C. Piemonte 1 Development of SiPMs a FBK-irst C.Piemonte FBK – Fondazione Bruno Kessler, Trento, Italy

Slides:



Advertisements
Similar presentations
New developments of Silicon Photomultipliers (for PET systems)
Advertisements

Liverpool Group presentation 22/07/2009
Development of scintillation detectors with MRS APD light readout for CBM Muon system and ECAL preshower Alexander Akindinov ITEP(Moscow) on behalf of.
A. Gola, A. Ferri, C. Piemonte, A. Picciotto, T. Pro, N. Serra, A
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Fiber-Optic Communications
Near-infrared (NIR) Single Photon Counting Detectors (SPADs)
Novel approach for calibration breakdown voltage of large area SiPM
Fiber Optic Receiver A fiber optic receiver is an electro-optic device that accepts optical signals from an optical fiber and converts them into electrical.
INAF - Osservatorio Astrofisico Catania II PRIN 2006 Meeting NEWS FROM SINGLE PHOTONS Sergio Billotta.
Chapter 6 Photodetectors.
Introduction on SiPM devices
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
Outline: Motivation for a backside illuminated SiPM (BID-SiPM)
Options for Dual-Readout Calorimetry in the 4 th Concept * (Light-Emitting) Active Media * (Photon-Sensing) Detectors * (Time-Domain) Signal Processing.
Detector development and physics studies in high energy physics experiments Shashikant Dugad Department of High Energy Physics Review, 3-9 Jan 2008.
Salvatore Tudisco The new generation of SPAD Single Photon Avalanche Diodes arrays I Workshop on Photon Detection - Perugia 2007 LNS LNS.
SiPM: Development and Applications
Development of front-end electronics for Silicon Photo-Multipliers F. Corsi, A. Dragone, M. Foresta, C. Marzocca, G. Matarrese, A. Perrotta INFN DASiPM.
Four Channels Data Acquisition System for Silicon Photomultipliers Mateusz Baszczyk, Piotr Dorosz, Sebastian Głąb, Wojciech Kucewicz, Łukasz Mik, Maria.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Silicon Photomultipliers and other advanced silicon sensors The INFN MEMS project R. Battiston INFN Perugia March 12th 2007.
An e.m. calorimeter on the Moon surface R.Battiston, M.T.Brunetti, F. Cervelli, C.Fidani MoonCal.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
SiPM technology at FBK C. Piemonte
Simonetta Gentile, LCWS10, March 2010, Beijing,China. G-APD Photon detection efficiency Simonetta Gentile 1 F.Meddi 1 E.Kuznetsova 2 [1]Università.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
10 th Pisa Meeting on Advanced Detectors, Isola d’Elba, May 2006 Development of the first prototypes of Silicon Photomultiplier at ITC-irst N. Dinu, R.
28 June 2007G. Pauletta: ALCPG Tests of IRST SiPMs G. Pauletta Univ. & I.N.F.N. Udine Outline 1.IRST SiPMs : baseline characteristics 2.first application.
Silicon Photo Multipliers as readout for the NA62 CEDAR Detector Silicon Photo Multipliers as readout for the NA62 CEDAR Detector The NA62 Collaboration.
Optical Receivers Theory and Operation
1 CPTA Center for Prospective Technologies & Aparatus ©2009 – Photonique SA (DMC) APD-Pixel Photo-Diodes for Frontier Detector Systems - GSI Darmstadt.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Solid State Detectors - Physics
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
SiPM from ST-Microelectronics Nepomuk Otte & Hector Romo Santa Cruz Institute for Particle Physics University of California, Santa Cruz
G. Zappala’ – Vienna Conference on Instrumentation 2016
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Update on works with SiPMs at Pisa Matteo Morrocchi.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Study of Geiger Avalanche Photo Diode applications to pixel tracking detectors Barcelona Main Goal The use of std CMOS tech. APD's in Geiger mode (that.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
12 th Pisa Meeting, Isola d’Elba, 25 May 2012 Politecnico di Milano, Italy New Development of Silicon Drift Detectors for Gamma-ray.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Fondazione Bruno Kessler Centre for Materials and Microsystems.
D. Renker, PSI G-APD Workshop GSI, PAUL SCHERRER INSTITUT Problems in the Development of Geiger- mode Avalanche Photodiodes Dieter Renker Paul Scherrer.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
Development of Multi-Pixel Photon Counters (1)
Electronics & Communication Engineering
Progress report on SiPM development and its applications
Characterization and modelling of signal dynamics in 3D-DDTC detectors
NUV-SiPM short technology description
First production of Ultra-Fast Silicon Detectors at FBK
Photodetectors.
Next generation 3D digital SiPM for precise timing resolution
Department of Physics and Astronomy,
The MPPC Study for the GLD Calorimeter Readout
Hamamatsu’s SiPM (MPPC) Characteristics and Latest Developments
Presentation transcript:

C. Piemonte 1 Development of SiPMs a FBK-irst C.Piemonte FBK – Fondazione Bruno Kessler, Trento, Italy

C. Piemonte Outline Important parameters of SiPM Characteristics of FBK-irst SiPMs Application of FBK-irst SiPM

C. Piemonte 3 - Gain - Noise - Photo-detection efficiency - Dynamic range - Time resolution General view of the important parameters in a SiPM

C. Piemonte 4 Gain = I MAX *  Q = (V BIAS -V BD )*  Q = (V BIAS -V BD )*C D __ ________ __ ____________ q R Q q q charge collected per event is the area of the exponential decay which is determined by circuital elements and bias. t i ~exp(-t/R S *C D ) ~(V BIAS -V BD )/R Q exp(-t/R Q *C D ) Gain number of carriers produced per photon absorbed

C. Piemonte 5 1 ) Primary DARK COUNT False current pulses triggered by non photogenerated carriers Main source of carriers: thermal generation in the depleted region. Critical points: quality of epi silicon; gettering techniques. NOISE 2) Afterpulsing: secondary current pulse caused by a carrier released by a trap which was filled during the primary event. 3) Optical cross-talk Excitation of neighboring cells due to the emission of photons during an avalanche discharge

C. Piemonte 6 PDE = N pulses / N photons = QE x P 01 x FF 1. QE Quantum efficiency is the probability for a photon to generate a carrier that reaches the high-field region. Maximization: anti-reflective coating, drift region location Photodetection efficiency 2. P 01. triggering probability probability for a carrier traversing the high-field to trigger the avalanche. Maximization: 1. high overvoltage 2. photo-generation in the p-side of the junction (electrons travel through the high-field region) 3. FF. Fill Factor “standard” SiPMs suffer from low FF due to the structures present around each micro-cell (guard ring, trench) micro-cell dead width

C. Piemonte 7 Time resolution Statistical Fluctuations in the first stages of the current growth: 1. Photo-conversion depth 2. Vertical Build-up at the very beginning of the avalanche 3. Lateral Propagation t=0 pair generation 0<t<t 1 drift to the high-field region t>t 1 avalanche multiplication * for short wavelength light the first contribution is negligible t1t1 t’ 1 single carrier current level the avalanche spreading is faster if generation takes place in the center

C. Piemonte 8 Development of SiPMs started in 2005 in collaboration with INFN. IRST: development of the technology for the production of SiPMs (large area devices/matrices) + functional characterization INFN (Pisa, Bari, Bologna, Perugia, Trento) : development of systems, with optimized read-out electronics, based on SiPMs for applications such as: - tracking with scintillating fibers; - PET; - TOF; - calorimetry FBK-irst SiPMs

C. Piemonte 9 n+n+ p Shallow-Junction SiPM 1) Substrate: p-type epitaxial 2) Very thin n+ layer 3) Polysilicon quenching resistance 4) Anti-reflective coating optimized for ~420nm p+ subst.  epi n+ [C. Piemonte “A new Silicon Photomultiplier structure for blue light detection” NIMA 568 (2006) ] IRST technology Drift region High field region p guard region

C. Piemonte 10 Layout: from the first design… (2005) SiPM structure: - 25x25 cells - microcell size: 40x40  m 2 1mm Geometry NOT optimized for maximum PDE (max fill factor ~ 30%)

C. Piemonte 11 … to the new devices (i) (2007) 1x1mm 2 2x2mm 2 3x3mm 2 (3600 cells) 4x4mm 2 (6400 cells) Fill factor: 40x40  m 2 => ~ 40% 50x50  m 2 => ~ 50% 100x100  m 2 => ~ 76% Geometries:

C. Piemonte 12 …to the new devices (ii) Circular: diameter 1.2mm diameter 2.8mm Matrices: 4x4 elements of 1x1mm 2 SiPMs Linear arrays: 8,16,32 elements of 1x0.25mm 2 SiPMs

C. Piemonte 13 IV measurement fast test to verify functionality and uniformity of the properties. Functional characterization in dark for a complete characterization of the output signal and noise properties (signal shape, gain, dark count, optical cross-talk, after-pulse) Photo-detection efficiency C. Piemonte et al. “Characterization of the first prototypes of SiPM fabricated at ITC-irst” IEEE TNS, February 2007 Tests performed at FBK

C. Piemonte 14 Leakage current: mainly due to surface generation at the micro-diode periphery Static characteristic (IV) Breakdown voltage Breakdown current: determined by dark events Very useful fast test. Gives info about: - Device functionality - Breakdown voltage - (Dark rate)x(Gain) uniformity - Quenching resistance (from forward IV) Reverse IV Performed on several thousands of devices at wafer level

C. Piemonte 15 Dark signals are exactly equal to photogenerated signals functional measurements in dark give a complete picture of the SiPM functioning Signal properties – NO amplifier Thanks to the large gain it is possible to connect the SiPM directly to the scope V BIAS SiPM 50  Digital Scope SiPM: 1x1mm 2 Cell: 50x50  m 2

C. Piemonte 16 Pulse gen. Laser Pulse area = charge histogram collection SiPM ~ns 1p.e pedestal. Excellent cell uniformity Linear gain Signal properties – NO amplifier

C. Piemonte 17 s = single d = double pulses a = after-pulse V BIAS SiPM 50  Digital Scope Pulses at the scope. Av 100x Signal properties – with amplifier A voltage amplifier allows an easier characterization, but attention must be paid when determining the gain

C. Piemonte 18 1x1mm 2 (400 cells) 4x4mm 2 (6400 cells) Let’s look at the electro-optical characteristics of these devices: Micro-cell size: 50x50  m 2

C. Piemonte 19 1x1mm2 SiPM - 50x50  m2 cell Signal shape Fast transient: avalanche current through parasitic capacitance in parallel with quenching res. Slow transient: Exponential recharge of the diode capac. through the quenching resistor Important to note: The value of the quenching resistor increases with decreasing temperature and so the time constant follows the same trend Set up: SiPM current signal converted into voltage on a 50  resistor and amplified with a wide-band voltage amplifier. Signal shape

C. Piemonte 20 1x1mm2 SiPM – 50x50  m2 cell Dark count Growing threshold T = -30C V BD = 27.2V From this plot we get idea of dark rate and optical cross-talk probability

C. Piemonte 21 1x1mm 2 SiPM - 50x50  m 2 cell Gain Dark count 2V overvoltage 3V overvoltage 4V overvoltage

C. Piemonte 22 4x4mm 2 SiPM - 50x50  m 2 cell 4x4mm 2 Signal shape 1mm 2 SiPM 16 x Dark Count of 1mm 2 SiPM -15C -25C -15C -25C Gain Dark count

C. Piemonte 23 4x4mm 2 SiPM - 50x50  m 2 cell Same conclusions as for the previous device: Excellent cell response uniformity over the entire device (6400 cells) Width of peaks dominated by electronic noise 28.6V 29.2V 29.6V T=-25C Vbd=27.6V Charge spectra when illuminating the device with short light pulses

C. Piemonte 24 Photo-detection efficiency (1)

C. Piemonte 25 Photo-detection efficiency (2) dark pulses light pulses DC curr with light DC curr. wo light

C. Piemonte 26 …what is the PDE of these devices? Measured on 1x1mm 2 SiPM using photon counting technique 50x50  m cell - ~50% fill factor 400nm Broad peak between 450 and 600nm 500nm 425nm 450nm

C. Piemonte 27 Laser: - wavelength: 400 or 800nm - pulse width: ~60fs - pulse period: 12.34ns with time jitter <100fs Filters: to have less than 1 photodetection/laser pulse SiPMs: 3 devices from 2 different batches measured Time resolution (1) G. Collazuol, NIMA, 581, , 2007.

C. Piemonte 28 Time resolution (2) Distribution of the time difference Timing performance (  ) as a function of the over-voltage

C. Piemonte 29 Microcell functionality measurement (measurement at RWTH Aachen)

C. Piemonte Measurement of microcell eficiency with a 5 um LED spot diameter Microcell functionality measurement

C. Piemonte Microcell functionality measurement

C. Piemonte 32 Some applications and projects in which we are involved

C. Piemonte 33 SiPM matrix – for PET (1) IV curves of 9 matrices of one wafer 1mm 9x16 IV curves Non working SiPM Uniform BD voltage Uniform dark rate First, small monolithic matrix of SiPM: Element 1x1mm 2 Micro-cell size: 40x40  m 2

C. Piemonte 34 Na 22 spectrum with LSO on a single SiPM (1x1mm 2, 40x40  m 2 cell) Res = 18% Tests are ongoing in Pisa (DASiPM project, A. Del Guerra) on these devices coupled with pixellated and slab LSO scintillators SiPM matrix – for PET (2) NEXT STEP: Larger monolithic matrices

C. Piemonte 35 Circular SiPM - 50x50  m 2 cell for CMS – Outer Hadron Calorimeter Muon response using SiPMs Muon response using HPD at 8kV package designed by Kyocera module with 18 SiPMs Each SiPM reads a bundle of 5 fibers 6mm 2 area SiPM

C. Piemonte 36 Array of SiPM for Fiber Tracking 32x array connected to ASIC designed for strip detectors => capacitive divider at the input to reduce signal Response uniformity under LED illumination INFN PG (R. Battiston) + Uni Aachen

C. Piemonte 37 HYPERimage project Seventh Framework programme, FP7-HEALTH-2007-A coordinator

C. Piemonte 38 HYPERimage project Development of hybrid TOF-PET/MR test systems with dramatically improved effective sensitivity First clinical whole body PET/MR investigations of breast cancer TOF-PET building blocks

C. Piemonte 39 The SiPM is going to play a major role as a detector for low intensity light, because of: - comparable/better proprieties than PMT; - the inherent characteristics of a solid-state det.. IRST has been working on SiPMs (GM-APDs) for about 3 years obtaining very good results in: - performance; - reproducibility; - yield; - understanding of the device. Conclusion