10 years of evolution in UHPLC-MS chromatography. Current trends. Eduard Rogatsky Albert Einstein College of Medicine Einstein-Montefiore Institute for.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

Chem. 231 – 3/4 Lecture. Announcements I Set 1 Lab Reports –Both Lab Reports due 3/13 –Only one of the lab reports needs to be detailed, the other can.
Cruces-Blanco, C., Gamiz-Gracia, L., Garcia-Campana A.M., Applications of Capillary Electrophoresis in Forensic Analytical Chemistry Trends in Analytical.
Lab Methods Day June 25, 2014 Gas Chromatography
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
1 1. Introduction H: High P : Performance (Pressure) L : Liquid C : Chromatography GC : Gas chromatography TLC: Thin layer chromatography IC : Ion chromatography.
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
© Copyright 2002 ABB. All rights reserved. - Microelectromechanical Systems for Process Analytics IFPAC 2003 Dr. Berthold Andres ABB Automation Products.
Lecture 9 Yuri Kazakevich Seton Hall University
Gradient Manipulation and 1.8 µm LC Columns for High Resolution Analysis of Herbal Supplements John W Henderson Jr, Thierry Faye, Ulrik Witteg, Maureen.
Chapter 6 - Chromatography
Introduction to the HPLC ChemStation and Acquisition.
Created with MindGenius Business 2005® Performance parameters (Advanced) Theoretical Plate Model Performance parameters (Advanced) Theoretical Plate Model.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
CENTRIFUGE DRIER / FILTER « CENTRIFILTER » APPLICATION: Particles and water contaminants are the most usual cause of problems in process analyse. According.
High Performance Liquid Chromatography
High Performance Liquid Chromatography (HPLC) Jeannette Comeau CHEE April 2004.
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
High Performance Liquid Chromatography Instrumentation.
ProStar 210/218 Solvent Delivery Modules
Varian 920-LC Integrated Analytical HPLC
Sample Preparation Strategies for Routine Trace Mixture Analysis by NMR David Detlefsen, Kenneth Ray & Jeffrey Whitney.
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
Simple Scale-up on a 940-LC Analytical to Preparative HPLC
900-LC P. van Poppel – Field Support Specialist October 2009.
VARIAN, INC. HPLC Products
Peptide hormones: the sensitivity quest and sensitivity questions. Eduard Rogatsky Albert Einstein College of Medicine Einstein-Montefiore Institute for.
Sales Objections and FAQs 920-LC Analytical Systems.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY.
212-LC Pump Technology Background August Dual Piston Pump Single piston pumps deliver then refill, forcing the use of a very large pulse damper.
Improving the Detection of Hydrophilic Peptides for Increased Protein Sequence Coverage and Enhanced Proteomic Analyses Brian S. Hampton 1 and Amos H.
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
Waters HPLC Competitive Review
Chapter 28 High Performance Liquid Chromatography.
Varian 920-LC Competitors. 2 Varian 920-LC Market Competitors Competitors Shimadzu Waters Agilent Dionex The 920-LC presents a significant step forward.
LC/MS method transfer: surprises and troubleshooting.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
Liquid Chromatography 2: New Technology Lecture Date: April 3 rd, 2007.
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
Comparison of the Varian 920-LC with Agilent 1200 Series HPLC.
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Determination of metformin in urine (by Liquid Chromatography LC)
The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole.
Protein Identification using 2D LC/MS/MS based on pH Gradient and Reverse Phase Separation Column Technology Inc.,
J.Heřt. -synonyms: solid core particles, Fused-core particles -Most recent available particle size is 1.7  m (core 1.25  m, layer 0.23  m)
Downloaded from کروماتوگرافی CHROMATOGRAPHY Downloaded from
Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Accucore UHPLC & HPLC Columns
James Byrd, Marta Kozak 28 Apr 2011
LIQUID CHROMATOGRAPHY
For Forensic Toxicology use Only
Automation of Solid Phase Extraction Column Chromatographic Cleanup
Automation of Sample Preparation for Trace Analysis Haibin Wan
Horizon Chromatography
Running the BioLogic DuoFlow Starter Kit
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Setting up, testing and running LC-systems
Liquid Chromatography - Method Development and Validation
Introduction to the NGC Chromatographic System
High-Performance Liquid Chromatography
33A-2 Pumping Systems The requirements for liquid chromatographic pumps include the generation of pressures of up to 6000 psi (lb/in2), (2) pulse-free.
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
32A-2 Sample Injection system
David Thornton1, Xiqin Yang1, Gary Yanik2 and Leo Hsu1*
High-Performance Liquid Chromatography
Presentation transcript:

10 years of evolution in UHPLC-MS chromatography. Current trends. Eduard Rogatsky Albert Einstein College of Medicine Einstein-Montefiore Institute for Clinical & Translational Research Bronx, NY

National Automobile Museum The Harrah Collection, Reno, NV

1912 BAKER - electric 1913 STANLEY -steam 1912 SELDEN - gasoline In July 1886 the newspapers reported on the first public outing of the three-wheeled Benz Patent Motor Car, model no. 1. Reproduced with permission

1960s-1980s HPLC 1980s-2000s “Conventional” HPLC Present Acquity UPLC (2004) HPLC Instrument Development Milestones ?

HPLC Instrumentation Development UHPLC was introduced 10+ years ago. This new technology, while having great promise for improved efficiency and productivity, has not to date displaced HPLC. This transition will be slow process. Currently, both HPLC and UHPLC can be working in the same lab. 1992, MS-DOS 1998, Windows , Windows XP

UHPLC it is not only a system that’s capable of operating at higher pressures. UHPLC is optimized to work with sub 2 micron ultra – high resolution columns to produce very narrow sharp chromatographic peaks. UHPLC –in contrast to conventional HPLC, is a low dwell volume system designed for fast runs at high pressure. UHPLC vs HPLC

Current trends in chromatography Transition from HPLC to UHPLC Evolution of conventional HPLC for full support of Fused-Core chromatographic columns (delay volume reduction) Evolution of UHPLC Chromatography with Mass Spectrometry analysis.

UHPLC performance UHPLC performance is mostly based upon correct choice of flow rate, operating pressure, dwell/post-column volume and chromatographic column. Choice of these parameters is not module-based. Correct choice is system-based.

UHPLC : pressure and flow rate impact Autosampler Pump Column thermostat Detector Injector valve, wash port, sample loop size Purge valve, mixer Heat exchanger Switching valve Flow-cell design, pressure and volume LC devices Critical components and parameters

Column guard: contamination by rotor seal wear debris LC column: Increase backpressure

Rotor seal dust

Agilent 1290 UHPLC. Adjustable fitting in the column compartment

Heat exchanger outlet tubing design 1/16 OD 1/32 capillary, that have limited resistance to mechanical stress during column installation

Delay volume-pressure impact: 15% drop of mixing efficiency Upchurch filter in the pump, no damper, valve, restrictor, Flow rate 0.7 ml/min Blue: Low Pressure V ml; V ml Red: High Pressure 344Bar, V ml; V ml The more shallow slope results in a larger V 50, [poor mixing] as well as smaller V 0 Low Pressure High Pressure 344Bar V ml V ml

IDEX PEEK Lined SS

V50 increase with pressure Pressure, bar

Summary New experience: moving parts and mixers are less rugged and efficient in high pressure applications.

UHPLC and MS UHPLC/UV requires baseline separation In contrast, MS detection utilizes ions resolution by m/z and chromatographic peaks overlay is typical in LC/MS analysis.

2D chromatography – efficient way to increase peak capacity. It is important for UV applications, but in general, not for LC/MS applications 2D and LCMS Benefits of 2D in MS: Minimum of signal suppression Better background Better peak shape More clean instrument

UHPLC 2D/MS Agilent 1290 series

Matrix effect reduction - One column method SPE AcN/Phospate sample S/N p/p =16.1

Matrix effect reduction - Two column method SPE AcN/Phospate sample 12.6 fold improvement S/N p/p =201.4

Chromatography myth Single column chromatography is always more robust, compared to column switching applications. That’s true – if we are comparing standard pressure ranges. High pressure operations are less robust and more expensive - compare to standard LC Is it possible to combine more robust standard pressure/larger volume sample injection with UHPLC?

New paradigm: sample injection via standard LC followed by UHPLC chromatography. The sample was injected by a standard (not UHPLC) autosampler into a pre-analytical column, where it was desalted and partially purified. A standard pressure range binary HPLC pump was used. The fraction containing analytes of interest was transferred through a UHPLC valve to a fused core column. A fast gradient was performed using a UHPLC 1290 pump.

LCxUHPLC

Online SPE design LCxUHPLC design based on HPLC loading pump and UHPLC LC/MS pump uu Standard LC pump – loading step fused core column

Human C-peptide Plasma SPE

Urinary cortisol and testosterone –single column Testosterone 10 ul urine, 1:3 diluted cortisol

Urinary cortisol and testosterone -trap Testosterone RT 3.5 min; was 5 10 ul urine, 1:3 diluted cortisol

MMA from plasma 1D: trap +column MMA

MMA from plasma 1D: trap +column MMA

MMA from plasma 2D: trap loading +column switching Column switching improves S/N from 214 to 334; aprox. 40% gain MMA

33 Fused-Core Ascentis Express Particles Comparison of architecture of Fused- Core™ particles vs. porous 3 µm particles

2x50 Polaris C18 3µm 180 A versus 2x30 Ascentis Express Peptide 160A S/N 170 S/N 40 Low loading capacity –the main limitation factor of the Fused-Core material – was overcome by using 2D chromatography. Only small, C-Peptide containing fraction was loaded [transferred] onto the column.

Column comparison in the second dimension under the same conditions Peak 1: Aeris Peptide C18, 3.6 um 2.1 x50 mm (fused-core); Peak 2: XBridge C18, 3.5 um 2.1x30 mm; Peak 3: Ascentis Express Peptide C18, 2.7 um 2.1 x 30mm (fused-core)

Summary 1 LCxUHPLC is more rugged column switching system, compare to 2D UHPLC UHPLC sample loading is limited Sample loading to trap, using standard LC pump and autosampler is more convenient and cost efficient Loading and wash step using trap greatly improve ruggedness of mass spectrometer operations

Hybrids typically have: More functionality Higher cost, compare to its components, Only basic control and features Less ruggedness Limited support LCxUHPLC is free from these disadvantages

We successfully used LCxUHPLC platform for LC/MS analysis. Instead of retiring an entire functioning Agilent 1100 LC system, we just added one UHPLC pump to achieve much greater overall performance, functionality and lower cost, compared to a single pump UHPLC system purchase. Take Home Message

Summary 2 The addition of a UHPLC valve and pump to a standard 1100/1200 series LC system (autosampler, pump and column compartment) greatly extends operational flexibility including column selection, while standard LC – which is already available in the lab, performs the initial steps of sample loading and clean-up

Funding: This research was supported in part by a Clinical and Translational Science Award (CTSA) from the National Institutes of Health (UL11RR025740) awarded to the Albert Einstein College of Medicine of Yeshiva University. NIH: R01 DK Technical Support: Agilent Technologies IDEX corporation/Upchurch scientific Optimize Technologies Acknowledgements