Virtual experiments in University teaching Kim Lefmann MCNSI public, ISIS, 27/9-05.

Slides:



Advertisements
Similar presentations
Focusing monochromators/analyzers Asymmetric diffraction geometry of the monochromator Dispersive double crystal monochromator Two wavelength sandwich.
Advertisements

Five neutron experiments that advanced hard condensed matter Collin Broholm Johns Hopkins University.
McXtrace presentation, Sept McXtrace ray-tracing technology platform Peter Willendrup 1 Erik Knudsen 1 Andrea Prodi 2 Jana Baltser 2 Søren Schmidt.
Physics 102 Introduction Instructor Dr. Moza Al-Rabban Office Phone: Spring 2007.
Lecture 7 Light sources, filters, and monochromators Harris Ch.20.
Sample simulation. Basic Picture Complexity 1: Geometry.
SNS Experimental FacilitiesOak Ridge X /arb Neutron Instruments for Materials Research T.E. Mason Experimental Facilities Division Spallation Neutron.
HYSPEC Hybrid Spectrometer Instrument Development Team April, 2002 A High Performance Hybrid Spectrometer for the Single Crystal Studies at the Pulsed.
Managed by UT-Battelle for the Department of Energy Current and Future Instrument Development Projects at Oak Ridge Lee Robertson Instrument DevelopmentGroup.
HYSPEC Instrument: Status and Performance M. Hagen Neutron Facilities Development Division, SNS, Oak Ridge National Lab. W.J. Leonhardt and A. Ruga Condensed.
Farhi – ILL/DS/CS – slide 1 Separating coherent, incoherent and multiple scattering in virtual (and real) experiments Analysing experimental results using.
Polarized Beams Using He-3 at the NCNR Triple-Axis Spectrometers Ross Erwin Tom Gentile Wangchun Chen Sarah McKenney.
Progress on the New High Intensity Cold Neutron Spectrometer, MACS C. Broholm 1,2, T. D. Pike 1,2, P. K. Hundertmark 1,2, P. C. Brand 2, J. W. Lynn 2,
Conceptual Design: MACS is designed to maximize the efficiency for energy resolved surveys of Q-space in the sub-thermal energy range. Two innovations.
Neutron Diffraction Studies at the IBR2 Reactor Status and Future Geologisches Institut, Universität Freiburg, Albertstr. 23b, Freiburg, Germany.
1.
Circuit Construction Kit Projectile Motion Simulator.
HYSPEC HYSPEC INSTRUMENT DESIGN – OUTLINE  The two “models” considered for HYSPEC – inside & outside (Mark)  A breakdown of the components of the two.
HYSPEC Recent progress and polarization analysis capabilities ORNL: B. Winn, V. Ovidiu Garlea, M. Graves- Brook, Peter Jiang, X. (Tony) Tong BNL: L. Passell,
MACS –a New High Intensity Cold Neutron Spectrometer at NIST February 17, 2003Timothy D. Pike1 Developing MACS A Third Generation Cold Neutron Spectrometer.
Peter Willendrup, Kim Lefmann Introducing McStas 1.9 Introducing McStas McStas team (RISØ/ILL) Introducing McStas 1.9 Emmanuel Farhi, Klaus Lieutenant.
1 Introduction to McStas, Berlin MC school 2013 Introduction to McStas Peter Willendrup 1,5, Emmanuel Farhi 2, Erik Knudsen 1,5, Emmanouela Rantsiou 3,6,
Ken Andersen Instruments Division Head Science Directorate Fixing the Accelerator Time Structure ESS Science Advisory Committee Lund
On the way to neutron scattering at 40 T Report from this workshop Discussions with NSF/DOE/SNS Letter of Intent to SNS Conceptual design project proposal.
Choosing the Right Neutron Spectrometer Dan Neumann NIST Center for Neutron Research
1 New features in McStas - Berlin MC school 2013 New features in McStas Peter Willendrup 1,5, Emmanuel Farhi 2, Erik Knudsen 1,5, Emmanouela Rantsiou 3,6,
X-Ray Measurement Methods From Chapter 6 of Textbook 2 and other references Diffractometer Hull/Debye-Scherrer method Pinhole method Laue Method Rotating.
HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.
A simple introduction to Science at ISIS Robert McGreevy ISIS Facility, CCLRC Rutherford Appleton Laboratory, Chilton, Didcot, OX11 0QX, UK.
Polarized Neutrons in ANSTO – From LONGPOL to Pelican, Taipan, Sika, Platypus and Quake Dehong Yu and Shane Kennedy Bragg Institute, ANSTO, Australia.
MACS Concept and Project Status Making best use of CW source MACS-imizing incident flux MACS-imizing detection efficiency From concept to reality Collin.
Feb. 25 Th Erik Knudsen SMEXOS Erik Knudsen, Peter Willendrup, Søren Schmidt Risø-DTU Kim Lefmann, Andrea Prodi, Jana Baltser University of Copenhagen.
Status of JRA6 - MCNSI Kim Lefmann NMI3, ISIS, 28/9-05.
HYSPEC IDT Polarized Beam Operation of the Hybrid Spectrometer at the pulsed Spallation Neutron Source. Outline HYSPEC: project timeline and place in the.
The NCNR Spin-Polarized Triple-Axis Spectrometer (SPINS) The SPINS instrument is located at the heart of the cold neutron guide hall of the NIST Center.
Shielding Helium Cold neutron source Shutter Cooled filters Radial Collimators Variable Aperture Focusing monochromator on translation stage Focusing monochromator.
IConUSAS, Oak Ridge, 9-10 July 2003 SASProFit - program for USANS data evaluation Jan Šaroun Nuclear Physics Institute Řež, Czech Republic The program.
NCNR and NIST Neutron research and probing matter with cold neutrons OR Neutrons ignored no longer!
Parameters of the new diffractometer “ARES” Aleksey E. Sokolov PNPI NRC “KI”
ESS - SANS Instrumentation pulsed source SANS, using a wide range of wavelengths, uses more of the available flux than a continuous source. For same time.
Conceptual design and performance of high throughput cold spectrometer : MACS Why MACS Layout and key elements Performance Data collection Scientific program.
Past and Future Insights from Neutron Scattering Collin Broholm * Johns Hopkins University and NIST Center for Neutron Research  Virtues and Limitations.
Neutron Scattering Group February, 2001 A High Performance Instrument for the Single Crystal Spectroscopy at the Pulsed SNS. n What is the spectrometer.
NMI3 meeting, ISIS, September 26-29, 2005 Contents: Overview of new capabilities of the RESTRAX software Numerical optimizations of TAS parameters Virtual.
A New High Intensity Cold Neutron Spectrometer at NIST J. A. Rodriguez 1,3, P. Brand 3, C. Broholm 2,3, J.C. Cook 3, Z. Huang 3, P. Hundertmark 3, J. Lynn.
Efficiency correction of 2D-Large PSD by C language Jong-kyu Cheon Radiation Physics Lab.
1 Aims of this lecture The diatomic chain –final comments Next level of complexity: –quantisation – PHONONS –dispersion curves in three dimensions Measuring.
Peter Willendrup, Peter Christiansen, Kim Lefmann McStas release 1.9 and beyond McStas release 1.9 and beyond 1 McStas team (RISØ/ILL) McStas 1.9 release.
Parameters of the new diffractometer TEX Responsible: Yu.Kibalin, I.Golosovsky.
8:4. THE MASTER FORMULA OF NEUTRON SCATTERING 8:5. THE VARIOUS STRUCTURE FACTORS Chapter 8 - ELASTIC AND QUASIELASTIC/ INELASTIC NEUTRON SCATTERING.
Virtual experiments for teaching and training Kim Lefmann MCNSI, ILL, 26/5-05.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline BNL’s HYSPEC project and its place in the.
HYSPEC IDT HYSPEC: Our Instrument at the Spallation Neutron Source. Outline Spallation Neutron Source (SNS) and the BNL Overview of the SNS instrument.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline Polarization analysis and the HYSPEC place.
X-ray diffraction for today and tomorrow
Phase 1 Design for LOKI at ESS: performance evaluation of suitable detector technologies Or how to build detectors for ESS Kalliopi Kanaki Andrew Jackson.
October, 2001 Hybrid Spectrometer for Single Crystal Studies at the Pulsed SNS: an update. n Principal features of the proposed hybrid spectrometer. n.
A simple introduction to Science at ISIS
Peter Willendrup, Kim Lefmann
Ch.4 Atomic Structure of Solid Surfaces.
PHY 711 Classical Mechanics and Mathematical Methods
Very Cold Moderator Development at LENS
ECONOMICS: September 24 Warm-up Explain the difference between elastic demand and inelastic demand. Learning Target: In order to understand the concept.
Virtual Reality (VR) Introduction and Basic Applications
ECONOMICS: September 21 --conclude Demand enrichment activity (HO from yesterday) (TURN IN) -enrichment: if done additional practice (see screen)
DMSC services Stig Skelboe
PHY 711 Classical Mechanics and Mathematical Methods
ECONOMICS: February 7 Warm-up Why is it important for businesses to be aware of the D elasticity for the product they are selling? Conclude Ch. 4, Lesson.
IMAT: imaging + diffraction
Inelastic Neutron Scattering Correction
Presentation transcript:

Virtual experiments in University teaching Kim Lefmann MCNSI public, ISIS, 27/9-05

New University neutron course University of Copenhagen, 4 th year physics (+Ph.D.) 10 hours per week, 8 weeks Lecturers: Kim Lefmann, Peter Willendrup, Bente Lebech, Kell Mortensen Theory (Squires) and simple calculation problems Data analysis (Fullprof, Mfit) 3 reports on McStas simulations (DMC, RITA-2, SANS-2) Plus 3 (6) full days experiments at PSI One final report, no exam

Course plan (week by week) 1: Introduction (neutrons + McStas), materials, Squires ch : Scattering theory, (powder) diffraction, FULLPROF, DMC Project (crystal structure), Squires ch. 2-3 (elastic) 4-5: Inelastic scattering, phonons, MFIT, RITA-2 project (phonons), Squires ch. 2-3 (inelastic) 6-7: SANS, “SANS-software”, SANS-2 project, Notes 8: Magnetic scattering, Squires ch. 7-8 “9”: PSI experiments, (comparing with simulations)

PSI cold source Straight guide Flat monochromator Collimator Powder sample Banana detector (+ diagnostic monitors) Data analysis in FULLPROF Project 1: DMC (PSI)

Project 2: RITA-2 (PSI) PSI cold source Straight guide Curved monochromator Soller collimator Vanadium / phonon sample Single analyzer Single detector (+ diagnostic monitors) Data analysis in MFIT

Project 3: SANS-2 (PSI) PSI cold source Straight guide Velocity selector Pinhole collimation (3/6 m) SANS sample PSD detector (+ diagnostic monitors) Simple data analysis (Gunier, Perot) (right) Virtual data. Hard spheres, 50 nm,

Real experiments PSI, June groups of 3 M.Sc. students SANS-2 under repair RITA-2, 3 days each No repetition of simulations! Spin wave projects (α-MnMoO 4 ) Data analysis in MFIT Students very self confident even tough instrumentation (multi-analyzer mode)

Conclusion M.Sc. students like the approach (continue with neutrons) Excellent student reports! “hands-on” experience to instrumentation Students act experienced on Day-1 Better understanding for semi-experienced Ph.D. students Good beta-test of McStas 1.9! Focused efforts to get virtual experiment concepts tested This will be continued!