13.01.2005A. Bamberger1 Experimental study of double GEM readout using MediPix2 chip A. Bamberger, M. Debatin, J. Ludwig, M. Titov, N. Vlasov.

Slides:



Advertisements
Similar presentations
GEM Chambers at BNL The detector from CERN, can be configured with up to 4 GEMs The detector for pad readout and drift studies, 2 GEM maximum.
Advertisements

Status of test beam data analysis … with emphasis on resistive coating studies Progress and questions 1Meeting at CEA Saclay, 25 Jan 2010Jörg Wotschack,
Present Status of GEM Detector Development for Position Counter 1.Introduction 2.GEM 3.Readout Board 4.Fabrication Test 5.Large GEM 6.Readout Electronics.
1 MUON TRACKER FOR CBM experiment Murthy S. Ganti, VEC Centre Detector Choice.
Atsuhiko Ochi Kobe University 4/10/ th RD51 collaboration meeting.
Micro MEsh GASeous Detectors (MicroMegas)
Maximilien Chefdeville NIKHEF, Amsterdam RD51, Amsterdam 17/04/2008
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Micromegas detectors for the CLAS12 central tracker Brahim Moreno (for the Saclay group) CLAS12 technical workshop 03/17/ 2010 Jefferson lab Update on.
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
1 Pixel Readout of GEMs Motivation The Setup Results Next Steps A. Bamberger, K. Desch, J. Ludwig, M. Titov, U. Renz, N. Vlasov, P. Wienemann, A. Zwerger.
GEM DHCAL Simulation Studies J. Yu* Univ. of Texas at Arlington ALCW, July 15, 2003 Cornell University (*on behalf of the UTA team; S. Habib, V. Kaushik,
Rate and Gain Measurements of the 1-m long GEM detector Aiwu Zhang EIC tracking R&D weekly meeting.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Gain measurements of Triple Gas Electron Multiplier (GEM) detector with zigzag readout strips V. BHOPATKAR, E. ESPOSITO, E. HANSEN, J. TWIGGER M. HOHLMANN.
Sept. 24, Status of GEM DHCAL Jae Yu For GEM-TGEM/DHCAL Group Sept. 24, 2010 CALICE Collaboration Meeting Univ. Hassan II, Casablanca Introduction.
Measurement of gas gain fluctuations M. Chefdeville, LAPP, Annecy TPC Jamboree, Orsay, 12/05/2009.
C.Shalem et al, IEEE 2004, Rome, October 18 R. Chechik et al. ________________RICH2004_____________ Playa del Carmen, Mexico 1 Thick GEM-like multipliers:
Chamber parameters that we can modify and that affect the rising time Number of ionisation clusters produced in the drift gap: Poisson Distribution Probability.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Chevron / Zigzag Pad Designs for Gas Trackers
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Yosuke Watanabe….. University of Tokyo, RIKEN A, KEK C, Development of a GEM tracker for E16 J-PARC 1 Thanks to ???????????
Test Beam the μ-RWELL Test Beam the μ-RWELL G. Bencivenni (a), R. de Oliveira (b), M. Gatta (a), G. Felici (a), G. Morello (a), M. Poli Lener (a) (a),
Geant4 Simulation of Neutrons interaction with GEM-foil and gas Gabriele Croci, Matteo Alfonsi, Serge Duarte Pinto, Leszek Ropelewski, Marco Villa (CERN)
Update on TPC R&D C. Woody BNL DC Upgrades Meeting October 9, 2003.
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
21 April 2004LCWS 2004 Paris1 Readout of a TPC using the Medipix2 CMOS pixel sensor (detection of single electrons on a direct pixel segmented anode) NIKHEF:
TPC PAD Optimization Yukihiro Kato (Kinki Univ.) 1.Motivation 2.Simple Monte Carlo simulation 3.PAD response 4.PAD response for two tracks 5.Summary &
Timepix at NIKHEFMedipix meeting, CERN – Some recents results at NIKHEF M. Chefdeville, E. Bilevych, H. van de Graaf, J. Timmermans D. Attié,
5 th RD51 meeting (WG1) 25 May 2009 Atsuhiko Ochi ( Kobe University )
F.Murtas1IMAGEM DDG GEM technology for X-ray and Gamma imaging IMAGEM l Detector setup l First results on X-ray imaging l First results on Gamma ray imaging.
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
1 IBF in aligned, misaligned and FLOWER THGEMs The IBF problem Standard THGEM configuration COBRA and extra electrode Misaligned holes FLOWER THGEM solution.
Preliminary results of a detailed study on the discharge probability for a triple-GEM detector at PSI G. Bencivenni, A. Cardini, P. de Simone, F. Murtas.
M. Bianco On behalf of the ATLAS Collaboration
Development of Digital Hadron Calorimeter Using GEM Shahnoor Habib For HEP Group, UT Arlington Oct. 12, 2002 TSAPS Fall ’02, UT Brownsville Simulation.
1 Update on Silicon Pixel Readout for a TPC at NIKHEF LCWS08 - Chicago 19 Nov 2008 Jan Timmermans NIKHEF.
Snowmass, August, 2005P. Colas - InGrid1 M. Chefdeville a, P. Colas b, Y. Giomataris b, H. van der Graaf a, E.H.M.Heijne c, S.van der Putten a, C. Salm.
TPC/HBD R&D at BNL Craig Woody BNL Mini Workshop on PHENIX Upgrade Plans August 6, 2002.
1 The pixel readout of TPCs Max Chefdeville, NIKHEF, Amsterdam.
Digital Calorimetry using GEM technology Andy White for UTA group (A. Brandt, K. De, S. Habib, V. Kaushik, J. Li, M. Sosebee, Jae Yu) U.C. Santa Cruz 6/28/2002.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
Construction and beam test analysis of GE1/1 prototype III gaseous electron multiplier (GEM) detector V. BHOPATKAR, E. HANSEN, M. HOHLMANN, M. PHIPPS,
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
GD AND GD2O3 COATINGS AS NEUTRON CONVERTERS Dorothea Pfeiffer
T. Zerguerras- RD51 WG Meeting- CERN - February Single-electron response and energy resolution of a Micromegas detector T. Zerguerras *, B.
Single GEM Measurement Matteo Alfonsi,Gabriele Croci and Bat-El Pinchasik June 25 th 2008 GDD Meeting 1.
The digital TPC: the ultimate resolution P. Colas GridPix: integrated Timepix chips with a Micromegas mesh.
Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation Josef Uher a,b, Jan Jakubek c a CSIRO.
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
Performances of a GEM-based TPC prototype for the AMADEUS experiment Outline: GEM-TPC in AMADEUS experiment; Prototype design & construction; GEM: principle.
On behalf of the LCTPC collaboration -Uwe Renz- University of Freiburg Albert-Ludwigs- University Freiburg Physics Department.
Thick-GEM sampling element for DHCAL: First beam tests & more
Larger Pixels, New Insights
some thoughts on charging-up effects
Saikat Biswas, A. Abuhoza, U. Frankenfeld, C. Garabatos,
Single GEM Measurement
Digital Calorimetry using GEM technology Andy White for UTA group
Development of Hard X-ray Detector with GEM
Numerical simulations on single mask conical GEMs
Numerical simulations on single mask conical GEMs
PHOTON DETECTION AND LOCALIZATION WITH THE
MWPC’s, GEM’s or Micromegas for AD transfer and experimental lines
Why silicon detectors? Main characteristics of silicon detectors:
Gain measurements of Chromium GEM foils
A DLC μRWELL with 2-D Readout
Presentation transcript:

A. Bamberger1 Experimental study of double GEM readout using MediPix2 chip A. Bamberger, M. Debatin, J. Ludwig, M. Titov, N. Vlasov

A. Bamberger2 Typical geometry: 5 µm Cu on 50 µm Kapton 70 µm holes at 140 mm pitch Thin metal-coated polymer foil chemically pierced by a high density of holes (technology developed at CERN) F. Sauli, Nucl. Instrum. Methods A386(1997)531 F. Sauli,

A. Bamberger3 Advantages of GEM DRIFT TRANSFER positive ion feed back minimized high rates small rate of discharges for highly ionising particles...see later F. Sauli, 2002 IEEE Proceedings

A. Bamberger4 Properties gas amplification up to 6000 easily achievable with Ar/CO 2 sufficient for min. ionizing particles in gas thicknesses of few mm S1S2S3 S4 Induction gap e - I+I+

A. Bamberger5 Comparison µMEGAS and GEM replottet from NIM A 424 (1999) 321, NIM A 479 (2002) 294 Discharge probability with α-particles Spatial resolution in laboratory tests µMEGAS: 15 µm GEM: 40 µm BUT: many orders of magnitude NIM A 477 (2002) 23 NIM A 425 (1999) 262

A. Bamberger6 Double GEM 10·10 cm² 28 channels readout electronics resistive chain for HV <4000 V semitransparent drift electrode

A. Bamberger7 Some features of the apparatus all essential elements within the gas tight box: compact, easy handling i.e. tilting is possible Noise reduction due to short leads breaking gas volume/flow for changes turned out to be an affordable disadvantage (recovery within a few hours) Multi electrode analog readout (L3 muon amplifiers 7x4): important for checking gas gain

A. Bamberger8 Overall view pocket for MediPix2 board and cable

A. Bamberger9 Double GEM drif t elektrode readout elektrode GEM 1 GEM2 thickness of drift field 6 mm transfer gap 2 mm induction gap 2 mm resistors for protection ΔV GEM = 350 – 400 V, E D, E T, E I ~ 2.5 kV/cm subject to further optimisation Gas: Ar/CO 2

A. Bamberger10 Homogeneity and energy resolution for 55 Fe photons homogeneity < ±5% energy resolution of photo- electrons of 5.9 keV: FWHM 28% strip readout

A. Bamberger11 New readout electrode configuration with 2x2 cm 2 before after movie shows 4x4 matrix with source HCAL readout !

A. Bamberger12 Inserting MediPix2 into the GEM stack gap for separation of electrodes crosses MediPix2

A. Bamberger13 Close-up of the arrangement surface of MediPix2 level with readout plane „ring“-like electrode helps to detect possible discharges near MediPix2 due to cross talk, „dummy“ MediPix2 with bonds showed no obvious discharging up to 4000 V, E ind = 3.5 kV/cm readout of MediPix2 normal functioning over many hours

A. Bamberger14 Readout with MUROS2 the parameters: lower threshold between e - upper threshold ~ 10 times higher HV 3900 V, 410 V across GEM Collimated 55 Fe source used: 4 mm opening at a distance of 35 mm source colli- mator MediPix2

A. Bamberger15 Short term shot of 55 Fe photons 14 mm estimates blob size: 10 x10 pixles = 550x550 µm 2 at gain ~

A. Bamberger s exposed sample and displacement of colim. source structure of joint between GEM electrodes seen source with collimator moved by 2 mm

A. Bamberger17 MediPix2 exposed 30 min to source w/o collimator: Boundary of GEM electrodes steep slopes

A. Bamberger18 Some considerations for the resolution Basics: 1.transverse diffusion of Ar/CO2: μm/cm 2.size of energy deposition of 5.9 keV photon 300 – 500 μm 3.defocussing effect GEMs Comments: drift space is 6 mm cone like, slanted tracks reveal 1.) dispersion of edge due to electrode boundary reveals 3.) (two bounderies of the doube GEM setup involved !) the „hit over threshold“ feature complicates the disentangling 7 mm no source

A. Bamberger19 Further investigations oberservation of min. ion. tracks quantify broadening due to drift volume use 50µm pitched GEMs reduce transfer and induction gap (1 mm), (are bonding loops above the chip a problem?) use gas mixtures with other nobel gasses

A. Bamberger20 Consideration for low photon energy spectroscopy: Conversion in gas or in Si at low energies (few keV) signal/noise dominated either by statistical fluctuations of primary clusters (GEM/μMEGAS) or by the „baseline“ fluctuation (Si converter with coupled electronics like MediPix) σ/N = 0.13 (5.9/E) 0.5 for double GEM σ/N = 200/1639 (5.9/E) for Si (σ = 200 e - ) break-even-energy at 5.3 keV Therefore it is favorable to use gas based amplifiers below a few keV

A. Bamberger21 Summary extremely robust operation of GEMs (no faulty GEM, or visible change of hole during operation during 2 month observed) HV-stable condition for operation of a „naked“ MediPix2 (~week) with a double GEM. No broken MediPix sofar! acurate position resolution seems to be achieveable

A. Bamberger22 The effort would be in vain without the help of F. Sauli M. Campbell E. Heijne X. Llopart A. Zwerger MANY THANKS !