5 MeV Mott Polarimeter Progress Riad Suleiman April 10, 2012.

Slides:



Advertisements
Similar presentations
Lumi Analysis for HAPPEx III / PREX Presented by: Luis Mercado UMass - Amherst 5/18/2007.
Advertisements

5 MeV Mott Measurement for CEBAF Operations group Joe Grames, Marcy Stutzman February 14 th, 2007 Sir Nevill F. Mott at the ceremony with his Nobel Prize.
Beam test of the microscope prototype and active collimator preliminary report on the parasitic beam tests in Hall B April 2011 Richard Jones, Igor Senderovich,
Parity Quality Beam (PQB) April 07, Notes: 1.For each BPM, the wires are: +X+, +X-, +Y+, +Y- 2.There are only two injector BPMs we are not reading:
1 Analysis of TOF data Yordan Karadzhov St.Kliment Ohridski University of Sofia.
Commissioning of a Nebraska-type Retarding Potential Mott Polarimeter J. McCarter, M. L. Stutzman, T. J. Gay, K. Trantham, P. Adderley, J. Brittian, J.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
N_TOF fission data of interest for ADS
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
Precision Test of Mott Polarimetry in the MeV Energy Range P.A. Adderley 1, T. Gay 2, J. Grames 1, J. Hansknecht 1, C. Horowitz 3, M.J. McHugh 4, A.K.
PN12 Workshop JLab, Nov 2004 R. Michaels Jefferson Lab Parity Violating Neutron Densities Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons.
Electronic Cross-talk & Ground Loop Elimination in Injector Riad Suleiman Center for Injectors and Sources.
Mott DAQ Speed December 18, How to speedup DAQ I.Reject low-energy electrons before reaching DAQ: 1.Increase E-detector hardware threshold 2.Vetoing.
AESOP: Accurate Electron Spin Optical Polarimeter Marcy L. Stutzman, Matt Poelker; Jefferson Lab Timothy J. Gay; University of Nebraska.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
DIS 2006 TSUKUBA April 21, 2006 Alessandro Bravar Spin Dependence in Polarized Elastic Scattering in the CNI Region A. Bravar, I. Alekseev, G. Bunce, S.
Polarized Source Development Run Results Riad Suleiman Injector Group November 18, 2008.
Real-time Parity Feedback John Hansknecht & Riad Suleiman April 28, 2009.
DAQ Map of Electronic Components L. Adeyemi, A. Camsonne, E. Fanchini, JS. Real, R. Suleiman, E. Voutier May 24, 2012.
A scintillation detector for neutrons below 1 MeV with gamma-ray rejection Scintillators are 3 mm BC408, 10 layers total Adjacent layers are optically.
Polarimetry of Proton Beams at RHIC A.Bazilevsky Summer Students Lectures June 17, 2010.
Diana Parno – July 22, 2008 January PREx Test Run: Compton Photon Analysis Diana Parno Carnegie Mellon University HAPPEX Collaboration Meeting.
Parity Quality Beam (PQB) Study Injector Group November 10, 2008.
Run Coordinator Weekly Report EG6 Commissioning October Raffaella De Vita.
A study of systematic uncertainties of Compton e-detector at JLab, Hall C and its cross calibration against Moller polarimeter APS April Meeting 2014 Amrendra.
1 Polarimeter for dEDM experiment G. Venanzoni Laboratori Nazionali di Frascati for the dEDM collaboration Workshop on Flavour in the era of LHC – Cern.
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
M. Dugger, February Triplet polarimeter study Michael Dugger* Arizona State University *Work at ASU is supported by the U.S. National Science Foundation.
Pb Electroweak Asymmetry in Elastic Electron-Nucleus Scattering : A measure of the neutron distribution PREX and CREX 48 Ca Neutron Skin Horowitz.
Neutron detection in LHe ( HMI run 2004) R.Golub, E. Korobkina, J. Zou M. Hayden, G. Archibold J. Boissevain, W.S.Wilburn C. Gould.
May 17, 2006Sebastian Baunack, PAVI06 The Parity Violation A4 Experiment at forward and backward angles Strange Form Factors The Mainz A4 Experiment Result.
Projected performance of NPDGamma and new systematics introduced by SM polarizer Christopher Crawford University of Kentucky NPDGamma Collaboration Meeting.
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Proton Charge Form Factor Measurement E. Cisbani INFN Rome – Sanità Group and Italian National Institute of Health 113/Oct/2011E. Cisbani / Proton FF.
DAQ Map of Electronic Components R. Suleiman February 12,
June 7, 2004Karen Dow CODA at Bates BLAST Data Acquisition.
Diana Parno – 18 April 2009 Compton Photon Detector Upgrade Diana Parno 18 April 2009 HAPPEX Collaboration Meeting.
Jefferson Laboratory Hall A SuperBigBite Spectrometer Data Acquisition System Alexandre Camsonne APS DNP 2013 October 24 th 2013 Hall A Jefferson Laboratory.
GEp-III in Hall C Andrew Puckett, MIT On behalf of the Jefferson Lab Hall C GEp-III Collaboration April 15, 2008.
Run Time, Mott-Schwinger, Systematics, Run plan David Bowman NPDGamma Collaboration Meeting 10/15/2010.
Thomas Roser Snowmass 2001 June 30 - July 21, 2001 Proton Polarimetry Proton polarimeter reactions RHIC polarimeters.
Re-designing the Helicity Board Riad Suleiman Injector Group March 19, 2009.
Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on work from: France:POMME B. Bonin et al. Nucl. Inst.
Injector Status & Commissioning QWeak Collaboration Meeting May 24, 2010 P. Adderley, J. Clark, S. Covert, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman,
Beam Studies December 2014 Runs: 7821, 7822, and 7860 December 29, 2014.
DAQ Speed and Run2 Estimates April 3, Summary of FADC Development for Faster Performance NameReadoutTrigger ScalersScaler S1 (helicity gated), S2.
Parity Experiments and JLab Injector Riad Suleiman February 5, 2016.
Mott Electron Polarization Results Riad Suleiman July 10, 2013.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy The Department.
Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Thesis Committee Review Meeting 2003/12/4.
Understanding the 3 He Nuclei: Asymmetry Measurements in Quasi- Elastic Ge Jin University of Virginia For the E Collaboration.
Pb-Parity and Septum Update Presented by: Luis Mercado UMass - Amherst 12/05/2008 Thanks to Robert Michaels, Kent Pachke, Krishna Kumar, Dustin McNulty.
DAQ and Trigger for HPS run Sergey Boyarinov JLAB July 11, Requirements and available test results 2. DAQ status 3. Trigger system status and upgrades.
 13 Readout Electronics A First Look 28-Jan-2004.
Polarized Injector & Upgrade Schedule QWeak Collaboration Meeting November 06, 2009 P. Adderley, J. Clark, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman,
Polarized Injector Update
"North American" Electronics
Mott Polarimeter at CEBAF
A First Look J. Pilcher 12-Mar-2004
Mott DAQ Speed February 16, 2015.
Sergey Abrahamyan Yerevan Physics Institute APEX collaboration
Parity Violation Experiments at JLEIC
Parity Quality Beam (PQB)
5 MeV Mott Measurement for CEBAF Operations group
QWeak Collaboration Meeting
A Precision Measurement of GEp/GMp with BLAST
Mott DAQ Timing R. Suleiman February 12, 2014.
Polarized Source Development Run Results
Recent results from BLAST detector
Presentation transcript:

5 MeV Mott Polarimeter Progress Riad Suleiman April 10, 2012

Outline Mott Scattering: Cross Section and Sherman Function Measuring Mott Asymmetry Mott Detectors Data Acquisition Analysis Charge Asymmetry 1% Polarization Measurement – Error Budget

Mott Scattering Electron motion in the electric field of nucleus results in magnetic field in electron rest frame,, if is nucleus-electron separation, then and Interaction of this magnetic field with electron (spin) magnetic moment introduces a term in the scattering potential, Presence of spin-orbit term in scattering potential introduces spin dependence in scattering cross section which could be detected as a left/right count rate asymmetry

Note: Parity-conserving: Measure spin-momentum correlation of the type: Transverse (or Normal) Beam Asymmetry measured recently using the setup of parity- violating experiments at high energies (due to two-photon exchange) probes the same spin-momentum correlation as Mott Asymmetry at low energies (due to spin-orbit interaction of electron moving in a Coulomb field). Parity-violating: Measure spin-momentum correlation of the type: V V r r L L L L V V r r L L L L

Mott Cross Section and Sherman Function Mott cross section: where, is the un-polarized cross section, and is the analyzing power (Sherman Function), The Sherman Function is largest for high-Z (Gold, Z=79) targets and low- energy electrons Non-spin-flip Amplitude Spin-flip Amplitude

Theoretical corrections to Sherman Function: I.Screening by atomic electrons which is relevant for low energy electrons II.Nuclear extended charge distribution which is relevant for high energy electrons

Mott Polarimeter Optimization Statistical error of polarization measurement is proportional to inverse of Figure of Merit (fom), The goal is to maximize fom The detector rate (R) is

Measuring Mott Asymmetry How to measure the Mott Asymmetry A LR ? –For one helicity state, measure the number of left and right E detector events, and –Flip the electron polarization, measure the number of events again, and –Calculate the cross-ratio (r), –Then, the Mott Asymmetry (A), The same for A UD This cancels false asymmetries from detector efficiency, beam current, target thickness, and solid angle Dead time is caused by slow DAQ and is common to all detectors – cancels to all orders

Statistical Uncertainty With the approximation, Error simplifies to or, Time needed to measure beam polarization of to statistical error of is

Sherman Function and Target Thickness Single-Atom Sherman Function must be corrected for plural scattering (a few large angle scattering) in the target: alpha = 0.3/um for 5 MeV electrons. Depends on electron energy and may depend on scattering angle Run with the thinnest target

Sherman Function Sensitivity to Energy and Angle

Three Targets (Z=29, 47,79)

I.Background I.Shielding and Collimation II.Coincidence, Time-of-flight Or … Subtract background: II.Target Thickness: o Single-Atom Sherman Function must be corrected for plural scattering (a few large angle scattering) in target: o S SA (0) = , S(1.0 μm) = o If possible, run with the thinnest target Corrections to Measured Asymmetry

5 MeV Mott Beamline

Detector Assembly I. Scattering Angle = 172.6° II. Solid Angle = 0.18 msr

New ΔE and E Detectors Installed - H7415 (R6427) 1" PMT - 1 mm x 1" x 1" EJ-212 Plastic Scintillator " x 1" x 2" Acrylic Light Guide - H6559 (R6091) 3" PMT - 3" diameter x 2.5" long EJ-200 Plastic Scintillator painted with EJ-510

ΔE and E Signals ΔE Detector E Detector

Old 5 MeV Mott DAQ - LeCroy CAMAC 4303 Time-to-FERA Converter (TFC) - LeCroy CAMAC 4300B Fast Encoding and Readout ADC (FERA), 10 Bit - ORTEC CAMAC HM 413 HISTO-MEMORY

Detectors Spectra - Beam Current = 0.5 μA - Gold Target 1.0 μm - Trigger Rate 1 kHz - 5 minutes of data

E Detectors Spectra

Mott Asymmetries - A UD = ± 0.36 % - A LR = ± 0.44 % - UD Instrumental (Detector Efficiency and Solid Angle) A1 = ± 0.40 % - LR Instrumental (Detector Efficiency and Solid Angle) A1 = ± 0.44 % - UD Instrumental (Beam Current and Target Thickness) A2 = 0.75 ± 0.41 % - LR Instrumental (Beam Current and Target Thickness) A2 = ± 0.44 %

New DAQ for Mott Polarimeter Will record the pulse shape and timing of detected electrons No dead time at rates <5 kHz, will be able to run at higher currents Can process delayed helicity reporting and measure time-of- flight of detected electrons Consists of: –CODA (CEBAF Online Data Acquisition) –Hardware: VME64x Backplane 6U Crate Motorola MVME6100 JLab Flash ADC: 16 channel, 12 bit, 250 MS/s SIS 3801 Scalers: Beam current and position CAEN V775 TDC: BFM

DAQ Schematic Diagram MVME6100 FADC Scalers TDC ∆E E E BFM Helicity Signals BPM BCM Helicity Signals

Detector Signals to fADC (Parasitic to old DAQ) E Detectors (50 ns) ΔE Detectors (50 ns) Data Trigger (50 ns) ADC GATE

Pair Sync Delayed Helicity T- Settle Pattern Sync Helicity Signals

FADC Chan Signal 0E LEFT 1E RIGHT 2E UP 3E DOWN 4ΔE LEFT 5ΔE RIGHT 6ΔE UP 7ΔE DOWN 8BFM 9 10Mott Trigger 11 12Delayed Helicity 13T_Settle 14Pattern-Sync 15Pair-Sync Mott Trigger Left E Left ∆E FADC Signals Signals on Scope Signals in FADC Data

Calculate pedestal and Energy: Few FADC Events in LEFT Detector

Energy Resolution=2.7% (same as old DAQ)

Pedestal Resolution Energy Resolution=2.4% (after Pedestal Correction)

Mott Asymmetry IHWPRun #P_VP_X OUT /- 1.1 (stat)0.6 +/- 1.2 (stat) IN /- 1.0 (stat)-3.4 +/- 1.1 (stat) OUT /- 1.1 (stat)2.4 +/- 1.2 (stat) IN /- 1.0 (stat)-3.0 +/- 1.0 (stat) AVERAGE85.7 +/- 0.5 (stat)2.4 +/- 0.6 (stat) IHWPFILEP_VP_X OUT16Feb12 08:30: /- 1.1 (stat)1.6 +/- 1.2 (stat) IN16Feb12 08:36: /- 1.1 (stat)-2.7 +/- 1.1 (stat) OUT16Feb12 08:54: /- 1.1 (stat)2.7 +/- 1.2 (stat) IN16Feb12 08:54: /- 1.1 (stat)-4.1 +/- 1.1 (stat) AVERAGE86.6 +/- 0.6 (stat)2.8 +/- 0.6 (stat) Data with Old DAQ Simultaneous Data with New DAQ Difference due to different energy cuts in analysis

BFM BFM after -140 mV offset BFM after -145 mV discrimination (TDC) BFM in FADC BFM Signal

Hall C 499 MHz Beam

499 MHz Beam Hall B and Hall C beams at 499 MHz

5 MeV Mott Beam-line Beam Dump 12 ns

31 MHz Beam Here, “E” is the peak of Energy signal (sample=74) Here, “E” is the peak of Energy signal (sample=74)

Mott Sweep Magnet at -5A

Mott Sweep Magnet at 0A

Mott Sweep Magnet at +5A

Spectra from Broken Gold Mott Target Mainly Dump Events

Mott Asymmetry vs. Energy Select events coming from target with a cut on TOF

Mott Asymmetry vs. TOF Asymmetry of Dump Event = 0 Asymmetry of Dump Event = 0 Asymmetry of Chamber Event = 0 Asymmetry of Chamber Event = 0

S1 ChanSignal 0BCM0L02 OUTPUT MHz Clock 2Mott Trigger BCM0L02 OUTPUT 3 13Delayed Helicity 14Battery 15 S1 Chan BPM Signal 160L01 X+ 170L01 X- 180L01 Y+ 190L01 Y- 200L02 X+ 210L02 X- 220L02 Y+ 230L02 Y- 245D00 X+ 255D00 X- 265D00 Y+ 275D00 Y- 285D01 X+ 295D01 X- 305D01 Y+ 315D01 Y- BPM 0L01 BPM 0L02 BPM 5D00 BPM 5D01 Scaler Readout

BCM0L02 Readout I.BCM0L02 Receiver output: 1.OUTPUT 2: 0.0 – 1.0 µA → 0 – 10 V II.Connected to VtoF (1 MHz, 10 V) III.Charge Asymmetry Test: o PITA (Polarization Induced Transport Asymmetry): charge asymmetry depends on Pockels Cell HV o Experiments use PITA to implement charge feedback o Measure PITA slope at PITA = -2000, 0, DAC (Nominal – about 2.9 kV on Pockels Cell). o Measure PITA Slope for beam currents: 1.0 µA, µA, µA, and µA

Charge Asymmetry Test  30 Hz  8-window Delay  Quartet

PITA Scan at 1.0 µA  Mott DAQ I.PITA Slope = ppm/DAC  QWeak DAQ I.PITA Slope = ppm/DAC

PITA at µA  Mott DAQ I.PITA Slope = ppm/DAC

PITA at µA  Mott DAQ I.PITA Slope = -1.1 ppm/DAC

PITA at µA  Overwhelmed by noise  Now, reliable charge asymmetry measurement to about 40 nA Next, … I.Calibrate Receiver to 100 nA FS II.Measure charge asymmetry at 10 nA III.For even lower beam currents: I.Measure charge asymmetry at 1 µA and at 10 nA → We know charge asymmetry at all currents

Precision Mott Electron Polarimeter Goal: Measure and publish electron polarization over range of 2 to 8 MeV with absolute uncertainty better than 1%. –Fast statistical measurements of experiment asymmetry (A) <0.5% vs. target thickness –Demonstrate instrumental false asymmetry <0.3% Eliminate background events with Time-of-Flight (ToF) cut Super-ratio calculation (double arm + helicity reversal) –New Data Acquisition system based on Hall D 250MHz FADC –Calculate the effective Sherman Function (S) < 0.8% Effective Sherman FunctionError (∆S/S) Nuclear Corrections0.5% Target Thickness Extrapolation0.6% Scattering angle (0.1°)0.1% Electron Energy (0.5%)0.1% Plan I.Theoretical support for Sherman function calculation II.Measurements are collected “for free” parasitic to PEPPo in May/June, 2012 III.GEANT4 Simulation – No Extrapolation