R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.

Slides:



Advertisements
Similar presentations
Prototype sPHENIX Calorimeters
Advertisements

New calorimetric technology for eRHIC. O.Tsai (UCLA) BNL, March 9, 2010 Updated, June 1, 2010.
1 ALICE EMCal Electronics Outline: PHOS Electronics review Design Specifications –Why PHOS readout is suitable –Necessary differences from PHOS Shaping.
Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
New Technology for Scintillating Fiber Calorimeters. O.Tsai (UCLA)
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
New Technologies for SciFi Calorimeters. O.Tsai (UCLA) Dec.14, 2010.
An SiPM Based Readout for the sPHENIX Calorimeters Eric J. Mannel IEEE NSS/MIC October 30, 2013.
SoLID EC Design for IHEP 2012/10. Basic Features of Preliminary Design Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm.
CMS Outer Hadron Calorimeter (HO) Project Naba K Mondal Tata Institute, Mumbai, India.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Homework Questions for eRD1 EIC R&D Committee Meeting January 23, What are the concrete plans of eRD1 for the next two years? What are the deliverables.
Status of R&D on Calorimetry for EIC EIC Detector R&D Committee Meeting June 5, 2013 The EIC Calorimeter R&D Consortium Contact Persons: H.Z. Huang
Fiberless Coupled Tiles for a High Granularity Scintillator-SiPM Calorimeter Rick Salcido Northern Illinois University November 14, 2009 Prairie Section.
E.Kistenev History lessons Specification Primary options e-RHIC meeting at BNL, Sept 19th, 2002 Hermetic Calorimeter for e-RHIC collider experiments.
02/10/2004 Minimum Bias Trigger Scintillator Counters (MBTS) for early ATLAS running M.Nessi ATLAS week, Freiburg.
GlueX Simulations Status Report on CD3 geometry Richard Jones GlueX Collaboration Meeting, Newport News, January 10-12, 2008.
Doug Michael Jan. 12, First goal is to be ready to select an optimal technology in ~one year. –Demonstrate that fundamental technologies are ready.
Calorimeters A User’s Guide Elizabeth Dusinberre, Matthew Norman, Sean Simon October 28, 2006.
The sPHENIX Barrel Upgrade: Jet Physics and Beyond John Haggerty Brookhaven National Laboratory on behalf of the PHENIX collaboration Quark Matter 2012.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
1 C.Woody BNL Summary of the Calorimetry Session PHENIX Upgrade Workshop Dec 14-16, 2010 PHENIX Collaboration Meeting January 11, 2011.
C.Woody BNL sPHENIX EMCAL Conceptual Design sPHENIX Design Study Meeting September 7, 2011.
Heavy Scitillating Crystals and Glasses for a Combined EM and HCal at ILC Tianchi Zhao University of Washigton Sept. 25, 2007.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
Technology Choices for the sPHENIX Calorimeter Systems C.Woody For the PHENIX Collaboration CALOR12 Santa Fe, NM June 5, 2012.
ERD1 Homework assignment 1. Please provide a prioritized list of the proposed projects. 1. Ongoing BEMC R&D (Crystals, W/ScFI) 2. SiPM tests and evaluations.
Calorimetry: a new design 2004/Sep/15 K. Kawagoe / Kobe-U.
Development of New Detectors for PET Imaging at BNL DOE/JLAB Meeting Bethesda, MD May 20, 2004 Craig Woody Physics Dept Brookhaven National Lab RatCAPBeta.
Detector development and physics studies in high energy physics experiments Shashikant Dugad Department of High Energy Physics Review, 3-9 Jan 2008.
Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
E.Kistenev Large area Electromagnetic Calorimeter for ALICE What EMC can bring to ALICE Physics and engineering constrains One particular implementation.
T. Sugitate / Hiroshima / PHX031 / Nov.01 The Photon Spectrometer for RHIC and beyond PbWO 4 Crystal Density 8.29 g/cm 3 Radiation length 0.89 cm Moliere.
Tungsten as HCal-material for a LC at multi-TeV energies CALICE AHCAL Meeting, DESY 17 July 2009 Christian Grefe for the Linear Collider Detector Group.
SiD R&D tasks for the LOI - Subsystem R&D tasks - Summary of SiD R&D - Prioritization of R&D tasks -> Document for DoE/NSF ~Feb 2009 (Mainly based on Marty’s.
ECAL PID1 Particle identification in ECAL Yuri Kharlov, Alexander Artamonov IHEP, Protvino CBM collaboration meeting
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
TPC/HBD R&D at BNL Craig Woody BNL Mini Workshop on PHENIX Upgrade Plans August 6, 2002.
R.S. Orr 2009 TRIUMF Summer Institute
A Silicon Photomultiplier (SiPM) Based Readout for the sPHENIX Upgrade S. Boose, J. Haggerty, E. Mannel, A. Sukhanov For the PHENIX Collaboration Introduction:
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
SPHENIX EMCAL R&D Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Calorimeters Design Issues and Simulation Needs C.Woody Physics Department Brookhaven National Lab EIC Simulation Workshop Oct 9, 2012.
Edouard Kistenev for the PHENIX Collaboration Calorimetry based upgrade to PHENIX at RHIC CALOR 2012 Santa Fe, NM, June 4-8, 2012.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
Jet Energy Measurement at ILC Separation of jet particles in the calorimeter is required for the PFA  Fine granular calorimeter is necessary. Particle.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Hadron Calorimeter Felix Sefkow EUDET Extended Steering Meeting September 11, 2006.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
SPHENIX Mid-rapidity extensions: Additional Tracking system and pre-shower Y. Akiba (RIKEN/RBRC) sPHENIX workfest July 29,
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
PHENIX detector upgrade PHENIX → sPHENIX NPD RAS session, in Protvino, RUSSIA Nov. 7, 2013 V.Babintsev, IHEP for the PHENIX Collaboration.
Durham TB R. Frey1 ECal R&D in N. America -- Test Beam Readiness/Plans Silicon-tungsten SLAC, Oregon, Brookhaven (SOB) Scintillator tiles – tungsten U.
R&D on a new construction technique for W/ScFi calorimeters. O. Tsai (UCLA), Calor Santa Fe. June 5, 2012.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
Design of a New Electromagnetic Calorimeter for the sPHENIX Experiment at RHIC Craig Woody Brookhaven National Lab For the PHENIX Collaboration CALOR 2014.
Backward Calorimetry For SuperB
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Testbeam comparisons arXiv:
Vishnu V. Zutshi For the NICADD team.
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Mickey Chiu University of Illinois at Urbana-Champaign
Reports for highly granular hadron calorimeter using software compensation techniques Bing Liu SJTU February 25, 2019.
Dual readout calorimeter for CepC
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics Department Brookhaven National Lab EIC Detector R&D Committee Meeting May 17, 2012

Connection with other R&D Efforts at BNL on Calorimetry for EIC C.Woody, EIC Detector R&D Committee, 5/17/12 2 The PHENIX Collaboration is currently pursuing a major new upgrade effort → sPHENIX Main physics goal is to measure jets in heavy ion collisions Includes two new calorimeter systems  Hadronic (first in any experiment at RHIC)  Electromagnetic (W-SciFi accordion) R&D on calorimetry in general is an area of overlap with future interests at EIC, but primarily focus now is on an EMCAL Propose to combine parts of these efforts which would be of specific interest to EIC and not part of the PHENIX R&D plan into this proposal, along with simulation efforts on calorimetry for EIC from the BNL SPIN/EIC Group

C.Woody, EIC Detector R&D Committee, 5/17/12 3 HCAL Outer HCAL Inner EMCAL Solenoid VTX Coverage ± 1.1 in  and 2  in  EMCAL: R inner =95 cm, T ~ 10 cm, L = 2.8m

sPHENIX EMCAL Requirements C.Woody, EIC Detector R&D Committee, 5/17/12 4  E/E ~ 18%/√E (~ 1 X 0 sampling) - want much better resolution for EIC Need high segmentation for central heavy ion collisions - not as strong a requirement for EIC Energy range up to ~ 50 GeV in the central region for jets - may be similar for EIC, although generally lower E Must be compact (small Moliere radius, short radiation length) - small size  low cost Tungsten scintillating fiber accordion satisfies these requirements - new technologies with tungsten materials makes this possible Readout must work inside a magnetic field - silicon photomultipliers are the preferred option

Optical Accordion Calorimeter 5 Accordion design similar to ATLAS Liquid Argon Calorimeter Volume increases with radius Scintillator thickness doesn’t increase with radius, so either tungsten thickness must increase or the amplitude of the oscillation must increase, or both Plate thickness cannot be totally uniform due to the undulations Small amplitude oscillations minimize both of these problems Want to be projective in both r-  and  C.Woody, EIC Detector R&D Committee, 5/17/12

Sintered Tungsten Plates 6 Variable thickness W-plates Scintillating fibers in between Density  ~ 17.5 g/cm 3 Problem is that cannot make sintered plates larger than ~ 20 cm Phase I SBIR with 20 cm C.Woody, EIC Detector R&D Committee, 5/17/12

Tungsten SciFi Epoxy Sandwich 7 Scintillating fibers ~ 0.5 – 1.0 mm Pure tungsten metal sheet (  ~ 19.3 g/cm 3 ) Thickness ~ mm Tungsten powder epoxy (  ~ g/cm 3 ) Uniform thickness, thin pure tungsten metal sheets with wedge shaped SciFi + tungsten powder epoxy layer in between Can be made into larger modules (> 1m) C.Woody, EIC Detector R&D Committee, 5/17/12

Readout and Light Yield 8 Want to have small photostatistics contribution to the energy resolution Need sufficient light output from fibers to allow randomizing and collecting the light onto a small readout device SiPM Scintillating Fibers Small reflecting cavity or wavelength shifting block Possible Readout Schemes C.Woody, EIC Detector R&D Committee, 5/17/12 SiPM direct readout of scintillating tile with “dimple” F.Simon & C.Soldner, NIM A620(2010) Light output from fibers ~ 100 p.e./MeV Consistent with UCLA beam test measurement

Readout Devices & Electronics 9 C.Woody, EIC Detector R&D Committee, 5/17/12 Considering two types of readout devices: SiPMs and APDs SiPMs Higher gain (~10 6 ) High noise (~ few MHz/mm 2 at ~ 1 p.e. level) Sensitive to temperature and voltage G ~ (V op -V br ), V br varies with T (~50 mV/°C  dG/dT ~ 10% /°C) Limitation on dynamic range due to finite number of pixels Need to “tune” light level to stay within “linear” range New SiPMs being developed (AdvanSiD, Zecoteck,…) with more pixels/mm 2 and (hopefully) high PDE APDs Gain ~ Better linearity dG/dV ~ 3%/V, dG/dT ~ 2% /°C Hamamatsu S C 3x3 mm K 25  m pixels Readout electronics must be designed to match SiPM – high gain  don’t need ultra low noise electronics (currently being developed within PHENIX) APD – requires higher gain, lower noise front end Both will require temperature stabilization and gain monitoring

R&D Goals for this Proposal 10 Develop W-SciFi technology that would allow building a high resolution electromagnetic calorimeter that is specifically optimized for EIC. Utilize parts of the R&D program within the PHENIX Collaboration, which is exploring similar technologies for sPHENIX, to leverage the effort on this design Note: The R&D for EIC would focus only on work that would not be done within the context of the PHENIX effort. Study techniques to build modules with finer sampling and/or higher sampling fraction using the layered sandwich technique that would achieve the best possible energy resolution Study readout schemes to optimize the light levels for different readout devices (SiPMs and APDs) that would be most suitable in terms of gain, linearity and dynamic range for the energy range at EIC Develop the readout electronics that would best match the calorimeter design and readout scheme that would be optimized for EIC Generate simulation results to provide feedback and guidance on the calorimeter design C.Woody, EIC Detector R&D Committee, 5/17/12

R&D Plan 11 Year 1 Study and develop a high resolution EMCAL module design using the layered sandwich technique that is optimized for EIC applications 1.Fabricate and test module layers with finer sampling and/or higher sampling fraction (e.g., using thinner tungsten plates, smaller diameter fibers, etc.) 2.Study methods for embedding fibers that allow projective module construction 3.Study light collection and mixing schemes that allow the use of either a single or limited number of readout devices which provide sufficient photostatistics 4.Develop the readout electronics to read out the device(s) used with the light mixer(s) 5.Build several high resolution modules using the optimized designs from (1-4) Year 2 Construct one or more full scale prototype modules with a high resolution design and fully characterize them in a test beam Modules ~ 20 x 20 cm 2 x 10 cm deep (10 x 10 towers) Build readout electronics for prototype modules Carry out beam tests in collaboration with the UCLA/TAMU/PSU group C.Woody, EIC Detector R&D Committee, 5/17/12 Simulation results and feedback are provided throughout years 1 and 2

Budget 12 Note: Funding request is for items that would not be covered as part of the PHENIX R&D effort or the SBIR with Tungsten Heavy Powder C.Woody, EIC Detector R&D Committee, 5/17/12