Linear Collider TPC R&D in Canada Bob Carnegie, Madhu Dixit, Dean Karlen, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer, Alasdair Rankin,

Slides:



Advertisements
Similar presentations
GEM Chambers at BNL The detector from CERN, can be configured with up to 4 GEMs The detector for pad readout and drift studies, 2 GEM maximum.
Advertisements

Cosmic Ray Test of GEM- MPI/TPC in Magnetic Field Hiroshima University Kuroiwa CDC Group Mar
Time Projection Chamber
The performance of Strip-Fiber EM Calorimeter response uniformity, spatial resolution The 7th ACFA Workshop on Physics and Detector at Future Linear Collider.
TPC R&D in Canada Dean Karlen / University of Victoria & TRIUMF Canadian LC-TPC Group:  Carleton University: Robert Carnegie, Madhu Dixit, Hans Mes, Kirsten.
D. Peterson, “Tracking Detector R&D at Cornell University and Purdue University” LC-TPC-LBL 18-Oct Tracking Detector R&D at Cornell University and.
Study of GEM-TPC Performance in Magnetic Fields Dean Karlen, Paul Poffenberger, Gabe Rosenbaum University of Victoria and TRIUMF, Canada 2005 ALCPG Workshop.
D. Peterson, “The Cornell/Purdue TPC”, LCWS05, Stanford, 21-March The Cornell/Purdue TPC Information available at the web site:
D. Peterson, Cornell University, “Tracking Detector R&D at Cornell University and Purdue University” ALCPG Arlington 09-Jan-2003 Tracking Detector R&D.
Beam test of Linear Collider TPC Micromegas module with fully integrated electronics * D. Attié, A. Bellerive, P. Colas, E. Delagnes, M. Dixit, I. Giamatoris,
D. Peterson, “ILC Detector Work”, Cornell Group Meeting, 4-October ILC Detector Work This project is supported by the US National Science Foundation.
D. Peterson, “The Cornell/Purdue TPC”, ALCPG, Snowmass, 23-August The Cornell/Purdue TPC Information available at the web site:
Position sensing in a GEM from charge dispersion on a resistive anode Bob Carnegie, Madhu Dixit, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer,
Linear Collider TPC R&D in Canada Madhu Dixit Carleton University.
D. Peterson, Cornell Univ., “Round table” 23-Jan-2003 Cornell Linear Collider Detector Research Cornell Interests: The Cornell group proposes to contribute.
D. Peterson, “Tracking Detector R&D at Cornell University and Purdue University” ALCPG SLAC 07-Jan Tracking Detector R&D at Cornell University and.
Readout of a TPC with the MEDIPIX2 CMOS chip as direct anode Saclay/DapniaP. Colas Y. Giomataris NIKHEFA. Fornaini H. van der Graaf J. Timmermans J. Visschers.
Update of Victoria TPC R&D Dean Karlen, Thanos Michailopoulos, Chris Nell, Paul Poffenberger, Gabe Rosenbaum University of Victoria and TRIUMF, Canada.
Astrophysics Detector Workshop – Nice – November 18 th, David Attié — on behalf of the LC-TPC Collaboration — Micromegas TPC Large.
An Overview of North American R&D in Gaseous Tracking Detectors for the LC Madhu S. Dixit TRIUMF & Carleton University International LC Tracking & Muon.
Carleton University A. Bellerive, K. Boudjemline, R. Carnegie, A. Kochermin, J. Miyamoto, E. Neuheimer, E. Rollin & K. Sachs University of Montreal J.-P.
IHEP, Bejing 9th ACFA ILC Physics and Detector Workshop & ILC GDE Meeting The preliminary results of MPGD-based TPC performance at KEK beam.
Measurement of MPGD-TPC resolution with charge dispersion in a beam test in a magnet Madhu Dixit TRIUMF/ Carleton University Canada A.Bellerive, K.Boudjemline,
ILD Large Prototype TPC tests with Micromegas D. Attié, A. Bellerive, P. Colas, E. Delagnes, M. Dixit, I. Giamatoris, A. Giganon J.-P. Martin, M. Riallot,
D. Attié CEA Saclay/Irfu RD51 – ALICE Workshop June 18 th, 2014 ILC-TPC Micromegas: Ion Backflow Measurements.
Chevron / Zigzag Pad Designs for Gas Trackers
GEM MINIDRIFT DETECTOR WITH CHEVRON READOUT EIC Tracking Meeting 10/6/14 B.Azmoun, BNL.
Snowmass, August, 2005P. Colas - Micromegas TPC beam tests1 A.M. Bacala, A. Bellerive, K. Boudjemline, P. Colas, M. Dixit, K. Fujii, A. Giganon, I. Giomataris,
Stanford, Mar 21, 2005P. Colas - Micromegas TPC1 Results from a Micromegas TPC Cosmic Ray Test Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay-
Resistive anode readout Stephen Turnbull CEA IRFU Saclay.
Orsay, January 12, 2005P. Colas - Resistive anode Micromegas1 Dan Burke 1, P. Colas 2, M. Dixit 1, I. Giomataris 2, V. Lepeltier 3, A. Rankin 1, K. Sachs.
Astrophysics Detector Workshop – Nice – November 18 th, D. Attié, P. Colas, E. Delagnes, M. Dixit, M. Riallot, Y.-H. Shin, S.
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
1 TRD-prototype test at KEK-FTBL 11/29/07~12/6 Univ. of Tsukuba Hiroki Yokoyama The TRD prototype is borrowed from GSI group (thanks Anton).
KLAUS DEHMELT EIC TRACKING R&D MEETING FEBRUARY, 2015 Charge Division Concepts February 09, 2015 Klaus Dehmelt 1.
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
FIRST TEST RESULTS FROM A MICROMEGAS LARGE TPC PROTOTYPE P. Colas (CEA Saclay), on behalf of the LC-TPC collaboration Micromegas with resistive anode:
GEM-TPC Resolution Studies ECFA/DESY LC Workshop Prague, November 2002 Dean Karlen University of Victoria / TRIUMF.
TPC PAD Optimization Yukihiro Kato (Kinki Univ.) 1.Motivation 2.Simple Monte Carlo simulation 3.PAD response 4.PAD response for two tracks 5.Summary &
Beijing, Feb.6, 2007 P. Colas - Micromegas TPC 1 Micromegas TPC studies in a 5 Tesla magnetic field with a resistive readout D. Attié, A. Bellerive, K.
Micromegas TPC Beam Test Result H.Kuroiwa (Hiroshima Univ.) Collaboration with Saclay, Orsay, Carlton, MPI, DESY, MSU, KEK, Tsukuba U, TUAT, Kogakuin U,
ILC TPC resolution studies with charge dispersion in MPGDs with a resistive anode Madhu Dixit Carleton University & TRIUMF IPNS KEK 14/05/2005.
June 22, 2009 P. Colas - Analysis meeting 1 D. Attié, P. Colas, M. Dixit, Yun-Ha Shin (Carleton and Saclay) Analysis of Micromegas Large Prototype data.
LC TPC R&D Results May Selected LC TPC R&D Results for the DESY RPC Meeting 2003 May 07 The LC TPC R&D Groups of the PRC R&D-01/03 Proposal Carleton,
Study of GEM Structures for a TPC Readout M. Killenberg, S. Lotze, J. Mnich, A. Münnich, S. Roth, M. Weber RWTH Aachen October 2003.
29/09/2010 1Wenxin.Wang_EUDET annual workshop D. Attié, P. Colas, M. Dixit, M. Riallot, YunHa Shin, S. Turnbull, W. Wang and all the LC-TPC collaboration.
Status of New TPC( Ⅱ ) Performance Study Yohei Nakatsugawa LEPS Meeting in Taiwan.
Phone meeting, December 20, 2005P. Colas - Resolution in BOS Micromegas TPC1 Resolution from the 1mm pads of the Berkeley-Orsay-Saclay Micromegas TPC Reminder:
IHEP, Beijing 9th ACFA ILC Physics and Detector Workshop & ILC GDE Meeting The preliminary results of MPGD-based TPC performance at KEK beam.
TPC Studies at University of Victoria ALCPG meeting SLAC, January 2004 Dean Karlen University of Victoria / TRIUMF.
Wenxin Wang 105/04/2013. L: 4.7m  : 3.6m Design for an ILD TPC in progress: Each endplate: 80 modules with 8000 pads Spatial Resolution (in a B=3.5T.
January 10, 2008MiPGD TPC resolution and gas1 Micromegas TPC addendum on measurements P. Colas, Saclay Lectures at the TPC school, Tsinghua University,
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Six modules Micromegas TPC beam test & Test bench 12/4/2012W.Wang_RD51 mini week1 D. Attié, P. Colas, M. Dixit, P. Hayman, W. Wang.
On behalf of the LCTPC collaboration VCI13, February 12th, 2013 Large Prototype TPC using Micro-Pattern Gaseous Detectors  David Attié 
Astrophysics Detector Workshop – Nice – November 18 th, David Attié — on behalf of the LC-TPC Collaboration — Beam test of the.
Development of high resolution Micro-Pattern Gas Detectors (MPGD) with wide readout pads Madhu Dixit TRIUMF & Carleton University Saha Institute for Nuclear.
1 TPC Meeting Institute of Physics, Academia Sinica Jia-Ye Chen
Charge Diffusion, and Resistive Films Method’s, Math's, Monty Carlo’s, and Track reconstruction (with an M...) By: Stephen Turnbull.
Durham, Sep 3, 2004P. Colas - Micromegas TPC1 Micromegas TPC Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay- Saclay cosmic setupReminder:
Performances of a GEM-based TPC prototype for the AMADEUS experiment Outline: GEM-TPC in AMADEUS experiment; Prototype design & construction; GEM: principle.
On behalf of the LCTPC collaboration -Uwe Renz- University of Freiburg Albert-Ludwigs- University Freiburg Physics Department.
Gaseous Tracker R&D ILC Detector Test Beam Workshop Fermi National Accelerator Laboratory January 17-19, Madhu Dixit Carleton University & TRIUMF.
Vienna Conference on Instrumentation – February 27, D. Attié, A. Bellerive, K. Boudjemline, P. Colas, M. Dixit, A. Giganon,
GEM TPC Resolution from Charge Dispersion*
Activities on straw tube simulation
Micromegas module for ILC-TPC
Recents Analysis Results From Micromegas TPC
TPC Paul Colas Technical meeting, Lyon.
Dan Burke1, P. Colas2, M. Dixit1, I. Giomataris2, V. Lepeltier3, A
Presentation transcript:

Linear Collider TPC R&D in Canada Bob Carnegie, Madhu Dixit, Dean Karlen, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer, Alasdair Rankin, & Kirsten Sachs Carleton University, University of Montreal, TRIUMF, & University of Victoria ECFA/DESY Prague - November 16, 2002

16/11/02M. Dixit2 Abstract In an ideal TPC, the limit to achievable spatial resolution comes only from diffusion. The traditional wire/pad TPC fails to meet this goal due to large ExB and track angle effects. While not hampered by such systematics, an MPGD readout TPC will achieve the ultimate diffusion limit of resolution if only the electron avalanche position could be accurately measured. We describe below our recent work on: i) measuring the limits to achievable GEM-TPC spatial resolution from gas diffusion by optimizing readout geometry; & ii) GEM test cell results on the possibility of improving position sensing in an MPGD from charge dispersion of avalanche charge on a resistive anode.

16/11/02M. Dixit3 ExB cancels track angle effect TPC wire/pad readout 100 µm Average Aleph resolution ~ 150 µm About 100 µm best for all drift distances Limit from diffusion  (10 cm drift) ~ 15 µm;  (2 m drift) ~ 60 µm 100 µm limit for all drift distances comes from wide pad response ExB & track angle systematics in a TPC (Aleph TPC example)

16/11/02M. Dixit4 An MPGD Readout TPC for the LC ExB and track angle systematic effects cannot be avoided in a wire/pad TPC Even when systematics cancel, the resolution is determined by the width of the pad response function (PRF) & not by physics of diffusion Large  (PRF) further limits the TPC 2 track resolving power Positive ion space-charge effects - additional complication A micro-pattern gas detector ( MPGD * ) readout TPC has -Negligible ExB (no preferred angles in an MPGD) -Natural suppression of positive ion space charge effects -Resolution and 2-track resolving power approaching diffusion limit Such as Gas Electron Multiplier (GEM), Micromegas

16/11/02M. Dixit5 MPGD-TPC R&D in Canada Study of limits to achievable diffusion limited resolution by optimizing readout geometry –15 cm drift TPC with GEM readout –Cosmic ray tracking studies The possibility of improving position sensing from charge dispersion in an MPGD with a resistive anode –GEM test cell results using collimated x-rays

16/11/02M. Dixit6 GEM-TPC studies 15 cm max. drift distance Gases: Ar CO 2 ; P10 TPC wire preamplifiers salvaged from Aleph 64 channels of 200 MHz FADCs built by U of Montreal New readout pad layouts: Trigger & veto pads with 3 fold multiplexing Tracking study: diffusion effects pad width effects on resolution track angle effect

16/11/02M. Dixit7 Cosmic ray test GEM-TPC

16/11/02M. Dixit8 New TPC pad layout for increased acceptance amplitudes color coded: 2 trigger + 4 veto Resolution study for central 2 & 3 mm wide pad rows Track fit 3 top + 3 bottom 2.5 mm wide pad rows 3-fold multiplexed

16/11/02M. Dixit9 Track fit in x-y 3 parameter track fit: x 0 (offset),   (angle),   (spread) Assume uniform line charge with Gaussian spread  Integral over pad ~ pad charge Compare to observed charge fractions in each row For now neglect ionization clustering along the track

16/11/02M. Dixit10 Determine Drift Velocity For Ar/CO 2 : v d ~ 8.3 µm/ns (E drift ~ 137 V/cm) For P10: v d ~ 50 µm/ns Drift-distance determined from drift-time: Adjust drift-velocity v d using straight tracks TPC length: 15cm

16/11/02M. Dixit11 Diffusion vs Drift Distance Fitted track width ~ charge cloud width from diffusion For P10 For ArCO 2

16/11/02M. Dixit12 From MC studies resolution depends only weakly on pad width if pad width is less than 4 times charge cloud size For short drift, charge cloud size ~ 500 µm Good resolution for 2 mm pad width Not so good for 3mm pad width Resolution Best resolution: ArCO 2, narrow pads, short drift, small |  |: 135  4 µm

16/11/02M. Dixit13 Resolution vs Drift Distance Best resolution for short drift ArCO 2 : Small diffusion 3 mm wide pads too wide P10: Large diffusion Less sensitive to pad width

16/11/02M. Dixit14 Resolution vs track angle Large track-angle effect possibly due to simplified track fit. Effect more pronounced for ArCO 2 with narrow pads

16/11/02M. Dixit15 Resolution vs Amplitude Resolution improves with electron statistics For very large number of electrons resolution degraded because of ionization from  -rays Effect is less pronounced with P10 gas

16/11/02M. Dixit16 Position sensing in a GEM from charge dispersion on a resistive anode (technique applicable to other MPGDs) Analogy:Analogy: position sensing in 1-D in a proportional wire by charge division Solution for charge density (L ~ 0) Telegraph equation (1-D): for simulation include finite charge cloud size + rise and fall time effects Deposit point charge at t=0 Telegraph equation in 2-D Position sensing in 2-D in an MPGD with a resistive anode Solution for charge density in 2-D

16/11/02M. Dixit17 Resistive anode GEM test cell setup

16/11/02M. Dixit18 Charge cluster size ~ 1 mm ; signal detected by ~7 anodes (2 mm width) An event in the resistive anode GEM test cell

16/11/02M. Dixit19 Width & shape of signal distributions on pads can be simulated The pad response function  PRF depends on anode resistivity & the gap between anode and readout pad plane This PRF is too wide Require  PRF ~  diffusion for optimum resolution Pad response function Simulation versus Measurement

16/11/02M. Dixit20 Design simulation for  PRF ~ 700 µm

16/11/02M. Dixit MΩ/  resistivity 100 µm gap 1.5 mm strips are too wide for  PRF ~ 700 µm! single event average central strip: main pulse adjacent strips with induced pulse + charge dispersion Resolution tests with  PRF ~ 700 µm design

16/11/02M. Dixit22 GEM charge dispersion resolution study 50 µm collimated x-ray spot Scan across 1.5 mm wide strips Record 1000 events with Tektronix digitizing scope Single event produces measurable signal on 3 strips Early charge pulse, delayed charge dispersion pulse Use 500 events to define pulse shape polynomials Measure signal amplitudes for remaining 500 events Compute 3 pad centre of gravity for each event Correct for bias in CG determination

16/11/02M. Dixit23 Polynomial fits define pulse shapes Use 500 events to define standardized pulse shapes for early charge pulse (left), and delayed charge dispersion pulse (right)

16/11/02M. Dixit24 Bias correction to centre of gravity

16/11/02M. Dixit25 Resolution near a strip edge  = 78 µm

16/11/02M. Dixit26 Resolution near the centre of a strip  = 61 µm

16/11/02M. Dixit27 Resolution between edge & centre  = 67 µm

16/11/02M. Dixit28 Resolution scan - summary Spatial resolution Position residuals X-ray spot position (mm)

16/11/02M. Dixit29 Outlook & summary Diffusion limited resolution ~ 140 µm in GEM readout TPC with 2mm wide pads (charge cloud width ~ 700 µm) for short distances Promising preliminary results for localization from charge dispersion –further tests with GEM test cell planned –Optimize parameters –Incorporate in the mini-TPC readout Cosmic tests FADC channels, no multiplexing Beam tests