Engineering perspectives on quadrants (1/2) Experience on our first quad (Higo) (2/2) Perspective on quad (Higashi) CLIC09, Oct. 12-16 T. Higo (KEK)

Slides:



Advertisements
Similar presentations
CLIC08 workshop Structure production: CERN activities and Master Schedule G. Riddone, W. Wuensch, R. Zennaro, Contributions from C. Achard, S. Atieh, V.
Advertisements

RF Cavity Module G. Gosling Dept. of Mechanical Engineering Imperial College London.
MICE RF and Coupling Coil Module Outstanding Issues Steve Virostek Lawrence Berkeley National Laboratory MICE Collaboration Meeting October 26, 2004.
5th Collaboration Meeting on X-band Accelerator Structure Design and Test Program. May 2011 Review of waveguide components development for CLIC I. Syratchev,
Bellow valve (trap&pump) Inside glove box. (Note: Ar glove box is not necessary, if you work with single crystalline organic materials like rubrene that.
PillBox Cavity Update (Button Tests) Bob Rimmer NFMCC CM University of Mississippi Jan 13, 2009.
Progress and Plan for Superconducting RF Cavity RF Group.
MICE RF Cavity Design and Fabrication Update Steve Virostek Lawrence Berkeley National Laboratory MICE Collaboration Meeting October 27, 2004.
Report from KEK High gradient study results from Nextef (+ other related activities) LCWS2011, Granada Sep. 27, 2011 T. Higo.
18/6/2007 M.Taborelli, TS-MME Structure fabrication techniques and possibilities M.Taborelli Disk structures Quadrant structures ….most of it inspired.
Status of KEK production July 11, 2008 at SLAC KEK T. Higo et al., Accelerator div. T. Takatomi et al., Mech. Eng. Center.
Status of the 201 MHz Cavity and Coupling Coil Module Steve Virostek Lawrence Berkeley National Laboratory MICE Video Conference March 10, 2004.
Safety Review: RF Issues Derun Li Absorber Safety Review December 9-10, 2003 Lawrence Berkeley National Laboratory Berkeley, CA
MICE Collaboration Meeting March 29 - April 1, CERN MICE alignment, tolerances and supports Tuesday March 30 Room Edgar Black/IIT March17-
Cell-Coupled Drift Tube Linac M. Pasini, CERN AB-RF LINAC4 Machine Advisory Committee 1 st meeting CERN January 29-30, 2008.
Status of the MuCool Cavity Prototype Steve Virostek Lawrence Berkeley National Laboratory MICE Collaboration Meeting October 21, 2005.
Vacuum, Surfaces & Coatings Group Technology Department Vacuum tests for CLIC module prototypes 6 November 2013 C. Garion2 Outline: Reminder: specification.
2 nd collaboration meeting on X-band Accelerator Structure Design and Test-Program Structure fabrication Comparative analysis of disk and quadrant manufacture.
Improvements for next parts PIMS production meeting February 2013 Rolf Wegner.
Vacuum system in the main Linacs C. Garion CERN/TE/VSC CLIC09 workshop, October.
CIEMAT CONTRIBUTION TO TBL PETS (January 2009) David Carrillo on behalf of the Accelerators Team.
201 MHz and 805 MHz Cavity Developments in MUCOOL Derun Li Center for Beam Physics Lawrence Berkeley National Laboratory Nufact 2002 Workshop, London,
Status of vacuum & interconnections of the CLIC main linac modules C. Garion TE/VSC TBMWG, 9 th November 2009.
MICE RFCC Module Update Allan DeMello Lawrence Berkeley National Laboratory MAP Winter Collaboration Meeting at JLab, Virginia February 28, 2011.
KEK activities on CLIC X-band Accelerating Structures Tsinghua Univ., March 24 T. Higo (KEK)
First TBL PETS prototype tank development D. Carrillo, E. Rodríguez, F. Toral, CIEMAT N. Chritin, S. Doebert, I. Syratchev, CERN CERN, 24/01/2008 Courtesy.
Status of RFCC-Module Development Derun Li Center for Beam Physics Lawrence Berkeley National Laboratory MICE Collaboration Meeting at INFN-LNF, Frascati,
Dec. 4, 2001 CERN-1 Hans de Vries VELO Mechanics  RF/vacuum foil  Rectangular bellow  Wake field suppressors  Cabling Summary & Outlook VELO mechanical.
International Workshop on Linear Colliders 2010 Design and fabrication update on PSI/Trieste X-band phase- space rotator structure Dmitry Gudkov 21-OCT-2010.
Cavity status; recent KEK activities : Hayano (1) STF CM-1 cavities are; MHI-014: 3-rd VT:36MV/m (finished) MHI-015: 3-rd VT: > 18.4MV/m.
Fabrication of accelerator structures for CLIC study CLIC Workshop Oct , CERN T. Higo, KEK.
BDS 11 Vacuum System for BDS [Completeness of RDR] Y. Suetsugu J. Noonan and P. Michelato Design principle Basic design Cost estimation.
10/2007 M.Taborelli, TS-MME Structure Manufacturing, Achievements and Challenges M.Taborelli -Technology -Shape accuracy -Surface quality -Assembly accuracy.
Superconducting rf test facility STF 1 Optical Inspection update at KEK Ken Watanabe ( KEK ) ILWS08 in Chicago 17-Nov-08.
1 HER Arc RF seals M. Sullivan MAC Review Oct , 2006 Status of HER Arc RF Seals M. Sullivan For the PEP-II team Machine Advisory Committee Review.
CLIC Workshop – CERN, October / 17 DC breakdown experiments for CLIC CERN, TS-MME Antoine Descoeudres, Trond Ramsvik, Sergio Calatroni, Mauro Taborelli.
ABSTRACT The Compact Linear Collider (CLIC) is currently under development at CERN as a potential multi-TeV e + e – collider. The manufacturing and assembly.
Recent High-gradient test result at KEK Linear Collider Workshop 2012 Arlington, Texas (WebEx) 25 October, 2012 Toshi Higo and X-band group of KEK.
2009/1/16-18 ILD09 Seoul 1 Notes for ILD Beam Pipe (Technical Aspect) Y. Suetsugu, KEK Parasitic loss Vacuum pressure profile Some comments for beam pipe.
1.3GHz Input Coupler for ILC
Performance of CLIC prototype accelerator structures tested at Nextef CLIC February 2014 Toshiyasu Higo (KEK)
MICE RFCC Module Update Allan DeMello Lawrence Berkeley National Laboratory MICE CM29 at RAL, UK February 17, 2011.
14-Dec-15S.Movchan Straw manufacturing and QC1 Straw manufacturing procedure and QC tape and straw parameters specification conditions of straw production:
Study Plan of Clearing Electrode at KEKB Y. Suetsugu, H. Fukuma (KEK), M. Pivi, W. Lanfa (SLAC) 2007/12/191 ILC DR Mini Work Shop (KEK) Dec.
Production Readiness Review at PNPI Chamber assembling: Main production and quality control steps 30 January 2004 – G.Alkhazov 1.Input components control.
1 Al Moretti, APC, Fermilab MAP- Winter Meeting February 28 - March 4, 2011 TJNAF Newport News, VA.
ENGINEERING DESIGN AND FABRICATION OF X-BAND ACCELERATING STRUCTURE TD24 WITH WFM Abstract To achieve high luminosity in CLIC, the accelerating structures.
Main features of PETS tank J. Calero, D. Carrillo, J.L. Gutiérrez, E. Rodríguez, F. Toral CERN, 17/10/2007 (I will review the present status of the PETS.
SKEKB Mini Work SKEKB Vacuum System – Arc Section – Contents Y.Suetsugu KEKB Vacuum Group 1.Beam Chambers 2.Pumps: Pump, Pressure,
Status report from KEK Feb. 26, 2010 T. Higo, S. Matsumoto T. Takatomi, Y. Higashi and X-band group.
Nextef results CLIC09, Oct T. Higo (KEK). Contents Quadrant high gradient test status – Initial processing and power limit – VAC characteristics.
Mechanical design and tests of the new X-band flange
CLIC09 WG4 RF Structure1 Engineering Perspectives on Quadrants (2) CLIC09 Workshop KEK Y.Higashi.
7-Sep-2011 CLIC RF Structure Development Meeting «BE/RF» TD26 WITH COMPACT COUPLER FOR CLEX (TD26 CC SiC) ENGINEERING DESIGN this structure will be used.
Status of high gradient experiments at Nextef Kazue Yokoyama, Toshiyasu Higo, Yasuo Higashi, Shuji Matsumoto, Shigeki Fukuda Accelerator Laboratory, KEK.
11/02/2005M. Alfonsi - LNF1 DETECTOR CONSTRUCTION M. Alfonsi - LNF.
Cell to cell alignment on GLC structures 24 Nov. 2014, CERN Toshi Higo (KEK) 2014/11/23CLIC Structure Review1.
Some information from Nextef For poster session in IWLC T. Higo.
CM2 Repair Status 8/13/2012 Tug Arkan 1. Latest Status After the warm end couplers were disassembled, it was decided to disassemble all the lower aluminum.
Preparation procedure and RF processining of cERL-ML power coupler at KEK Hiroshi Sakai, Takaaki Furuya, Masato Sato, Kenji Shinoe, Kensei Umemori, Kazuhiro.
2008/12/10 INFN R&D on Low Impedance Beam Chamber and Components Y. Suetsugu, for KEKB Vacuum Group Contents Introduction Beam Chamber Components Connection.
PXIE RFQ Engineering Design Steve Virostek Engineering Division Lawrence Berkeley National Laboratory April 10, 2012 Project X Collaboration
325 MHz Superconducting Spoke Cavity Coupler status. T. Khabiboulline Power Coupler design for Superconducting Spoke cavities. Originally.
LCWS11 WG4 Fully featured accelerating structure engineering design
Effort to identify the critical issues for high gradient
Review of rf structure test results
SPARC RF gun status by P. Musumeci Review committee
Tolerances: Origins, Requirements, Status and Feasibility
Disk-damped versus Quadrant-damped from engineering view point
5th X-Band Structure Collaboration Meeting
Presentation transcript:

Engineering perspectives on quadrants (1/2) Experience on our first quad (Higo) (2/2) Perspective on quad (Higashi) CLIC09, Oct T. Higo (KEK)

Contents Quadrant – Fabrication of quads – Surface treatment – Assembly of four quads – Tuning – Vacuum chamber SiC material 2CLIC092009/10/12

KEK’s version: 50 micron chamfer Made of CuZr without heat treatment. 50 micron rounding: shape with angles and bumps. Reference planes were formed by milling in a few micron level without re-chucking for shaping cells. Assembly was done within ten micron level. 3CLIC092009/10/12

Possible cause of high dark current Field enhancement due to round chamfer Simulation of field enhancement – 1.4 ~ 1.6 at radius – with gap<radius/5, step<radius/2.5 Only a few tool passes – to shape 50 micron radius – with radius tool of 2mm If three passed  tangential discontinuity by about 30 degree Can be relaxed by such as EP in future 2009/10/12-184CLIC09 Higo

Electric field enhancement in a shallow channel with round chamfer Gap (micron)Bump (micron)Emax / Enominal Calculation done by T. Abe by CST MS. Waveguide field. 2009/10/12-185CLIC09 Higo

Detailed shape at R0.05 chamfer Cell #9 Cell #10 Cell #11 Only 2~3 tool passes over R deg rounding. Not tangential connection from smooth surface degree edge emerges. Sharp edges or bumps exist at the rim. 6CLIC092009/10/12

Production of quadrant Q1-1 7CLIC092009/10/12 Green lines are ±2.5 microns. Followings shows worst part out of four measured areas along the axis. Local shape is smoothly connected.

Cleaning: no etching Alcohol bath – with ultra-sonic vibration for 5 minutes. Acetone bath twice – with ultra-sonic vibration for 5 minutes. Nitrogen blow Storage in a deccicator – Initially filled with nitrogen gas. – Storage for more than a month. 8CLIC092009/10/12

Carry and storage Edge inspection First hanging Check ball diameter Prepare next quad approach Second hanging Assembly 9CLIC092009/10/12

Fine adjustment Fixing by bolt Completion of stack Alignment checking RF setupManual adjustment before final pressing, without ball and groove mechanism. Misalignment: within ten microns. Reproducibility: a few microns. 10CLIC092009/10/12

Final alignment X Y Z C-plane INOUT Misalignment of each quadrant w.r.t. the average of four quadrants (units are in micron) 11CLIC092009/10/12

Elastic tuning with a ball being kept push 4mm stainless ball pushed by minus watch driver. Pushing by turning with Higo’s hand full force. Elastic deformation kept, meaning that the tuning pins are kept pushing the balls. 12CLIC092009/10/12

Notice: Deformed cavity wall Cell 3(×35 ) Cell 3(×100 ) Cell3 deformation : 0.053mm Cell 8(×35 ) Cell 8(×100 ) Cell8 deformation : 0.167mm Cell 10(×35 ) Cell 10(×100 ) Cell10 no tuning 13CLIC092009/10/12

Field smoothness after tuning good. 14CLIC092009/10/12

Vacuum chamber design U-tight seal (round metal gasket) VCR connector for cooling water connection Thin H-bend being vac sealed with bellows Vac evacuation from CF114 mounted on chamber with IP 70l/s and from WR90 at just 0.5m from structure 15CLIC092009/10/12

Installation into chamber 16CLIC092009/10/12

Evacuation with quad structure With quads  need baking of quad Bare chamber after bake OK 17CLIC092009/10/12

First installation to Nextef but, 1. Firstly baked without quads at ~200C  Reached 10^-5Pa 2. Quad into chamber  10^-4Pa 3. Then baked with quads ~200C  Reached 10^-6Pa 4. Moved to Nextef but the stuck gaskets prevent quad from connection to waveguide  Removed gaskets by oil-less milling with cutting flange surface  Reinstalled into chamber without baking. 18CLIC092009/10/

Installed into Nextef Nextef setup 3dB phase check Input connection 19CLIC092009/10/12

Evacuation of quad at Nextef Evacuation with TMP through CF114 Prepare IP with baking, while evacuation by TMP through ICF70 Start evacuation by IP Evacuation July 7/31 RF ON Evacuation with IP Reached 10^-6Pa with IP  Then RF-ON 20CLIC092009/10/12

Vacuum of quad Base pressure reached Pa – Nearly one order of magnitude worse than T18_Disk (a few Pa) – Taking good vacuum conductance from gauge to RF pass, vacuum level inside is estimated to be close to T18_Disk Gas activity with RF – Should carefully be studied to see what is happening inside due to RF and sometimes breakdowns – We may get some hint to understand breakdown 2009/10/12CLIC0921

Hitachi’s second try of quad fab. Hitachi engineer tried again a quad test production. It reached the similar level as those of Quad#5. Milling done with 3D milling machine but adding another rotational motion. Company engineers are interested in the quad production. They are watching our perspective. 2009/10/12CLIC0922

Conclusion to pass to Higashi’s talk First Quad by KEK was now in high power test. Many features are still in question – responsible for the poor high gradient property? However, we want to use it as our education to understand breakdown. Quad approach: – We need to establish high gradient first, – Taking mass production perspective in mind. –  Higashi 2009/10/12CLIC0923

Some information on Lossy material SiC being studied by Y. Takeuchi – Based on material for HOM absorber of KEKB 500MHz cavity SuperB chose low current/low emittance design No extra funding for higher frequency development – Tried tuning to higher frequency By changing doping amount – Mostly by two companies Covalent and Hitachi chemical 24CLIC092009/10/12

Adjustment of the permittivity of SiC ceramics Schematic Model of SiC CeramicsTwo-layer Model and Equivalent Circuit By doping Al-compound, we have tried to increase the carrier concentration in the grain. >>>>> The relaxation time (~ CdRg) will change. Y. TAKEUCHI (KEK) and M. ANDO (Covalent Materials Corporation) Y. Takeuchi (KEK) 25CLIC092009/10/12

Al : 420 ppm(wt) Relaxation time  ~1.6x sec Resistance 19 M  (1 cm) * Relaxation frequency = 1/(2  ) Al : 650 ppm(wt) Relaxation time  ~1.6x sec Resistance 0.8 M  (1 cm) Results of the doping (preliminary) Y. Takeuchi (KEK) 26CLIC092009/10/12 Covalent work in collaboration with KEK.

SiC ceramics for higher frequency produced by HITACHI CHEMICAL For KEKB ARES cavity Developed to higher frequency Y. Takeuchi (KEK) 27CLIC092009/10/12 Hitachi Chemical did try and KEK measured.

For further info on SiC Please contact Takeuchi for further info in general. You can directly contact Covalent or Hitachi Chemical, for technical info and for production capability. KEK may make for accelerator structure use, depending on the success of TD24. If more for PETS – probably better to control production process by those who make PETS with the actual production company. 2009/10/12CLIC0928