Chip Programmer Intelsteer Power Save PBI Series.

Slides:



Advertisements
Similar presentations
Automation and Drives Gliederungspunkt 10 MarCom Concept Sirius Softstarter Introduction Situation Market System / Product Sales Communication Service.
Advertisements

ABB standard drive Enhanced ACS550
Three-Phase AC machines
SV100 Open-Loop Vector VFD FV100 Closed-Loop Vector VFD 1.
Motors & Motor Starters
Induction Motor Review
Special Applications Timed shut-off function Intelsteer Power Saver.
4 key operations UP/ DOWN 、 Esc and Enter Only 3 keys are needed for the rator to adjust all the parameters Simple Esc key Chips Programmable Intelsteer.
Hydraulic Anti-Lock Braking System For Trucks, Buses and Motor Homes.
IntelSteer Power Saver PBI Series Device – Standard Internal Parameters Intelsteer Power Saver PBI Series.
A TECHNICAL PRESENTATION BY: ERIC BABSKI Controlling Electric Motors.
Fundamentals of Electric Drives: DC Drives
Direct – Current Motor Characteristics and Applications
Elec467 Power Machines & Transformers
Contactor A contactor is a relay with heavy-duty contacts to carry large amounts of current. Available either Normally Open or Normally Closed.
ET 332a Dc Motors, Generators and Energy Conversion Devices Lesson 21: Operation and Control of Dc Motors 1 Lesson a.pptx.
E2 Motors and Motor Starting
AC MOTOR INDUCTION MOTOR.
Install IntelSteer Power Saver Device
SISTEMA Example One. Schneider Electric – Sistema Example 1 – June Example 1: Start/Stop Facility with Emergency Stop Device Circuit Diagram.
Troubleshooting Electric Control Devices
Industrial Machine Control
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
1 Institute of Mechatronics and Information Systems Control and Driving Systems.
HVAC214 - Oil Electrical Motors Part 1.
Chips Programmable Main menu – special applications.
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
Lecture 10 DC Motors. Electric Braking Sometimes it is desirable to stop a d.c. motor quickly. This may be necessary in case of emergency or to save time.
3-Phase Submersible Motor Control
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
New generation inverters
School of Electrical Systems Engineering ABD RAHIM 2008.
UNIT 17: TYPES OF ELECTRIC MOTORS
Electricity. Menu AC & DC Household Plugs & Fuses Power & Fuses.
Wholesale Medium Voltage Drives
REDA Production Systems
Welcome Welcome to GEMCO CONTROLS LIMITED
Elements of Electrical Design HASMUKH GOSWAMI COLLEGE OF ENGINEERING
ACTIVE LEARNING ASSIGNMENT TOPIC NAME :- DC MOTOR STARTERS ELEMENTS OF ELECTRICAL DESIGN ( ) AY Course co-ordinator:- SAMIR B PATEL PREPARED.
INTRODUCTION A 3-phase induction motor cannot be operated at variable speed. 1-phase induction motor is not self starting. Thus, A.C. commutator motors.
1 School of Electrical Systems Engineering ABD RAHIM 2008 EET421 Power Electronic Drives – Induction Motor & drives Abdul Rahim Abdul Razak.
Three-Phase AC machines
ELECTRICAL DEPARTMENT ELEMENT OF ELECTRIC DESIGN
Energy Efficient Motors and Variable Speed Drives
Components Motors and Generators.
Components Motors and Generators.
DC Generators.
Controlled-Rectifier Fed Drive
Today we are going to discuss about,
Controlled-Rectifier Fed Drive
© 2004 Refrigeration Training Services - Refrigeration Categories v1.1
ELECTRONIC & TELECOMMUNICATION DEPARTMENT.
Three-Phase AC machines
PRESENTED BY:AMOD SHAKYA. Power Circuit –connectoin with motor using contactor Control Circuit-using switch make a holding circuit.
8. Braking of Electric Machines
Subject : Electronic Machines
Synchronous Motors and Generators
What is Braking? The term braking comes from the term brake. We know that brake is an equipment to reduce the speed of any moving or rotating equipment,
Motor Drive Prof. Ali Keyhani. Modern Variable Speed System A modern variable speed system has four components: 1. Electric Motor 2. Power Converter -
Energy Conversion and Transport George G. Karady & Keith Holbert
Electric braking Powerpoint presentation by:- Poonam sharma
SINGLE PHASE INDUCTION MOTOR.
Braking of Three Phase IM
Presentation transcript:

Chip Programmer Intelsteer Power Save PBI Series

Chip Programmer Main Menu- Basic Applications The chip programmer is inbuilt with 13 different kinds of basic application setups Including conveyer belt 、 compressor 、 stone crusher 、 and so on ….

Chip Programmer Main Menu- Basic Applications Stone crusher-provided with a function of full-torque start Line voltage 25% 80% 100% Time start 1 Optimization start2 Dwell Time Optimization Dwell Time

Chip Programmer Basic software reboot The independent soft start parameters can be adjusted by the chip programmer.

Chip Programmer Main Menu- Basic Soft Reboot Basic voltage—voltage value at the time of start From 25 to 80%V (may increase gradually at a ratio of 1%) Directly start torque from 6 to 64% (6)25% (64)80% pedestal voltage start torque

Start Time seconds (may increase gradually at 1 sec. value) Time (6)25% (64)80% pedestal voltage start torque % Chip Programmer Main Menu- Basic Soft Reboot

Kick start level and time Directly start torque with line voltage from 25 to 80% or from 6 to 64%. 0.1 to 25 seconds (may increase gradually at 0.1 sec. value (6)25% (64)80% Kick start voltage level Kick start torque % (36)60% 1

Chip Programmer Main Menu- Basic Soft Reboot Current limitation level and time Directly start current from 25 to 80% 0 to 255 seconds (may increase gradually at 0.1 sec. value) Current limitation Time Start current level % 80% 100% Motor Voltage Start Time

Chip Programmer Main Menu- Basic Soft Reboot Soft stop function Step-type stop function Reverse Torque Braking

Chip Programmer Main Menu- Basic Soft Reboot Soft stop function Soft stop time has effect merely on high electrostatic frictional load (e.g. pipeline centrifugal water pump). The principle of operation is, on the basis on the gradual reduction of terminal voltage of motors, controlling motor torque to allow for the deceleration of motors in a controlled state with their own loads.

Chip Programmer Main Menu- Basic Soft Reboot A =Step-type stop voltage level (may be adjusted from 100 to 40% at an increase/decrease ratio of 1%) B = Step-type stop time (may be adjusted from 0 to 255 seconds at an increase/decrease ratio of 1 second) C = Step-type stop power dump level (may be adjusted from 30 to 50% at an increase/decrease ratio of 1%) (64)80% 100% Step-type stop function (6)25% Voltage Motor torque A B C

Actual working conditions of water pump after the application of step-type stop function Process start running stop Time StartSoft StartStopSoft Stop Chip Programmer Main Menu- Basic Soft Reboot

PLUG BRAKING (REVERSE TORQUE BRAKING) Line voltage 6 25% 80% 100% Braking torque% time Contactors reverse 64 Forward Optimize Braking Time

Chip Programmer Main Menu- Basic Soft Reboot A = braking torque ( may be increased gradually from 6 to 64% at a ratio of 1%) B = braking time ( may be increased gradually from 0 to 255 seconds with a value of 1 second) PLUG BRAKING (REVERSE TORQUE BRAKING) 6 25% 80% 100% Braking torque time Contactors Reverse 64 Forward Optimize Braking Time A B

U V W L1 L2 L3 EARTH K1 FAN (If Fitted) 3 Phase Supply U W V K2 Motor Overload Semiconductor Fuses PowerbossPBI series Line of main power supply * Normally Closed Contact from optional speed sensing relay*. Intelsteer power save PBI series TB V/230V Control Supply K1 Start TB RL2 FAN (if fitted Emergency Stop O/L K2 K1 For K1 Brake * TB2 RL Line of control circuit REVERSE TORQUE BRAKING Chip Programmer Main Menu- Basic Soft Reboot

Relay RL1 and RL2 can be set in any of the following states: Operational relay Relay with maximal rotate speed Fault relay

Chip Programmer Main Menu- Basic Soft Reboot Shifting function of non - arcing touch After the formation of start loop, “IntelSteer electric appliance” can provide a buffering time before current runs through the motor and make the main contactor (K1) actuate under a zero-current condition. It may increase or decrease from 0.1 to 25.5 seconds at a ratio of 0.1 second.