Des Places Residence Hall Duquesne University Pittsburgh, PA Peter Edwards – Mechanical Option Advisor - Dustin Eplee Des Places Residence Hall Senior.

Slides:



Advertisements
Similar presentations
New York Life Building 20 West Ninth Street Mike Thome Hoss & Brown.
Advertisements

Heating, Ventilating, and Air-Conditioning
DOUG BOSWELL MECHANICAL OPTION APRIL 16, 2008 Temple University Tyler School of Art.
Kevin Edstrom Mechanical Option 2011 Senior Thesis April 12 th, 2011 Georgetown University New Science Center Washington, DC.
Technology in Architecture Lecture 10 Mechanical Systems Lecture 10 Mechanical Systems.
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Chilled Beam Presentation
STEM Center Delaware County Community College – Media, PA Thesis Final Presentation Dan Saxton Mechanical Option.
Coppin State University Physical Education Complex Kaylee Damico – Mechanical Option April 12 th, 2011 Presentation Outline Project Team Project Overview.
Presentation Outline Introduction CHP Analysis Electrical Analysis Acoustical Analysis Thermal Storage Analysis System Optimization Analysis Conclusion.
Solar Energy Technology for Commercial Facilities John Archibald American Solar, Inc. Association of Energy Engineers Baltimore Chapter.
Integration of Mechanical System Redesign Geothermal Heat Pump Redesign Wesley S. Lawson Architectural Engineering Mechanical Option Pennsylvania State.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Bowie State University Fine and Performing Arts Center Zachary Lippert Faculty Advisor: Dr. Stephen Treado.
Jamil Ibrahim Establishment Building Integration Thermal Collector BITC By Engineer Khaled Jazzar WEBCO sarl June 2014.
The Edward St. John Student Center Zachary Haupt Faculty Advisor: Dr. William Bahnfleth 11 April 2011.
Solar Options The “Greening” of Local Communities.
BENTLEYVILLE, PENNSYLVANIA KYLE COURTNEY | MECHANICAL OPTION | DUSTIN EPLEE.
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
North Pocono High School
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
William H. Gates Hall University of Washington School of Law Katie Jenkins The Pennsylvania State University Architectural Engineering Lighting/Electrical.
Presentation Outline Introduction System Optimization Analysis Acoustical Breadth Conclusion Acknowledgements Questions Thesis Final Presentation Army.
SENIOR THESIS PRESENTATION An Evaluation of Water-Side Economics & Emissions Sinai Hospital South Tower Vertical Expansion 2401 W. Belvedere Ave. | Baltimore,
The New RLPS Architects Office Building Lancaster, PA Brice Ohl – Mechanical Option Presented on 4/10/13.
SENIOR THESIS PRESENTATION
City of Hope Amini Medical Center Christopher Bratz Pennsylvania State University Architectural Engineering Mechanical Option Faculty Advisor: Dr. Jelena.
Ray & Joan Kroc Corps Community Center Mathias Kehoe | Mechanical Option April 09, 2012.
University Ridge at E ast Stroudsburg University Matthew Carr Spring 2007 Mechanical Option Faculty Advisor: Dr. Freihaut.
5.3 Essential Questions What are the first and second laws of thermodynamics? How does an internal combustion engine work? How does a refrigerator work?
VIMS Seawater Research Laboratory Dan DiCriscio AE Senior Thesis Mechanical Option 2007.
Tri-Valley Jr./Sr. High School Hegins, PA Senior Thesis, Spring 2004 Studying The Feasibility of a Dedicated Outdoor Air System.
Architectural Engineering Senior Thesis Mechanical System Redesign Saint Joseph Medical Center Chris Nicolais.
Presentation Outline Project Background Project Overview Industry Research: AIA 2030 Challenge and It’s Significance in Renovations Breadth #1: Redesign.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
APPELL LIFE SCIENCES York College of Pennsylvania Joshua Martz | Dr. Srebric | April 11, 2011 Image Courtesy of RLPS, Ltd.
University of Maryland’s Gossett Field House College Park, MD Jason Borowski Architectural Engineering Mechanical Option Pennsylvania State University.
The Sunshine Elementary School Redesign Proposal Pennsylvania State University AE Senior Thesis Nicholas Scheib Mechanical Option- IP.
Jonathon Gridley Senior Thesis – Spring 2007 Mechanical Option Energy Efficient Mechanical System Alternatives South Jefferson High School S OUTH J EFFERSON.
Greenbriar East Elementary School Fairfax, Virginia Michelle L. Siano Mechanical Option Spring 2005 Senior Thesis.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Malory J. Faust ∙ Mechanical Option ∙ Senior Thesis 2007.
Geothermal. Defining “Geothermal” Energy Dictionary definition – Relating to the internal heat of the earth The Earth acts as a giant solar collector,
Twin Rivers Elementary/Intermediate of McKeesport Area School District Tessa Bauman Mechanical Option Technical Consultant: Laura Miller 1600 Cornell St.,
BUILDING: LOCATION: SIZE: OCCUPANT: ARCHITECT: ENGINEERS: St. Francis Friary Hanceville, Alabama 59,900 square feet, 2 floors above grade Archdiocese.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
The New Student Housing Building at The Mount St. Mary’s University Emmitsburg, Maryland Erik Shearer Mechanical Option Advisor: Dr. Srebric Spring 2007.
NOLAN JAMES AMOS Dr. William Bahnfleth, Faculty Consultant architectural engineering senior thesis mechanical option PHOENIXVILLE EARLY LEARNING CENTER.
Manoa Elementary School Amanda Cronauer Faculty Advisor: Dr. William Bahnfleth 14 April 2010.
Michael Reilly, Jr. – Mechanical Option Advisor – James Freihaut, PhD & Dustin Eplee The Pennsylvania State University Nassau Community College Life Sciences.
Final Report on renewable energy feasibility for the Bridgeport Indian Colony Prepared by Josiah Johnston Renewable and Appropriate Energy Lab University.
The key to comfort and reduced fuel use for all heating and cooling The key to comfort and reduced fuel use for all heating and cooling.
Costs and Benefits of a Solar-Assisted Hot Water System Carl D
Grunenwald Science and Technology Building
Thermal Energy Storage
Section 3: Using Thermal Energy
5.3 notes What are the first and second laws of thermodynamics?
Energy Efficiency in District Coiling System
Biobehavioral Health Building, University Park, PA
LONGWOOD AT OAKMONT HEALTHCARE CENTER
The Ed Roberts Campus Berkeley, CA Introduction Existing Systems
Senior Thesis Presentation
Adding Zones to Existing Systems
Architectural Engineering, The Pennsylvania State University
The key to comfort and reduced fuel use for all heating and cooling
FBE03: Building Construction & Science
Technology in Architecture
Tri-Valley Jr./Sr. High School Hegins, PA
Presentation transcript:

Des Places Residence Hall Duquesne University Pittsburgh, PA Peter Edwards – Mechanical Option Advisor - Dustin Eplee Des Places Residence Hall Senior Thesis Presentation Owner: Duquesne University Architect:WTW Architects Mechanical/Electrical Engineer:CJL Engineering Structural Engineer:Barber and Hoffman Inc. Civil Engineer:Gateway Engineers Construction Management Agency:Regency Construction Services Inc. Project Team 1

Building Overview Building Information Building Location and Site Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion Peter Edwards – Mechanical Option Des Places Residence Hall Presentation Outline Building Information Basic Information Size:131, 438 ft² Stories Above Grade:11 Estimated Project Cost:$27,535,000 Dates of Construction:March 1, 2010 – August 7, 2012 Project Delivery Method:Design-Bid-Build Occupancy Type:Student Dormitory LEED:Minimum of LEED Certification 2

Presentation Outline Building Location and Site Location Pittsburgh, Pennsylvania Surrounded by an urban environment Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Building Information Building Location and Site Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 3

Building Location and Site Site Square building footprint Building is oriented so that it faces almost exactly true north Surrounded by Seitz Street to the south and Stevenson Street to the east McCloskey Field Seitz Street Stevenson Street Des Places Residence Hall Presentation Outline Location Pittsburgh, Pennsylvania Surrounded by an urban environment Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Building Information Building Location and Site Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 4

Thesis Overview Proposal Replace fan coil units in existing dedicated outdoor air system with radiant ceilings and baseboard radiators Install a solar thermal system to preheat the domestic hot water in Des Places Redesign the building envelope of Des Places to allow more natural daylight into the perimeter bedrooms and living rooms Presentation Outline Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Proposal Results Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 5

Thesis Overview Proposal Replace fan coil units in existing dedicated outdoor air system with radiant ceilings and baseboard radiators Install a solar thermal system to preheat domestic hot water Redesign the building envelope by doubling the size of every bedroom and living room window Results Redesigned Dedicated Outdoor Air System $7,370 increase in yearly operational costs Cost $186,500 less than original system New system will increase the comfort of occupants Solar Thermal System Saves the central steam plant approximately 2,350 therms/year Payback period under 11 years with government incentives Building Envelope Redesign Larger windows allow significantly more natural light into the rooms throughout the year Daylighting analysis showed that some of the rooms already had an adequate amount of daylight Cost $203,312 more than the original building envelope $2,137 increase in yearly operational costs Presentation Outline Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Proposal Results Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 6

Presentation Outline Existing Mechanical System Total estimated cost = $2,827,770 System complies with ASHRAE Standards 62.1 and 90.1 Steam supply comes from central steam plant on campus Chilled water supply comes from central chiller plant on campus Electricity is supplied by Duquesne Light Key Facts Utility Rates Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 7

High pressure steam comes from central plant at a pressure of 50 lbs and a velocity of 6,000 fpm HPS passes through a pressure reducing valve Low pressure steam is used for the domestic water heater Remaining LPS is converted to hot water Presentation Outline Existing Mechanical System Steam Converter C-2 Converter C-1 Domestic Water Heater Flash Tank Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 8

Hot water supply starts at the two steam to hot water converters 140 °F supply temperature Hot water supply feeds coils in unit heaters, fan coil units and ERU-1 Presentation Outline Existing Mechanical System High pressure steam comes from central plant at a pressure of 50 lbs and a velocity of 6,000 fpm HPS passes through a pressure reducing valve first Low pressure steam is used for the domestic water heater Remaining steam is converted to hot water Steam Hot Water Unit Heaters and ERU-1 Fan Coil Units Expansion Tank Air Separator Converter C-1 Converter C-2 Make-Up Water PRV Station Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 9

Chilled water supply comes directly from central chiller plant 45 °F supply temperature Chilled water supply feeds coils in fan coil units and ERU-1 Presentation Outline Existing Mechanical System Chilled Water ERU-1 Fan Coil Units Expansion Tank Air Separator Make-Up Water PRV Station Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 10

Energy recovery unit uses 100% outdoor air Outdoor air is delivered to every room at a constant flow rate Presentation Outline Chilled water supply comes directly from central chiller plant 45 °F supply temperature Chilled water supply feeds fan coil units and ERU-1 Chilled Water Existing Mechanical System Dedicated Outdoor Air System Outside Air Exhaust Air ERU-1 Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 11

Presentation Outline Annual Energy Cost Primary Heating - $17,914/year Primary Cooling – $33,725/year Total - $95,663/year Existing Mechanical System Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 12

Mechanical System Redesign Objectives Presentation Outline Dedicated Outdoor Air System with Radiant Ceilings Reduce yearly energy consumption of building Reduce the cost of the dedicated outdoor air system Improve comfort of occupants Peter Edwards – Mechanical Option Des Places Residence Hall Diagram of a radiant ceiling produced by Barcol-Air Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 13

Mechanical System Redesign Objectives Presentation Outline Dedicated Outdoor Air System with Radiant Ceilings Reduce yearly energy consumption Reduce the cost of the dedicated outdoor air system Improve comfort of occupants Solar Thermal System Add renewable energy source to Des Places Reduce energy consumption of steam domestic water heater Produce a reasonable payback period Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 14

Mechanical System Redesign Objectives Presentation Outline Dedicated Outdoor Air System with Radiant Ceilings Reduce yearly energy consumption Reduce the cost of the dedicated outdoor air system Improve comfort of occupants Solar Thermal System Add renewable energy source to Des Places Reduce energy consumption of steam domestic water heater Produce a reasonable payback period Building Envelope Redesign Increase natural daylight in bedrooms and living rooms Eliminate the need for artificial light in perimeter rooms during the day Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 15

Analysis I - Dedicated Outdoor Air System Presentation Outline Design Overview CB Aqua radiant ceilings produced by Barcol-Air Baseboard radiators produced by Slantfin Peter Edwards – Mechanical Option Des Places Residence Hall Chosen Manufacturers Replace all fan coil units with radiant ceilings and baseboard radiators Energy recovery unit remains the same Thermostat and dew point sensor in each room Reduce fan energy consumption Eliminate fan noise in rooms Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 16 Slantfin baseboard radiator Barcol-Air radiant ceiling panel

Analysis 1 - Dedicated Outdoor Air System Presentation Outline Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 17

Presentation Outline Analysis I - Dedicated Outdoor Air System Computational Fluid Dynamics Analysis Accurate models of a typical bedroom with a fan coil unit and a radiant ceiling were created in Phoenics Cooling performance of each system was analyzed and compared Results Radiant ceiling produced a more uniform temperature distribution throughout the space Radiant ceiling produced a lower average temperature in the space by 1 °F Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 18

Presentation Outline Analysis I - Dedicated Outdoor Air System Velocity Profiles in a Typical Bedroom Room with Fan Coil Unit Maximum Velocity = 1.1 m/s Room with Radiant Ceiling Maximum Velocity = 0.6 m/s Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 19

Presentation Outline Analysis I - Dedicated Outdoor Air System Temperature Profiles in a Typical Bedroom Room with Fan Coil Unit Room with Radiant Ceiling Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 20

Presentation Outline Analysis I - Dedicated Outdoor Air System Energy Analysis In comparison to the original design, DOAS with radiant ceilings and baseboard radiators: Consumes 12,545 kW-hr LESS per year Consumes 6,611 therms MORE per year Costs $7,370 MORE per year to operate Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 21

Presentation Outline Analysis I - Dedicated Outdoor Air System System Cost Comparison DOAS with radiant ceilings and baseboard radiators costs $186,528 LESS than DOAS with fan coil units Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 22

Presentation Outline Analysis II - Solar Thermal System Design Overview Antifreeze loop with internal heat exchanger in existing domestic hot water tank Solar hot water heat exchanger will preheat domestic water in series with existing steam heat exchanger Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 23

Presentation Outline Analysis II - Solar Thermal System Design Overview Antifreeze loop with internal heat exchanger in existing domestic hot water tank Solar hot water heat exchanger will preheat domestic water in series with existing steam heat exchanger Peter Edwards – Mechanical Option Des Places Residence Hall Chosen Manufacturers Apricus would supply the solar collectors Evacuated tube collectors Sunmaxx Solar would supply the piping, pump station, accessories and controls Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 24

Presentation Outline Analysis II - Solar Thermal System Solar Collector Array Apricus evacuated tube collectors Better performance in cloudy and cold weather 10 year warranty 21 AP-30 collectors in array All collectors are at least 10 ft. from the edge of the roof in accordance with OSHA regulations Array faces south All collectors positioned at 45° from horizontal Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 25 Diagram of an Apricus evacuated tube solar collector

Presentation Outline Analysis II - Solar Thermal System Energy Output Solar thermal system produces 1,551 therms per year Net efficiency of central steam plant and distribution network is 66% Therefore system saves the central steam plant 2,350 therms per year Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 26

Presentation Outline Analysis II - Solar Thermal System Energy Output Solar thermal system produces 1551 therms per year Net efficiency of central steam plant and distribution network is 66% Therefore system saves the central steam plant 2350 therms per year Life Cycle Cost Analysis Total cost of system = $94,500 Applicable Government Financial Incentives Business Energy Investment Tax Credit: 30% of total system cost PA Sunshine Solar Rebate Program: 35% of total system cost Payback period between 10 and 11 years with government incentives Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 27

Presentation Outline Daylighting Breadth Daylighting Analysis A typical east facing bedroom and west facing bedroom was analyzed Models of both rooms were created and analyzed using AGI According to IESNA Lighting Handbook there should be at least 30 footcandles of light in each room The area of most concern in both rooms is the two desks Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 28

Presentation Outline Daylighting Breadth Illuminance Distribution in a Typical East Facing Bedroom East facing room with 4 ft. by 5 ft. window at 10 AM on September 23rdEast facing room with 8 ft. by 5 ft. window at 10 AM on September 23rd Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 29

Presentation Outline Daylighting Breadth Illuminance Distribution in a Typical West Facing Bedroom West facing room with 4 ft. by 5 ft. window at 1 PM on September 23rd West facing room with 8 ft. by 5 ft. window at 1 PM on September 23rd Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 30

Presentation Outline Daylighting Breadth Results Larger windows were more beneficial for the west facing bedroom East facing bedroom had an average illuminance value well over 30 footcandles with the smaller window Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 31

Presentation Outline Building Envelope Redesign Cost Analysis Building envelope cost will increase by $203,312Yearly Energy costs for Des Places will increase by $2,137 Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion 32

Presentation Outline Conclusion Final Recommendations DOAS Redesign – RECOMMENDED Higher yearly energy costs, but less expensive system Comfort of occupants will be increased Solar Thermal System – RECOMMENDED Saves central steam plant 2,350 therms per year Payback period under 11 years Building Envelope Redesign – NOT RECOMMENDED Limited daylighting benefits Significantly higher construction cost and yearly energy cost Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion Final Recommendations Acknowledgements Questions 33

Presentation Outline Conclusion Acknowledgements Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion Final Recommendations Acknowledgements Questions Special Thanks to: CJL Engineering Craig Duda, Harry Hoover, Tony Valenza and Brad Allis WTW Architecture Adam Stadt Duquesne University Barcol-Air George Hoekstra Apricus Eric Skiba Regency Construction Services Dustin Eplee AE Faculty Carl Hubben Jay Brognano 34

Presentation Outline Conclusion Questions ? Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion Final Recommendations Acknowledgements Questions 35

Presentation Outline Conclusion Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion Additional Slides

Presentation Outline Conclusion Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion Additional Slides

Presentation Outline Conclusion Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion Additional Slides

Presentation Outline Conclusion Change this area from 8” hollow core plank to 10” plank Peter Edwards – Mechanical Option Des Places Residence Hall Building Overview Thesis Overview Existing Mechanical System Mechanical System Redesign Objectives Analysis I – Dedicated Outdoor Air System Analysis II – Solar Thermal System Analysis III – Building Envelope Redesign Daylighting Breadth Conclusion Additional Slides