work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.

Slides:



Advertisements
Similar presentations
USE OF GEANT4 FOR LHCB RICH SIMULATION S. Easo, RAL, LHCB AND ITS RICH DETECTORS. TESTBEAM DATA FOR LHCB-RICH. OVERVIEW OF GEANT4 SIMULATION.
Advertisements

Barrel PID upgrade K. Inami (Nagoya-u) and PID group - R&D status - TOP counter - iTOP - Focusing DIRC - To do, cost estimation.
CLAS12 – RICH PARAMETERDESIGN VALUE Momentum range3-8 GeV/c  /K rejection factor Not less than 500  /p rejection factor Not less than 100 Angular coverage5.
Mar 31, 2005Steve Kahn -- Ckov and Tof Detector Simulation 1 Ckov1, Ckov2, Tof2 MICE Pid Tele-Meeting Steve Kahn 31 March 2005.
Review of PID simulation & reconstruction in G4MICE Yordan Karadzhov Sofia university “St. Kliment Ohridski” Content : 1 TOF 2 Cerenkov.
Marco Musy INFN and University of Milano-Bicocca Pylos, June 2002 Aerogel as Cherenkov radiator for RICH detectors for RICH detectors.
Development of FARICH-detector for the ALICE experiment at CERN A.I.Berlev, T.L.Karavicheva, E.V.Karpechev, Yu.V.Kupchinskiy, A.B.Kurepin, A.N.Kurepin,
The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 Shibata Lab 11R50047 Jennifer Newsham YSEP.
Carsten Schwarz PANDA June 2004 CID Cherenkov Imaging Detectors ● RICH software at HERMES, Ralf Kaiser, Glasgow ● Present status of DIRC, C.S., GSI ● Spiralling.
Peter Križan, Ljubljana March 17, 2006 Super B Workshop, Frascati Peter Križan University of Ljubljana and J. Stefan Institute Aerogel RICH and TOP: summary.
Position Sensitive SiPMs for Ring Imaging Cherenkov Counters C.Woody BNL January 17, 2012.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
Comparison of Endcap CID-PID Klaus Föhl PID meeting 27/3/2007 panda-meeting Genova Focussing Lightguides Time-of-Propagation Proximity Focussing.
May 31, 2008 SuperB PID sessionMarko Starič, Ljubljana Marko Starič J. Stefan Institute, Ljubljana Report on hardware tests and MC studies in Ljubljana.
1 Fast Timing via Cerenkov Radiation‏ Earle Wilson, Advisor: Hans Wenzel Fermilab CMS/ATLAS Fast Timing Simulation Meeting July 17,
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Threshold aerogel Cherenkov counters of the KEDR detector A.Yu. Barnyakov *, M.Yu. Barnyakov, V.S. Bobrovnikov, A.R. Buzykaev, A.F. Daniluk, S.A. Kononov,
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
Study of a Silica Aerogel for a Cherenkov Radiator Ichiro Adachi KEK representing for the Belle Aerogel RICH R&D group 2007 October RICH2007, Trieste,
EIC Detector – JLab – 04/June/2010 Cisbani / HERMES RICH 1 HERMES: Forward RICH Detector Evaristo Cisbani / INFN-Rome Sanità Group Most of the slides from.
A RICH with Aerogel for a hadron machine On behalf of the LHCb RICH group Some results and considerations on: Cerenkov angle resolution from aerogel Index.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Cherenkov Counters for SoLID Z.-E. Meziani on behalf of Simona Malace & Haiyan Gao (Duke University) Eric Fuchey (Temple University) SoLID Dry Run Review,
Aerogel counter with a Fresnel lens
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
AMS-RICH Detector. J. Berdugo – CIEMAT (Madrid, Spain) 1 AMS-02 Phase II Flight Safety Review AMS Ring Imaging CHerenkov PURPOSE: 1.Precise measurement.
BURLE update Peter Križan Friday meeting, Mar 24, 2006.
Peter Križan, Ljubljana March 6, 2006 CBM RICH Workshop Peter Križan University of Ljubljana and J. Stefan Institute RICH counters for HERA-B and Belle.
Simulations of Light Collection Efficiency (JLab Hall C 12 GeV Kaon Aerogel Detector) Laura Rothgeb Nuclear Physics Group Catholic University of America.
Scan ~100 bar entry positions with laser diode measures transmitted intensity (relative to reference intensity) determine attenuation length (Λ) by aiming.
RICH detector for CLAS12 CLAS12 Technical Workshop P. Rossi Laboratori Nazionali di Frascati - INFN.
RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1 JLAB12.
RICH Simulation in LHCb LHC Detector Simulation Workshop S.Easo, RAL, On behalf of LHCb–RICH group.
Aerogel Cherenkov Counters for the ALICE Detector G. Paić Instituto de Ciencias Nucleares UNAM For the ALICE VHMPID group.
Radia Sia Syracuse Univ. 1 RICH 2004 Outline:  The CLEO-III RICH Detector  Physics Requirements  CLEO-III RICH at work… Performance of the CLEO-III.
RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1JLAB12.
RICH MEETING - CERN - April 21 st 2004 Università degli Studi di Milano Bicocca Variation of Refractive Index inside an Aerogel Block Davide Perego.
Tests of a proximity focusing RICH with aerogel as radiator and flat panel PMT (Hamamatsu H8500) as photon detector Rok Pestotnik Jožef Stefan Institute,
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
TORCH IOP meeting Manchester March 31, 2015 TORCH Maarten van Dijk On behalf of the TORCH collaboration (CERN, University of Oxford,
Aerogel RICH & TOP counter for super KEKB Y.Mazuka Nagoya University June 14-16, 2006 The 3 rd SuperB workshop at SLAC.
TORCH – a Cherenkov based Time-of- Flight Detector Euan N. Cowie on behalf of the TORCH collaboration E N Cowie - TORCH - TIPP June 2014.
RICH studies for CLAS12 L. Pappalardo1 Contalbrigo Marco Luciano Pappalardo INFN Ferrara CLAS12 RICH Meeting – JLab 21/6/2011.
Aerogel detector revisited Sokolov Oleksiy, UNAM, progress report, 20 Sept 2006 E int = M – wall reflectivity є – PMT relative area Belle geometry (traditional):
Matthias Hoek Institut für Kernphysik Next Generation Cherenkov Counters* *For Accelerator Experiments 52. International Winter Meeting on Nuclear Physics.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
Focusing Aerogel RICH Optimization A.Yu.Barnyakov, M.Yu.Barnyakov, V.S.Bobrovnikov, A.R.Buzykaev, V.V.Gulevich, S.A.Kononov, E.A.Kravchenko, A.P.Onuchin.
Proximity focusing RICH with TOF capabilities for the Belle upgrade
Overview of SuperB Particle identification, and work towards the TDR
Particle Identification (PID) at HIEPA Experiment
Status of the PandaRoot simulation of the Forward RICH
Status of GEANT4 in LHCb S. Easo, RAL, The LHCb experiment.
Focusing Aerogel RICH with SiPM Photodetectors
E.A.Kravchenko Budker INP, Novosibirsk, Russia
KM2A Electron Detector Optimization
Focusing Aerogel RICH for PID and Momentum Measurement
Contalbrigo Marco INFN Ferrara RICH 2016, September 9th 2016, Bled
Particle Identification in LHCb
RICH simulation for CLAS12
E.A.Kravchenko Budker INP, Novosibirsk, Russia
Multianode Photo Multipliers for Ring Imaging Cherenkov Detectors
RICH simulation for CLAS12
Development of microchannel plate phototubes in Novosibirsk
E.A.Kravchenko on behalf Novosibirsk group
Development of the PANDA Forward RICH with an aerogel radiator
E.A.Kravchenko Budker INP, Novosibirsk, Russia
Performance test of a RICH with time-of-flight information
Presentation transcript:

work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk

E.A.Kravchenko, work for PID in Novosibirsk"2 May 10, 2007 MC simulation of RICH with aerogel and NaF radiators on MCP PMTs  Life-time tests  3 MCP PMTs Status of multilayer aerogel production and characterization Conclusion Outline

E.A.Kravchenko, work for PID in Novosibirsk"3 May 10, 2007 Sodium fluoride radiator Suggested for RICH with a TEA/TMAE pad-photon detector by R. Arnold et al. [ NIM A273 (1988) 466 ] Good transparency in visible & near UV, Almost no light scattering as compared with aerogel, More firm and stable material, though toxic. √2√2 NaF has the lowest refractive index among solids (except aerogel). for λ >170 nm Cherenkov photons refracts out for normal incidence particle, β≈1 CAPRICE RICH (balloon-borne, flight in 1994): 10mm thick NaF looked by MWPC with TMAE, pad read-out. AMS-02 RICH (ISS-borne, tested with beam 2003): 34x34x0.5cm NaF & aerogel n=1.05 looked by MA-PMT array

E.A.Kravchenko, work for PID in Novosibirsk"4 May 10, 2007 Aerogel radiators for comparison SLA 12mm – single layer aerogel with n=1.07 SLA 24mm – single layer aerogel with n=1.07 FASR-6 – 6-layer aerogel with single ring FAMR-3 – 3-layer aerogel with 3 rings A.Yu. Barnykov, et al., NIM A553 (2005) 125 A.Yu.Barnyakov, et al., Proceedings of SNIC 2006, eConf C (2006) 0045 FASR-6 gives the best performance at β≈1: Npe = 13, σ β = 5∙10 -4 π/K separation up to 8 GeV/c (better 3σ) A low momentum solution wanted below aerogel threshold: Time-of-flight built in aerogel RICH ( suggested and tested by Belle RICH group) Higher refractive index radiator

E.A.Kravchenko, work for PID in Novosibirsk"5 May 10, 2007 NaF vs aerogel Normal incidence particles 30 o incidence

E.A.Kravchenko, work for PID in Novosibirsk"6 May 10, 2007 π/K separation 30 o incidencenormal incidence NaF: up to 5 GeV/cNaF: up to 3.5 GeV/c Radiator in the endcap can be tilted so that: | θ i | <20 o

E.A.Kravchenko, work for PID in Novosibirsk"7 May 10, 2007 Single photon position resolution NaF is less demanding to pixelization. ~ 4000 channels in the forward RICH For 100 mm expansion gap single layer aerogel RICH needs channels, focusing RICH – channels)

E.A.Kravchenko, work for PID in Novosibirsk"8 May 10, 2007 NaF-aerogel multi-ring radiator concept The focusing condition for aerogel is yet to be investigated… FASR NaF

E.A.Kravchenko, work for PID in Novosibirsk"9 May 10, 2007 on MCP PMTs Fast degradation of QE was found at long wavelengths can be used for early detection of ageing 800 nm – wavelength for comparison of PMT samples after tests

E.A.Kravchenko, work for PID in Novosibirsk"10 May 10, 2007 Photocathode ageing of the different design MCP PMTs Photocathode ageing is rate dependent Counting rate was increased from test to test keeping the integrated cathode charge constant ( ~5 nC) 3 MCP PMTs have the same life time as 2 MCP with protective layer

E.A.Kravchenko, work for PID in Novosibirsk"11 May 10, 2007 Fast comparison of photocathode aging Photon counting rate sec -1 Duration – 30 minutes Multiplication coefficient Number of tested tubes Average QE degradation at 800nm 'old' PMT with 2 MCPs 1027% 'new' PMT with 3 MCPs % We expect much longer lifetime of ‘new” designed PMTs in real experimental conditions

E.A.Kravchenko, work for PID in Novosibirsk"12 May 10, 2007 Multilayer aerogel production and characterization 100x100x41 mm, Lsc = 45 mm at 400 nm Layernn, (designed) h, mmh, mm (designed) σ (n-1) in the layers ~ 1.5 % - small effect on angle resolution

E.A.Kravchenko, work for PID in Novosibirsk"13 May 10, 2007 Conclusion Use of NaF radiator in the forward RICH looks very promising (PID at low momenta, small number of channels) Procedure for fast ageing tests of MCP PMTs has been developed PMTs with 3 MCPs have life time at least as long as 2MCP PMTs with protective layer Large 3 layers aerogel block has been produced and characterized

E.A.Kravchenko, work for PID in Novosibirsk"14 May 10, 2007 Additional slides

E.A.Kravchenko, work for PID in Novosibirsk"15 May 10, 2007 Monte Carlo simulation (GEANT4) Detector components Geometry Geometry: D = 100 mm - from radiator input face to photodetector plane Aerogel properties:  Rayleigh scattering length: 5 cm at 400 nm  Aerogel bulk absorption length: 400cm at 400 nm Photodetector:  Bialkali photocathode with borosilicate window QE max =24%  Overall efficiency factor: 50% (packing density & pe collection efficiency)Physics The processes defined: The processes defined:  for charged particles: Cherenkov emission, multiple scattering  for optical photons: Fresnel refraction and reflection, Rayleigh scattering, bulk absorption. Effects considered: Effects considered:  Dispersion of refractive index  Emission point uncertainty  Scattered photons are discarded  Position resolution of photodetector not considered

E.A.Kravchenko, work for PID in Novosibirsk"16 May 10, 2007 Optimization of NaF radiator N pe σθσθ 3.5 GeV/c Thickness 10 mm => 9% X 0 at normal incidence

E.A.Kravchenko, work for PID in Novosibirsk"17 May 10, 2007 Technical requirements on multilayer aerogel, single ring (index of refraction) Accuracy on the refractive index in the layers 6-layer option 2 cases – “correlated” (all layers change equally) “anti-correlated” (half of the layers increase, other decrease)

E.A.Kravchenko, work for PID in Novosibirsk"18 May 10, 2007 Technical requirements on multilayer aerogel, single ring (longitudinal density variations) Accuracy on the density variations along the track case sensitive negative – variation in the layer from low values to high (continuous focusing) positive – variation from high values to low Technical requirements on multi ring aerogel are more simple!