A Novel Dermoscopic Probe for Determining Elasticity Measurements of the Skin Erica Bozeman 1, Markesha Cook 1, Stephanie Cruz 1 Advisor: Michael Miga,

Slides:



Advertisements
Similar presentations
12-CRS-0106 REVISED 8 FEB 2013 Experimental Results for a Novel Microwave Radiator Structure Targeting Non-invasive Breast Cancer Detection Arezoo Modiri,
Advertisements

1 Sixty-Four-Slice Computed Tomography of the Coronary Arteries: Cost-Effectiveness Analysis of Patients Presenting to the ED with Low Risk Chest Pain.
SCREENING FOR DISEASE Nigel Paneth. THREE KEY MEASURES OF VALIDITY 1.SENSITIVITY 2.SPECIFICITY 3.PREDICTIVE VALUE.
In the name of Allah. Development and psychometric Testing of a new Instrument to Measure Affecting Factors on Women’s Behaviors to Breast Cancer Prevention:
Characterization of Arterial Biomechanical Properties with Ultrasound for Coronary Heart Disease (CHD) Diagnostics Group 8 Laura Tanenbaum, Sam Tavakoli,
Colorectal Cancer Screening John Pelzel MD Sleepy Eye Medical Center.
Biomedical research methods. What are biomedical research methods? An integrated approach using chemical, mathematical and computer simulations, in vitro.
Giannis Combe Danilo Delgado Sara Patino FIU DEPARTMENT OF MECHANICAL ENGINEERING Miami, FL.
As noted by Gary H. Lyman (JCO, 2012) “CER is an important framework for systematically identifying and summarizing the totality of evidence on the effectiveness,
Breast Cancer Detection, Treatment, and Survival in Medicare and Medicaid Insured Patients Cathy J. Bradley, Ph.D. Professor of Health Administration Co-leader,
Laser Speckle Contrast System for Determination of Parathyroid Perfusion Gabriela Caires de Jesus, Tianhang Lu, Itamar Shapira, James Tatum, Yu Zhou Advisors:
The Effect of High Body Mass Index on the Prevalence of Lower Back and Hip Pain of Physical Therapy Patients Introduction The percentage of Americans who.
Mammography Screening Information for Providers Indian Health Service National GPRA Team.
A Novel Dermoscopic Probe for Determining Elasticity Measurements of the Skin Group 7: Erica Bozeman Markesha Cook Stephanie Cruz February 28, 2007.
Kenya Field Epidemiology and Laboratory Training Program (KFELTP)
FIBER OPTIC RS-OCT PROBE Team Members: John Acevedo Kelly Thomas Chris Miller Advisors: Dr. Patil Dr. Mahadevan-Jansen.
Biofeedback System for Propulsion Training February 22, 2007 Group Members: Noah Reding Nick Chadwick Tom Soike Project Sponsor: Dr. Mark Richter, MAX.
SPONSOR JAMES C. BENNEYAN DEVELOPMENT OF A PRESCRIPTION DRUG SURVEILLANCE SYSTEM TEAM MEMBERS Jeffrey Mason Dan Mitus Jenna Eickhoff Benjamin Harris.
Ken YoussefiENGR 10 D. T. Pham, S. S. Dimov, Rapid manufacturing, Springer-Verlag, 2001, ISBN: X, page 6.
Magnetic Resonance Electrical Impedance Mammography (MREIM) A new approach to breast cancer imaging Maria Kallergi, 1 John J. Heine, 2 and Ernest Wollin.
Cancer Incidence and Mortality in Massachusetts, Bureau of Health Statistics, Research and Evaluation Massachusetts Department of Public Health.
Evaluation of Primary Versus Secondary Prevention of Cervical Cancer: an evidence based literature review Jennifer Vestle, PA-S, John Carter, PhD Department.
SoftPAP® A Novel Collection Device for Cervical Cytology.
Neonatal Chest Compression Device Courtney Gallagher 1, Jillian Zeber 1 Advisors: Paul King 1, PhD; William Walsh 2, MD Vanderbilt University, Biomedical.
Nanocomposite Strain Sensors Christopher J. Tzanavaris.
Muscle Volume Analysis 3D reconstruction allows for accurate volume calculation Provides methods for monitoring disease progression Measure muscle atrophy.
Vanderbilt University Department of Biomedical Engineering  
CANCER INCIDENCE IN NEW JERSEY BY COUNTY, for the Comprehensive Cancer Control Plan County Needs Assessments August 2003 Prepared by: Cancer.
IMRT QA Plan Site 5%/3mm3%/3mm2%/2mm 0% noise1% noise2% noise0% noise1% noise2% noise0% noise1% noise2% noise HN
Blood Pressure Monitor Re-Calibration Lei Qu 1, Ross Hamilton 1,David Lee 1, Haniff Mohd Nor 2 Advisor: Dr. Andre Churchwell 3, Dr. Paul King 1 Acknowledgments.
A Glimpse of the Science Behind the American Cancer Society Access to Care Campaign Impact of Being Uninsured or Underinsured on Individuals with Cancer.
A Novel Dermoscopic Probe for Determining Elasticity Measurements of the Skin Group 7: Erica Bozeman Markesha Cook Stephanie Cruz November 14, 2006.
The Need Specification. References  Adapted from:  Design for Electrical and Computer Engineers, first edition, by Ralph M. Ford and Chris S. Coulston.
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. April 9, 2003.
Accessible Home Vital Signs Monitoring System Kristyn Eilertsen Adam Goodale Stephen Kepper Sunil Narayan Stacey Tarver Group 22 BME 272.
Modeling Cure Rates Using the Survival Distribution of the General Population Wei Hou 1, Keith Muller 1, Michael Milano 2, Paul Okunieff 1, Myron Chang.
DEVELOPEMENT OF A HOLISTC WELLNESS MODEL FOR MANAGERS IN TERTIARY INSTITUTIONS Petrus Albertus Botha Tshwane University of Technology Polokwane Delivery.
Advisor Client Justin Williams, PhD Department of BiomedicalEngineering University of Wisconsin-Madison Fredrick Kelcz, PhD, MD Department of Radiology.
Evaluation of Ergonomics of Data Entry System in Neonatal Intensive Care Unit John Fonge 1, Kendra Mills 1, and Brandy Scott 1 Advisor: Dr. William Walsh,
Handheld Flow Calibrator for Aerosol Observing System Jonathan Ma, Dung (Yung) Hoang Nguyen, Mario Zuniga Department of Mechanical and Aerospace Engineering,
Laser Treated Metallic Probes for Cancer Treatment in MRI Systems July 08, Advance Materials Processing and Analysis Center (AMPAC) Department of.
ETP GROUP 4 1. AHMAD FIRDAUS BIN MOHAMAD CATHERINE SIM MONG PHENG FAIMAIZE BIN IBRAHIM MUHAMMAD SYAWATUL EQWAN BIN MOHAMED SAPII.
Improving Performance of a Heavy Duty Engine Cooling Drive Through Reduction of Drag Losses Design Recommendations & Future Analysis CFD Analysis It is.
Additional Assessments. Clinicians are encouraged to communicate with the interprofessional team about other resources and next steps in terms of additional.
GEOGRAPHIC DISTRIBUTION OF BREAST CANCER IN MISSOURI, Faustine Williams, MS., MPH, Stephen Jeanetta, Ph.D. Department of Rural Sociology, Division.
A Novel Dermoscopic Probe for Determining Elasticity Measurements of the Skin Group 7: Erica Bozeman Markesha Cook Stephanie Cruz January 24, 2007.
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. February 12, 2003.
U N I V E R S I T Y O F S O U T H F L O R I D A “ Automated Signal Processing for Data Obtained for Core Body Temperature Measurements ” Undergraduate.
Current 3D imaging systems for brain surgery are too slow to be effective in an operating room setting. All current effective methods for demarcation of.
SKIN CANCER PREVENTION May Skin Cancer in Saskatchewan & Canada PART TWO.
Appendix 2 Comparison of screening from age 20 and age 25 Table of harms and benefits.
Date of download: 5/31/2016 From: Tipping the Balance of Benefits and Harms to Favor Screening Mammography Starting at Age 40 Years: A Comparative Modeling.
Hannah Weir, PhD Chunyu Li, MD, PhD Division of Cancer Prevention and Control Centers for Disease Control and Prevention, USA North American Association.
Fotlos Laspas'. Evangelia Sotiropoitlou'. Sophia Myhna^. Anita Manataki', Paraskevi TsagouW. Iris Tsangaridou', Loukas Thanos'
Material and Methods Patient Population. – From July 2005 through December 2008, 130 patients (130 procedures, 154 limbs, 185 lesions) were treated using.
Determine method of rapid prototyping or plastic extrusion to create prototype of true-to-scale catheter Determine optimal slot size without affecting.
Austin M. Luna and Mabel D’Souza
From: Tipping the Balance of Benefits and Harms to Favor Screening Mammography Starting at Age 40 YearsA Comparative Modeling Study of Risk Ann Intern.
IB Chemistry Internal Assessment.
VALUES OF ELASTOGRAPHY IN DIAGNOSIS OF THYROID CANCER
Natural Ceramic Membrane Filter for Water Purification
Robotic Needle End Arm Effector for Integration With CT Scan
L. A. den Otter. , R. M. Anakotta. , M. Dieters. , C. T. Muijs. , S
Measuring Caloric Intake Using Chewing Sounds
Breast Cancer Why Breastlight? Checkup Cycle Before Breastlight Checkup Cycle With Breastlight Product`s Features How to Use Breastlight? What to Look.
Breast Cancer Guideline Update – Sharp Focus on Who is at Risk
Patient engagement with digital therapeutic leads to reduction of A1C and costs in T2DM patients: Cost savings are correlated to both A1C drops as well.
The Burden of Cancer in Nova Scotia an evaluation of loss in expectation of life Ron Dewar Registry and Analytics Presented to the joint NAACCR.
Wojciech Glinkowski The prevalence of deforming dorsopathies (scoliosis, kyphosis and lordosis) in the population children and adolescents in Poland.
Presentation transcript:

A Novel Dermoscopic Probe for Determining Elasticity Measurements of the Skin Erica Bozeman 1, Markesha Cook 1, Stephanie Cruz 1 Advisor: Michael Miga, PhD Biomedical Modeling Laboratory 1 Department of Biomedical Engineering, Vanderbilt University Fabrication Circular, cylindrical and rectangular membranes casted and molded using liquid urethane rubbers, Vytaflex 10 and Vytaflex 60 Testing Average Dimensions (height x diameter) Indentation  Vytaflex 10: 3.6 x 36.6 mm  Vytaflex 60: 3.3 x 36.6 mm Compression  Vytaflex 10: 10.3 x 16.0 mm  Vytaflex 60: 14.5 x 16.0 mm Tests completed using the Bose Electroforce© Fabrication  Created a solid model file of device dimensions using SolidWorks software  Prototyped using a Z Corp. 3D Printer  Software “slices” file into thousands of thin layers  Physical model is built one layer at a time  Ink-jet print heads deposit binder into powder to create layers  Process repeated layer by layer Device Dimensions  S215 Force Sensor (l x w): 27.9 x 5.9 mm  Voice Coil: 26mm diameter Testing  Tensile stretching on rectangular phantom skin  Translational motion caused by voice coil  Force sensor reads forces created during stretch  MATLAB © used to determine the elastic modulus of the phantom skin based on the device’s measurement Our Device  Structural alterations present as differences in the skin elasticity which are potential indicators of the skin’s health.  We propose that skin lesion elasticity can be measured using a device which applies a mechanical force by stretching the skin. This device can be used in conjunction with biopsy to diagnose skin cancer.  Design a device that can safely stretch the skin by a few millimeters  Conduct skin phantom tests as a means of comparing measurements obtained from device and compare to literature values for normal and skin cancer moles.  Develop systematic method of measuring skin mechanical properties from device  Skin cancer is the most common form of cancer in the United States.  Observation of skin moles can help assess presence and progression of skin cancer  Types of skin cancer:  Melanoma: less common, higher mortality rate  Nonmelanoma: most common type of skin cancer, but low mortality  Skin cancer is 95% curable when detected early and treated. Disadvantages  Clinical Observationexperience dependent  Biopsycostly when overly used  Dermoscopytime consuming, expensive  Serial Photographytime consuming, expensive, specialized Skin Moles: Sizes: 2 mm – 2 cm Depth of melanoma: 1 mm - > 4 mm Color: pink to purple  The trend in new cases indicate that Americans over the age of 65 account for a large percentage of new cases (females 14% and males 22%), yet they make up only 5.5% of population.  Estimated total annual cost for treating NMSC was $426 million for Medicare population and $650 million for total US population.  The cost of treating cancer depends upon the stage of progression: advanced ($168,000), early ($1800), and screening ($700)  An efficient, user friendly device will be more accessible to general physicians and thus more accessible to the general public resulting in earlier detection for a wider range of the population. Problem Statement Objective Background Current Methods of Detection Figure 1. Atypical mole indicative of skin cancer. Market Potential Phantom Skin Experiments Device Validation Results Discussion Conclusion Future Work and Testing Acknowledgements Table 1. Calculation of the Elastic Modulus (kPa) of Vytaflex-10 and Vytaflex-60 using the Bose electroforce © to conduct independent testing. Independent Testing Results  We would like to give special thanks to Jao Ou, Stephanie Barnes, Dr. Paul King, Taya Furmanski, and John Fellenstein. Table 2. Forces (N) registered by the force transducer during the device testing. Table 3. Elastic Modulus (kPa) calculated using the aforementioned Matlab program. Independent Testing  Elastic modulus was determined for Vytaflex-10 ( kPa) and Vytaflex-60 ( kPa).  Testing supported literature’s claim of a six-fold difference between the modulus of materials. Device Testing  Matlab code closely simulated the dermoscopic probe and calculated a mean elastic modulus for Vytaflex-10 ( / kPa) and Vytaflex-60 (103 +/-21.5 kPa).  Testing showed the device’s sensitivity to the presence of an inclusion in the membrane  The test results demonstrates the dermoscopic probe’s potential for measuring the skin’s elastic properties. However, modifications are still required in order to increase the device’s efficiency.  Miniaturize probe and modify for use in clinical setting  Increase the transducer’s sensitivity  Moh’s surgery  Trials on in vivo skin membranes  Correlate the skin’s modulus to a certain health condition  A device which can decrease the cost of testing and increase the sensitivity of current testing methods has a high demand.  A lightweight, easily accessible, noninvasive method of testing skin lesions will increase patient comfort. Figure 3. Indentation mold with Vytaflex-10 and Vytaflex-60. Figure 4. Vytaflex-10 and Vytaflex-60 setup Figure 5. Bose Electroforce Figure 6. Compression Setup Figure 2. Cost of cancer treatment by location Figure 8. Our device prototype with the (A) voice coil and (B) force sensor. Figure 9(a). Simulation of dermoscopic probe using MATLAB © for the control phantom skin. Figure 9(b). Simulation of dermoscopic probe using MATLAB© for membrane with 1.0 cm mole. Figure 7. Our device SolidWorks file A BABA