7.3.4 Student Book © 2005 Propane Education & Research CouncilPage 1 7.3.4 Identifying the Components and Operating Characteristics of Limit and Fan Controls.

Slides:



Advertisements
Similar presentations
Electrical Sensing Devices. What are the basic functions of electrical control? u safety u convenience u comfort.
Advertisements

SWITCHES, FUSES, & CIRCUIT BREAKERS
E1 – Electrical Fundamentals
Thermostats, Pressure Switches, and Other Electric Control Devices
7.3.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components & Operating Characteristics of Wall Thermostats (Heat.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
HVAC Commercial Ref.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
Heating Control Devices
3.7.6 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
3.7.4 Student Book © 2004 Propane Education & Research CouncilPage Identifying Testing Procedures for Anhydrous Ammonia (NH3) Contamination Because.
3.4.6 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Compressors Knowledge of the processes involved in maintaining.
2.3.9 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Purging Containers & Injecting Methanol Prior to.
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
7.4.2 Student Book © 2005 Propane Education & Research CouncilPage Reading Electrical Control Circuit Diagrams In the course of repairing a gas.
ST9120U1003 Universal Electronic Fan Timer Training Module
Module 2: Hardware and Terminology
3.2.2 Student Book © 2004 Propane Education & Research CouncilPage Performing DOT Cylinder Evacuation and Vapor Flaring Operations Before DOT cylinder.
Section 4: Electric Motors
Student Handout Packet Go to page A4. Please answer the following questions using page A4.
1 HVAC214 – Electrical for Oil Fan Centers. 2 Designed to provide low voltage control of blower motors and auxiliary circuits. Provide a good junction.
1 HVAC 214 Electricity For Oil Heat Fan Center Relays.
7.3.1 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Operating Characteristics of Common Sensing Devices A sensing.
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
Fan Switch and Limit Switch Information. FAN Switch.
7.2.4 Student Book © 2005 Propane Education & Research CouncilPage Identifying Procedures for Measuring Current Between Two Given Points in an.
7.4.1 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Operating Characteristics of Circuit Control Devices, Electromagnetic.
5.1.5 Student Book © 2005 Propane Education & Research CouncilPage 1 Specific measures are required by the LP-Gas Code for the prevention of dispenser.
HYDRONIC HEATING AQUASTATS
7.2.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying Procedures for Measuring Resistance Between Two Given Points in.
7.1.3 Student Book © 2005 Propane Education & Research CouncilPage Applying a Systems Approach to Gas Appliance Troubleshooting Troubleshooting.
Continue The information provided in this training module covers the schematic flow charts for all ovens and ranges that utilized a preheat board, Self.
3.4.7 Student Book © 2004 Propane Education & Research CouncilPage Examining Bulk Plant Electrical Systems Prevention of gas ignition in transfer.
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
Student Book © 2004 Propane Education & Research CouncilPage Documenting Vapor Distribution System Installations Documenting your work.
BAKE BROIL - SELECT PROGRAM - CONV BAKE CONV BROIL SELF CLEAN On any diagram screen, double click any of the following components to bring you to a description.
5.1.9 Student Book © 2005 Propane Education & Research CouncilPage Installing Propane Dispensers Successful propane dispenser installations are.
Chapter 4 Overload Relays.
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
3.4.3 Student Book © 2004 Propane Education & Research CouncilPage Bulk Plant Emergency Shutdown Equipment and Periodic Examination Methods One.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
4.1.2 Student Book © 2004 Propane Education & Research CouncilPage Determining System Load and Customer Demand Profile Designing a satisfactory.
Water Detectors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Converting ASME Tanks in Ammonia Service to Propane.
HVAC Wiring diagram 5 channel output (5A relay) Speed: High/Medium/Low Mode: Cooling / Heating /Dehumidifier HVAC is a module specially for Air Conditioner.
3.1.8 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
Student Handout Packet – Page A7
What is a Thermostats  A device which automatically regulates temperature. regulates temperature.regulates temperature.  Thermostats activates different.
PHSAUTOMOTIVESALSPHSAUTOMOTIVESALS Electric Cooling Fans.
Greenhouse Management.  List the different types of heating systems used in a greenhouse.  Describe the advantages and disadvantages of each type of.
7 A/C System Components, Operation, and Service.
Fluid Power Control.
Heating Maintenance and Repair
E3 HVACR Controls and Devices
Automotive Heating And Air Conditioning
Unit 13 Oil-Burning Equipment
Section 6: Air-Conditioning (Heating And Humidification)
E3 HVACR Controls and Devices
Presentation transcript:

7.3.4 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Limit and Fan Controls A vital safety component of warm air furnaces and warm water boilers is the limit control. In this module, you will learn to: 1.The purpose and operating characteristics of limit and fan controls

7.3.4 Student Book © 2005 Propane Education & Research CouncilPage 1 Identifying the purpose and operating characteristics of limit and fan controls The purpose of a limit control is to monitor the heating system for overheating conditions; it turns off the heat source before a dangerous condition arises. Most limit controls are constructed of a normally closed (N/C) single pole/single throw (SP/ST) heat sensitive electrical switch. Physical Description— The more economical limit controls have a fixed temperature setting with temperature sensed by a bimetal device. Figure 1. Disc Bimetal Limit Control

7.3.4 Student Book © 2005 Propane Education & Research CouncilPages 1 & 2 Circuit Operation— The limit control is a heat sensitive electrical switch. It breaks the circuit to the heat source in the event of an overheating condition. The limit control can be placed in several different areas of the system's circuit. Temperature Settings— Most limit controls are set to open their contacts at 200° F, although the manufacturer determines the exact setting. For example, a limit control operating with a differential of 25° F: This means that at 200° F the bimetal forces the contact open. The contact will not close until the temperature drops to 175° F.

7.3.4 Student Book © 2005 Propane Education & Research CouncilPages 2 & 3 The purpose of a fan control is to monitor the heating system and activate the fan or blower after sufficient heat is available for distribution. Figure 2. Combination High Limit and Fan Control (The Bimetal Sensor Extends Into the Heat Exchanger) Most fan controls are constructed of a normally open (N/O) single pole/single throw (SP/ST) heat sensitive electrical switch.

7.3.4 Student Book © 2005 Propane Education & Research CouncilPage 2 Physical Description of a Fan Control. The fan control completes the circuit for the blower. The two most common styles of fan controls are (1)heat sensitive fan controls and (2)time delay relay controls. Heat Sensitive Fan Controls. Heat sensitive fan controls sense temperature by means of bimetals. Remember, fan controls are normally open (n/o) contacts. As the bimetal detects heat the contacts begin to close. A complete circuit is made when the contacts close completely. The fan control also provides a delay on the blower. When the walls of the heat exchanger are still hot there is available warm air to circulate. As the heat is conducted away from the heat exchanger the bimetal detects the temperature drop and breaks the circuit by opening the contacts.

7.3.4 Student Book © 2005 Propane Education & Research CouncilPages 3 & 4 Fan Time Delay (Timer) Relay Controls. The major advantage of the time delay relay is that a heat sensitive fan control does not necessarily have to be used in the circuit. Time delay relays are normally constructed of a flat bimetal with an attached contact, a stationary contact, and a length of high resistance wire. The style of bimetal and the type of resistance wire determines the delay time of the time delay relay. Time delay relays are commonly available with time delays from 15 seconds to 300 seconds, though 120 seconds is a widely used time delay relay. A time delay relay will commonly delay the opening of the contacts (sensor cool down period) as long as it delayed the closing of the contacts.

7.3.4 Student Book © 2005 Propane Education & Research CouncilPages 5 & 6 Time to See If You Got the Key Points of This Module… Complete the Review on page 5. See if you are ready for the Certification Exam by checking off the performance criteria on page 6.