15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.

Slides:



Advertisements
Similar presentations
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Advertisements

Fire Apparatus Pump Theory
DESIGN LAYOUT OF DISTRIBUTION SYSTEMS
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use various hose appliances and tools, prepare a test site for service.
How would you explain this on the 3394? If Fire Erupts on YOUR Boat If Underway, stop the boat Have everyone who is not wearing a PFD put one on Position.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
BS9990 : 2015 Updates and/or Changes
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
Pumping Apparatus Driver/Operator
Chapter 12 Systems and Equipment for Fire Protection.
LoneStar Fire Specialties
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
CVFD Training – Water Supply SFFMA Training Objectives: –
Fire Streams SFFMA Training Objectives: –
Unit 205: Cold water systems
Characteristics of Water
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Purpose of Standpipe and Hose Systems
Chapter 9 Water Supply.
CE HYDRAULICS ENGINEERING
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
Chapter 9 Water Supply.
Pumping Apparatus Driver/Operator
Basic Hydraulics Irrigation.
Introduction to Environmental Engineering Code No. (PE389) Lec. 5 and 6.
AccuMax Multi-Point Injection Mechanics
MODULE 7 Unload a Cargo Tank Motor Vehicle (CTMV).
Water Supply 1. Water Supply Components
Intermediate SFFMA Objectives: – Hrs received.
STEAM HEATING.
Module C Sprinkler systems (4-20)
Muhajir Ab. Rahim School of Mechatronic Engineering
Fire Hoses, Nozzles, Portable lighting, appliances, and ladders.
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Water Supply.
1. 2 Introduction We continue to develop new methods and materials for extinguishing fires Water still remains the primary extinguishing agent because.
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
3 Water. 3 Knowledge Objectives Describe the properties of water. Describe the three sources of water. Describe water’s role in extinguishing a fire.
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
Lecture 1 Water Distribution Systems
Water Supply Skill Drills.
Water Supply Firefighter II.
FVCC Fire Rescue Water Supply.
Chapter 33 Dam Construction. Objectives After reading the chapter and reviewing the materials presented the students will be able to: Give reasons why.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Firefighter III Module B Water Supply (4-19) (4-19)
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
Tanker Operations In Water Supply Michael Crawford July 2002.
Date: Monday, May 11 th 2015 Topic: Water Purification Objective: To recognize the stages of it.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Water supply definitions Water supply definitions Four Basic components of a water supply system Four Basic components of a water supply system Methods.
Water System Master Plan & Rate Study City of DeKalb, Illinois City Council Presentation May 16, 2015.
Video: Fire Hydrant Time: 1:01 Chap 14-1
CHAPTER 16 Water Supply. Fire Fighter I Objectives Describe the equipment and procedures that are used to access static sources of water. Describe the.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Fire Fighter Safety SCBA CHANGE/REFILL
National Diploma Mechanical and Electrical Services Construction Cold Water Supplies.
2010 Union County Water Movement Training Review Leesburg Twp. September 18, 2010.
Fire Service Pump Operator - 03 Water.
Water Supply (Fire Fighter I)
14 Refrigerant Recovery, Recycling, and Recharging.
2013Q1.
CTC 450 Review Water Processes.
RESIDENTIAL PLUMBING SYSTEMS (WATER SUPPLY)
WATER SUPPLY FOR NON-HYDRANT AREAS
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

15 Water Supply

2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe the features of a municipal water distribution system. Describe dry-barrel fire hydrants and wet-barrel fire hydrants. Discuss maintaining and testing a fire hydrant. Define static pressure, residual pressure, and flow pressure. Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Operate and shut down a fire hydrant. Unload and assemble a portable water tank. 15

3 Introduction An uninterrupted water supply is: –The primary weapon for extinguishment –Essential for fire fighter safety Ensuring a dependable water supply is a critical fireground operation and must be accomplished right away. Water sources include: –Municipal and private water systems –Static water sources –Mobile water supply operations 15

4 Municipal Water Systems Provide clean water for public use. Provide water for fire protection. Most are owned and operated by a local government agency. Systems includes a water source, a treatment plant, and a distribution system. 15

5 Water Sources Sources include: –Wells –Rivers or streams –Lakes –Reservoirs Many systems draw water from several sources. 15

6 Water Treatment Facilities Remove impurities All water must be suitable for drinking. Chemicals used to kill bacteria and harmful organisms. 15

7 Water Distribution Systems (1 of 3) Water mains deliver water from treatment facilities to the end user. Include pumps, storage tanks, and reservoirs Water pressure –Generally psi –Hydrant pressure should not drop below 20 psi. –Usually produced by pumps (directly or indirectly) 15

8 Water Distribution Systems (2 of 3) Water pressure may also be produced by gravity. –Gravity-feed system –Elevated water storage towers 15

9 Water Distribution Systems (3 of 3) Water mains typically follow a grid system. May have dead-end mains –Water enters from only one direction. –Limited available water supply –Multiple hydrants rob water from each other. Water main valves –Control valves: located throughout system to shut down sections –Shut-off valves: used to shut off water flow to individual customers and hydrants 15

10 Fire Hydrants Provide water for firefighting purposes Installed on both public and private water systems Consist of an upright steel casing attached to the underground distribution system 15

11 Dry-Barrel Hydrants Used in cold climates Hydrant valve is located at the base of the barrel and allows water to flow into the hydrant. Water flows into the hydrant only when it will be used. Opened by turning nut on top of hydrant 15

12 Draining a Dry-Barrel Hydrant If water is left standing, it may freeze. After each use, water drains out of barrel. When hydrant is fully open, drain is closed. When hydrant is fully closed, drain is open. Partially open hydrant allows water to escape under pressure. Causes erosion of soil around hydrant Reduces hydrant flow 15

13 Wet-Barrel Hydrants Used in locations where temperatures do not drop below freezing The barrel always has water in it. Each outlet is individually controlled. Additional lines can be added while water is flowing. 15

14 Location of Hydrants Located according to local standards and national recommended practices –Every 500' in residential areas; every 300' in high-value areas –Every intersection; mid-block when over set distances –Based on occupancy, construction, and size of the building 15

Inspecting and Maintaining Fire Hydrants (1 of 3) Check for visibility and access. Check for exterior damage. Ensure barrel is dry and free of debris. Ensure all caps in good working order. Open valve for water flow and remove debris. Shut down and ensure proper draining. Replace cap. 15

16 Inspecting and Maintaining Fire Hydrants (2 of 3) 15

17 Inspecting and Maintaining Fire Hydrants (3 of 3) To clean threads, use a steel brush. To remove burs on threads, use a triangular file. Replace cracked, broke, or missing cap gaskets. Lubricate as recommended by manufacturer. 15

18 Testing Fire Hydrants Fire-suppression companies are often assigned to test the flow from hydrants in their districts. Testing procedures are simple, but an understanding of hydraulics and attention to detail are required. 15

19 Flow and Pressure (1 of 2) Flow is the quantity of water moving through a pipe, hose, or nozzle measured by its volume, usually in gallons (or liters) per minute. Pressure is the energy level measured in pounds per square inch (psi) (or kilopascals). Static pressure: pressure when no water is moving –Measured by placing a gauge on a port with no water in the system moving 15

20 Flow and Pressure (2 of 2) Normal operating pressure: pressure during a period of normal consumption –Measured by placing a gauge on a port during a period of normal consumption Residual pressure: Amount of pressure that remains in the system when water is flowing Flow pressure: Measures quantity of water flowing through an opening during a hydrant test –Measured with a Pitot gauge 15

21 Hydrant Testing Procedure (1 of 2) Requires: –Two adjacent hydrants –Pitot gauge –Outlet cap with a pressure gauge 15 Place cap gauge on an outlet of first hydrant. Open hydrant valve and record pressure reading as the static pressure. At second hydrant, remove cap and open valve.

22 Hydrant Testing Procedure (2 of 2) Place Pitot gauge in stream and record as Pitot pressure. At the same time, record residual pressure at the first hydrant. Calculate or use look-up tables to determine flow. 15

23 Rural Water Supplies Residents of rural areas usually depend on wells or cisterns to provide water. No hydrants in these areas, so water must be obtained from other sources 15

24 Static Water Sources (1 of 2) Static sources include: –Rivers or streams –Lakes, ponds, oceans –Reservoirs –Swimming pools –Cisterns 15

25 Static Water Sources (2 of 2) Must be accessible to a fire engine or portable pump –Is there a road or hard surface within 20'? May have a dry hydrant permanently installed 15

26 Mobile Water Supply Apparatus Also known as tankers or water tenders Designed to carry water to the fire Generally carry 1,000- 3,500 gallons May be used to pump water directly into attack engine 15

27 Portable Tanks Carried on fire apparatus to be set up at the fire scene Typically hold 600-5,000 gallons of water Tankers are used to fill the portable tanks. The attack engine drafts from the tanks. Dump valves on the tankers allow them to off-load up to 3,000 gallons per minute. 15

28 Tanker Shuttles Used to deliver a large volume of water over a long period of time Number required depends on –Distance between fill site and fire –Time it takes to dump and to reload –Flow rate required at the scene Eliminate delays at fill site and dump site 15

29 Summary Municipal system has three components: water source, treatment plant, and distribution system. Hydrants may be wet-barrel or dry-barrel. Inspection of hydrants is needed annually. Testing is done to determine maximum flow availability. Rural water supply utilizes fill sites, tankers, and portable tanks. 15