, 2002 Bob Lasseter University of Wisconsin-Madison.
Electrical Installation 2
D. De Venuto,Politecnico di Bari 0 The CMOS common-gate amplifier: (a) circuit; (b) small-signal equivalent circuit; and (c) simplified version of the.
Barcelona– May 2003 CIRED’2003 Beta session 4a: Distributed Generation Controllability of DG helps managing Distribution Grids J. A. Peças Lopes
© Imperial College LondonPage 1 A Review and Proposal on Controller Design for a DC/AC Power Converter Xinxin Wang Control and Power Group.
Institute of Power Electronics 1 Comparison of Series Hybrid Active Power Filters in Medium Power Application Comparison of Series Hybrid Active.
Assumption University Thailand EE4503 Electrical Systems Design Main Circuit 1.
EE2010 Fundamentals of Electric Circuits Lecture 11 Network Theorems: Norton’s Theorem.
14/06/2004NORPIE Paralleling of 3-phase inverters a part of my PhD study: "Control and monitoring for distributed power supply“ which is a part of.
Manjula Dewadasa Arindam Ghosh Gerard Ledwich
Short circuiting a battery demo… Dangerous ? High current?
Clemson University Electric Power Research Association CHANDANA BOMMAREDDY CLEMSON UNIVERSITY DG VOLTAGE CONTROL IN AN ISLANDING MODE OF OPERATION.
Tchuidjan Roger, PhD Electrical Engineer 1 Connection of disturbing loads in micro-grids National Advanced Polytechnique Institute of Yaounde - Cameroon.
Space Vector Pulse Width Modulation Space Vector Pulse Width Modulation Space Vector Pulse Width Modulation Space Vector Pulse Width Modulation Dr. Pedro.
Frankfurt (Germany), 6-9 June 2011 Louise Jakobsen, Danish Energy Association – Denmark – Session 3 – Paper 0811 Louise Jakobsen, Danish Energy Association.
Analysis of a 1.7 MVA Doubly Fed Wind-Power Induction Generator during Power Systems Disturbances Slavomir Seman, Sami Kanerva, Antero Arkkio Laboratory.
Cocchiara IT Session 1 – Block 1 – Question 3-1 Barcelona May INVERTER OVER-CURRENT LIMIT OPERATION Output voltage reduction Output current.
CCU Department of Electrical Engineering National Chung Cheng University, Taiwan 風力發電期末報告 Short-Circuit Current of Wind Turbines With Doubly Fed Induction.
Grid connection of distributed generation
Elec467 Power Machines & Transformers Electric Machines by Hubert, Chapter 12 Topic: Self-excited and compound generators, load distribution.
S. MELQUIOND France Session 1 – Block 1 – Question 1- 5 Barcelona May Question 1-5 Is the transformer protection by mean of protection switch.
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
TECHNICAL PAPER ON SIMULTANEOUS AC-DC POWER TRANSMISSION
Techniques of Circuit Analysis
Abbott Technologies Presents DC To AC Inverters. DC To AC Power Inverters change direct current (DC) to Alternating current (AC).
A NOVEL CONTROL STRATEGY FOR HYBRID AC/DC MICRO GRID SYSTEMS
Electromechanical Relays Mechatronics ECE 5320 Assignment #1 Paul Smart.
Converter Fed Microgrids : Challenges & Solutions Presenter: Charles Sao, PhD Candidate, ECE Dept., U. of Toronto Contact Info:
ELECTROTECHNIC. LARGE RANGE OF ROTARY MACHINES AND ACCESSORIES Educational equipment & solutions for technical training institutes & Universities 90W.
Power Electronics and Control in Wind Energy Conversion Systems
Eric A Lewis Enstore director
Unit – IV Starting and Speed control of Three phase Induction motor
Electricity is produced at the power station.
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
iuyoiuyiouy Erik Hoff, Tore Skjellnes, prof. Lars Norum
Control Schemes for Distribution Grids with Mass Distributed Generation AUTHOR: UMAIR SHAHZAD.
D. Menniti, N. Sorrentino, A. Pinnarelli, M. Motta, A. Burgio and P
Three-Phase AC machines
Wen Cai Supervisor: Dr. Babak Fahimi December 04, 2015
AC Voltage Controllers AC to ac Converters
Optimization of the Energy-Supply-Structure of modern Aircraft by using conventional power system technologies Dipl.-Ing. Ilir Purellku Electrical Power.
Inverters Converting dc to ac
Interconnection of AES With The Grid
AC Voltage Controllers AC to ac Converters
Ahmed Kulab Moh. Abed Foaad Al-Habeel
THREE-PHASE INVERTERS
Electricity Review.
Electricity Review.
Components inverters Except where otherwise noted these materials are licensed Creative Commons Attribution 4.0 (CC BY)
Power Conditioners and Uninterruptible Power Supplies
Inverters Converting dc to ac
Example Example 1: An electric lamp is rated 110 W, 200 V. When the lamp is operated at its rated power and voltage, calculate a) the current flowing through.
DIPLOMA In ELECTRICAL ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING GOVERNMENT POLYTECHNIC COLLEGE, HANUMANGARH Sept A Training Presentation On.
Electric Machine Design Course
Presentation transcript:

Dirk Audring DE Academic Village Barcelona May Supplying micro-grids with stationary fuel cell systems Prof. Dr.-Ing. G. Balzer, Dipl.-Ing. D. Audring Darmstadt University of Technology Department of Electrical Power Systems

Dirk Audring DE Academic Village Barcelona May Structure Examined micro-grid Short-circuit performance Disconnection from power system Conclusions

Dirk Audring DE Academic Village Barcelona May Examined micro-grid Micro-grid is supplied by one fuel cell Fuel cell sets voltage and frequency of micro-grid Induction motor and two loads are connected to micro grid Network connection is simulated for back-up power supply using a disconnecting switch

Dirk Audring DE Academic Village Barcelona May Short-circuit performance Fuel cell acts as a voltage source with limited current output This leads to low short- circuit current at micro- grid Selectivity with over- current protection is difficult to achieve

Dirk Audring DE Academic Village Barcelona May Short-circuit performance Short-circuit currents are limited by inverter Transformation ratio and vector group of inverter- transformer influences short-circuits at micro-grid

Dirk Audring DE Academic Village Barcelona May Short-circuit performance

Dirk Audring DE Academic Village Barcelona May Disconnection from power system Short-circuit at power system leads to voltage drop at connected micro-grid Induction motor slows down Induction motor must be re- accelerated after disconnection from network Power quality is poor during disconnection and not acceptable for PC etc.

Dirk Audring DE Academic Village Barcelona May Conclusions Main characteristic of micro-grid supplied by fuel cell is low short-circuit current Selectivity with over-current protection is difficult to achieve Transformation ratio and vector group of inverter-transformer is to consider for calculation of short-circuit currents at micro-grid Disconnection from power system due to short-circuit has to carried out fast to reduce voltage disturbances at micro-grid