1 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE Central Tracker review Micromegas central & forward tracker  R&D and prototypes  CAD implantation.

Slides:



Advertisements
Similar presentations
RD S. Aune CEA/IRFU Micromegas Bulk for CLAS12 vertex tracker.
Advertisements

Micro MEsh GASeous Detectors (MicroMegas)
Micromegas studies using cosmic rays Franck Sabatié May 7th 2009 Saclay cosmic ray bench Data acquisition system and analysis tools MIP detection Position.
Status of the ATLAS MM project
Micromegas for CLAS12 Central Detector - Update Franck Sabatié November 19th 2009 Micromegas option for the Central Detector Why, Where, How ? R&D milestones.
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
Micromegas detectors for the CLAS12 central tracker Brahim Moreno (for the Saclay group) CLAS12 technical workshop 03/17/ 2010 Jefferson lab Update on.
Micromegas detectors for the CLAS12 central tracker Brahim Moreno (for the Saclay group) CLAS12 central detector meeting : 2 december 2009 Cea Saclay CERN.
Mechanical Status of ECAL Marc Anduze – 30/10/06.
The AMS-02 detector is based on a large acceptance (~0.5 m²sr) and high sensitivity spectrometer composed by a super-conducting magnet (0.8 T), cooled.
Mauro Raggi Status report on the new charged hodoscope for P326 Mauro Raggi for the HODO working group Perugia – Firenze 07/09/2005.
RD51 Common Test Beam: Status RD51 collaboration week Kolymbari, June 2009 Yorgos Tsipolitis NTUA.
INFN-LNF / D. Orecchini – S. Tomassini – 06/24-25/2015 CLAS12 – RICH MECHANICS REVIEW SLIDE 1 RICH MODULE INTEGRATION IN CLAS_12 – LAST LAYOUT RICH MODULE.
1 SBS Spectrometer / GEP5 Conf.. 2 Tracking Requirements Requirements Tracking Technology DriftMPGDSilicon High Rate: MHz/cm 2 (Front Tracker)
-Stephan AUNE- RD51 Bari 2010 CEA DSM Irfu 08/10/20101 Saclay MPGD workshop.
WG1 summary P. Colas, S. Duarte Pinto RD51 Collaboration meeting in Bari October 7-10, 2010.
Atsuhiko Ochi Kobe University 25/06/2013 New Small Wheel MicroMegas Mechanics and layout Workshop.
Ciemat Mechanical Structure Proposal for a DHCAL m 3 Prototype. Enrique Calvo Alamillo Paris
SPHENIX GEM Tracker R&D at BNL Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
26 April 2013 Immanuel Gfall (HEPHY Vienna) Belle II SVD Overview.
Central tracker for 12GeV upgrade in HallB Micromégas : a new detector for CLAS12 Detector’s principle GARFIELD simulation Spatial resolution measurement.
Status report on MURAY telescope R&D
Status of straw-tube tracker V.Peshekhonov, D.Peshekhonov, A.Zinchenko JINR, Dubna V.Tikhomirov P.N.Lebedev Physics Institute, Moscow Presented on the.
EPS-HEP 2015, Vienna. 1 Test of MPGD modules with a large prototype Time Projection Chamber Deb Sankar Bhattacharya On behalf of.
CLAS12-RICH Mechanical Design Status-Report CLAS12 RICH Review September 5-6 th 2013 S. Tomassini, D. Orecchini1 D. Orecchini, S. Tomassini.
Thin Silicon R&D for LC applications D. Bortoletto Purdue University Status report Hybrid Pixel Detectors for LC.
Test beam setup: status report 31/03/2009 M. Alfonsi (CERN)
M. Bianco On behalf of the ATLAS Collaboration
Resistive anode studies D. Attié, P. Colas, E. Delagnes, M. Dixit, A. Giganon, M. Riallot, F. Senée, S. Turnbull Micromegas Large Prototype panels Studies.
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
PNPI, R&D MUCH related activity ● Segmentation ● Simulation of the neutral background influence ● R&D of the detectors for MUCH ● Preparation to the beam.
A New GEM Module for a Large Prototype TPC: Status and Plans By Stefano Caiazza On behalf of the FLC DESY.
Takeshi Matsuda LC TPC Collaboration March 5, 2008 TPC Endcap Materials.
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
S. AUNE 15/09/08 Micromegas Bulk for CLAS12 tracker.
Wenxin Wang 105/04/2013. L: 4.7m  : 3.6m Design for an ILD TPC in progress: Each endplate: 80 modules with 8000 pads Spatial Resolution (in a B=3.5T.
D. M. Lee, LANL 1 07/10/07 Forward Vertex Detector Overview Technical Design Overview Design status.
Micromegas Bulk Demonstrator One type of Bulk: Active area; 115 mm for 288 strips, 500 mm long Material: 100 µm PCB, 5 µm Cu, 18µm mesh, 20µm Mylar Two.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Micromegas for the Central Tracker Sébastien Procureur CEA-Saclay.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
Review of Micromegas Tracking Detectors for CLAS12 – May 7, 2009 Reviewers: Madhu Dixit, Mac Mestayer Presentations covered the following topics: –detector.
Zaragoza, 5 Julyl Construction of and experience with a 2.4 x 1 m² micromegas chambers Givi Sekhniaidze On behalf of the Micromegas community.
Upgrade PO M. Tyndel, MIWG Review plans p1 Nov 1 st, CERN Module integration Review – Decision process  Information will be gathered for each concept.
Redesign of LumiCal mechanical structure W.Daniluk, E.Kielar, J.Kotula, K.Oliwa, Wojciech Wierba, L.Zawiejski Institute of Nuclear Physics PAN Cracow,
CLAS12 Central Detector Meeting, Saclay, 3 Dec MVT Read-Out Architecture & MVT / SVT Integration Issues Irakli MANDJAVIDZE.
Technical Design for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
Baby MIND Scintillator modules 11 November 2015 Revision E. Noah.
Precision Drift Tube Detectors for High Counting Rates O. Kortner, H. Kroha, F. Legger, R. Richter Max-Planck-Institut für Physik, Munich, Germany A. Engl,
SiW Electromagnetic Calorimeter - The EUDET Module Calorimeter R&D for the within the CALICE collaboration SiW Electromagnetic Calorimeter - The EUDET.
Atlas SemiConductor Tracker final integration and commissioning Andrée Robichaud-Véronneau Université de Genève on behalf of the Atlas SCT collaboration.
Marc Anduze – EUDET Meeting – PARIS 08/10/07 Mechanical R&D for EUDET module.
-Stephan AUNE- RD51 BARI. Saclay MPGD workshop R&D 09/10/20101 Saclay workshop R&D for new Bulk structure.
Feasibility of the detection of D 0 mesons in the NA61/SHINE experiment: Vertex detector for NA61/SHINE P. Staszel and Yasir Ali Jagiellonian University.
STRAW TRACKER SYSTEM CAD STATUS :
Micromegas Vertex Tracker Status Report
FCAL R&D towards a prototype of very compact calorimeter
Technical Design for the Mu3e Detector
Commissioning and Calibration Strategies for Micromegas Vertex Tracker
Enrique Calvo Alamillo DAEGU
- CT INSTALLATION PROCEDURE OVERVIEW -
- STT LAYOUT - SECTOR F SECTOR A SECTOR B SECTOR E SECTOR D SECTOR C
Vertex Detector Mechanical R&D Design Questions and Issues
CLAS12 - CT meeting 10 October 2013
IFR detector mechanics
(A) (B) - CENTRAL SUPPORT FRAME - INFN-LNF - SPAS 1
First of all we will remind some numbers:
WG4 – Progress report R. Santoro and A. Tauro.
TPC Paul Colas Technical meeting, Lyon.
Micromegas for CLAS12 – Preliminary work on integration
Presentation transcript:

1 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE Central Tracker review Micromegas central & forward tracker  R&D and prototypes  CAD implantation study  Interfaces

2 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE Clas12 R&D on detectors CLAS12 R&D and prototype in 2009 –Bulk in high magnetic field at Jlab –Spark rate with alpha source –Spark rate with muon and hadron beam at CERN –Resistive kapton film prototype –Development on curved drift with X tile prototype –Cosmic bench for future prototypes MIP’s characterization CLAS12 R&D and prototype in 2010 –Spark rate with alpha source at 1.5 Tesla –Forward prototype (thin flat, segmented mesh) –Y tile prototype –Beam at CERN (forward, gas studies,…) –Beam test at Jlab ?

Micromegas tracker: CAD study

4 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CLAS12 Micromegas tracker CAD Study The CAD study for MM implantation was done in 2007 for feasibility The The study was based on successful technical solutions validated by experiments before 2007 This study was done on a mixed solution for the central tracker –two double silicon tracker layers at low radius and three double Micromegas layers at higher radius. The forward tracker was based on Micromegas solution with three double layers.

5 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE Central tracker mixed solution: Si +µM Symbiosis between Si and µM: to be studied: –Mechanics Common tracker structure Common alignment system Localization in space for minimum dead zone and maximum spatial resolution Common connectors and/or flex cables –Electronics Common ASIC Common Concentrator Common DAQ –Collaboration on various topics mentioned above during the development phase.

6 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE Central Tracker CAD study Magnet Forward tracker Micromegas central tracker Forward front end electronics Central front end electronics

7 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE Tracker dimension Detector Radius (mm) length (mm) Circumference (mm) Surface (m 2 ) X strips number Y strips number d1X d1Y d2X d2Y d3X d3Y Total surface : Each layer of detection is composed of two MM detectors with X and Y strips at 90°. The usability of a single X-Y detection PCB board will be studied in 2009 The bulk maximum size is 600 mm x 800 mm. The cylinders where divided in three sectors to match dead zone

8 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE Demonstrator tile: detector structure Each bulk PCB is mechanically fixed to a light structure which sets its curvature. The shape and material will be studied for low material budget. The mylar drift window is glued on the bulk active area. Detector structure Detector structure with bulk Demonstrator picture

9 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CAD study: tile and dead zone In this first study we have a rather large dead zone of 30 mm between adjacent tile active area. Further studies will be done to reduce the dead zone and match Si (tbc). The no dead zone configuration imply overlap of tiles (complex structure) Flex connection Active area

10 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CAD study: central structure The central structure will hold the bulk tiles on several radii for the barrel and at several positions for the forward disk. Each tile will be extractable from the structure independently from the others. The whole structure with its detectors and electronics will be extractable from the magnet through a slide rail system. Si tracker Location for curved bulk Location for electronic Location for disk bulk (forward) HT cable and gas (volume representation)

11 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CAD study: central structure with µm tiles The electronics box will be hooked to the central strucrure allowing: –Box dismounting –Single flex disconnection –FE and concentrator card access. Flex for forward tracker Electronic FE and concentrator Forward tracker (magenta) Central tracker (blue)

12 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CAD study: central structure- cut view The cylinder layers are divided in three sectors in the 2007 study. Barrel tracker (blue) Gas pipe distribution (violet) Dead zone between sectors

13 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CAD study: Forward Micromegas Tracker The forward tracker consisted in three layers of flat disks. Each disk is two faced with U strips on one side and V strips at 60° on the other side. Each disk side is divided into 3 sectors (6 in the most recent simulation). The disks are located just after the cylindrical tracker every 15 mm. The sectors of each twin disk are not aligned to avoid dead zones (tbc). FMT : 6 disks piled up Central tracker

14 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CAD study: FMT, dimension Internal diameter (mm) External diameter (mm) Surface (m 2 ) pitch (micron) Number of strips Disk Total To obtain a thin flat Micromegas, the PCB has to be set on a support. We first considered to use the COMPASS technique using a 3 mm thick Nomex honeycomb panel on which the 100 µm thick PCB is glued and the detector stays flat. The exact cutting of the disk is not yet definied

15 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CAD study: flex for FE readout In order to located the front end electronic at the rear of the tracker we will use 800 mm long flex. The flex will be going between the CTOF and the last central tracker layer. Forward µm detectors Central µm detector Central Si detector 5° cone from target FMT flex

16 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CAD study: FMT mesh segmentation In order to reduce dead time due to discharges when there is high occupancy at low radii, the mesh will be divided in several (2 in this study) independents areas. While sparking in inner region, the detector will still be operating in the outer region. An R&D on mesh segmentation will be done in to study the minimization of the dead area between the two mesh surfaces and to validate the concept on a prototype in beam ( dead zone < 1mm). Active area Mesh segmentation

17 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE CLAS12 CT internal interfaces We need the space allocation for each sub system to go further in CAD studies –Can be done when final choice are made (i.e. MM for barrel) and constrains of each sub system studied together. We need a Coordinator for the CT: –Interface can be worked with neighbor and proposed to CTC –Common 3D CAD model updated every 6 month –Assembly plan –Budget: weight, heat load, power consumption,… –CT meeting every year for a Preliminary Design Review in 2011

18 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE HTTC Magnet Neutron detector Ctof MM barrel Si barrel Cryo target MM Forward Interfaces Mechanical Electrical Thermal Accessibility detectors Electronics Servitude Gas HT Signal,…/… CT a Russian doll integration Limited space budget: crowded inside !!

19 CLAS12/Central Tracker review. Saclay 12/09 Stéphan AUNE MM electronic location The maximum distance between MM detectors and the front end electronics is around 1 meter. two options: –In the tube: we fit in the fixation tube (around SVT elec. ?) Uneasy fixation and access, cooling needed, open tube ? –Outside the tube: we fit around the fixation tube Longer distance to detector, easy fixation and access, hole in tube, interface with light guide lines. Forward elc.barrel elc. Forward elc.barrel elc. In tube Outside