1 Fundamental Physics Tests using the LNE-SYRTE Clock Ensemble Rencontres de Moriond and GPhyS colloquium 2011 March 25 th 2011 La Thuile, Aosta valley,

Slides:



Advertisements
Similar presentations
Department ArtemisObservatoire de la Cote d'Azur1 A Sagnac interferometer with frequency modulation for sensitive saturated absorption (and applications.
Advertisements

High-resolution spectroscopy with a femtosecond laser frequency comb Vladislav Gerginov 1, Scott Diddams 2, Albrecht Bartels 2, Carol E. Tanner 1 and Leo.
Optical clocks, present and future fundamental physics tests
Atomic Parity Violation in Ytterbium, K. Tsigutkin, D. Dounas-Frazer, A. Family, and D. Budker
Hyperfine-Changing Collisions of Cold Molecules J. Aldegunde, Piotr Żuchowski and Jeremy M. Hutson University of Durham EuroQUAM meeting Durham 18th April.
1 Measurement of the Gravitational Time Delay Using Drag-Free Spacecraft and an Optical Clock Neil Ashby, Dept. of Physics, UCB 390, University of Colorado,
In Search of the “Absolute” Optical Phase
Centro Nacional de Metrología, CENAM, km 4.5 Carretera a los Cues, El Marques, Qro., J. Mauricio López R.
Results The optical frequencies of the D 1 and D 2 components were measured using a single FLFC component. Typical spectra are shown in the Figure below.
Single-atom Optical Clocks— and Fundamental Constants Hg+ clock Brent Young Rob Rafac Sebastien Bize Windell Oskay Luca Lorini Anders Brusch Sarah Bickman.
Precision measurement with ultracold atoms and molecules Jun Ye JILA, National Institute of Standards and Technology and Department of Physics, University.
Heidelberg, 15 October 2005, Björn Hessmo, Laser-based precision spectroscopy and the optical frequency comb technique 1.
1S-2S transition frequency measurements in atomic hydrogen N. Kolachevsky MPQ.
Matt Jones Precision Tests of Fundamental Physics using Strontium Clocks.
Blackbody radiation shifts and magic wavelengths for atomic clock research IEEE-IFCS 2010, Newport Beach, CA June 2, 2010 Marianna Safronova 1, M.G. Kozlov.
Reducing Decoherence in Quantum Sensors Charles W. Clark 1 and Marianna Safronova 2 1 Joint Quantum Institute, National Institute of Standards and Technology.
Jan W. Thomsen, G. K. Campbell, A. D. Ludlow, S. Blatt, M. Swallows, T. Zelevinsky, M. M. Boyd, M. Martin, T. Nicholson and J. Ye JILA, NIST and University.
EFTF 2007, Geneva I Guéna et al. I 1 Experimental study of intermodulation effects in a continuous fountain J. Guéna 3, G. Dudle 1, P. Thomann 2 1 Federal.
Stefan Truppe MEASUREMENT OF THE LOWEST MILLIMETER- WAVE TRANSITION FREQUENCY OF THE CH RADICAL.
Frascati, March 2006 Atomic Clocks in Space L. Cacciapuoti ESA-ESTEC (SCI-SP)
Titelmasterformat durch Klicken bearbeiten Transportable Optical Lattice Clocks.
AC Fundamental Constants Savely G Karshenboim Pulkovo observatory (St. Petersburg) and Max-Planck-Institut für Quantenoptik (Garching)
Des horloges atomiques pour LISA ? Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630) Observatoire de Paris, France Journées LISA-FRANCE.
Precise Measurement of Vibrational Transition Frequency of Optically Trapped molecules NICT Masatoshi Kajita TMU G. Gopakumar, M. Abe, M. Hada We propose.
Spectroscopy with comb-referenced diode lasers
Determination of fundamental constants using laser cooled molecular ions.
Kenneth Brown, Georgia Institute of Technology. Cold Molecular Ions 15  m Ca + X + ?
Dynamics of phase transitions in ion traps A. Retzker, A. Del Campo, M. Plenio, G. Morigi and G. De Chiara Quantum Engineering of States and Devices: Theory.
Experiments with ultracold RbCs molecules Peter Molony Cs Rb.
Progress towards laser cooling strontium atoms on the intercombination transition Danielle Boddy Durham University – Atomic & Molecular Physics group.
National Time Service Center. CAS Time Standard and Ensemble Pulsar Time Scale Ding Chen, George & Bill, Dick, PPTA team 2011 年 5 月 9 日, Beijing.
Elastic collisions. Spin exchange. Magnetization is conserved. Inelastic collisions. Magnetization is free. Magnetic properties of a dipolar BEC loaded.
__–––– Sensitivity Scaling of Dual Frequency Combs Ian Coddington, Esther Baumann, Fabrizio Giorgetta, William Swann, Nate Newbury NIST, Boulder, CO
HIGH RESOLUTION SPECTROSCOPY USING A TUNABLE THz SYNTHESIZER BASED ON PHOTOMIXING Arnaud Cuisset, Laboratoire de Physico-Chimie de l’Atmosphère, Maison.
Lineshape and Sensitivity of Spectroscopic Signals of N 2 + in a Positive Column Collected Using NICE-OHVMS Michael Porambo, Andrew Mills, Brian Siller,
PRINCIPLE OF THE EXPERIMENT PRESENT RESULTS see Ref.(5) E 1 PV: : PV E 1 6S-7S amplitude interferes with  E z : Stark induced E 1 amplitude POLARIMETRIC.
Lecture 3 16/9/2003 Recall Penning Trap orbits cylindrical coordinates: ( , ,z); B = constant along z radial (  ) and axial (z) electric.
Precision tests of bound-state QED: Muonium HFS etc Savely G Karshenboim D.I. Mendeleev Institute for Metrology (St. Petersburg) and Max-Planck-Institut.
Precision test of bound-state QED and the fine structure constant  Savely G Karshenboim D.I. Mendeleev Institute for Metrology (St. Petersburg) and Max-Planck-Institut.
High resolution spectroscopy with a femtosecond laser frequency comb
-Andrew Ludlow -Martin Boyd -Gretchen Campbell -Sebastian Blatt -Jan Thomsen - Matt Swallows -Travis Nicholson The Sr team: Group leader: Jun Ye New approaches:
The Infrared Spectrum of CH 5 + Revisited Kyle N. Crabtree, James N. Hodges, and Benjamin J. McCall.
Фото MANIPULATING THE QUANTUM STATE OF SINGLE ATOMS AND PHOTONS works of Nobel Laureates in physics 2012 A.V.Masalov Lebedev Physics Institute, RAS, Moscow.
K. Iwakuni, H. Sera, M. Abe, and H. Sasada Department of Physics, faculty of Science and Technology, Keio University, Japan 1 70 th. International Symposium.
Precision Laser Spectroscopy of H 3 + Hsuan-Chen Chen 1, Jin-Long Peng 2, Takayoshi Amano 3,4, Jow-Tsong Shy 1,5 1 Institute of Photonics Technologies,
THE J = 1 – 0 ROTATIONAL TRANSITIONS OF 12 CH +, 13 CH +, AND CD + T. Amano Department of Chemistry and Department of Physics and Astronomy The University.
Cosmological variation of the proton-to-electron mass ratio and the spectrum of H 2 Ruth Buning Bachelor project 2004.
Optical Clocks for Fundamental Physics in Space
A. Nishiyama a, K. Nakashima b, A. Matsuba b, and M. Misono b a The University of Electro-Communications b Fukuoka University High Resolution Spectroscopy.
Frequency combs – evolutionary tree Overview Frequency Metrology Measuring Frequency Gaps Frequency Combs as Optical Synthesizers Time Domain Applicatons.
Production of vibrationally hot H 2 (v=10–14) from H 2 S photolysis Mingli Niu.
Jeroen Koelemeij LaserLaB VU University PartnersFunding Putting optical-fiber frequency links to work.
Quantum Optics meets Astrophysics Frequency Combs for High Precision Spectroscopy in Astronomy T. Wilken, T. Steinmetz, R. Probst T.W. Hänsch, R. Holzwarth,
Status Report on Time and Frequency Activities at KRISS Taeg Yong Kwon Center for Time and Frequency, Division of Physical Metrology Korea Research Institute.
High Precision Mid-IR Spectroscopy of 12 C 16 O 2 : ← Band Near 4.3 µm Jow-Tsong Shy Department of Physics, National Tsing Hua University,
The Constancy of Constants. Dirac’s Large Number Hypothesis “A New Basis for Cosmology” Proceedings of the Royal Society of London, A165, 199 (1938) Ratio.
Laboratory Tests on Variations of Fundamental Constants Ekkehard Peik Physikalisch-Technische Bundesanstalt Time and Frequency Department Braunschweig,
Test of Variation in m p /m e using 40 CaH + Molecular Ions in a String Crystal NICT Masatoshi Kajita TMU Minori Abe We propose to test the variation in.
 The electron electric dipole moment (eEDM) is aligned with the spin and interacts with the giant (~84 GV/cm) effective internal electric field of the.
Tests of Lorentz Invariance with atomic clocks and optical cavities Fundamental Physics Laws: Gravity, Lorentz Symmetry and Quantum Gravity - 2 & 3 June.
TC, U. Dorner, P. Zoller C. Williams, P. Julienne
Diatomic molecules as probes for variation of fundamental constants
Probing New Forces with Isotope Shift Spectroscopy
Measurement Science Science et étalons
Fundamental bounds on stability of atomic clocks
Doppler-free two-photon absorption spectroscopy of vibronic excited states of naphthalene assisted by an optical frequency comb UNIV. of Electro-Communications.
Activity reports on CCTF/CCL JWG on Optical Frequency Metrology
Precision Control Optical Pulse Train
University of California, Berkeley
Presentation transcript:

1 Fundamental Physics Tests using the LNE-SYRTE Clock Ensemble Rencontres de Moriond and GPhyS colloquium 2011 March 25 th 2011 La Thuile, Aosta valley, Italy M. Abgrall, S. Bize, A. Clairon, J. Guéna, P. Laurent, Y. Le Coq, P. Lemonde, J. Lodewyck, L. Lorini, S. Mejri, J. Millo, J.J. McFerran, P. Rosenbusch, D. Rovera, G. Santarelli, M.E. Tobar, P. Westergaard, P. Wolf, L. Yi, et al.

2 Outline Atomic clocks and fundamental constants Rb vs Cs in atomic fountain clocks Some optical clock comparisons Constraints to variation of constants with time and gravitation potential Prospects

3 Principle of atomic clocks Goal: deliver a signal with stable and universal frequency Bohr frequencies of unperturbed atoms are expected to be stable and universal Building blocks of an atomic clock Can be done with microwave or optical frequencies, with neutral atoms, ions or molecules ε : fractional frequency offset Accuracy: overall uncertainty on ε y(t) : fractional frequency fluctuations Stability: statistical properties of y(t), characterized by the Allan variance  y 2 (  ) macroscopic oscillator atoms interrogation correction output

4 Atomic Transitions and Fundamental Constants Atomic transitions and fundamental constants  Hyperfine transition  Electronic transition  Molecular vibration  Molecular rotation Actual measurements: ratio of frequencies Electronic transitions test α alone (electroweak interaction) Hyperfine and molecular transitions bring sensitivity to the strong interaction

5 m p, g (i) are not fundamental parameters of the Standard Model m p, g (i), can be related to fundamental parameters of the Standard Model (m q /Λ QCD, m s /Λ QCD, m q =(m u +m d )/2) Recent, accurate calculations have been done for some relevant transitions Any atomic transition (i) has a sensitivity to one particular combination of only 3 parameters ( , m e /Λ QCD, m q /Λ QCD ) Alternatively, one can use ( , µ=m e /m p, m q /m p ) V. V. Flambaum and A. F. Tedesco, PRC 73, (2006) V. V. Flambaum et al., PRD 69, (2004) It is often assumed that : Atomic Transitions and Fundamental Constants

6 KaKa KqKq KeKe Rb hfs Cs hfs H opt000 Yb + opt Hg + opt Dy comb Sensitivity coefficients Dysprosium : RF transition between 2 accidentally degenerated electronic states of different parity K , K e : accuracy at the percent level or better K q : accuracy ? PR C73, (2006) Dzuba et al., Phys. Rev. A 68, (2003) In some diatomic molecules: cancellation between hyperfine and rotational energies also leads to large (2-3 orders of magnitude enhancement) Flambaum, PRA 73, (2006) Thorium 229 : nuclear transition in the optical domain (163nm) between 2 nearly degenerated nuclear states E. Peik and Chr. Tamm, Europhys. Lett.61, 181 (2003) E. Peik et al., arXiv: v2 Highly charged ions Flambaum, PRL 105, (2010) S. G. Porsev et al., PRL 105, (2010) Note: if a variation is detected, these coefficients provide a way to have a clear evidence from experiments with multiple clocks

7 Variation with time  Repeated measurements between clock A and clock B over few years Variation with gravitation potential  Several measurements per year, search for a modulation with annual period and phase origin at the perihelion Variation with space  Several measurements per year, search modulation with annual period and arbitrary phase 3 types of searches Annual modulation of the Sun gravitation potential at the Earth : ~

8 LNE-SYRTE ATOMIC CLOCK ENSEMBLE Hg, opt Cs, µW Rb, Cs, µW H, µW Phaselock loop  ~1000 s FO1 fountain FO2 fountain FOM transportable fountain Optical lattice clock Macroscopic oscillator Cryogenic sapphire Osc. H-maser Sr, opt

9 Time and frequency metrology  Fountain comparisons: accuracy ~4x  Secondary definition the SI second based on Rb hfs  Calibration of international time (LNE-SYRTE: ~50% of all calibrations)  Absolute frequency measurement of optical frequencies in the lab (Sr) and abroad (H(1S-2S) at MPQ, 40 Ca + in Innsbruck) Fundamental physics tests  Local Lorentz invariance in photon sector (CSO vs H-maser) and in the matter sector (Zeeman transitions in Cs fountain)  Stability of fundamental constants with time (Rb vs Cs, H(1S-2S) vs Cs, Sr vs Cs) and gravitation potential (Sr vs Cs) Development of Sr and Hg optical lattice clock PHARAO/ACES cold Cs atom space clock  Support the development of the project  Ground segment of PHARAO/ACES mission Applications of LNE-SYRTE clock ensemble Gen. Rel. Grav. 36, 2351 (2004) PR D 70, (R) (2004) J. Phys. B 38, S44 (2005) C.R. Physique 5, 829 (2004) PRL 90, (2003) PRL 92, (2004) PRL 84, 5496 (2000) PRL 102, (2009) PRL 100, (2008) PRA, 72, (2005) PRA 79, (2009) PRL 96, (2006) PRL 97, (2006) Eur. Phys. J. D 48, (2008) PRL 100, (2008) PRA 68, (2003) PRD 81, (2010) PRL 96, (2006) PRL 90, (2003) PRL 101, (2008) PRA 79, (2009) Appl Phys B 99, 41 (2010) Opt. Lett. 35, 3078 (2010) PRL 106, (2011)

10 Atomic fountain clocks More than 10 fountains in operation (LNE-SYRTE, PTB, NIST, USNO, JPL, NICT, NMIJ, METAS, INRIM, NPL, USP,…) with an accuracy a few and < for a few of them. Atomic quality factor: Best frequency stability (~ Quantum Projection Noise limited): 1.6x Cs levels ( 87 Rb similar) Ramsey fringes Best accuracy: 4x Real-time control of collision shift with adiabatic passage: Phys. Rev. Lett. 89, (2002)

11 LNE-SYRTE FO2: a dual Rb and Cs fountain Dichroic collimators  co-located optical molasses Dual Ramsey microwave cavity Synchronized and yet flexible computer systems with two independent optical tables Almost continuous dual clock operation since 2009 Cs GHz Rb 6.834…GHz J. Guéna et al., IEEE Trans. on UFFC 57, 647 (2010)

12 Example of a Rb vs Cs measurement (2007/2008) 16 Nov Jan 2008: 51 effective days of synchronous data Total uncertainty 1.1x Resolution 6x at 50 days (assuming white noise) J. Guéna et al., IEEE Trans. on UFFC 57, 647 (2010) S. Bize et al., J. Phys. B: At. Mol. Opt. Phys. 38, S44 (2005) S. Bize et al., C.R. Physique 5, 829 (2004) H. Marion et al., Phys. Rev. Lett. 90, (2003) Y. Sortais et al., Phys. Scripta T95, 50 (2001) S. Bize et al., Europhys. Lett. 45, 558 (1999) (FO2-Rb) (2007) = (8) Hz Investigation of the Distributed Cavity Phase shift reduces this uncertainty to < Collaboration with K. Gibble (PennState Univ., USA) PRL to appear in 1 or 2 weeks

13 Measurements of the Rb hyperfine splitting vs time Weighted least square fit gives: With QED calculations: With QCD calculations: V. V. Flambaum and A. F. Tedesco, PR C73, (2006) J. Prestage, et al., PRL (1995), V. Dzuba, et al., PRL (1999) Note: 87 Rb hyperfine transition was the first secondary representation of the SI second. BIPM CCTF recommended value (based on LNE-SYRTE 2002 data): Rb (CCTF)= (21) Hz Improvement by 5.8 wrt PRL 90, (2003) (-2.0±1.2) (1.7 standard deviation)

14 Variation of with gravitation potential Variation with space Rb vs Cs: Search for annual terms

15 The clock transition is in the optical domain allowing improved accuracy (talk by P. Lemonde) Confinement into the Lamb-Dicke regime is used to dramatically reduce the effects of external motion  Mandatory to gain over µWave clocks: Optical clocks Spectroscopy in the Lamb-Dicke regime Carrier transition, essentially unaffected by external motion Trapped ion clocks Lattice clocks

16 Frequency ratio of Al + and Hg + single ion clocks at NIST T. Rosenband et al., Science 319, 1808 (2008) Fractional uncertainty: 5.2x Since then improved to 8.6x Chou et al., PRL 104, (2010) in units of

17 Measurements against Cs fountains at JILA, Tokyo Univ. and SYRTE Strontium optical lattice clock’s absolute frequency  3 independent measurements in excellent agreement to within a few  Very different trap depths (150 kHz to 1.5 MHz) and geometries  Close to fountain accuracy limit Phys. Rev. Lett. 100, (2008) Eur. Phys. J. D 48, 11 (2008)

18 LNE-SYRTE (2011) NIST, (PRL 2007) PTB, (PRL 2004), (arXiv 2006) MPQ + LNE-SYRTE (PRL 2004) Berkeley, (PRL 2007) Tokyo, JILA, LNE-SYRTE, (PRL 2008) Overview of recent measurements NIST, (Science 2008) INDEPENDENT OF COSMOLOGICAL MODELS Least squares fit

19 Constraint to a variation of constants with gravity Berkeley, PRA 76, (2007) SYRTE (2011) NIST, SYRTE, PTB, PRL 98, (2007) SYRTE, Tokyo, JILA, PRL 100, (2008) NIST, PRL 98, (2007) Least squares fit INDEPENDENT OF COSMOLOGICAL MODELS

20 Summary and Prospects Atomic clocks provide high sensitivity measurements of present day variation of constants  Clock tests are independent of any cosmological model  Complement tests at higher redshift (geological and cosmological time scale)   Inputs for developing unified theories Improvements in these tests will come from:  Improvements in clock accuracy  As fast as in the last decade ?  Improvements in remote comparison methods  Coherent optical fiber links  Use PHARAO/ACES mission on ISS (talk by L. Cacciapuoti),  In the future, mission like USTAR dedicated to satellite remote comparisons  New atomic and molecular systems with enhanced sensitivities  Molecules  Highly charged ions  Nuclear transition in 229 Th  …