Codan 5700 Series C-Band Transceiver Technical Overview.

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

CommentaryVideo Hi, my name is Edward Guillergan and I’m one of AMETEK Programmable Power’s Applications Engineers. I’m here to provide an overview of.
Lecture: 04 Engineer ASAD MEHMOOD. Contents ZXC10-BTSB Solution ZXC10-BTSB AE BDS RFS PWS.
Orion Telecom Networks Inc VCL-E3 OLTE 34Mbps Optical Line Transmission Equipment Slide 1 Updated : January 1st, , Avenue of Fountains,
Valiant Communications Limited Slide 1 Updated : January, 2006 V aliant C ommunications L imited Telecom Transmission Solutions VCL-E3 OLTE 34Mbps.
Motorcycle product sheets
GS3055-I GSM Universal Wireless Alarm Communicator
MODULAR SMPS POWER PLANT
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
UPS H series introduction UPS training June 2006 Markus Schwab.
Polar Loop Transmitter T. Sowlati, D. Rozenblit, R. Pullela, M. Damgaard, E. McCarthy, D. Koh, D. Ripley, F. Balteanu, I. Gheorghe.
Chapter 8 Output Modules.
RF Wakeup Sensor – On-Demand Wakeup for Zero Idle Listening and Zero Sleep Delay.
ESTeem Training Class Antenna Fundamentals. Decibels (dB) Used for all mathematical calculations in the radio world. – dB is a logarithmic number dB =10.
Safecom INGRESS GATE technology (Patent p) UPSTREAM RF & INGRESS NOISE BLOCKER Solving the “Funneling Effect” at HFC & RFoG networks.
WP06_AntennaIF. WP06_AntennaIF 3 principal modules switch amplifier (= ATA ‘PAM’) –includes attenuators (0-60 dB), power detector, and bias tee for the.
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
Codan L-Band Block Upconverter (BUC) System
Codan C-Band & Ku-Band IF Transceiver Systems
Lesson 9: Electrical Components
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
MC-1610MR / MC-1610MR48 16-Slot Managed Media Converter Chassis Copyright © PLANET Technology Corporation. All rights reserved.
An Enhanced/Permanent Amateur Radio Station Proposal L. McFadin, W5DID K. Banke N6IZW
1 P ROTEUS AMT Adaptive Modulation Transport. 2 Product Overview AMT-Series Indoor Unit Outdoor Unit L-Series Indoor Unit.
1 Digital Voltage Transducer family DV from 1200 to 4200 V RMS DVL from 50 to 2000 V RMS.
POWER PLANT USED IN TELECOM
Smart transmitters.
Datron World Communications Inc. RT7000 HF TRANSCEIVER FIELD MAINTENANCE PROCEDURES.
Zach Molden Shamlan Al-Roomi NJ Purevsuren Raied Farash Aadiel Rizvi C ritical D esign R eview.
Modular Inverter.
Automatic UpLink Power Control System. UpLink Power Controller (principle of operation) ‘Rain Fade’ affects both transmitted signal and Beacon signal.
Codan L-Band Block Upconverter (BUC) System HiSeasNet Training Course SIO, August 2009.
Acquisition Crate Design BI Technical Board 26 August 2011 Beam Loss Monitoring Section William Vigano’ 26 August
CUE – Make Any Pump an E-Pump
Power Supply The basic function of power supply is to convert the AC supplies available at wall socket, that which is unusable by the computer. The SMPS.
Submitted by:.  Project overview  Block diagram  Power supply  Microcontroller  MAX232 & DB9 Connector  Relay  Relay driver  Software requirements.
PROJECT ON FAULT ANALYSIS AND DETECTION GUIDED BY:: SUBMITTED BY:- MS. SHUBRA GOEL.
Rectifier A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which.
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
TRANSMISSION LINE MULTIPLE FAULT DETECTION AND INDICATION TO EB
RF Presentation.
USING TV REMOTE AS A CORDLESS MOUSE FOR THE COMPUTER
CORDLESS MOUSE FEATURES BY TV REMOTE USING PIC MICROCONTROLLER
Application Case Study Christmas Lights Controller
Codan 5700 Series C-Band Transceiver
Codan 5700 Series C-Band Transceiver
Cosmic Microwave Technology, Inc.
NV Series Transmitters Theory of Operation
System Network Structure
SCADA for Remote Industrial Plant
PC Mouse operated Electrical Load Control Using VB Application
Switching DC Power Supplies
Redundancy Switching Components
FEEDER PROTECTION UNIT
High Performance Low Cost Low Lost Wireless DC Motor Speed Control
TB8100 Technical Training July 2005
Safecom INGRESS GATE technology (US,EP Patent) 28dB UPSTREAM RF & INGRESS NOISE BLOCKER Solving the “Funneling Effect” at HFC & RFoG networks Allows carrier.
Codan 5700 Series C-Band Transceiver
CECOM LAR Tropo Operation Course
AM-7027 Up Converter-Amplifier
AM-7026 Down Converter-Receiver
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
SN-553 Frequency Synthesizer
Codan 5700 Series C-Band Transceiver
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
Budget *Cost divided evenly between Fuel Cell and Fly Wheel Groups.
Presentation transcript:

Codan 5700 Series C-Band Transceiver Technical Overview

5700 Series C-Band Transceiver Components type 5700 Converter Module SSPA types – W – W – W – W – W – W –5712H - 120W LNA & TRF type 5582 Power Supply Units

C-Band Transceiver Block Diagram LNA SSPA Up/Down Converter Power Supply AC Mains Antenna TRF Transmit IF Input (70/140MHz) OMT Receive IF Output (70/140MHz) Monitor & Control Tx RF (6GHz) Rx RF (4GHz)+ LNA Pwr SSPA Pwr & Control 48V DC Power

HPA Transceiver Block Diagram LNA SSPA Up/Down Converter AC Mains Antenna TRF Transmit IF Input (70/140MHz) OMT Receive IF Output (70/140MHz) Monitor & Control Tx RF (6GHz) Rx RF (4GHz)+ LNA Pwr SSPA Control 48V DC Power

C-Band Converter Module –Not on CE converters

C-Band Converter Module Transmit Side Receive Side

IF Paths Tx IF input attenuator –25dB typical range, 1 dB steps. –10dB gain from Tx IF input to Tx RF output of converter at attenuator setting of 0dB. Rx IF output attenuator –25dB typical range, 1 dB steps. –45dB gain from Rx RF input to Rx IF output of converter at attenuator setting of 0dB. Tx IF switch - controlled by: –Warm-up timer

Tx IF Path Cable Compensation No longer available with CE market converters Cable Compensation –Provides up to 1.2dB boost (70 MHz) or 2.5dB boost (140MHz) in 16 steps –Suits over 120m (400ft) of low loss Belden 9913 coax –Ideal for DAMA systems - constant EIRP across entire IF band

Tx IF Path Temperature Compensation Temperature Compensation –Compensates for gain variations of SSPA and Converter –Selectable for 5W, 10W or higher SSPA’s (via SPT5, 6 or 7) –±1.0dB level stability over -40 o C to +55 o C –Look-up tables in EPROM –Uses temperature sensors in SSPA and Converter

Synthesisers All oscillators locked to 10MHz oven controlled reference 10MHz Reference Warm-up timer –5-14 minute warm-up from cold switch-on (14 mins. at -40C !) –30 second warm-up if power interrupted momentarily –Timer Over-ride RS232 (SRO1) Allows transmission immediately from switch-on Warm-Up LED flashes Beware frequency accuracy! SHF oscillator signals: Up and Down paths –Fixed 2225 MHz offset for single synthesiser models only –Step size 1MHz in both single & dual synthesiser models

LNA Connections LNA power source is DIP switch Selectable (LNA+15V) LNA Power via Rx RF input –LNA alarm and voltage shut down if >250mA –LNA alarm if <50mA or short circuited –Take care when testing at this input (turn off DC or use DC block) LNA Power via separate connector –Current limited (max 400 mA) –LNA alarm relay contact input

SSPA Connections Low Power SSPA Interface –48V DC - via fuse in Converter –SSPA temperature sensor for gain compensation –SSPA Fail –SSPA over temperature alarm –Fan Supply (+12V) High Power SSPA Interface –110/220V AC Mains Input –SSPA Fail –48V DC to Converter –SSPA over temperature alarm Fan Supply –Converter monitors current from fan to detect fan fault –Fault monitoring can be disabled (SFE0) for SSPA’s without a fan –Not available with high power SSPAs (self-monitoring by SSPA)

SSPA Block Diagram

Low Power SSPA (1) N-connector or Waveguide output options Internal input isolator for good input VSWR Internal output isolator for protection and good O/P VSWR High system gain: 74dB (10W to 40W SSPA’s) nominal Operates from 48V DC (fully floating) –All bias supplies are generated internally Fan supply provided separately by Converter Module Internal fault monitoring of GaAs FET bias conditions Automatic shut-down if: –Bias fault detected when SSPA on - needs to be manually reset –SSPA case temperature is >75 o C, automatically resets when SSPA cools down

Low Power SSPA (2) Two temperature sensors: –Over Temperature shut-down –Gain v Temperature compensation (in Converter) High MTBF fan standard on10W, 20W, 30W and 40W SSPA’s 5W SSPA’s are convection cooled - no fan Maintenance –Check heatsink fins for obstructions (webs, nests, insects etc.) –Clean heatsink to remove dust, dirt, grime etc. –Recommendation - check at least once per year

High Power SSPA Available in 60W and 120W Completely sealed assembly WR137 waveguide output Internal Temperature compensation Full monitor & control from 5700 Up/Down Converter DC power supplied to the Up/Down Converter from SSPA SSPA’s can also be operated in a stand alone configuration via front panel controls or serial commands

5582 Mains Power Supply Switch Selectable operation from 115V AC or 230V AC -15%/+20% Transceiver uses wide input range DC-DC converters –Provide low power consumption –High efficiency over full 37V to 76V range Simple design ensures high reliability. –toroidal power transformer and bridge rectifier combination

Transceiver Controls Power –Off - All circuits off –Stand-by - Only reference oscillator and microprocessor on –On - Operational mode SSPA –Inhibit SSPA cannot be turned on remotely (Serial or Control Input) –Remote SSPA on only if turned on remotely (Serial or Control Input) –Activate SSPA on unless inhibited remotely (Serial or Control Input) DIP Switches

Front Panel Indicators Power –Stand-by - Only reference oscillator and microprocessor on –On - Operational mode –Warm-Up - In warm-up mode, flashes if Timer Override selected SSPA –SSPA On - SSPA on! Fault –Conv One or more phase locked loops in the Converter are unlocked –LNA LNA fault detected (current sense at Rx RF input or fault input) –SSPA SSPA fault (only detected when SSPA is activated) –Temp SSPA case temperature too high –Fan Fan not operating or too slow (low power transceivers only)