1 Electrical Safety- Related Work Practices In and around the mines AND The home.

Slides:



Advertisements
Similar presentations
Hazards Of Electricity
Advertisements

Electrical Safety 1926 Subpart K ‑ Electrical
OSHA Office of Training and Education - Revised by TEEX 12/05/07
Electrical Safety.
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Electrical Safety 29 CFR I. Background for the Trainer:
ELECTRICAL SAFETY-RELATED WORK PRACTICES Qualified Persons Those people that have training in avoiding electrical hazards while working on or near exposed.
CHEM 521 Safety Presentation. Hazard Symbols You Must Know.
1 Hazardous Energy Module 5. 2Objectives After this module you should be able to – identify the most common energy hazards – take the necessary steps.
Electrical Safety for Construction. Electrical regulations v Subpart K of 29 CFR a.
By: Aseem Aggarwal. Causes of Electrocution Fatalities Contact with Overhead Power lines Contact with Live Circuits Poorly Maintained Extension Cords.
OSHA Office of Training and Education
Young Worker Safety Resource Center, adapted from OSHA Office of Training and Education Electrical Safety.
When working on or near electricity or electrical equipment you must be trained in & use Electrical Safety Related Work Practices NFPA.
Electrical Safety Awareness Un-Qualified
ELECTRICAL SAFETY Safety Training for the Non-Qualified.
OSHA Office of Training and Education
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
Union College EHS Training 1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical.
Electrical Safety 29 CFR Concerned About Electricity? How many sets of Christmas lights do you plug into one extension cord? Do you still use.
Electrical Safety This material was produced under a grant (SH22249SH1) from the Occupational Safety and Health Administration, U.S. Department of Labor.
Electrical Safety - Construction. Electricity - The Dangers About 5 workers are electrocuted every week Causes 12% of young worker workplace deaths Takes.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Electrical Safety Safety Training Series
Safety Training For The Non-Qualified
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
North Slope Training Cooperative © North Slope Training Cooperative—revised May All rights reserved. Electrical Safety for Non- Electrical Workers.
ELECTRICAL SAFETY Part 2: Working Safely.
Electrical Safety.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety. Defective Insulation To protect you, electrical wires are insulated by a plastic.
Electrical Safety Training
Electrical This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are.
Copyright  Business & Legal Reports, Inc. Electrical Safety 29 CFR BLR’s Safety Training Presentations.
Electrical Safety INSTRUCTOR’S NOTES:
1 Electrical Safety. 2 Electrical Hazards & OSHA 29 CFR (b)(1) requires: “Electrical equipment shall be free from recognized hazards that are.
Electrical Safety INSTRUCTOR’S NOTES:
HU151 Lecture 6 Electrical Safety Fall 2012/2013.
Electrical Safety.
Basic Electrical Safety
Copyright  Progressive Business Publications Electrical Safety.
1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:  Electrocution.
Electricity. Electricity Electric shock happens when a person becomes part of an electrical circuit and the current flows through their body. When an.
1a.  Exposed part  Live or energized part  De-energized part 1a.
Accommodation & Hospitality Services STAFF BRIEFING – No 16 Electrical Safety.
Shop Safety Electrical Hazards….  Even small electric shocks are dangerous  Many hazards include electrocution, fire, or explosions  Even small electric.
SAFETYSAFETY. Overview ●Introduction to Safety ●Potential Electronic Mishaps ●Safe Work Practices.
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
Pennsylvania Bureau of Deep Mine Safety Lockout/Tagout Program.
Electrical Safety, Subpart K
1 AS OF:141330DEC15 UNCLASSIFIED OPR: 8A 8A Safety Electrical Safety Awareness Training Note: This training meets the General Electrical Safety Awareness.
 A medium that provides a means for transferring energy from one place to another  It is not expensive or difficult to control the risk of an electrical.
ELECTRICAL SAFETY. OSHA Office of Training & Education Electrical Safety.
CHEM 421 Safety Presentation. Hazard Symbols You Must Know.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
ELECTRICAL SAFETY in the Lab. 1.Electricity takes the path of least resistance. 2.Electricity wants to go to ground. 3.If an electrical appliance or tool.
BASIC ELECTRICAL SAFETY. INTRODUCTION PURPOSE: To provide employees with safe work practices & procedures to prevent an electrical accident or injury.
Electrical Safety and Safe Work Practices
Electrical Safety OSHE 382, Spring 2016
ELECTRICAL SAFETY! It’s shocking! OSHA 29 CFR
Basic Electrical Safety
Subpart K Electrical Long recognized as a serious hazard.
Personal Protective Equipment
Electrical Safety.
ANNUAL REFRESHER – electrical hazards SURFACE 2015
Basic Electrical Safety
Basic Electrical Safety
Presentation transcript:

1 Electrical Safety- Related Work Practices In and around the mines AND The home

2 Jon Montgomery, EFS Albany, NY

3 WHAT IS ELECTRICITY??

4 ? Electricity is a form of energy High Voltage (>650 volts) Low Voltage (650 volts or less) Alternating Current Direct Current Static Electricity

5

6

7

8

9 ELECTRICAL ACCIDENTS Electrocutions rank fourth in work related fatalities with about half of these at 600 volts or less. There are an average of over 3,600 disabling electrical related injuries annually. There are an average of 4,000 non- disabling electrical injuries annually.

10 Let’s talk about personal protection and the home 40,000 residential fires annually which are caused by problems with electrical wiring systems, claiming more than 350 lives Additionally, electric cords and plugs were involved in about 7,100 fires resulting in 120 deaths or about 32% of all deaths associated with residential electrical system fires, occurring each year. Lamps and light fixtures were involved in about 8,900 fires and 60 deaths About 3,600 people are treated for injuries associated with extension cords. Switches and outlets are involved in 4,700 fires and deaths

11 Coal-Underground752 Coal-Surface 137 Metal/non-metal-Underground 99 Metal/non-metal-Surface655 Prep Plants244 Other 34 Total1921 Reported Mining Electrical Accidents (INCLUDES FATALITIES) 1990 thru 2000

12 Fatal Electrical Accidents 1990 thru 2000 Coal-Underground 27 Coal-Underground 27 Coal-Surface 4 Coal-Surface 4 Metal/non-metal-Underground 7 Metal/non-metal-Underground 7 Metal/non-metal-Surface 29 Metal/non-metal-Surface 29 Prep Plants 9 Prep Plants 9 Other 2 Other 2 Total 78 But more important is the cost in lives……

13 Causes of Electrical Injuries Touching live parts. Short circuit Accidental ground Overload

14

15 Electrical Hazards Exposed conductors Frayed and worn insulation Exposed bus bars and connections Overloaded circuits Modified circuits Removed grounding plug Jury-rigged connections

16 Effects on the Body Burns Flash burns (from electrical arcs) Electrical burns (entry & exit wounds) Electrical Shock Damage to internal organs and body systems

17 Effects on the Body Approximately 50 volts is needed to overcome skin resistance Resistance is higher on dry skin Resistance is lower on wet skin

18 ENTRY WOUND

19 EXIT WOUND

20

21 A person receives an electrical shock whenever any part of his/her body becomes part of the electrical circuit through which a sufficient current flows to cause discomfort or worse. Current flow slightly above this threshold is sufficient to cause discomfort:  May cause involuntary contraction of the muscles.  Stop the heart.  Stop breathing.  Cause burns. Electrical Shock

22 Electrical Shock The amount of current that flows through the victim’s body will depend on: The voltage of the circuit with which he/she is in contact. The insulating qualities of the place in which he/she is located at the instant. The resistance of skin or clothing or both. The area of contact with the live conductor. The pressure of contact with the live conductor. The area of contact with the live conductor

23 four major components of an electrical system sources conductors loads switches

24 SOURCES provide electricity batteries transformers generators water system equivalent - water tank

25 CONDUCTORS carry electricity wires cables bus bars water equivalent - pipes

26 LOADS use electricity motors pumps fans hand tools lights heaters water equivalent -water wheel

27 SWITCHES control electricity floats push buttons disconnects duplex outlets / plugs water equivalent - valves

28 Water system comparison Current = flow Resistance = system resistance to flow Voltage = pressure

29 Ohms Law amps Since voltage is constant, current flow depends on resistance voltage resistance

30 30 CFR 56/ / Testing grounding systems. Continuity and resistance of grounding systems shall be tested immediately after installation, repair, and modification; and annually thereafter. A record of the resistance measured during the most recent tests shall be made available on a request by the Secretary or his duly authorized representative.

31 Equipment grounding systems high resistance = low current low resistance = high current current flow is what trips fuses/breakers

32 Be sure: all grounds ohms values are as low as possible all wiring connections are clean & tight all conduit connections are clean & tight all plugs have ground prong in place

33 Methods of Contact Step potential Difference in voltages (potential for current flow) between person’s feet Touch potential Difference in voltages between points of contact (usually hands and/or feet)

HOW DO WE PROTECT OURSELVES???? LOCK OUT- TAG OUT!!

35 LOCKOUT/TAGOUT Types of Devices

36 LOCKOUT/TAGOUT Types of Energy Mechanical Hydraulic Pneumatic Chemical Thermal Other

37 LOCKOUT/TAGOUT Preparation for Shutdown Know the types and amounts of energy that power it. Know the hazards of that energy. Know how the energy can be controlled.

38 VERIFY-VERIFY-VERIFY!!!! (ONLY IF YOU ARE QUALIFIED)

HOW ELSE CAN WE PROTECT OURSELVES??? BY USING GFCI’S

40 How does the GFCI work GFCIs constantly monitor electricity flowing in a circuit. If the electricity flowing into the circuit differs by even a slight amount from that returning, the GFCI will quickly shut off the current flowing through that circuit. The advantage of using GFCIs is that they can detect even small variations in the amount of leakage current, even amounts too small to activate a fuse or circuit breaker. GFCIs work quickly, so they can help protect consumers from severe electric shocks and electrocution.

41 Some things a GFCI does not protect you from. A GFCI does not protect a person who comes in contact with two hot wires or any hot wire and the neutral wire. A GFCI does not protect a person from feeling and reacting to shock

42 ALWAYS REMBER! Never work on a Energized Circuit. Unless you are trained to. Always Lock and Tag Never depend on another person to take the power off a circuit that you are going to work on. Its your Life! This should even apply to home. Just remember that Half of what you have is hers.

43 Qualified Employees “One knowledgeable in the construction and operation of the electric power generation, transmission, and distribution equipment involved, along with the associated hazards.” Qualified employees must have training to be considered qualified.

44 Qualified Employees Qualification extends to individual tasks Employees can be qualified in one task, but not in another. Examples: Racking breakers in & out Changing fuses Substation switching

45 Unqualified Employees Unqualified employees and mobile mechanical equipment must maintain a safe distance from energized circuits Overhead power lines Unguarded, exposed, energized conductors 10 feet up to 50,000 volts Additional 4 inches for every 10,000 volts over 50 kV

46 Methods of Protection Insulation Verify insulation is intact Pay particular attention to flexible cords, such as extension cords and tool power cords

47 Methods of Protection Guarding Live parts operating at 50 volts or more must be guarded Locate in a room or vault accessible only by qualified persons Permanent partitions or walls  Metal-clad switchgear required if over 600 volts Distance  8 feet (or more) above the floor Warning Signs

48 Methods of Protection Grounding Service ground Neutral conductor is grounded Equipment ground Frame or casing of tool or equipment is wired directly to ground.

49 Methods of Protection Circuit Protection Devices Fuses and Circuit Breakers Designed for equipment protection Open circuit on high current GFCI Ground Fault Circuit Interrupter Designed for personnel protection Opens quickly (1/40 second) on any ground fault

50 Methods of Protection Safe Work Practices De-energize Lockout/Tagout energy sources Use electric tools that are in good repair Do not perform work you are not qualified for Use appropriate protective equipment FR clothing, non-conductive hard hats, rubber mats, line hose, hot sticks, rubber gloves, safety glasses, face shields, etc.

51 Methods of Protection Overhead Lines Only qualified employees can work on or near All others maintain 10-foot rule, or Owner/operator must de-energize and ground lines prior to work

52 Safe Work Practices DO Inspect cords for damage De-energize and L.O.T.O. Keep cords off walkways Wear PPE Perform work only if qualified Use a GFCI DON’T Overload plugs Upsize fuses, or use substitutes Lay cords in water Use defective equipment Assume household current is safe Use conductive ladders

53 IF SOMEONE CONTACTS AN ENERGIZED CONDUCTOR ---- WHAT SHOULD ONE DO ??

54 BLOOD TESTS TO WARN OF FIBRILLATION TO OCCUR TROPONIN CPK ISOENZYME (CREATINE KINASE)

55 PLEASE REMEMBER---

56 SAFETY FIRST!!!!

57 THANK YOU ALL FOR LISTENING!!!