RPCs in biomedical applications Research Program of National Interest - PRIN University of Pavia & INFN (Italy) RPC 2005, Seoul, 10-12 October 2005 Monica.

Slides:



Advertisements
Similar presentations
PET                                          .
Advertisements

1 Continuous Scintillator Slab with Microchannel Plate PMT for PET Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat 2, Fukun Tang 2,
GEANT4 Simulations of TIGRESS
Multiplicity analysis and dN/d  reconstruction with the silicon pixel detector Terzo Convegno Nazionale sulla Fisica di ALICE Frascati (Italy) – November.
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Chapter 8 Planar Scintigaraphy
DFNA-Ilie Cruceru PERSPECTIVES FOR A POSITRON EMISSION TOMOGRAPHY (PET) PLANT BASED ON RESISITIVE PLATE COUNTER (RPC) Ilie Cruceru, Mihai Petrovici, Florin.
Aging, High Rate and Shielding L. Lopes Lip-Coimbra.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
24-28 May, 2010 S. Mastroianni - 17th Real-Time Conference, Lisboa, Portugal ARGO-YBJ is a cosmic ray air shower detector based on a single layer of RPC.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
GAMMA RAY SPECTROSCOPY
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
N_TOF fission data of interest for ADS
Mauro Raggi Status report on the new charged hodoscope for P326 Mauro Raggi for the HODO working group Perugia – Firenze 07/09/2005.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Gamma Spectroscopy HPT TVAN Technical Training
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
Very High Resolution Small Animal PET Don J. Burdette Department of Physics.
CUORICINO and CUORE Chiara Brofferio Università di Milano – Bicocca and INFN, Sez. di Milano NOW 2004 – Otranto 12 – 17 September 2004 On behalf of the.
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
Status of PNPI R&D for choice of the MUCH tracking base detector (this work is supported by INTAS) ■ Introduction ■ MICROMEGAS ■ GEM ■ MICROMEGAS+GEM ■
Fundamental Limits of Positron Emission Tomography
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
Optimization of the Resistive Plate Chamber operation with a closed loop gas system at the Large Hadron Collider experiments M. Capeans, I. Glushkov, R.
Barrel RPC Chamber consists of 2 double-gaps, each equipped with a common plane of 96 strips read-out by 6 front-end boards. The two double- gaps have.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 1 Biomedical Imaging I Class 5 – Radionuclide Imaging (PET, SPECT), Part 3: Attenuation and Scatter.
T. Sugitate / Hiroshima / PHX031 / Nov.01 The Photon Spectrometer for RHIC and beyond PbWO 4 Crystal Density 8.29 g/cm 3 Radiation length 0.89 cm Moliere.
Diego Gonzalez Diaz University of Santiago de Compostela ITEP IHEP (Protvino), ITEP (Moscow), INR (Moscow), LIP(Coimbra), USC(Santiago de Compostela)
(Santiago de Compostela-Spain)
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
Study of UV absorption and photoelectron emission in RPC (Resistive Plate Counters) detector with an UV source Carlo Gustavino (INFN-LNGS) RPC and their.
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
16. January 2007Status Report On Compton Imaging Projects 1 Status Of Compton Imaging Projects Carried Out In The CIMA Collaboration HPD Brain PET Meeting.
Hadronic interaction studies with the ARGO-YBJ experiment (5,800 m 2 ) 10 Pads (56 x 62 cm 2 ) for each RPC 8 Strips (6.5 x 62 cm 2 ) for each Pad ( 
Nuclear Medicine Principles & Technology_I
Tests of RPCs (Resistive Plate Chambers) for the ARGO experiment at YBJ G. Aielli¹, P.Camarri¹, R. Cardarelli¹, M. Civardi², L. Di Stante¹, B. Liberti¹,
Slide 1Crispin Williams INFN BolognaALICE TOF The ALICE-TOF system 1. Quick overview of the TOF system that we are building 2. The Multigap Resistive Plate.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Development of RPC based PET B. Pavlov University of Sofia.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Gamma Detector of Plastic Scintillator Oct. 2, 2009 IP-BSM Group 1.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
Small, fast, low-pressure gas detector E. Norbeck, J. E. Olson, and Y. Onel University of Iowa For DNP04 at Chicago October 2004.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
RPC February 2010 SPATIAL RESOLUTION OF HUMAN 3D RPC-PET SYSTEM 1 LIP, Laboratório de Instrumentação e Física Experimental de Partículas, Coimbra,
DEVELOPMENT OF MULTI-GAP RESISTIVE PLATE CHAMBER(MRPC) FOR MEDICAL IMAGING Arnab Banerjee 1, Arindam Roy 1, Saikat Biswas 1,2*, Subhasis Chattopadhyay.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
Chapter-2 The Planar Imaging Important points in chapter 2 (chapter 13 from the book) The gamma camera (the basic principles of the gamma camera) The types.
Nuclear Medicine Introduction
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
Chapter-5 Positron emission tomography (PET)
The ALICE-TOF system 1. Quick overview of the TOF system that we are building 2. The Multigap Resistive Plate Chamber -what is it? 3. Difference in.
P.E.T. Positron Emission Tomography
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
GLAST LAT tracker signal simulation and trigger timing study
Detailed simulations of a full-body RPC-PET scanner
Summary of the Compton-PET project
Development of a High Precision Axial 3-D PET for Brain Imaging
Very preliminary study of the random background for the BiPo detector (PhoSwich configuration) Work done by Jonathan Ferracci.
TO LOW ENERGY NEUTRONS AND TO LOW ENERGY NEUTRONS AND
Application of Nuclear Physics
Function and Structure in
Assist. Prof. Dr. Ilker Ozsahin Oct
Presentation transcript:

RPCs in biomedical applications Research Program of National Interest - PRIN University of Pavia & INFN (Italy) RPC 2005, Seoul, October 2005 Monica M. Necchi

PET: status of the art  PET generates images depicting the distributions of positron-emitting nuclides in patients  This technique is used to measure “in vivo” biochemical and physiological processes in any organ  PET provides 2D and 3D images of the living under study  Improvements have seen a rapid and still ongoing development

The method Method of administration: Injection (appropriate for the organ under study) How to determine distribution Blood volume/flow/organ uptake What type of radionuclides? positron emitters How to detect? Photon detection

A PET event  Positron emitters are used for radioactive labeling  Positrons annihilate with e - in tissue and two 511 keV γ are emitted back- to-back

Photon detection  In the typical scanner, several rings of detectors surround the patient  PET scanners use annihilation coincidence detection (ACD) to obtain projections of the activity distribution in the subject

Detectors in PET tomographs  Scintillation detectors are being used in PET tomographs  In the past: NaI(Tl) crystals –Light output: 100 –Decay time (ns): 230 –Density (g/cm 3 ): 3.7 –Hygroscopic: YES  Nowadays: BGO crystals –Light output: 15 –Decay time (ns): 300 –Density (g/cm 3 ): 7.1 –Hygroscopic: NO  New trend: LSO crystals –Light output: 75 –Decay time (ns): 40 –Density (g/cm 3 ): 7.4 –Hygroscopic: NO

Current PET limitations The image quality of the current PET is poor because of: The image quality of the current PET is poor because of:  A short Field Of View (FOV)  Detector boundary limitations to 2x2 PMT blocks no full energy reconstruction  Dead time and saturation of the electronics  Low detector counting rate capability Current PET captures only 0.2 million pairs per second of the original 1400 million photons pairs per second emitted in the patient body (efficiency order ) Current PET captures only 0.2 million pairs per second of the original 1400 million photons pairs per second emitted in the patient body (efficiency order )

RPCs in PET Key features of RPCs: 1. Small reading pads 2. Small time jitter (down to 50 ps) 3. Thin converter plate (tiny parallax) 4. Low cost (about $/m 2 ) Why should we use RPCs?  Good spatial resolution (1 + 3)  Long FOV, high geometrical efficiency, high statistic, high signal/noise ( )  Good time resolution, point- like data, noise reduction (2)  Affordable price (4)

RPC gamma efficiency E ( γ ) = 500 keV ε (gap I) = ε (gap II)= ε (DG) = Gamma efficiency of a double gap bakelite RPC in case of isotropic emission

E ( γ ) = 500 keV Photoelectric effect  Z 5 Compton effect  Z Processes involving gamma

 Study of suitable material for the target planes  Many features of RPCs do not depend on the material they are made of, so we can easily try new ones  Which materials? –High atomic number (Z) Photoelectric and Compton effects are enhanced –Resistive features How to increase RPC gamma efficiency

Coating materials Electrons 0,5 MeV Gamma 0,5 MeV d (g/cm3)R (g/cm2)R (mm) tot att (cm2/g) u (1/mm) Pb11,30,3360,2971,61E-010,182 Tl11,90,3350,2821,58E-010,188 Bi9,70,3340,3441,66E-010,161 Ce6,80,3040,4471,04E-010,071 Ba3,50,3050,8719,92E-020,035 PbO90,32680,3631,56E-010,140 BaO5,720,29520,5169,80E-020,056 Bi2O38,550,31920,3731,58E-010,135 CeO27,130,28340,3971,01E-010,072 Pb3O49,10,32230,3541,54E-010,140 Tl2O9,520,3330,3501,55E-010,148 Tl2O39,80,3190,3261,51E-010,148 Bachelite1,251,85E-011,4809,21E-020,012 Vetro2,42,14E-010,8938,71E-020,021 Vetro Pb6,222,97E-010,4771,43E-010,089 Gd2O37,4072,99E-010,4041,10E-010,081

Coating features  The proper coating technique seems to be serigraphy, since it allows to have homogeneous and smooth layers of deposited mixture in thickness greater than hundreds of microns  The coating has to be as smooth as possible  The coating thickness has to be ≤ e - range in that material

Coating materials under study   The most promising mixtures seem to be PbO, Bi 2 O 3 and Tl 2 O. We plan to use Oxide- based mixtures for the resistive properties of the electrodes  First data from the simulation considered lead glass as target material in a single gap RPC  Next results showed the importance of employing a high Z material, e.g. a serigraphable “paste” made of PbO  We are synthesizing a compound, 50%mol SiO 2 – 50%mol PbO: the H.V. electrodes are going to be made by those monoliths (rising questions: the surface roughness)

Materials simulation

Efficiency simulation

To increase efficiency We can employ more than just one target layer glass multigap RPC We can employ more than just one target layer glass multigap RPC Multigap I set up – –5 gas gaps; the spacing is kept by 0.3 mm diameter nylon fishing line – –Electrodes made of thin glasses (1 mm for the outer electrodes, 0.15 mm for the inner ones) – –The detector is enclosed in a metallic gas-tight box, filled with the gas mixture: C 2 H 2 F %, SF 6 2.5%, iC 4 H 10 5%

Multigap gamma efficiency (simulation)

Multigap prototype I MG I has a pad on the lower PCB layer and strips (2 mm wide, 1mm spaced) on the upper layer

The box with the multigap The metallic gas tight box with H.V. and signal cables; signal is picked up by a flat cable The metallic gas tight box with H.V. and signal cables; signal is picked up by a flat cable

Multigap prototype II  Multigap II set up: – –5 gas gaps; the spacing is kept by 0.3 mm diameter nylon fishing line (like the first one) – –Electrodes made of thin glasses (1 mm for the outer electrodes, 0.4 mm for the inner ones) – –With thicker glasses we expect a greater counting rate – –The detector is enclosed in a metallic gas- tight box, filled with the gas mixture: C 2 H 2 F %, SF 6 2.5%, iC 4 H 10 5%

Multigap prototype II Signal is picked up on the upper pad Signal is picked up on the upper pad

Simulation data  Geometry, materials, gas, gamma and electron generation and transport using Geant4-based frame work  Minimum detector physics simulation  + saturation  Preliminary MC data for multigap I  Optimization of MC simulation  Simulation of SiO 2 -PbO monoliths as multigap electrodes

Multigap simulation gamma source (661 keV) Multigap Aluminum case electron

Examples of Geant4 output Energy spectrum of gamma-electrons in the gas gaps With secondary Compton Without secondary Compton Secondary Compton electrons only at low energies E (MeV)

Electrons in the gaps Multigap I simulation Decreased geometrical acceptance

Multigap I Noise subtracted plots Counting rate at different thresholds: 2.5 mV, 3.5 mV and 4.5 mV Counting with a source, 137 Cs, whose activity is 5 μCi Counting with a γ source, 137 Cs, whose activity is 5 μCi

Multigap II Thicker glasses  greater counting rate

Simulation vs. experimental data  Primary and secondary Compton are seen as one by the electronics  Limits on cluster simulation with Geant4  46% of electrons cross two adjacent gaps (in MGI)

Outlook  A multigap prototype made of proper materials ready within a couple of months  Increasing efficiency using a stack of multigaps and new materials  Study of image reconstruction techniques

R. Guida, G. Musitelli, R. Nardò, M.M. Necchi, D. Pagano, S.P. Ratti, G. Sani, A. Vicini, P. Vitulo, C. Viviani Dip. Fisica Nucleare e Teorica Università di Pavia Istituto Nazionale Fisica Nucleare Sez. di Pavia