The current state of Confocal Scanning Laser Microscopy Hjalmar Brismar Cell Physics, KTH.

Slides:



Advertisements
Similar presentations
Part 1: The root of all evil Part 2: Fluorescence microscopy
Advertisements

Multiphoton and Spectral Imaging. Multiphoton microscopy Predicted by Maria Göppert-Mayer in 1931 Implemented by Denk in early 1990s Principle: Instead.
Multi-photon Fluorescence Microscopy. Topics Basic Principles of multi-photon imaging Laser systems Multi-photon instrumentation Fluorescence probes Applications.
Victor Sourjik ZMBH, University of Heidelberg
High Speed, Full-Spectrum Spinning-disk Confocal.
Flow Cytometric Analysis of FRET to Study the Interaction Between CFP- and YFP-Tagged Proteins David Stepensky.
Neurobiology, Optogenetics, and Optics Ravi Nath 2015/02/10.
Fluorescence Microscopy Wolfgang Graier F-actin NFkB (activation by H 2 O 2 ) Pictures: W.F Graier, MBC & MB, Graz, Austria.
Live cell imaging. Why live cell imaging? Live cell analysis provides direct spatial and temporal information Planning your experiment – The markers/fluorophores.
Biophotonics
Biology Mathematics Engineering Optics Physics Robotics Informatics.
Fluorescent Protein Reporters and Fluorescence Technology Josh Leung James Weis February 18th, 2010 Bio 1220, Gary Wessel.
Dave Piston May 18, 2014 Optical Sectioning 2: Confocal Designs and “Pseudo-confocals” Outline 1.PMT detectors 2.Laser Scanning Design Features 3.Pseudo-confocals.
Fluorophores bound to the specimen surface and those in the surrounding medium exist in an equilibrium state. When these molecules are excited and detected.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
Today’s Topic: Lec 3 Prep for Labs 1 & 2 3-D imaging—how to get a nice 2D Image when your samples are 3D. (Deconvolution, with point scanning or with Wide-field.
Multifocal two-photon laser scanning microscopy combined with photo-activatable GFP for in vivo monitoring of intracellular protein dynamics in real time.
Fluorescence microscopy – Principle and practical consideration Hiro Ohkura.
CALCIUM IMAGING Beata M. Wolska, Ph.D.
Kv2.1 membrane corrals: Novel regulators of K + channel function and trafficking Michael Tamkun Program in Molecular, Cellular and Developmental Neuroscience.
Chemical Structure of the Chromophore Biosynthesis of the Chromophore Critcial dehyrogenation reaction to juxtapose aromatic group with imidazlinone.
Live Imaging and Other Capabilities of the Bioscience Imaging Facility (BIF)
Confocal & Two-photon Microscopy. Contents 1.Two-Photon Microscopy : Basic principles and Architectures 2. Resolution and Contrast in Confocal and Two-Photon.
Biosensors for efficient capture of biological information Current technology relies on inefficient systems for capture of biological information: –Information.
Immunofluorescence Microscopy. Immunofluorescence Microscopy: When an antibody, or the antiimmunoglobulin antibody used to detect the antibody is labeled.
Dyes  Photostimulation: Channel Rhodopsin Caged glutamate (and others)  Ca 2+ sensitive  Voltage-Sensitive dyes  FRET, GRASP  Quantum Dots  Ultra-High-Resolution.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
Fluorescence Microscopy Chelsea Aitken Peter Aspinall.
Fluorescent proteins Green Fluorescence Protein (GFP) from jellyfish : Revolutionized medical and biological science by providng a way to monitor how individual.
Practical aspects of fluorescence microscopy
Chapter 3 History and Techniques of Cell Signaling.
Correcting confocal acquisition to optimize imaging of fluorescence resonance energy by sensitized emission Jacco van Rheenen Kees Jalink.
Are You FRETting? Find Out for Sure With FLIM Frequency Domain FLIM for Your Scope Intelligent Imaging Innovations.
FRET(Fluorescent Resonance Energy Transfer)
Fluorescence Techniques
- 1 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Guided tour through:  Configuration  Defining spectral range  Scan control.
Triplet Blinking - stable triplet state - S 1 T 1 due to solvent -halogens -transition metals Transition to the Dark Side.
Results Study of Carrier Dynamics in ZnSe Based Scintillators by Frequency Domain Lifetime Measurements J.Mickevičius, P.Vitta, G.Tamulaitis, A. Žukauskas.
Fluorescence Absorption of light occurs within ~ seconds, leaving a molecule in an excited state What happens next? –If no photon is re-emitted,
Last Class: Genetic Engineering 1. DNA labeling 2. Accurate Nucleic acid hybridization, Northern/Southern Blot, Microarray 3. Gene sequencing 4. Restriction.
BIO 224 Intro to Molecular and Cell Biology. Microscopes are tools frequently used in cell biology Type of microscope used depends on the specimen being.
Microscopy I Fluorescence Confocal Multiphoton Flow Cytometry By Luis Filgueira.
Powerpoint Templates Page 1 Powerpoint Templates Spectroscopic Microscopy.
Functional cellular imaging by light microscopy MICROSCOPIES.
Advanced Fluorescence & Confocal Microscopy 08/2007 Lecture by Dr. Dirk Lang Dept. of Human Biology UCT Medical School Room Phone:
- 1 - LSM 510 META AIM Carl Zeiss - PMLSM 510 META EF-Guided Tour April 2002 Guided tour through:  Configuration  Defining spectral range  Scan control.
Using and Analyzing Fluorescent Proteins Dina N Kovarik, MS, PhD. Digital World Biology. Updated September 11, 2014.
Molecular Cell Biology Light Microscopy in Cell Biology Cooper Modified from a 2010 lecture by Richard McIntosh, University of Colorado.
Confocal Laser Scanning Microscopy: general considerations and techniques Simone Bossi.
The Plasmamembrane and Lipid Rafts 08/2007 Lecture by Dr. Dirk Lang Dept. of Human Biology UCT Medical School Room Phone:
History of Fluorescent Proteins
IPC Friedrich-Schiller-Universität Jena 1 Radiationless excitation energy transfer requires interaction between donor and acceptor  Emission spectrum.
(Image: T. Wittman, Scripps) Principles & Practice of Light Microscopy 6 Special Techniques (FRET, FRAP, FLIP, FLIM, FCS, molecular sensors…)
Fluorescence and Fluorochromes Peter O’Toole Tel:
Date of download: 7/5/2016 Copyright © 2016 SPIE. All rights reserved. Spatial light modulator-two-photon microscope (SLM-2PM) scheme: (1) Ti:Sa laser.
Date of download: 7/7/2016 Copyright © 2016 SPIE. All rights reserved. The spectral overlap of Cerulean or mTFP with Venus is compared. The excitation.
Measurement Methods in Systems Biology
High Resolution Imaging Facility (HRIF)
Measuring Fluorescence Resonance Energy Transfer in vivo
Reliable and Global Measurement of Fluorescence Resonance Energy Transfer Using Fluorescence Microscopes  Zongping Xia, Yuechueng Liu  Biophysical Journal 
New Turf for CFP/YFP FRET Imaging of Membrane Signaling Molecules
Fluorescence Applications in Molecular Neurobiology
A Fluorescence Resonance Energy Transfer Sensor Based on Maltose Binding Protein Xianhui Li
Förster Resonance Energy Transfer (FRET)
Research Techniques Made Simple: Methodology and Applications of Förster Resonance Energy Transfer (FRET) Microscopy  Joshua A. Broussard, Kathleen J.
New Turf for CFP/YFP FRET Imaging of Membrane Signaling Molecules
The Art of Flow Cytometry
Asako Sawano, Hiroshi Hama, Naoaki Saito, Atsushi Miyawaki 
Imaging techniques for next generation plant cell biology.
Transition to the Dark Side
Presentation transcript:

The current state of Confocal Scanning Laser Microscopy Hjalmar Brismar Cell Physics, KTH

What are we doing in Cell Physics Confocal microscopy –History –Present Applications Areas of development –Excitation –Detection –Scanning

Cell Physics Study the biological cell from a physical perspective –Use tools and concepts from physics on biological problems –Develop methods and techniques –Describe biological functions and systems within a physical/mathematical framework We focus on: –Cell volume Osmolyte transport Water transport –Cell mass Measurement techniques Cell cycle/cell mass regulation –Intracellular signalling Frequency modulated Ca2+ signals

Instrumentation Microscopy (widefield, confocal, multiphoton) –Fluorescencent probes –Fluorescent labels, antibodies –Genetically engineered, GFP Electrophysiology –Patch clamp –MEA, multi electrode arrays

Confocal microscopy Marvin Minsky, 1955 –Laser (1958)1960 –Affordable computers with memory > 64kB –CSLM

WidefieldConfocal

Confocal evolution 1 st generation CSLM (1987) –1 channel fluorescence detection –50 Hz line frequency 2nd generation (commercial systems ca1990) –2-3 channel detection –>=100 Hz 3rd generation (1996) –4 channel detection –500 Hz 4th generation (2001) –32 channels –2.6 kHz –AOM, AOBS control

Confocal industry Carl Zeiss (physiology, dynamic measurements) Leica (spectral sensitivity) Biorad (multiphoton) (olympus) (nikon) (EG&G Wallac) …

Zeiss 510

Spectra Physics Millenia X - Tsunami

Leica TCS SP

Spectra Physics 2017UV

Applications - Techniques GFP –FRAP –FRET Multiphoton excitation

GFP- Green Fluorescent Protein Aequoria Victoria

GFP Discovered 1962 as companion to aequorin Cloned 1992, expression Aminoacids kDa Fluorophore made by 3 aminoacids (65-67) ”protected” in a cylinder

Dynamics GFP-Tubulin in Drosophila

Protein mobility – bleaching experiments Bleach mobile immobile FRAP – Fluorescence recovery after photbleaching

Variants of FP –Blue BFP –Cyan CFP –Green GFP –Yellow YFP –Red DsRed HcRed GFP timer CFP YFPCFP GFP

Fluorescence Resonance Energy Transfer FRET Spectral overlap Distance <10 nm DonorAcceptor

Interaction - FRET ( Fluorescence Resonance Energy Transfer) ProteinA CFP ProteinB YFP < 5-10 nm Excitation nm Emission >570 nm Donor Acceptor

FRET: NKA – IP 3 R

NKA – IP 3 R Donor GFP-NKA Acceptor Cy3-IP 3 R Before After Donor diff Photobleaching of acceptor removes FRET detected as increased donor signal Distance < 12 nm Ouabain binding to NKA shortens the distance – stronger interaction – increased FRET efficiency 15-25%

FRET based Ca 2+ sensor YFP CFP CaM 440 nm 480 nm YFP CFP CaM 535 nm 440 nm + 4 Ca 2+

Multiphoton excitation 1-photon 2-photon

Builtin confocality 1-photon 2-photon

PMT KonfokalMultifoton

 m 1-photon2-photon Better penetration (2-400  m) Enables measurements from intact cells in a proper physiological environment. Electrophysiology

FRET CFP-YFP multiphoton 790 nm 514 nm CFP – YFP separated by a 6 aminoacid linker Fluorochrome distance 5 nm YFP – Calcyon No excitation at 790 nm YFP excited at 880 nm

Development - Excitation Currently used lasers –Ar ion, 458,488,514 nm –HeNe 543, 633 nm –Ar ion 351,364 nm –ArKr 488,568 nm –HeCd 442 nm –Diode 405 nm –HeNe 594 nm –Multiphoton excitation, TiSa We need affordable, low noise, low power consumption lasers nm !

Development - Detection Spectral separation –Optical filters –Prism or grating Detectors –PMT –Photon counting diodes We need higher sensitivity, QE !

Development - Scanning Speed Flexibility

Ultrafast 3D spline scan Biological motivation –Ca2+ signals Measurement approach –Intracellular ion measurements –Combined electrophysiology

Frequency modulated Ca2+ signals

Data from live cell experiments combined with biochemical data is used as input for mathematical modeling-simulations [Ca 2+ ] Ca - wave Models verified by experiments can provide new information and direct the further investigations

Approach High resolution 3D recording of Ca2+ High speed recording Combined CSLM - electrophysiology Big cells – hippocampal pyramidal neurons

Scan speed

Confocal - line scan High time resolution (ms) Scan geometry  cell geometry 2D – cell cultures 2 s.

Arbitrary scan – 2D (Patwardhan & Åslund 1994)

2D specimen

Tissue – 3D cells

3D arbitrary scan x y z

Design criteria Z-axis precision >= optical resolution Bidirectional scan (to gain speed) Focusing distance um >100 Hz Nonharmonic

Ideas for ultrafast 3D scan Stage scan –High mass, impossible patch clamp Scan objective –Well defined mass, side effects in specimen ? Scan focusing lens inside objective –Tricky optics ?

Piezo focus with specimen protection 40X/0.9NA V/I