 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.

Slides:



Advertisements
Similar presentations
Research Techniques Made Simple: Flow Cytometry Richard R
Advertisements

Cell Culture Facilities and Equipment Presenter: Dr. R. Rahbarghazi.
1 2 3 * Flow = cells in motion * Cyto = cell * Metry = measure * Measuring properties of cells while in a fluid stream * Flow Sorting * Sorting (separating)
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Lasers in medicine: blood and blood flow in the tissues Today’s talk... 1.Introduction to blood and blood flow 2.Laser Flow-Cytometry (LFC) of blood...
Intro to Flow Cytometry James Marvin Director, Flow Cytometry Core Facility University of Utah Health Sciences Center Office Lab
CHAPTER 37 MLAB 1415 HEMATOLOGY JOANNA ELLIS, MLS(ASCP) Optical Light Scatter and Flow Cytometry.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
Introduction To Flow Cytometry:
Chapter 11 Cell Communication. Question?  How do cells communicate?  By “ cellular ” phones.  But seriously, cells do need to communicate for many.
Laser Anemometry P M V Subbarao Professor Mechanical Engineering Department Creation of A Picture of Complex Turbulent Flows…..
Optical Tweezers F scatt F grad 1. Velocity autocorrelation function from the Langevin model kinetic property property of equilibrium fluctuations For.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
Overview What is flow cytometry? Development of flow cytometry Components of Flow Typical applications Flow data.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
Flow Cytometry Basics James Marvin Director, Flow Cytometry Core Facility University of Utah Health Sciences Center Office Lab
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
PPT 206 Instrumentation, Measurement and Control SEM 2 (2012/2013) Dr. Hayder Kh. Q. Ali 1.
Agile - affordable - accurate Optical System and Measurement Technology Presentation.
Pharos university Faculty of Allied Medical SCIENCE Clinical Laboratory Instrumentation (MELI-201) Dr. Tarek El Sewedy.
Applications of flow cytometry in basic immunology Generation and characterization of DC Assays for T cell activation –Cell proliferation – Cell division.
FLOW CYTOMETRY Flow cytometry is a laser-based, biophysical technology employed in  cell counting,  cell sorting,  biomarker detection protein engineering.
Department of Biotechnology and Microbiology
Introduction to Flow Cytometry
Antigen antibody reactions
Flourescence Activated Cell Sorting
Practical molecular biology PD Dr. Alexei Gratchev Prof. Dr. Julia Kzhyshkowska Prof. Dr. Wolfgang Kaminski.
Structure and Function. Section 7-1  Prokaryotes  Eukaryotes.
Cell viability studies Sepideh Khoshnevis. The Goal To distinguish live cells from dead and apoptotic cells in order to calculate the the percentage of.
Journal Meeting Jung-Yun Ko DNA Sequencing & ABI DNA Sequencer.
How to evaluate the immune response and identify immunedeficit… Dr M.L. Romiti.
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Introduction To Flow Cytometry By Noha Kamel. Flow cytometry is a method of measuring multiple physical and chemical characteristics of particles by optical.
Dr Gihan Gawish Hydrodynamic focusing is a technique used to provide more accurate results from flow cytometers or Coulter counters for determining the.
Basic Principles in Flow Cytometry
Basic Principles, Instrumentation, and Practices
Flow Cytometry Principles & practice of “Fluorescence Spectroscopy in Biological Diagnosis & Research” Dr.Hekmatimoghaddam Assistant professor of pathology.
Advanced Biology Visualizing Cells. The Human Eye  Resolution – The minimum distance two points can be apart and still be distinguished as two separate.
FLOW CYTOMETRY  Definition: Measuring properties of cell as they flow in a fluid suspension across an illuminated light path.
Laser Flow Cytometry Forward Scatter indicates size Forward Scatter.
Flow Cytometry Basic Training. What Is Flow Cytometry? Flow ~ cells in motion Cyto ~ cell Metry ~ measure Measuring properties of cells while in a fluid.
Flow Cytometry (FCM) Yun-Ju Lee September 13, 2002.
1 Flow Cytometry in the Clinical Laboratory Patricia Aoun, M.D., M. P. H. Jean Bailey, MT-ASCP Kellie Neth, MT-ASCP The Nebraska Medical Center.
Flow Cytometry Becton Dickinson Asia Limited Company.
SCM 330 Ocean Discovery through Technology Area F GE.
A MEMS Micro Flow-cytometer Based on Dielectric Particle Focusing and Integrated Optical and Impedance Detection Peter R.C. Gascoyne Department of Molecular.
Antigen-Antibody Interactions: Selected Tests (Contd.)
Medical Laboratory Instrumentation (Blood cell counter) Third Year Dr Fadhl Alakwa UST-Yemen Biomedical Department.
Flow Cytometry. Applications FRET- protein interaction Membrane protein expression Intracellular protein expression Cell viability Ca 2+
Technology and methodology of pathology research Department of Pathology Peking Union Medical College Liang Zhi-yong West China School of Medicine Sichuan.
Identification of Cancer Stem Cells using Flow Cytometry Analysis تعيين الخلايا الجذعية السرطانية باستخدام تحليل التدفق الخلوي Dr. Ayat Al-Ghafari Biochemistry.
By c.Keerthana.  First described by Dutch physicist frits Zernike in  It is a type of light microscopy.  It is a contrast enhancing optical technique.
Indirect methods of cell counting
Flowcytometry.
Flow Cytometry FACS (Fluorescence-Activated Cell Sorter)
Spectrophotometer - Visible Type Spectro - photometer consists of two instruments : Spectrometer   Photometer  Spectrometer   for producing light.
TRENDS IN LABORATORY TESTING
FLOWCYTOMETRY.
Laboratory Techniques in Immunology
Flow Cytometry and Sorting Part 3
Wave Interactions.
Reticulocyte Detection
LIGHT MICROSCOPY variations
Optical measurement.
The Art of Flow Cytometry
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
S.varasteh 10/11/2012.
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Presentation transcript:

 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.

 When the laser beam strikes the stream, the majority of the photons will pass through unobstructed. Some of these photons will diverge slightly, primarily via light diffraction, from their path as they contact the membranes of passing cells.

 The result will be:  Forward scatter(FSC): is proportional to cell size; the bigger the cell, the more light is scattered.  Side scatter(SSC): is proportional to cell complexity; the more organelles inside the cytoplasm, the more light scatter.

1. liquid stream (sheath fluid) 2. a light source 3. filter or prism 4. detector and Analogue to Digital Conversion (ADC) system 5. a computer for analysis of the signals. Fl ow Ce ll La se r Be a m FS Sen sor Fluore scenc e Picku p Lens SS Se ns or FL 1 Se ns or 52 5B P FL 2 Se ns or 57 5B P FL 3 Se ns or 62 0B P FL 4 Se ns or 67 5B P 48 8D L 48 8B K 55 0D L 60 0D L 64 5D L

 No reagents or probes required (Structural) ◦ Cell size(Forward Light Scatter) ◦ Cytoplasmic granularity(90 degree Light Scatter) ◦ Photsynthetic pigments  Reagents are required. ◦ Structural  DNA content  DNA base ratios  RNA content ◦ Functional  Surface and intracellular receptors.  DNA synthesis  DNA degradation (apoptosis)  Cytoplasmic Ca++  Gene expression IntrinsicExtrinsic

 First, let’s talk about how the sample is delivered to the laser. It is important that particles or cells are passed through the laser beam one at a time. Most flow cytometers accomplish this by injecting the sample stream containing the cells into a flowing stream of sheath fluid or saline solution. The sample stream becomes compressed to roughly one cell in diameter. This is called hydrodynamic focusing.  As a cell passes through the laser, it will refract or scatter light at all angles. Forward scatter, or low- angle light scatter, is the amount of light that’s scattered in the forward direction as laser light strikes the cell. forward scatter is roughly proportional to the size of the cell.

 Light is quantified by a detector that converts intensity into voltage. In most cytometers, a blocking bar (called an obscuration bar) is placed in front of the forward scatter detector. As a cell crosses the laser, light is scattered around the obscuration bar and is collected by the detector. Small cells produce a small amount of forward scatter and large cells produce a large amount of forward scatter, the magnitude of the voltage pulse recorded for each cell is proportional to the cell size. If we plot a histogram of these data, smaller cells appear toward the left and larger cells appear toward the right.

 Light scattering at larger angles, for example to the side, is caused by granularity and structural complexity inside the cell. This side-scattered light is focused through a lens system and is collected by a separate detector, usually located 90 degrees from the laser’s path. The signals collected by the side- scatter detector can be plotted on one dimensional histograms like we saw for forward scatter.  A scatter plot using forward and side scatter data from a typical peripheral blood cell run. include lymphocytes which are small cells possessing low internal complexity; monocytes which are medium- sized cells with slightly more internal complexity, and neutrophils and other granulocytes which are large cells that have a lot of internal complexity.

 One of the most common ways to study cellular characteristics using flow cytometry involves the use of fluorescent molecules such as fluorophore-labeled antibodies the labeled antibody is added to the cell sample. The antibody then binds to a specific molecule on the cell surface when laser light of the right wavelength strikes the fluorophore, a fluorescent signal is emitted and detected by the flow cytometers The fluorescent light coming from labeled cells as they pass through the laser then it is directed through a series of filters and mirrors delivered to the appropriate detectors.  Fluorescence data is collected in generally the same way as forward and side scatter data. In a population of labeled cells, some will be brighter than others.  As each cell crosses the path of the laser, a fluorescence signal is generated. The fluorescent light is then directed to the appropriate detector where it is translated into a voltage pulse proportional to the amount of fluorescence emitted. All of the voltage pulses are recorded and can be presented graphically.

1. molecular biology 2. pathology 3. immunology 4. medicine (especially in transplantation, hematology, tumor immunology and chemotherapy, genetics and sperm, sorting in IVF). 5. plant biology

Flow Cytometry and sorting