GTK gas coolingsystem status Marco Statera, Vittore Carassiti, Ferruccio Petrucci, Luca Landi NA62 - GTK working group meeting 12-7-2011.

Slides:



Advertisements
Similar presentations
Air Conditioners and Heaters
Advertisements

ADX 150 – Engine Repair ADX 170 – Climate Controls
RHIC CRYOGENICS SYSTEM Time meeting /28/20141TIME MEETING RUN 14 –CRYOGENIC.
23 October 2005MICE Meeting at RAL1 MICE Tracker Magnets, 4 K Coolers, and Magnet Coupling during a Quench Michael A. Green Lawrence Berkeley Laboratory.
Ram C. Dhuley Steven W. Van Sciver
Test plan for the MICE SS cryostat and magnet Tapio Niinikoski LBNL Spectrometer Solenoid Workshop May 10, 2011.
Simple distillation and fractional distillation
PAX DETECTOR THERMAL SIMULATION 1Vittore Carassiti - INFN FEFz-Juelich, 27/10/2008.
CASIPP Design of Cryogenic Distribution System for CFETR CS model coil Division of Cryogenic Engineering and Technical Institute of Plasma Physics Chinese.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling.
Some results of vacuum stand investigation.. 1. Restoration of turbopump inlet valve V1 tightness The inlet turbopump valve of the first pump station.
Air Conditioning in tropical climates Presented by Ranjeet Kumar Nayak.
23 Jan 2007 LASA Cryogenics Global Group 1 ILC Cryomodule piping L. Tavian for the cryogenics global group.
ESS Cryogenic Distribution System for the Elliptical Linac MBL/HBL - CDS requirements Preliminary Design Review Meeting, 20 May 2015, ESS, Lund, Sweden.
1 Liquid Hydrogen R&D test report Video Conference – 23/08/12 S Watson P Warburton M Courthold.
CRYOGENICS FOR MLC Cryogenic Cooldown Scheme Eric Smith External Review of MLC October 03, October 2012Cryogenics for MLC1.
IHEP 1.3 GHz Cryomodule and Cryogenics IHEP Cryogenic group 2nd Workshop of the IHEP 1.3 GHz SRF R&D Project Dec 2 nd, 2009.
ca Main Bullet #1 Main Bullet #2 Main Bullet #3 HXMA WIGGLER MAINTENANCE REVIEW Linda Lin June 2010.
4/12/2011Controller Cooling Test1 Array Controller Cooling Test Bill Hoffmann April 12, 2011 This is a report on a test of the chilled water-to-air heat.
NA62 – GTK Cooling Station 1 Main characteristics Fluid: C 6 F 14 (fluorocarbon) Operating temperature: -30 °C ÷ -10°C Temperature precision: ±1 K Temperature.
Arnaud Vande Craen (TE-MSC) 27/02/20131 EUCARD : ESAC Review – CEA Saclay.
Hydrogen Pre-Operation Safety Review 4 th October 2011 Results from Helium Commissioning M Hills.
Some notes about liquid Hydrogen target 1.How it operates 2.Modification Target length, empty mode 4.Status.
AIDA Traci commissioning LHCb – CO 2 cooling meeting 18 March 2015 Kamil Wojdyla, Lukasz Banasik, Nicola Spadavecchia, Tomasz Kucharski, Piotr Dziurdzia,
Cooling System Solutions
EMAS Stirling Cooler Operations Feb 24, 2011 Mike Watson.
C.KotnigFCC Design Meeting FCC Beam Screen cooling Claudio Kotnig.
9/17/07IRENG071 Cryogenic System for the ILC IR Magnets QD0 and QF1 K. C. Wu - BNL.
Neutrino Cryogenics Requirements Meeting 25/09/2014 Day 1 review.
Process Definition of the Operation Modes for Super-FRS Magnet Testing CSCY - CrYogenic department in Common System, GSI, Darmstadt Y. Xiang, F. Wamers.
1 ESS Cryogenic regulation loops proposal  Thermal shield  Power Couplers double-wall  CM cool down  Stand by and nominal operation  CM warm up Bertrand.
GLA2011 The cryogenic systems of the LHC experiments Johan Bremer on behalf of TE/CRG, ATLAS collaboration and CMS collaboration.
MAGNET#1MAGNET#2MAGNET#3 SATELLITE VB#1 SATELLITE VB#2 SATELLITE VB#3 PRECOOLER#1PRECOOLER#2 DISTRIBUTION VALVE BOX DVB CP#1CP#3CP#2 BUFFER DEWAR LHe 5m.
Cryogenic Summary - K. C. Wu Testing D2L102 in MAGCOOLJune, 02 Difference between D2L102 and D2L101 Operating Summary Cooldown to 100 K and 6 K Test Condition.
Cryogenic Cooling Schemes for the SPL U. Wagner TE-CRG.
1 Liquid Hydrogen R&D test report CM34 – 17/10/12 S Watson P Warburton M Courthold.
Cryogenic scheme, pipes and valves dimensions U.Wagner CERN TE-CRG.
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
Status of the Marco chiller and Marco capacity analyses Bart Verlaat, Lukas Zwalinski, Maciej Osterga, Jan Godlewski MPI Munich,1 March.
GTK GAS COOLING SYSTEM Marco Statera, Vittore Carassiti, Ferruccio Petrucci, Luca Landi, Stefano Chiozzi, Manuel Bolognesi NA62 - GTK working group meeting.
GTK GAS COOLING SYSTEM Marco Statera, Vittore Carassiti, Ferruccio Petrucci, Luca Landi, Stefano Chiozzi, Manuel Bolognesi NA62 - GTK working group meeting.
8/29/07K. C. Wu - Brookhaven National Lab1 Major Components in ILC IR Hall Interchangeable Detectors.
T-6B On-Board Oxygen Generation System (OBOGS)
Refrigeration What's Refrigerated? What makes up a system?
TITLE OF THE PROJECT:- AUTOMOBILE AIR CONDITIONING AIM OF THE PROJECT:- TO STUDY ABOUT AIR CONDITIONING SYSTEM OF AN AUTOMOBILE PRESENTED BY: INAMUL.
Thomas Jefferson National Accelerator Facility Page 1 CEBAF Cryo & SRF Workshop April 3, 2014 Jonathan Creel Electrical / Cryogenics Engineer Cryogenics.
Project X Workshop - Cryogenics1 Project X CRYOGENICS Arkadiy Klebaner.
AT-ECR/C.FabreMay 31, 2007 Cryogenics for Liquid Argon Calorimeters Caroline Fabre on behalf of the ATLAS Liquid Argon Cryogenics Collaboration.
TDR Cryogenics Parameters Tom Peterson 28 September 2011.
Thermally managing high power devices using heat pipe assemblies
Heat Transfer and Refrigeration Cycle
Final Design Cryogenic and mechanical configurations
Status CO2 Cooling IBBelle: Reconnection after Belle II Roll in
How Does HNOSS Operate? Rocío Santiago Kern 20th May 2016.
Heat Transfer and Refrigeration Cycle
Z. W. Zhou, Q. Y. Zhang*, X. F. Lu, L. B. Hu and P. Zhu
Cooling down of W7-X coils with/without casing circulation
Cryogenic behavior of the cryogenic system
Marco Statera NA62 - GTK working group meeting
Proximity Cryogenics P&IDs meeting
SILICON PIXELS DETECTOR
HO Corrector Magnets: decapole test and future plans
Small Coolers for MICE MICE Collaboration Meeting RAL Michael A. Green
Lesson 24 NATURAL CIRCULATION
Cryostat design Mechanical design: Thermal screens: Specifications:
Recirculating CO2 System
Cryogenics – The Basics
Cryogenic behavior of the magnet
Cooling System.
Presentation transcript:

GTK gas coolingsystem status Marco Statera, Vittore Carassiti, Ferruccio Petrucci, Luca Landi NA62 - GTK working group meeting

OUTLINE installation gas cooling system working parameters Na62 GTK working group meeting Marco Statera1

installation three separate cooling stations two trenches are fine, three are better short lines: cheaper – lower losses installation side: Jura - Saleve 2NA62 GTK working group meeting Marco Statera

SCHEME - liquid Pro liquid is a reserve of gas fast restart time after an emergency stop SHI CH-110 coldhead (+20%) Cons needs cryogenic liquid pumping vapour (not only gas) COST cryostat about 10k€ engineering,blower and DC controller: 140k€ cold head 16k€ lines about 15 k€ delivery 9 months 3Na62 GTK working group meeting Marco Statera

SCHEME – gas only Pro More flexible gas temperature selection No liquid involved Gas selection (He or N2) Higher flow possible Cons refill by outer bottle time between emergengy stop and restart pressure 3-4 bara COST vacuum, heat exchanger and pump 70 k€ cold head 16 k€ lines about 15 k€ delivery 5 months 4Na62 GTK working group meeting Marco Statera

COST REDUCTION different suppliers engineering and design (vacuum, cryogenics, heat exchanger …) Investigate a hybrid solution 5Na62 GTK working group meeting Marco Statera

TYPICAL MEASUREMENT cooldownmeasure warm up FLOW Ta Tc Tb 6Na62 GTK working group meeting Marco Statera Nov 2010

COOLDOWN May 2011Celsius – l/min seconds manual regulation the system is sensitive to flow regulation a heater at the GTK inlet can regulate the lower temperature about 20 °C below the temperature during operation even a 100 °C gradient introduces a maximum offset of 7Na62 GTK working group meeting Marco Statera material α /K Aluminum22 Kapton20 Silicon5 Copper17 G10 – FR411

WARM UP self warm up – cooling turned off max warming speed about 40 K/h heating not required 8Na62 GTK working group meeting Marco Statera Nov 2010

emergency about 25 seconds with the valve closed: temperature rise 4 seconds power is stopped no need of very fast interlock: about 1 second 9Na62 GTK working group meeting Marco Statera May 2011

CONCLUSIONS gas cooling systems can be installed in the cavern comparison of different cooling system cost analisys of the gas cooling systems standard cooldown and warmup data and procedure shown emergency state parameters were investigated: response time ≈ 1 second Na62 GTK working group meeting Marco Statera10