Sponsored by: Dept. of Veterans Affairs Group #5 Samuel Rodriguez Daniel Thompson Chadrick Williams Giselle Borrero.

Slides:



Advertisements
Similar presentations
There are several research studies we would like to pursue with the HealthMonitor. These include long term monitoring of the elderly. We’re interested.
Advertisements

Team 4 Baby Peas “Pulse Early Alarm Sensor”
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Taylor Holmes, Jason Partin, William Rody, Malcolm Stagg.
EE 294 Master’s Project Spring 2006 D.A.S. Deaf Alert System By Robert Wangai Samer Ashkouri.
Robotics Club, Snt Council2 The 3 Schools of Robotics: Mechanical Design – Types of motors – Material selection –
Sponsored by: Dept. of Veterans Affairs Group #5 Samuel Rodriguez Daniel Thompson Chadrick Williams Giselle Borrero.
Gesture Controlled Car (GCC) By: Ashwaq Alkailany Reema Abubaker Supervised by: Dr. Luia Malhis.
Rotary Encoder. Wikipedia- Definition  A rotary encoder, also called a shaft encoder, is an electro- mechanical device that converts the angular position.
Pulse Oximetry Optional, AEMT.
Data Acquisition Risanuri Hidayat.
Team 03 Department of Electrical and Computer Engineering 20 November 2014 Digital Fitness Trainer MDR.
Unit 4 Sensors and Actuators
Wearable Wireless Physiological Sensors Daniel Bishop Rosy Logioia Josh Handley Gouri Shintri Phillip Hay Clay Smith Christina Hernandez Adam Stevenson.
Affective Computing Wearable Sensors Daniel Bishop Phillip Hay Christina Hernandez Adam Stevenson.
Team Impact Intelligent Helmet Impact System Preliminary Design Review January 29 th, 2008 Amanda Brodbeck Wei-Chu Liao Wei-Shen Liao Chris Mintle.
Senior Project Design Review Remote Visual Surveillance Vehicle (RVSV) Manoj Bhambwani Tameka Thomas.
Vibration & Temperature Sensor. Contents ■ Why monitor vibration? ■ Monitor a wide range of machines ■ Vibration measurements ■ Set alarm levels ■ Mounting.
V i t a l i s ECE Spring 2013 TEAM 13 Presenter: Yi Shen Wireless Biometric Sensor Team Members: Aakash Lamba Di Mo Shantanu Joshi Yi Shen Schematic.
Pulse oximetry is the noninvasive measurement of arterial blood oxygen saturation and heart rate. The Pulse Ox use a spectrophotometric probe. The pulse.
Team Members Jordan Bennett Kyle Schultz Min Jae Lee Kevin Yeh.
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
FALL DETECTION USING SMS ALERT. AIM  To find effective & timely fall of elderly and paralyzed patients using our fall detection method which is a combination.
Vibration & Temperature Sensor. Contents ■ Why monitor vibration? ■ Monitor a wide range of machines ■ Vibration measurements ■ Set alarm levels ■ Mounting.
A Mobile Wireless Electrocardiogram System for Health Care Facilities John Farner Jason Fritts Julian Jaeger Joe Richard Georgia Institute of Technology.
Optical Heart Monitor/Jump Drive Sponsor: Calit2 Mentor: Paul Blair Ph.D. Team: Matt Chandrangsu, Jeffrey Chi, Kari Nip ECE 191 – Group 6 Fall 2008.
Biomedical Engineering Solutions Amir Kamyabnejad Bobby Luk Chen Zhang Eric Boyer Yash Trivedi.
Portable Control & Measurement Device Supervisor: Boaz Mizrachi (Zoran)‏ Supervisor: Boaz Mizrachi (Zoran)‏
Team Members: Ruichen Zhao Xhoua Lor Jen-Yuan Hsiao John Marion.
©2008 Pearson Education, Inc., Upper Saddle River, NJ. All rights reserved. This material is protected under all copyright laws as they currently exist.
Melvin Rivera Suárez Project Manager Alexis Ortiz Pérez Rafael Vega Díaz Wilfredo Bermúdez Soto.
Embedded Stroke Evaluation System Amanda Sweeney, 4ECE Supervisor: Dr. Martin Glavin.
EWatch: A Wearable Sensor and Notification Platform Paper By: Uwe Maurer, Anthony Rowe, Asim Smailagic, Daniel P. Siewiorek Presenter: Ke Gao.
ICOM 5047 – Progress Report – The Smart Health Station November 2, Axel Vigo Josué Acevedo Pedro J. Franceschi Wilfredo Torres.
 “Zigbee is a suite of high level communication protocols using small, low power digital radios based on an IEEE 802 standard.”  Basically- short-range.
Analog to Digital Converter David Wallace English 314.
CSCI1600: Embedded and Real Time Software Lecture 14: Input/Output II Steven Reiss, Fall 2015.
PROJECT ALFRED THE BUILDING MASTER Group 6 Alec Seketa EE Ben Bush EE Brandon Becker EE Group 6 Alec Seketa EE Ben Bush EE Brandon Becker EE.
EE/CpE 180 Final Project Presentation Team 20 Child Locator Team Members Richard Bevins Jeremy Day Joshua Day Israel Hall Gary Shives.
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
Toshiba IR Test Apparatus Project Ahmad Nazri Fadzal Zamir Izam Nurfazlina Kamaruddin Wan Othman.
Group #15 Matt Frank Russell Geschrey.  This project was chosen because of an interest in wireless communication systems, namely BAN's (body area networks)
 ACCELEROMETER  TRANSMITTER- BLOCK DIAGRAM  RECEIVER- BLOCK DIAGRAM  COMPONENTS DESCRIPTION- ENCODER TRANSMITTER RECEIVER OPTICAL SENSOR.
Group #42: Weipeng Dang William Tadekawa Rahul Talari.
SmartCup – Team 42 Harington Lee, Chirag Patil, Arjun Sharma 1.
Multipurpose Keychain ECE 445 Senior Design Junting Lou Yaming Tang Lida Zhu TA: Rajarshi Roy Project No. 11 Fall 2012.
ARM and GPS Based Transformer monitoring system with area Identification Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
Walking Stick With Heart Attack Detection
박 유 진.  Short RF Range(~10m)  Reduce range by obstruction  Low data rate(1Mbps)  Normal Audio data rate : 1.5 Mbps  CD Quality Audio data rate :
TRANSMISSION LINE MULTIPLE FAULT DETECTION AND INDICATION TO EB
Final Report Yijie Xiao Project Title: Design and Development of a Continuous Monitoring System based on Wearable Devices Page 1.
1 Summary Lecture: Part 1 Sensor Readout Electronics and Data Conversion Discovering Sensor Networks: Applications in Structural Health Monitoring.
ECE445: Senior Design Spring 2015 Team 17: Weather Jukebox Sang Yun Bang, Thomas Fedrigon, Shanda Lu.
Modular Swimming Pace Aid ECE 445 Group Members: Igor Fedorov, Ryan Cook, Michael Chan Professor Carney (TA Ryan May)
Application Case Study Christmas Lights Controller
Instrumented Sensor Technology, Inc
AUTOMATED security system
System Network Structure
TEAM 2 – FALL 2006 PRESENTATION 1 LPM: Ahmad Omari.
CMS:Children Monitoring System
AUTOMATED security system
Hemodialysis Lecture 3.
Physiologic signals Lecture 5.
RAILWAY TRACK SNAP NOTIFICATION
GOLD (Glucose Optical LED Detector) Group 11
Digital Acquisition of Analog Signals – A Practical Guide
Conversation between Analogue and Digital System
Data Acquisition (DAQ)
ECE Computer Engineering Design Project
Measure 2 (Post Exercise)
Presentation transcript:

Sponsored by: Dept. of Veterans Affairs Group #5 Samuel Rodriguez Daniel Thompson Chadrick Williams Giselle Borrero

Hand Unit Chest Unit Waist Unit Thigh Unit

 Wireless monitoring pulse oximeter, blood oxygen concentration (SpO 2 ) and fall detection  Consists of four units ◦ Receiving Display unit (RDU) ◦ 3 Transmitting Sensor Units (TSU)  All units will be worn by the patient  Finger sensor will obtain pulse and SpO 2 and transmit  Chest and thigh sensor will determine patients posture information  Waist display will receive data, display data, and transmit emergency signals

 Ultimately to monitor patients for chronic heart and related health conditions  Remotely contact emergency services  Provide location to emergency services of patient  More affordable than existing wireless units  Ideal for a variety of users  Maximum protection at minimal to no cost

Transmitting Sensor Units (TSU)  To be worn on the finger, wrist, chest and right thigh  Battery powered  Control the pulse oximeter sensor  Make calculations to achieve pulse and oxygen concentration data  Determine the posture of the patient  Measure patient’s angular velocity and acceleration  Monitor unit’s battery life  Transmit data wirelessly to the waist unit (RDU) Receiving Display Unit (RDU)  Receive data wirelessly from TSUs  Display patient’s pulse and oxygen concentration  Contact emergency services  Monitor unit’s battery life  Audible and visual alerts for critical conditions, loss of signal and battery life, and display personal information

Non-invasive optical measurement of heart rate and blood oxygen saturation Hemoglobin is the red colored substance in blood and is the carrier of oxygen Red and infrared light are attenuated less by the body tissues and more by blood (600nm, 940nm) Light shines through finger and strikes a photodiode, which creates a very small current based on the amount of light incident on the photodiode This determine attenuation of light based on the output of the photodiode

 Sensor ◦ Generate alternating pulses of light at 600nm (red) and 940nm (infrared) ◦ Photodiode must detect light in the range of 600nm to 940nm ◦ Convert photodiode current to voltages values between 0V to 2.3V ◦ Accuracy of ±2% (70% - 100%) ◦ ±2 BPM for pulse  Transmit a maximum of 10 ft  MCU ◦ Two DACs 12-bits ◦ Three ADCs 12-bits ◦ 12 GPIOs

 To calculate pulse oximetry the photodiode current must be converted to a voltage  This voltage has both a DC and AC component that represents attenuation of light  DC-constant volume of blood used for auto gain control  AC – ebbing and flowing of blood used for measurements

 Control alternating pulses by pair of LED select lines (STG3155)  Common power lines  DAC controls current through system to avoid damage to LEDs

 Determine the patient’s position (sitting, standing or laying down)  Measure angular velocity and acceleration of patient  Have a range of ±6g acceleration.  Have an accuracy of angular velocity between ±300˚/s to ±500˚/s  Have a sampling rate of at least 120Hz

 Consist of: ◦ Two 3-axis gyroscopes (ITG-3200) ◦ Two 3-axis accelerometers (MMA7631L) ◦ One of each in the center of the chest and right thigh  MCU MSP430FG438 ◦ Three 12-bit ADCs ◦ 34 GPIOs  RF Transceiver CC1101

 RF transponder receives information from peripheral units  Multicontroller stores past data and makes decisions about patient status  16x2 LCD displays patient information, alerts, emergencies, or system status  Buzzer and LEDs provide visual and auditory stimulus for alerts

Part numberComponent size (mm 2 ) Number of I/O pinsExtra built-in features Cost ($) JN51488 x GHz transceiver, 12-bit ADC, 12- bitDAC, 4 wire audio interface 20 CC4309 x Sub 1GHz transceiver, 12-bit ADC, CC * MSP430F23312 X bit ADC2.50* MSP430F x 12 or 14 x14 48 or 6412-bit ADC, 12-bit DAC, DMA controller 5.85* MSP430FG43714 x bit ADC, 2x 12-bit DAC,3x Op Amps, Analog comparator, DMA, SVS, LCD driver 5.15*

 Separate unit from the MCU  Built-in display controller  May display pulse, blood oxygen content, patient’s name, or alarm information

 Green LED- Blinks if a fall is detected  Blue LED- Blinks if RDU loses signal from peripherals  Red LED- Blinks if emergency is active or user has indicated panic  Piezoelectric Buzzer- Pulses if emergency is active

 All units powered by a battery, through a DC/DC buck converter  2.5V supply to Gyroscope logic  3.3V supply to MCU, RF transceiver, and all sensor units  5V supply to LCD  Battery voltage monitored by built-in comparator in the MSP430FG43x

 3.3V output supplies MCU and sensors, and another buck converter supplies 5V for the LCD anode

 Analog to digital converter internal to MCU  Output to Red-Yellow- Green LED  Voltage divider from battery, scaled with the MCU’s maximum input voltage

 Language: C, JAVA  Testing: DevC++ V  Implementation: Code Composer Studio V , eclipse  Schematics: Cadsoft EAGLE V

MSP-FET430UIFEM430F6137RF900

Accurate, Fast Fall Detection Using Gyroscopes and Accelerometer- Derived Posture Information

 The linear acceleration and rotational rate of the chest and thigh for: ◦ Standing ◦ Walking ◦ Sitting ◦ Running

 Functions  The uses-permission function is needed in order to use Bluetooth features in any application. This is required to perform different types of communication such as requesting and accepting connections, and transferring data.  The mBluetoothAdapter function is needed for any and all Bluetooth activity. It represents the Bluetooth adapter, or Bluetooth radio, and is used for the entire system.  The REQUEST_ENABLE_BT function is to ensure that the Bluetooth is enabled. If the Bluetooth on the device is set off, this function prompts the user to enable Bluetooth through the system settings without stopping the application. <uses-permission android:name=“android.permission.BLUETOOTH”/>; mBluetoothAdapter = BluetoothAdapter.getDefaultAdapter(); startActivityForResult(enableIntent, REQUEST_ENABLE_BT);

 Functions  The startDiscovery() function searches and scans for other dvices. The scanning of devices takes about 12 seconds to complete and scans constantly.  The REQEST_CONNECT_DEVICE function is needed to actually connect to two devices. This is enabled by using the Bluettoth service socket which accepts a connection request and performs the connection.  The callIntent function allows the android application to make a phone call. The number is preset is this function. mBtAdapter.startDiscovery(); startActivityForResult(serverIntent, REQUEST_CONNECT_DEVICE); startActivity(callIntent);

Original budget Final Budget