1 Update on ELift™ SAGD artificial lift Presentation to Artificial Lift & Low-Pressure SAGD Subcommittees Nov 2004 Ken Kisman Ph.D., P.Eng. www.rangewest.ca.

Slides:



Advertisements
Similar presentations
PRESENTERS NDENGA D.L,ASSOCIATED BATTERY MANUFACTURERS,NAIROBI AND KILONZI F.M,MOI UNIVERSITY,ELDORET. APPLICATION OF PINCH TECHNOLOGY IN MINIMISATION.
Advertisements

SAND CLEANING STATFJORD C FIELD TEST Stavanger 18 – 19 January 2006 Henrik Dannström, MATOR AS.
Quiz – An organic liquid enters a in. ID horizontal steel tube, 3.5 ft long, at a rate of 5000 lb/hr. You are given that the specific.
A novel IGCC system with steam injected H2/O2 cycle and CO2 recovery P M V Subbarao Professor Mechanical Engineering Department Low Quality Fuel but High.
Oil and Gas Industry Presentation Activities, GHG Emission Sources, and Potential Reductions January 14, 2009.
Fluid Mechanics.
SAGD ELift Applications
TYPES OF MECHANICAL SYSTEMS
EFFECT OF DESIGN FACTORS ON THERMAL FATIGUE CRACKING OF DIE CASTING DIES John F. Wallace David Schwam Sebastian Birceanu Case Western Reserve University.
Basic Refrigeration Cycle
INTEGRATED PRODUCTION SERVICES Wellhead Management from Day 1 December 11, 2001.
GARP®Presentation ALRDC Seminar May 14 th, 2014 Daryl Mazzanti – Garp Services, LLC Wholly owned subsidiary of Evolution Petroleum Corp (EPM- NYSEMKT )
ENERGY CONVERSION ES 832a Eric Savory Lecture 12 – Large-scale plants Department of Mechanical and Material Engineering.
Vapor and Combined Power Cycles
9 CHAPTER Vapor and Combined Power Cycles.
Chapter 1 VAPOR AND COMBINED POWER CYCLES
Control and regulation of boiler operation Heat Engines & Boilers.
Types of Heat Exchangers
Spectrometer Solenoid Update Steve Virostek - LBNL MICE Video Conference #129 February 25, 2010.
Fluid Mechanics 06. Energy, Work and Power Work:- Work is force acting through a distance when the force is parallel to the direction of motion. Energy:-
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
COMMERCIAL REFRIGERATION
Heat exchangers The device at which heat exchange between two fluids at different temperatures and separated by a solid wall occurs is called heat exchanger.
Solar thermal energy Eng. Elamir Ahmed. Definition of solar thermal energy  Solar thermal energy is a renewable energy source.  Solar thermal uses technology.
WESTAR Oil & Gas Conference October 2008 Lori Bocchino Wyoming Oil & Gas Permitting and New Rule/Policy Revisions.
Presented by Sudiptya Banerjee
1 New Production Technologies for Lifting Liquids from Horizontal Wells Radius Energy, LLC May, 2015.
Multi-Stage Flash Desalination (MSF)
Drying Extra slides Mahmoud Teaima, Ph.D..
ME421 Heat Exchanger and Steam Generator Design Lecture Notes 6 Double-Pipe Heat Exchangers.
Heat Exchanger & Classification Prepared by: Nimesh Gajjar
Lecture 2 Single Phase Flow Concepts
The calculation methods of technological processes of underground heat extraction Alkhasov A., Alishaev M. (IGR DSC RAS) Matters of principle are considered.
EFFECTS OF THE VENUS GROUND AMBIENT ENVIRONMENT ON MATERIALS Principal Investigator: Linda Del Castillo Co-Investigators: James Polk, Michael Pauken, Elizabeth.
Chelsey Colvin Geothermal Energy What is Geothermal Energy? Geothermal energy is a renewable source of energy that barely does any damage to the environment.
CRYOGENICS FOR MLC Cryogenic Piping in the Module Eric Smith External Review of MLC October 03, October 2012Cryogenics for MLC1.
2003 ASME/API GAS-LIFT WORKSHOP Dual Gas Lift – EMEPMI Experience
Heat Exchangers Heat exchangers are used to transfer heat from one stream to another. They are used to heat streams and to cool streams. The streams can.
Lesson 13 CONVECTION HEAT TRANSFER Given the formula for heat transfer and the operating conditions of the system, CALCULATE the rate of heat transfer.
CMS FPIX Cooling System Studies Joe Howell, Fermilab for the FPIX Upgrade Mechanical Working Group CMS Upgrade Workshop April 27,
26 May 2010Hans Postema - CERN Status and plan for the development and construction of CO2 Cooling System for Pixel Upgrade 1.
Pressure-Enthalpy and the Variable Refrigerant Cycle
Convection: Internal Flow ( )
Solar Heating/Cooling/Dehumidifier Systems
He3 dilution refrigerator
Large Tonnage Chiller WC Screw.
CO2 cooling in CMS General overview 30 July 20101Hans Postema - CERN.
TC Straw man for ATLAS ID for SLHC This layout is a result of the discussions in the GENOA ID upgrade workshop. Aim is to evolve this to include list of.
ARTIFICIAL LIFT METHODS
Chapter Three Sections 3.1 through 3.4
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 8 Internal flow.
Introduction to Well Completions
A two-stage system for the future cooling system.
Professor Eduardo Cabrera
Gas Lift Design Philosophy for Subsea Developments 2001 European Gas Lift Workshop.
Target Systems and Monolith Design Update Rikard Linander Group Leader Monolith and Handling April 2, 2014.
Dewatering Flowlines with Foamers C. Passucci, K.C. Hester, A. di Lullo Flow Assurance: Ensuring Production Today, Creating Solutions for Tomorrow.
Cost Effective Offset Well Frac-hit Protection Solution
Michael A. Green and Heng Pan
Dynamics Seminar Section 7 Batch Reactors John Edwards, P&I Design Ltd
Enhanced Plunger Lift System plunger Lift for the 21st Century
Unit 42: Heat Transfer and Combustion
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
Heat Exchangers and Condensers
A PROPOSAL TO TRANSPORT FLUIDS FROM WELLHEAD TO FLOW STATION USING A GAS DISPLACEMENT PUMP. Juan Carlos Brown, 6th July 2017.
Lesson 24 NATURAL CIRCULATION
Process Equipment Design and Heuristics – Heat Exchangers
Mohr Separations Research, Inc.
Heat Exchangers Heat Exchangers.
Thermal Heavy Oil Recovery (THOR)
Presentation transcript:

1 Update on ELift™ SAGD artificial lift Presentation to Artificial Lift & Low-Pressure SAGD Subcommittees Nov 2004 Ken Kisman Ph.D., P.Eng.

2 Update on ELift Since my last presentation to the Artificial Lift Subcommittee on June 17, 2003: n An artificial lift paper was published in JCPT, August 2003 n A presentation was made to the 2004 Slugging it Out conference which is available at

3 Low-pressure SAGD summary Advantages (even in absence of thief zones): n Reduced heat requirements n Reduced emissions (Kyoto) n Less source water needed n Less facilities for steam generation & water treatment n Lower capital cost for piping & vessels n Improved operations (reduced H 2 S, CO 2, silica, scaling, & may eliminate sulphur plant) Disadvantages n Drilling of more well pairs initially although total number needed is approx. the same (or less) n Artificial lift may add extra cost (or reduce costs when surface fluid separators not needed)

4 Subcool Issues  Examples of Low-Pressure Challenges  Flashing to steam is triggered by a much smaller ∆P in the liner & up to the pump (eg 59 kPa versus 230 kPa)  Flowing bitumen viscosity is much higher (eg 61 cp versus 9 cp)  Higher mixed subcool for a given liquid head over a pump  Bitumen rates per well are lower so it is more important to optimize operations  Low subcool (ie vigorous lift) is particularly important at low pressure (for more details, see 2004 Slugging it Out presentation)

5 Cartoon showing how low subcool might increase steam chamber development along a well pair.

6 The next major SAGD advance The only way to be sure that bitumen rate, SOR, recovery factor, emissions & water use are optimized is  Use low-pressure SAGD  Use vigorous lift, with low subcool values, for extended periods

7 Concentric ELift configuration

8 Concentric ELift changes from parallel operation n Concentric inner & outer tubing are installed instead of parallel tubing strings n The outer tubing is insulated (substantially from the base to the port) n 1 st stage flow up to the port is between the outer tubing and the casing n The liquid pool flowing down to the pump is between the inner and outer tubing. n 2 nd stage flow to the surface is up the inner tubing. (parallel ELift operation is described in JCPT paper August 2003)

9 Advantages of Concentric ELift over Parallel ELift a)Can be installed in 9 5/8” intermediate casing b)Both configurations provide good performance at moderate flow rates but concentric ELift allows higher flow rates because flow area in 1 st stage can readily be larger c)Concentric option allows simpler wellhead, easier installation of tubulars, & more room for a pump & motor d)There is very little pressure drop across the packer

10 Concentric ELift simulation The QFlow** thermal wellbore simulator has been modified to allow SAGD simulation with concentric ELift as well as parallel ELift **Mike McCormack Fractical Solutions Inc

11 Concentric ELift simulation example 1 with QFlow

12 Concentric ELift simulation example 2 with QFlow

13 Concentric ELift tubing sizes Example configurations Casing od Insulated outer tubing od (id) Inner tubing od 9 5 /8”7 5 /8” (~6.0”)2 7 /8” 9 5 /8”7 ¾” (~6.5”)2 7 /8” 11 ¾”9 5 /8” (~8.0”)3 ½” 13 3 /8”10 ¾” (~9.0”)4 ½”

14 A downhole motor adds heat to fluids prior to pump intake Standard single-stage pump configuration  A downhole motor adds heat to the fluids prior to the pump intake and increases flashing ELift shroud option for motor  A shroud around the motor may be used so flow of the liquid pool cools the motor. This will cause the same heating of the pumped fluids but the high pump subcool provided by ELift will prevent flashing  Optionally insulate the section of 2 nd stage tubing from the pump to the elevation of the port.  Note the shroud benefits from liquid-only flow

15 ELift option can prevent heating of pumped fluids by a downhole motor ELift 1 st Stage Cooling Option for Motor  Motor does not have a shroud. A section of outer tubing at the elevation of the motor is left uninsulated so the motor is cooled by concentric flow up the 1 st stage.  Optionally, a heat transfer fluid can be used around the motor at base of tubing for increased thermal conduction to the outer tubing »eg commercial heat transfer fluids or liquid fusible alloys  Simulations show that the subcool at the pump inlet is almost unchanged by the use of the downhole motor. Hence, the full subcool benefit provided by ELift is maintained even with a downhole motor

16 Concentric ELift Simplest instrumentation configuration Pressure in liquid pool n An electronic pressure sensor string (attached to the pump cable) is landed above the pump. This enables control of the liquid level (by controlling the gas production rate at the surface) Liner temperature n A thermocouple string (attached to the pump cable) extends below the downhole motor to measure bottomhole heel temperature for (indirect) subcool measurement & control

17 Current ELift royalty rate $800 per well-pair per month

18 Artificial lift field pilot Need to demonstrate the following: COMBINATION of:  Low steam chamber pressures  Low mixed subcool  Long pump service life

19 Main overall ELift advantages  Improved recovery performance due to vigorous lift with low subcool in liner  Choice of pumps & the pumps have longer service life  Good downhole gas-liquid separation in each well