Overbrook Scientific.

Slides:



Advertisements
Similar presentations
Chem. 231 – 3/4 Lecture. Announcements I Set 1 Lab Reports –Both Lab Reports due 3/13 –Only one of the lab reports needs to be detailed, the other can.
Advertisements

Gas Chromatography Introduction 1.) Gas Chromatography
Gas Chromatography 427 PHC.
Jace James & Lauren Erland.  Separation based on charge & frictional force Capillary Electrophoresis (CE)
QA/QC Workshop ‒ Hydrocarbon Analysis Mobile, AL ‒ Jan 26, 2014 QA/QC in Organic Matter (Hydrocarbon) Analysis. Why? Millions of individual compounds with.
Analyzing Small Molecules by EI and GC-MS
Samples that make labs shudder Carl M Smits Technical Director, Evergreen Analytical Laboratory, Inc.
Hit “esc” to quit hit any key to continue Analysis of Beverages using Large Volume Static Headspace / GCMS.
Mass Spectrometer Autosampler Jake Ahrens Stephen Pearson Kyle Sala Seth Yellin Project Mentor: Professor Jane Hill.
Mobile phase is a gas! Stationary phase could be anything but a gas
GreenPatch Permanent Pothole & Patch Repair Cold Asphalt Paving the way to go GREEN GreenPatch Europe Limited ww.greenpatcheurope.co.ukww.greenpatcheurope.co.uk.
Presented by: Kyle F. Gross AWAL Laboratory Director
Analysis of Residues. Laboratory Analysis of Debris and Other Samples 1. Preparation of Liquid Samples: Liquid samples are simply drawn into a special.
Hillcrest Community Environmental Investigation No Conflict of Interest Geo Strata is not affiliated with and does not hold contracts with the oil & gas.
Laboratory Tests for Petroleum Pre ME tests: TPH by EPA SW s Gasoline and Fuel Oil: DEP and Gasoline and Fuel Oil: DEP.
Chem. 231 – 2/4 Lecture. Announcements I Homework Set 1 is due 2/6 New Set will be available 2/6 (hopefully) which will be due 2 weeks later Quiz 1 on.
Melissa Eubanks Chem 4101 December 9,  Silicones are widely used in the personal care and cosmetics industry  Studies suggest D 4 potentially.
. Las Vegas Isotope Science Laboratory University of Nevada Las Vegas.
.
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Methods Monitoring Polar Compounds Using Membrane Extraction and High-Speed Gas Chromatography Authors: Jonathan Maurer, Dr. Anthony J. Borgerding* Department.
.
Comparison and classification of methamphetamine seized in Japan and Thailand using gas chromatography with liquid-liquid extraction and solid-phase microextraction.
Solution Preparation. is a solution preparation system that automatically calculates and dispenses the exact amount of solvent required to prepare a precise.
Introduction to the HPLC ChemStation and Acquisition.
Extraction Methods Static Headspace (HS) Dynamic Headspace
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Chem. 231 – 4/8 Lecture. Announcements Set 1 Lab Reports –hand back Set 2 Lab Reports –Due 4/10 Final Exam – April 15 th Future Mondays (after 4/15) –Set.
ASTM WK Standard Test Method for Dissolved Gases Anne Jurek – Applications Chemist.
April , 2007 The Effect of Temperature on the Uptake Rates of a New PDMS-Based Permeation Passive Sampler for VOCs in Air Suresh Seethapathy, Tadeusz.
 Introduction  Theory  Advantages/Disadvantages  Applications  Conclusions.
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
A Single Calibration for Waters and Soil Samples Performing EPA Method 8260 Anne Jurek – Applications Chemist.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
EVol ® Introducing the Worlds First Digitally-Controlled Analytical Syringe Everyone an Expert.
900-LC P. van Poppel – Field Support Specialist October 2009.
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
Application of solid-phase microextraction to the recovery of explosives and ignitable liquid residues from forensic specimens K.G. Furton, J.R. Almirall,
MICROLAB 600 Diluter & Dispenser
HPLC Introduction & Safety P. van Poppel – Field Support SpecialistMarch 2010.
Analysis of 18 Polycyclic Aromatic Hydrocarbons using a Varian 920-LC Analytical HPLC and Pursuit ® 3 PAH Column By Phuong Truong Varian Australia Pty.
HPLC – High Performance Liquid Chromatography
High Resolution Site Characterization of 1,4 Dioxane Sites using a New On-site, Real-time Analysis William M. Davis, Christopher P. Antworth and Christopher.
RIGHT SOLUTIONS | RIGHT PARTNER HRMS Centre of Excellence Brief introduction of the HRMS laboratory.
Waters HPLC Competitive Review
1/16/2016The GC-in-a-PC 1 Pneumatic Focusing Gas Chromatography PFGC Robert O’Brien, Portland State Univ. & VOC Technologies The GC-in-a-PC Development.
Micro Analytical GC System for Tea Aroma in Product Quality Control Fred Lewis, Principal Chemist, Analytical Science Laboratory, Unilever John Crandall,
Providing comprehensive scientific resources to environmental clients worldwide. Dissolved Gas Analysis: A Review and Comparison.
HPLC.
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
G.A.S. Gesellschaft für analytische Sensorsysteme mbH - Trace Detection of VOCs in different Applications using Gas Chromatography - Ion Mobility Spectrometry.
Introduction to Gas Chromatography
Gas Chromatography Gas Chromatography Effendy De Lux Putra.
Robert Kettner Determination of the Relevant Impurity Toluene in Formulations by Headspace Gas Chromatography and Flame Ionisation or Mass Spectrometric.
Optimization of 1,4-Dioxane and Ethanol Detection
Determination of Algae Compounds in Drinking Water
Automation of Solid Phase Extraction Column Chromatographic Cleanup
Update on Improvements to Dissolved Hydrocarbon Gases in Water Analysis Mark Bruce Ph. D. August 10, 2017.
Evaluation and Application of SPME Arrows
Improved Accuracy of Dissolved Hydrocarbon Gas Analysis in Water
524.3 Purge Flow Study Anne Jurek – Sr. Applications Chemist
Deyuan Kong, Brian Morlan, Roopa Kamath, and Sara Mcmillen
Extraction Procedure (2)
VAPOUR PHASE CHROMATOGRAPHY
Mageleka MagnoMeter™ XRS
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
High performance liquid chromatography (HPLC)
David Thornton1, Xiqin Yang1, Gary Yanik2 and Leo Hsu1*
Presentation transcript:

Overbrook Scientific

Overbrook Scientific Providers of Analytical Instrumentation Providers of Instrument Support and Peripheral Services Distributors of the HTA Line of Autosamplers

HTA Autosamplers HT300A Liquid Sampler HT200H Headspace Sampler HT250D Liquid/Headspace Sampler HT280T (SPME) Headspace Sampler

HTA Autosamplers “High Throughput Automation” Manufactured in Italy Reputation for quality workmanship

Overbrook Collaborations Restek Phenomenex Rapid Tech

HT300A Liquid Autosampler

HT 300A - Key Features Replacement sampler- any major manufactured GC Extremely Rugged Rotating Turret Design No picking up of the vial Handles Front and Back Injectors Small footprint Economical - $8,500 Accurate – Reproducibility Typically .3% Very Easy to use Nice Looking (Italian) Control Software Available including Agilent Chemstation

Headspace

Headspace Europeans to date have a higher level of proficiency due to experience More Widely Used More Widely Accepted Blood Alcohol Residual Solvents Environmental R&D

Advantages of Headspace in the Environmental Laboratory Pre-screening for VOC’s – Aqueous and Solids EPA 8260 Aqueous and Solids Methods 624 Waste Water, 524 Drinking Water Why Gamble on Sample Throughput? Protecting a Lucrative Revenue Stream Decrease Downtime From Contamination Protect your MS System and Sustain Productivity by Pre-screening

HT200H Headspace Autosampler

HT200H Headspace Sampler Key Features Cost effective ($17,900) Inexpensive to Operate Small Footprint Rotating Turret Front and Back Injectors - Run Multiple Methods Direct Injection – No Transfer Line Leaves Inlet Intact No Carryover Very Short Runtime (under 10 min. Including Naphthalene)

HT250D Dual Autosampler

HT250D Dual Autosampler Headspace and Liquid Autosampler in one unit All the features of HT200H plus features of HT300A Easy to change from one mode to the other All included – no optional extras Maximizes the throughput on individual GC’s Small Footprint Most Economical Dual Unit on the Market

Headspace Methods

EPA Method 8260 Pre-screening Volatiles partition into vial headspace 1ml gas-tight syringe injection GC/FID System Use reduced compound list or reference calibration (aromatic and chlorinateds) Dilute appropriately and run by P&T/GC/MS

Prescreening

Method RSK 175 An umbrella EPA Method for permanent gas analysis USEPA Region 1 application notes applied to MNA Standards readily available from Scott & Restek Analyze Methane/Ethane/Ethene to 2ug/L Remember Methane is a Reportable Compound in MA

Methane Ethane Ethene

CCME Method 1310 Canadian Petroleum Hydrocarbon Method for VPH/GRO Performance based method allows for Headspace Preparation to reduce carryover contamination PBM Criteria require strict alkane/ aromatic ratios Pre-screen UST Samples – no reruns for baseline resolution issues

Volatile Petroleum

Business Opportunities with Headspace

Business Opportunities with Headspace CCME 1310 Materials Testing USP 467 Residual Solvents Raw Materials from China VOA’s (Raw production Material that cannot be prepared by P&T)

Thank You