O. Pirali, S. Gruet, M. Vervloet AILES beamline, synchrotron SOLEIL

Slides:



Advertisements
Similar presentations
Production of Molecular Ions Using a Hollow-Cathode Spectrometer Trevor Cross, Nadine Wehres, Mary Radhuber, Anne Carroll, Susanna Widicus Weaver Department.
Advertisements

Submillimeter-wave and far-infrared spectroscopy of high-J transitions of ammonia S. Yu, J.C. Pearson, B.J. Drouin and K. Sung Jet Propulsion Laboratory,
Gabriel M. P. Just, Patrick Rupper, Dmitry G. Melnik and Terry A. Miller EXPERIMENTAL PROGRESS FOR HIGH RESOLUTION CAVITY RINGDOWN SPECTROSCOPY OF JET-
Tessa Charles Australian Synchrotron / Monash University 1 Bunch Compression Schemes for X-band FELs.
Coherent Radiation from High-Current Electron Beams of a Linear Accelerator and Its Applications S. Okuda ISIR, Osaka Univ Research Institute.
Coherent Synchrotron Radiation for Rotational Spectroscopy : application to Propynal in the GHz range J.Barros P.Roy L.Manceron SOLEIL - AILES.
A L INE L IST FOR H YDROGEN S ULPHIDE (H 2 S) Ala’a A. A. Azzam J. Tennyson and S. Yurchencko Department of Physics and Astronomy, University College London,
High-Lying Rotational Levels of Water obtained by FIR Emission Spectroscopy L. H. Coudert, a M.-A. Martin, b O. Pirali, b D. Balcon, b and M. Vervloet.
Jerry Blazey NICADD/NIU UCLC NICADD/NIU Accelerator R&D Proposal* Two Component Program : Benchmark flat-beam simulation codes vs. FNPL experiments. -
Spatial profiles of copper atom density in a Cu/Ne hollow cathode discharge P. Hartmann*, T.M. Adamowicz**, E. Stoffels and W.W. Stoffels, Department of.
Generation of narrowband terahertz radiation at DELTA
LINE PARAMETERS OF WATER VAPOR IN THE NEAR- AND MID-INFRARED REGIONS DETERMINED USING TUNEABLE LASER SPECTROSCOPY Nofal IBRAHIM, Pascale CHELIN, Johannes.
3 – 3.5  MIR CRDS 1 – 1.5  NIR CRDS  m -HV O2O2 N2N2 OH X a A B X X ~
The LHC: an Accelerated Overview Jonathan Walsh May 2, 2006.
Electromagnetic radiation sources based on relativistic electron and ion beams E.G.Bessonov 1.Introduction 2.Spontaneous and stimulated emission of electromagnetic.
11 The THz spectrum of GlycolAldehyde M. Goubet, T.R. Huet, I. Haykal, L. Margulès PhLAM, CNRS – Université de Lille 1 O. Pirali, P. Roy AILES beamline,
High Resolution Measurements and Electronic Structure Calculations of a Diazanaphthalene: [1,6]-naphthyridine. Sébastien Gruet, Manuel Goubet, Olivier.
Modelling the photon transport system of the ALICE FEL using wavefront propagation Mark D Roper Accelerator Science & Technology Centre STFC Daresbury.
Far-Infrared Beamline at the Canadian Light Source Brant E. Billinghurst, Tim E. May 69 th International Symposium on Molecular Spectroscopy.
Emission Spectra of H 2 17 O and H 2 18 O from 320 to 2500 cm -1 Semen MIKHAILENKO 1, Georg MELLAU 2, and Vladimir TYUTEREV 3 1 Laboratory of Theoretical.
Sub-Doppler Spectroscopy of Molecular Ions in the Mid-IR James N. Hodges, Kyle N. Crabtree, & Benjamin J. McCall WI06 – June 20, 2012 University of Illinois.
69 th International Symposium on Molecular Spectroscopy / Champaign-Urbana, Illinois, USA, June 16–20, 2014 HIGH-RESOLUTION INFRARED SPECTROSCOPY OF CUBANE,
Ultrafast carrier dynamics Optical Pump - THz Probe Ultrafast carrier dynamics in Br + -bombarded semiconductors investigated by Optical Pump - THz Probe.
Introduction to Synchrotron Radiation
Synchrotron-Based High Resolution Spectroscopy of N-Bearing PAHs Sébastien Gruet, Olivier Pirali, Manuel Goubet and P. Bréchignac ISMS /06/2014.
68th Ohio State University Symposium on Molecular Spectroscopy June 17–21, 2013 SF 6 THE FORBIDDEN BAND UNVEILED V. BOUDON, Laboratoire Interdisciplinaire.
66th OSU International symposium on molecular spectroscopy
Precision Measurement of CO 2 Hotband Transition at 4.3  m Using a Hot Cell PEI-LING LUO, JYUN-YU TIAN, HSHAN-CHEN CHEN, Institute of Photonics Technologies,
New 12 C 2 H 2 measurements using synchrotron SOLEIL David Jacquemart, Nelly Lacome, Olivier Piralli 66th OSU international symposium on molecular spectroscopy.
Main Bullet #1 Main Bullet #2 Main Bullet #3 Advances in Coherent Synchrotron Radiation at the Canadian Light Source Jack Bergstrom.
64th Ohio State University Symposium on Molecular Spectroscopy June 22–26, 2009 THE HIGH RESOLUTION FAR- INFRARED SPECTRUM OF METHANE AT THE SOLEIL SYNCHROTRON.
Line list of HD 18 O rotation-vibration transitions for atmospheric applications Semen MIKHAILENKO, Olga NAUMENKO, and Sergei TASHKUN Laboratory of Theoretical.
Observation of Wakefields in Coherent Synchrotron Radiation at the Canadian Light Source W. A. Wurtz CAP Congress, Edmonton, AB.
High-Resolution Visible Spectroscopy of H 3 + Christopher P. Morong, Christopher F. Neese and Takeshi Oka Department of Chemistry, Department of Astronomy.
ELECTRON MOVING AT CONSTANT VELOCITY
High Precision, Sensitive, Near-IR Spectroscopy in a Fast Ion Beam Michael Porambo, Holger Kreckel, Andrew Mills, Manori Perera, Brian Siller, Benjamin.
HIGH RESOLUTION JET COOLED CAVITY RINGDOWN SPECTROSCOPY OF THE A STATE BAND OF THE NO 3 RADICAL Terrance J. Codd, Mourad Roudjane and Terry A. Miller.
HIGH RESOLUTION SPECTROSCOPY OF THE TWO LOWEST VIBRATIONAL STATES OF QUINOLINE C 9 H 7 N O. PIRALI, Z. KISIEL, M. GOUBET, S. GRUET, M.-A. MARTIN-DRUMEL,
How can synchrotron-based FTIR spectroscopy contribute to astrophysical and atmospheric data needs? A.R.W. McKellar National Research Council of Canada,
Beamline AILES : Mid IR to THz Spectroscopy The AILES Infrared and THz High Resolution Spectroscopy beamline at SOLEIL (Saclay, 30 km south of Paris) –
M. Hosaka a, M. Katoh b, C. Szwaj c, H. Zen b M. Adachi b, S. Bielawski c, C. Evain c M. Le Parquier c, Y. Takashima a,Y. Tanikawa b Y. Taira b, N. Yamamoto.
UCLA Positron Production Experiments at SABER Presented by Devon Johnson 3/15/06.
First results from the far-infrared beamline at the Canadian Light Source: High resolution analysis of acrolein in the 600 cm -1 region A.R.W. McKellar.
Copyright All rights reserved. June 25, 2015ISMS, 2015
70 th International Symposium on Molecular Spectroscopy / Champaign-Urbana, Illinois, USA, June 22–26, 2015 LOW-TEMPERATURE COLLISIONAL BROADENING IN THE.
Precision Laser Spectroscopy of H 3 + Hsuan-Chen Chen 1, Jin-Long Peng 2, Takayoshi Amano 3,4, Jow-Tsong Shy 1,5 1 Institute of Photonics Technologies,
OSU International Symposium on Molecular Spectroscopy June 18 – 22, TF Infrared/Raman -- TF01, Tuesday, June 19, 2012.
CH 3 D Near Infrared Cavity Ring-down Spectrum Reanalysis and IR-IR Double Resonance S. Luna Yang George Y. Schwartz Kevin K. Lehmann University of Virginia.
Applications of the VUV Synchrotron SOLEIL.
Time-resolved Fourier transform infrared emission spectra of HNC/HCN K. Kawaguchi & A. Fujimoto Okayama University.
INDIRECT TERAHERTZ SPECTROSCOPY OF MOLECULAR IONS USING HIGHLY ACCURATE AND PRECISE MID-IR SPECTROSCOPY Andrew A. Mills, Kyle B. Ford, Holger Kreckel,
Synchrotron Far Infrared Spectroscopy : Higher resolution and longer wavelengths at the Canadian Light Source A.R.W. McKellar National Research Council.
ICFDT 2009, Frascati Fourier-Transform Infrared Spectroscopic Ellipsometry for Material Identification Michele Ortolani CNR – Istituto di Fotonica e Nanotecnologie.
Development of a Fast Ion Beam Spectrometer for Molecular Ion Spectroscopy Departments of Chemistry and Astronomy University of Illinois at Urbana-Champaign.
Initial Development of High Precision, High Resolution Ion Beam Spectrometer in the Near- Infrared Michael Porambo, Brian Siller, Andrew Mills, Manori.
The Performance Of A Continuous Supersonic Expansion Discharge Source
The Performance Of A Continuous Supersonic Expansion Discharge Source
Mid-IR Direct Absorption/Dispersion Spectroscopy of a Fast Ion Beam
Yeong-Shin Park and Y. S. Hwang
Gas phase rovibrational spectroscopy of DMSO, Part I: « When a synchrotron source reveals an unusual rotational behaviour » Arnaud Cuisset, Dmitrii Sadovskii.
HIGH RESOLUTION SPECTROSCOPY OF THE CARBON CAGE ADAMANTANE C10H16
The Near-IR Spectrum of CH3D
M. VERVLOET, M. A. MARTIN-DRUMEL., D. W. TOKARYK, O. PIRALI
NH3 measurements in the far-IR
University of Arizona, Dept. of Physics
Tokyo Univ. Science Mitsunori Araki, Yuki Matsushita, Koichi Tsukiyama
Brian Siller, Andrew Mills, Michael Porambo & Benjamin McCall
By Narayan Adhikari Charles Woodman
Proposal for Smith-Purcell radiation experiment at SPARC_LAB
Presentation transcript:

FOURIER TRANSFORM FAR-INFRARED SPECTROSCOPY OF HN2+ ON THE AILES BEAMLINE OF SYNCHROTRON SOLEIL O. Pirali, S. Gruet, M. Vervloet AILES beamline, synchrotron SOLEIL Institut des Sciences Moléculaires d’Orsay

Caracteristics of SOLEIL facility Bunch of electrons accelerated in the LINAC to 100 MeV Accelerated in the Booster to 2.75 GeV Injected in the storage ring (113 m diameter) Dipoles, undulators, wiggler to make the electrons « oscillating » Loss of energy throught photon emission Length of a bunch : 10 ps Period between bunches : 10 ns Storage mode : « Top-up » 430 mA « multibunches »: 416 bunches « temporel » : 8 bunches

www.synchrotron-soleil.fr Call for beamtime every 6 months http://sunset.synchrotron-soleil.fr/sun

FIR absorption spectroscopy of transient species PhD Marie-Aline Martin (2012) 14NH2, 15NH2, C3,CH, NH,OH, SH, SO (TD12) PhD Sebastien Gruet HN2+, HCO+, H3+ DC DISCHARGE ~ 1KV / 100mA 24 m absorption White type cell Continuum synchrotron RESOLUTION=30MHz 20-700 cm-1

Schematic view of the hollow cathode discharge cell See e.g. S. Foster et al., J. Chem. Phys., 81,578 (1984) 10 cm Teflon rings Liquid N2 (output) Evacuation Anode 70 cm Gas Injection 110 cm Hollow Cathode Windows Beam 15 cm Liquid N2 (input) Pyrex Cell Technical details Gold mirrors Copper electrodes Absorption path length: 16-24 m Max pumping speed : 250 m3.h-1 Min. cathode temperature : 77 K

Spectroscopy of cationic molecules + + H3+ : + HN2+ : HCO+ : Synchrotron radiation Michelson interferometer New cell Gases Power supply Liquid nitrogen tank Pumping group Detector Experimental conditions : Observations (1800 – 3800 cm-1) Molecules H3+, HN2+ & HCO+ Resolution H3+ (0.015 cm-1), HN2+ & HCO+ (0.007 cm-1) Source Internal NIR source Detector InSb Beamsplitter KBr Windows CaF2 Iris H3+ (2.5 mm), HN2+ & HCO+ (1.7 mm)

H3+ Observation in the mid-Infrared Temperature dependance of the H3+ abundance See McKellar and Watson, J. Mol. Spec, 191, 215 (1998) Wavenumber (cm-1) Absorbance H3+ experimental details Acquisition time Detector Band observed Resolution Number of transitions Cathode temperature 45 min InSb 2 0.015 cm-1 28 77 K

Ro-vibrational spectra of HN2+ and HCO+ in mid-Infrared Protonation of neutral species : H3+ + X → HX+ + H2 X = N2, CO Experimental details (HN2+ and HCO+) Band Acquisition time Jmax Number of transitions Resolution 1 25 min 15 (HN2+), 14 (HCO+) 32 (HN2+), 29 (HCO+) 0.007 cm-1 HCO+ HN2+ Nakanaga et al., Chem.Phys. Lett., 169, 269 (1990) Amano, J. Chem. Phys. 79, 3595 (1983). 1st FT detection of the ν1 band of HCO+ ? Trot (HN2+ & HCO+) ≈180K

Pure rotational transition of HN2+ in the far-Infrared Acquisition 15-40 cm-1 HN2+ 0.0025 cm-1 Synchrotron radiation 1.6 K cooled Bolometer 50 µm Mylar Polypropylene 10 mm Poor S/N ratio First FT pure rotation 5 transitions recorded Good agreement with the literature R(J) J’ – J’’ Our work (MHz) Published frequencies (MHz) Difference (MHz) 7 8 - 7 745214(15) 745209.868(30)a 4.1 8 9 - 8 838300(15) 838307.1(10)b -7.1 9 10 - 9 931374(15) 931386.2(10)b -12.2 10 11 - 10 1024435(15) 1024443.2(10)b -8.2 11 12 - 11 1117481(15) 1117477.1(12)b 3.9 a Amano et al., J. Mol. Spec, 234, 170 (2005) b Verhoeve et al., Rev. Sci. Instrum., 61, 1612 (1990)

Attempt using Coherent Synchrotron Radiation… “coherent” : ITHz linear with Iring2 “ incoherent” : ITHz linear with Iring B. Billinghurst et al., Optics letters, 35, 3090 (2012) PhD J. Barros (2012) Barros et al., Rev.Sci. Instrum., 84, 033102 (2013) See talk WH15

Conclusion and perspectives Ion density : 1011 molecules.cm-3 Necessity to obtain higher density of ions ≠ cathode materials, new discharge geometry Improve the cooling system

Aknowledgements AILES Staff : S. Gruet, P. Roy (BML manager), L. Manceron, J. B. Brubach, M. Chapuis, F. Alabarse, S. Dalla Bernardina