Presentation is loading. Please wait.

Presentation is loading. Please wait.

Mott Electron Polarization Results Riad Suleiman July 10, 2013.

Similar presentations


Presentation on theme: "Mott Electron Polarization Results Riad Suleiman July 10, 2013."— Presentation transcript:

1 Mott Electron Polarization Results Riad Suleiman July 10, 2013

2 Mott Scattering Electron motion in nucleus electric field results in magnetic field in electron rest frame,, if is nucleus-electron separation, then and Interaction of this magnetic field with electron (spin) magnetic moment introduces a term in the scattering potential, Presence of spin-orbit term in scattering potential introduces spin dependence in scattering cross section which could be detected as a left/right count rate asymmetry

3 Note: Parity-conserving: Measure spin-momentum correlation of the type: Transverse (or Normal) Beam Asymmetry measured recently using the setup of parity- violating experiments at high energies (due to two-photon exchange) probes the same spin-momentum correlation as Mott Asymmetry at low energies (due to spin-orbit interaction of electron moving in a Coulomb field). Parity-violating: Measure spin-momentum correlation of the type: V V r r L L L L V V r r L L L L

4 Mott Cross Section and Sherman Function Mott cross section: where, is the un-polarized cross section, and is the analyzing power (Single-Atom Sherman Function), Sherman Function is largest for high-Z (Gold, Z=79) targets and low-energy electrons Spin-flip Amplitude Non-spin-flip Amplitude

5 Theoretical Corrections Radiative corrections Screening by atomic electrons Finite nuclear size

6 Energy Sensitivity For T=5.0 MeV, p=5.5 MeV/c. However, momentum was measured to be p=5.336 ± 0.023 MeV/c, or T=4.850 MeV For δT/T=3%, δS/S(T=4.850)=0.09%

7 Sherman Function and Target Thickness Single-Atom Sherman Function must be corrected for plural scattering (a few large angle scattering) in the target: S SA (d=0, T=5.0 MeV) = -0.5215, S eff (d=1.0 μm, T=5.0) = -0.4006 Systematic Error (∆S/S) = 2.8% Effective Sherman FunctionError (∆S/S) Theoretical corrections2.0% Target thickness extrapolation2.0% Scattering angle (0.1°)0.1% Electron energy (1.0%)0.03%

8 Measuring Mott Asymmetry How to measure the Mott Asymmetry A LR ? –For one helicity state, measure the number of left and right detector events, and –Flip the electron polarization, measure the number of events again, and –Calculate the cross-ratio (r), –Then, the Mott Asymmetry: Same for A UD False Asymmetries: –Cancel to all orders: beam current, target thickness, solid angle, detector efficiency and dead time (due to slow DAQ common to all detectors) –Cancel to first order: differences in beam polarization between the two helicity states and misalignment errors resulting in detectors at different scattering angle

9 5 MeV Mott Beamline

10 Detector Assembly I. Scattering Angle = 172.6° II. Solid Angle = 0.18 msr

11 ΔE and E Detectors -H7415 (R6427) 1" PMT -1 mm x 1" x 1" EJ-212 Plastic Scintillator -0.125" x 1" x 2" Acrylic Light Guide -H6559 (R6091) 3" PMT -3" diameter x 2.5" long EJ-200 Plastic Scintillator painted with EJ-510

12 Old 5 MeV Mott DAQ LeCroy CAMAC 4300B Fast Encoding and Readout ADC (FERA), 10 Bit ORTEC CAMAC HM 413 HISTO-MEMORY

13 Detectors Spectra -Beam Current = 1.0 μA -Gold Target 1.0 μm -Trigger Rate 1 kHz -5 minutes of data

14 E Detectors Spectra

15 FADC Chan Signal 0E LEFT 1E RIGHT 2E UP 3E DOWN 4ΔE LEFT 5ΔE RIGHT 6ΔE UP 7ΔE DOWN 8BFM 9 10Mott Trigger 11 12Delayed Helicity 13T_Settle 14Pattern-Sync 15Pair-Sync Mott Trigger Left E Left ∆E New 5 MeV Mott DAQ Signals on Scope Signals in FADC Data

16 Calculate pedestal and Energy: Few FADC Events in LEFT Detector

17

18 Maximize Longitudinal Polarization on June 04, 2012  By adjusting INJTWF, P x and P y were minimized and beam polarization was measured:  After minimization, new nominal Injector Two-Wien-Flipper (INJTWF) settings during PEPPo data taking are: RunIHWPP x (%) ± StatP y (%) ± Stat 04Jun12 16:50:12OUT0.82 ± 0.92-1.22 ± 0.90 04Jun12 16:57:48IN0.45 ± 1.051.80 ± 1.02 04Jun12 17:03:38OUT0.42 ± 0.85-2.75 ± 0.85 04Jun12 17:11:00IN-0.15 ± 0.802.55 ± 0.80 Vertical Wien Angle+90.00˚ Solenoids Angle-91.45˚ Horizontal Wien Angle+86.70˚

19 Measure Longitudinal Polarization on June 10, 2012  Beam polarization was changed to horizontal transverse (P x ) with Horizontal Wien Angle changed from +86.70˚ to 0.00˚ RunIHWPP x (%) ± StatP y (%) ± Stat 6324OUT-82.96 ± 1.281.53 ± 1.28 6326IN84.03 ± 1.27-1.53 ± 1.27 6327IN85.20 ± 1.27-2.19 ± 1.28 6328OUT-84.76 ± 1.27-0.07 ± 1.28 6329IN83.45 ± 1.281.71 ± 1.28 6330OUT-84.09 ± 1.27-1.95 ± 1.28 6331IN84.16 ± 1.28-0.61 ± 1.28 6332OUT-84.54 ± 1.28-1.72 ± 1.28 6333IN82.06 ± 1.28-0.02 ± 1.28

20

21 Polarization Precession in 5 MeV Dipole P y is the same in Mott and Compton Polarimeters P x and P z polarization precession is: where a is electron anomalous magnetic moment, o Mott θ bend = -12.5˚ o Compton θ bend = +25.0˚ Mott, T = 5.0 MeV, θ spin = -0.16˚ Compton, p = 8.25 MeV/c, θ spin = +0.47˚ Total polarization precession, θ p = 0.63˚

22 Polarization at Compton Polarimeter At Mott: measurements on June 4 and June 10:  P x = -0.6% ± 0.6% (stat)  P y = 1.2% ± 0.4% (stat)  P z = 83.7% ± 0.6% (stat) At Compton: o cos(0.63˚) = 1.000 o sin(0.63˚) = 0.011  P x = 0.3% ± 0.6% (stat)  P y = 1.2% ± 0.4% (stat)  P z = 83.7% ± 0.6% (stat)

23 Summary  The electron beam polarization during PEPPo experiment is: P x = 0.3% ± 0.6% (stat) ± 2.8% (sys) P y = 1.2% ± 0.4% (stat) ± 2.8% (sys) P z = 83.7% ± 0.6% (stat) ± 2.8% (sys)  More work this Fall to reduce the systematic error I.New theoretical calculations II.New target thickness extrapolation


Download ppt "Mott Electron Polarization Results Riad Suleiman July 10, 2013."

Similar presentations


Ads by Google