- 1 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Guided tour through:  Configuration  Defining spectral range  Scan control.

Slides:



Advertisements
Similar presentations
Multiphoton and Spectral Imaging. Multiphoton microscopy Predicted by Maria Göppert-Mayer in 1931 Implemented by Denk in early 1990s Principle: Instead.
Advertisements

Chapter3 Pulse-Echo Ultrasound Instrumentation
Good Practices of Fluorescence Spectroscopy
Photoshop Lab colorspace A quick and easy 26 step process for enhancing your photos.
Dave Piston May 18, 2014 Optical Sectioning 2: Confocal Designs and “Pseudo-confocals” Outline 1.PMT detectors 2.Laser Scanning Design Features 3.Pseudo-confocals.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
Lasers and Confocal. Laser Acronym: Light Amplification by Stimulated Emission of Radiation Ordinary light emission: Comes from spontaneous decay of excited.
This is a guide for using the Zeiss LSM510 Confocal Microscope. Do not attempt to use this microscope without the proper training. If you have any queries.
EPOCH 1000 Series Procedure Phase Array Straight Beam Calibration
(0)Start system, computer, LSM (AIM) programme, Hg ARC lamp (HOT???) and tungsten lamp !!
(1)Start lasers, then find sample using VIS. (2)Set configuration using LSM.
EDAX Operation Operation of the Phoenix EDAX system
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Camera Functions Using Your Digital Camera. 1. What happens when you press the shutter button down halfway? What does macro mode allow you to do? Pressing.
Scanning and Image Processing -by Steve Clough. GSI Lumonics cDNA microarrays use two dyes with well separated emission spectra such as Cy3 and Cy5 to.
Practical aspects of fluorescence microscopy
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
Live Cell Fluorescence Imaging Presented by: Nicholas Beavers – Media Cybernetics, Inc. Welcome to Sponsored by Starting Soon…
[1] Reference: QCam API reference manual document version Charge Coupled Device (CCD)
Ircon ® ScanIR ® 3 Linescanner How to work with Snapshots? Confidential Rev. A 07/2013.
The current state of Confocal Scanning Laser Microscopy Hjalmar Brismar Cell Physics, KTH.
- 1 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Guided tour through:  Configuration  Defining spectral range  Scan control.
High-Resolution Interactive Panoramas with MPEG-4 발표자 : 김영백 임베디드시스템연구실.
May Chuck DiMarzio, Northeastern University ECE-1466 Modern Optics Course Notes Part 7 Prof. Charles A. DiMarzio Northeastern University.
Microscope Control Configuration This section of the QED manual will describe how to configure you Configure and Control your automated microscope. Mac.
Continuous processing and evaluation of experimental data is highly needed 2.1. Organization of work, type of data 2. Helpful hints in the processing of.
Taking Better Confocal Images Kim Peifley 2/09/15.
EPOCH 1000 Series Procedure Phased Array Angle Beam Calibration
March 2004 Charles A. DiMarzio, Northeastern University ECEG287 Optical Detection Course Notes Part 15: Introduction to Array Detectors Profs.
FROM IMAGES TO ANSWERS Live Cell Imaging - Practical Issues Silver Spring & San Diego, June 2005.
Tiling Z Stacks on the LCI510 Kim Peifley 03/23/15.
CS TC 22 CT Basics CT Principle Preprocessing. 2 CT Basics CT principle preprocessing CS TC 22 Blockdiagram image processor.
Digital Image Processing
Intelligent Robotics Today: Vision & Time & Space Complexity.
Peterson xBSM Optics, Beam Size Calibration1 xBSM Beam Size Calibration Dan Peterson CesrTA general meeting introduction to the optics.
Continuous processing and evaluation of experimental data is highly needed 2.1. Organization of work, type of data 2. Helpful hints in the processing of.
Use Snell’s law to determine the angle of total internal reflection in the coverslip (without oil). Oil immersion objectives More light (no total internal.
Program Design for REMPI Jingming Long 08/02/2010.
Introduction to Layers GIMP User Manual. What is a Layer? Every image in GIMP is made by combining one or more images called Layers laid on top of each.
1 Setting Laser Power and PMT Gain Begin with laser power at 20% Set PMT gain to 6.00.
Date of download: 7/6/2016 Copyright © 2016 SPIE. All rights reserved. Optical setup and schematic description of the acquisition. (a) Optical setup inside.
SalsaJ (Such a Lovely Software for Astronomy) Practical Session.
Date of download: 7/7/2016 Copyright © 2016 SPIE. All rights reserved. The spectral overlap of Cerulean or mTFP with Venus is compared. The excitation.
Biology 227: Methods in Modern Microscopy Andres Collazo, Director Biological Imaging Facility Yonil Jung, Graduate Student, TA Week 10 Multispectral Imaging.
What is a digital image ? 1.
Mapping EP4.
Lasers and Confocal.
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Oil immersion objectives
Radio Quality Indication
Standard Operation Procedure
Spectral Flow Cytometry
Volume 84, Issue 6, Pages (June 2003)
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Volume 104, Issue 4, Pages (February 2013)
Molecular Dynamics in Living Cells Observed by Fluorescence Correlation Spectroscopy with One- and Two-Photon Excitation  Petra Schwille, Ulrich Haupts,
Volume 95, Issue 7, Pages (October 2008)
Volume 99, Issue 8, Pages (October 2010)
Multiphoton Microscopy for the Investigation of Dermal Penetration of Nanoparticle- Borne Drugs  Frank Stracke, Barbara Weiss, Claus-Michael Lehr, Karsten.
Mechanical Distortion of Single Actin Filaments Induced by External Force: Detection by Fluorescence Imaging  Togo Shimozawa, Shin'ichi Ishiwata  Biophysical.
Volume 101, Issue 10, Pages (November 2011)
Volume 89, Issue 2, Pages (August 2005)
Harvard Medical School Neurobiology Imaging Facility
Volume 99, Issue 4, Pages (August 2010)
Harvard Medical School Neurobiology Imaging Facility
Michael Blanchard Imaging Technician
Polarized Fluorescence Resonance Energy Transfer Microscopy
NA determines intensity.
Transition to the Dark Side
Presentation transcript:

- 1 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Guided tour through:  Configuration  Defining spectral range  Scan control settings - optimal pinhole size - detector gain, amplitude offset - range indicator  Emission Fingerprinting 1. Acquire Lambda stack 2. Reference Spectra - using ROI’s - using Spectral Database 3. Unmix Emission Fingerprinting

- 2 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Mode 2 - Lambda Mode 1. Acquire a Lambda Stack* 2. Select Reference Spectra 3. Perform Linear Unmixing and view the results Emission Fingerprinting - the Method 1. *contains spectral information for each pixel

- 3 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Getting started 2) Select Acquire 3) Select Laser switch on required Laser lines Argon laser power should be  60 % 4) Select Micro choose objective lens from pulldown menu select appropriate Filterset for fluorescence (e.g. FS01 for DAPI, FS09 for GFP) 1) start the software 5) switch to LSM mode

- 4 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Configuration 1) select config and then Lambda Mode 2) Define spectral range for Lambda stack acquisition NOTE: for specimen protection --> keep number of passes low! 4) Select main dichroic beam splitter (HFT) 3) Select excitation laser lines and set transmission values

- 5 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Scanning Parameters 1) Select Scan and Mode 2) Select Frame size as predefined number of pixels or enter your own values (e.g. 512x72) number of pixels influences scanning resolution 3) enter scan speed and select Scan average (slower scan speed and averaging gives best signal/noise ratio) 4) Select dynamic range 8 bit yields 256, 12 bit 4096 levels NOTE: Images for publication should be acquired using 12 bit and high number of pixels

- 6 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Adjusting Pinhole 1) Select Scan and Channels 2) set pinhole size 1 Airy units produces best signal/noise ratio Pinhole adjustment changes „optical slice“ (i.e.confocality) NOTE: Pinhole 1 controls all 32 META detector elements

- 7 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Acqusition 1) Select Find to automatically pre-adjusts detector sensitivity 2) Select Fast XY for continous fast scanning (useful for finding and changing the focus) 3) Use Single or Cont to Start Acquisition...

- 8 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Emission Fingerprinting- Range Indicator 1) Select Palette 2) Select Range Indicator Red = Saturation (Maximum) Blue = Zero (Minimum)

- 9 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Emission Fingerprinting- Set Gain & Offset Detector Gain determines sensitivity of the detector by setting the maximum limit Ampl. Offset determines the minimum intensity limit Ampl. Gain determines signal amplification Saturation at Maximum  reduce Detector Gain Saturation at Minimum  increase Ampl. Offset Gain Offset Offset set correctly Gain set correctly Ampl. Gain increases whole signal, and the offset will need to be decreased

LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April ) Define different Region’s of Interest (corresponding spectra are displayed in graph on the left) 1) Select Mean Mode 3) click Linear Unmixing Emission Fingerprinting - using ROI’s

LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Emission Fingerprinting - using Spectral DB If no clear spectral separation between different areas is possible, then reference spectra need to be obtained from individual controls 2) In MeanROI Mode, draw Region of Interest 3) Save Spectra to Database 1) Acquire Lambda stack

LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Emission Fingerprinting - using Spectral DB 4) select existing or create new folder 5) Assign appropriate name and enter comments (optional), then Save 6) Repeat steps 1) - 5) for all necessary individual controls (including Autofluorescence and background) IMPORTANT: All controls have to be obtained under the SAME CONDITIONS (i.e. same system, HFT, detector range and objective!!!) Otherwise unmixing will return false results!!! NOTE: Reference spectra will be normalized to the maximum intensity and can be displayed either as spline curve or raw data points (use right mouse button for switching)

LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Emission Fingerprinting - using Spectral DB 1) From Main Menu, select Process and the Unmix 2) Select individual previously saved reference spectra from folder, assign channel and color 3) select Lambda stack (Source) for unmixing, click Apply...

LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Linear Unmixing – How it works! = + a x GFPb x YFP Unmixing separates the total emission signal into weighted contributions of each dye based on the knowledge of their “emission fingerprints” – pixel by pixel! Combined spectra

LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Emission Fingerprinting What is Emission Fingerprinting? 3-step-method for (1) recording, (2) analysis and (3) separation of emission signals in multifluorescence imaging Separation of individual emissions based on the recording of spectral signatures and a digital unmixing procedure using reference spectra What is it good for? Separation even of fluorochromes with widely overlapping emission spectra Separation of fluorochromes that are excited by the same laser line (in single- photon and multiphoton microscopy) Elimination of background- and autofluorescence Lambda Stack recording and export of spectral data can be sufficient for some applications (environmental changes affect emission spectra

LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Emission Fingerprinting Don’t’s Do not saturate Lambda Stack channels Do not change configuration for controls and final experiment Do not use “library spectra”