ENE 490 Applied Communication Systems Lecture 3 Stub matching, single- and two-port networks DATE: 27/11/06.

Slides:



Advertisements
Similar presentations
RF Communication Circuits
Advertisements

ENE 428 Microwave Engineering
1 S Parameters and Power gains  Training in 1 day Roberto Antonicelli ST Belgium, Network Division.
Two-port networks Review of one ports Various two-port descriptions
Lecture 6. Chapter 3 Microwave Network Analysis 3.1 Impedance and Equivalent Voltages and Currents 3.2 Impedance and Admittance Matrices 3.3 The Scattering.
EKT241 – ELECTROMAGNETICS THEORY
UNIVERSITI MALAYSIA PERLIS
ELEC 412 -Lecture 171 ELEC 412 RF & Microwave Engineering Fall 2004 Lecture 17.
Fundamentals of Electric Circuits Chapter 19 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
ELEC 412Lecture 51 ELEC 412 RF & Microwave Engineering Fall 2004 Lecture 5.
ELCT564 Spring /2/20151ELCT564 Chapter 4: Microwave Network Analysis.
EKT 441 MICROWAVE COMMUNICATIONS
Instructor: Engr. Zuneera Aziz Course: Microwave Engineering
Microwave Engineering
Antennas and Propagation
IMPEDANCE Matching.
LECTURE 2. IMPEDANCE MATCHING
Chapter 5: Impedance Matching and Tuning
Microwave Amplifier Design Blog by Ben (Uram) Han and Nemuel Magno Group 14 ENEL 434 – Electronics 2 Assignment
ENE 428 Microwave Engineering
Lecture 8 Periodic Structures Image Parameter Method
Impedance Matching and Tuning
ENE 428 Microwave Engineering
EKT 441 MICROWAVE COMMUNICATIONS
EKT 441 MICROWAVE COMMUNICATIONS
Chapter 18 Two-port Networks.
5. Impedance Matching and Tuning
IMPEDANCE MATCHING IN HIGH FREQUENCY LINES UNIT - III.
CHAPTER 4 TRANSMISSION LINES.
12 Transmission Lines.
TELECOMMUNICATIONS Dr. Hugh Blanton ENTC 4307/ENTC 5307.
Block A Unit 3 outline One port network Two port network
Microwave Network Analysis
Fundamentals of Electric Circuits Chapter 19
1 RS ENE 428 Microwave Engineering Lecture 5 Discontinuities and the manipulation of transmission lines problems.
116/11/50 ENE 490 Applied Communication Systems Lecture 2 circuit matching on Smith chart.
Yi HUANG Department of Electrical Engineering & Electronics
 Power and power-gains are two main considerations in the design of a microwave transistor amplifier. To derive power and power-gains using traveling.
ENE 428 Microwave Engineering
1 EKT 441 MICROWAVE COMMUNICATIONS CHAPTER 1: TRANSMISSION LINE THEORY (PART III)
ENE 490 Applied Communication Systems
Chapter 4: Microwave Network Analysis
ENE 428 Microwave Engineering
EKT 441 MICROWAVE COMMUNICATIONS CHAPTER 3: MICROWAVE NETWORK ANALYSIS (PART 1)
Chapter 2. Transmission Line Theory
1.  Transmission lines or T-lines are used to guide propagation of EM waves at high frequencies.  Distances between devices are separated by much larger.
ENE 428 Microwave Engineerin g Lecture 10 Signal Flow Graphs and Excitation of Waveguides 1.
Prof. David R. Jackson Dept. of ECE Notes 14 ECE Microwave Engineering Fall 2015 Network Analysis Multiport Networks 1.
RF and Microwave Network Theory and Analysis
ELEC 401 MICROWAVE ELECTRONICS Lecture on Matching
ELEC 401 MICROWAVE ELECTRONICS Microwave Networks - Parameters
Lab2: Smith Chart And Matching
Smith Chart & Matching Anurag Nigam.
Chapter 10. Transmission lines
Microwave Engineering by David M. Pozar Ch. 4.1 ~ 4 / 4.6
ENE 429 Antenna and Transmission Lines
EKT 356 MICROWAVE COMMUNICATIONS
Microwave Engineering
ENE 429 Antenna and Transmission Lines Theory
Non-ideal property – crosstalk
topics Basic Transmission Line Equations
ENE 429 Antenna and Transmission lines Theory
ENE 429 Antenna and Transmission lines Theory
ENE 428 Microwave Engineering
Microwave Engineering
Voltage Reflection Coefficient
N-port Network Port reference Line Impedance Port Voltage & Current.
CHAPTER 59 TRANSISTOR EQUIVALENT CIRCUITS AND MODELS
ENE 428 Microwave Engineering
Presentation transcript:

ENE 490 Applied Communication Systems Lecture 3 Stub matching, single- and two-port networks DATE: 27/11/06

Review (1) Loaded quality and node quality factor –At each node of the L-matching networks, there is an equivalent series input impedance, denoted by R S +jX S. Hence a circuit node Q n can be defined at each nodeas –The relationship between circuit node Q n and loaded Q L is

Review (2)  By adding another element, T and Pi matching networks, more flexibility in designing Q L­ can be done.  The loaded quality factor of the match network is usually estimated as simply the maximum circuit node quality factor Q n.

Ex1 an extra T.L.s problem a) Find the load reflection coefficient, the input impedance, and the VSWR in the transmission line shown below. The length of transmission line is /8 and its characteristic impedance is 50 .

b) Evaluate V( /8), I( /8), V(0), I(0), and P(0).

c) Find the length in cm of the /8 T.L. at f = 1 GHz.

Design of a matching network with lumped and distributed components.  popular design  have large tuning capabilities but very sensitive to the placement of the capacitor along the transmission line. Even a small deviations result in drastic changes in the input impedance

Single-stub matching networks Consider matching networks that consists of series transmission line connected to a parallel open-circuit or short-circuit stub. a) short-circuit stub b) open-circuit stub

Procedures (1) 1. Consider Y Smith chart since the stub is connected in shunt with the circuit. 2. The normalized admittance of shunt stub is written in the form of y sc = jb s (b s > 0) for a capacitive susceptance and y sc = -jb s (b s > 0) for an inductive susceptance, the length of l 1 determines value of  jb s. The admittance y x is given by y x = y L + y sc = g L  jb s

Procedures (2) 3. Select b s such that y x is transformed to the admittance y in, y x and y in are on a constant  circle. 4. The length of series microstrip line l 2 is designed to change y x to y in. 5. If an open-circuit stub is used, the design procedure is quite similar except that the length l 1 is read starting from an open-circuited termination. (i.e., starting from y = 0)

Ex2 For a load impedance of Z L = 60 - j45 , design a single stub matching networks that transform the load to a Z in = 75 + j90  input impedance. Assume that both stub and transmission line have a characteristic impedance of Z 0 = 75 .

Single- and Two-port Networks The analysis can be done easily through simple input-output relations. Input and output port parameters can be determined without the need to know inner structure of the system. At low frequencies, the z, y, h, or ABCD parameters are basic network input-output parameter relations. At high frequencies (in microwave range), scattering parameters (S parameters) are defined in terms of traveling waves and completely characterize the behavior of two-port networks.

Basic definitions Assume the port-indexed current flows into the respective port and the associated voltage is recorded as indicated.

z Parameters v 1 = z 11 i 1 + z 12 i 2 v 2 = z 21 i 1 + z 22 i 2 or in the matrix form

y, h, and ABCD parameters y parameters h parameters ABCD parameters These two-port representations are very useful at low frequencies because the parameters are readily measured using short- and open- circuit tests at the terminals of the two-port network.

Two-port connected in series

Two-port connected in shunt

Two-port connected in cascade fashion

Disadvantages of using these parameters at RF or microwave frequency Difficult to directly measure V and I Difficult to achieve open circuit due to stray capacitance Active circuits become unstable when terminated in short- and open- circuits.

Introduction of scattering parameters (S parameters) 1. Measure power and phase 2. Use matched loads 3. Devices are usually stable with matched loads. S- parameters are power wave descriptors that permits us to define input-output relations of a network in terms of incident and reflected power waves

Introduction of the normalized notation (1) we can write Let’s define and

Introduction of the normalized notation (2) We can also show a(x) and b(x) in terms of V(x) and I(x) as and

Normalized wave generalization For a two-port network, we can generalize the relationship between b(x) and a(x) in terms of scattering parameters. Let port 1 has the length of l 1 and port 2 has the length of l 2, we can show that or in a matrix form, Observe that a 1 (l 1 ), a 2 (l 2 ), b 1 (l 1 ), and b 2 (l 2 ) are the values of in- cident and reflected waves at the specific locations denoted as port 1 and port 2.

The measurement of S parameters (1) The S parameters are seen to represent reflection and transmission coefficients, the S parameters measured at the specific locations shown as port 1 and port 2 are defined in the following page.

The measurement of S parameters (2) (input reflection coefficient with output properly terminated) (forward transmission coefficient with output properly terminated) (output reflection coefficient with input properly terminated) (reverse transmission coefficient with input properly terminated)

The advantages of using S parameters They are measured using a matched termination. Using matched resistive terminations to measure the S parameters of a transistor results in no oscillation.

The chain scattering parameters or scattering transfer parameters (T parameters) (1) The T parameters are useful in the analysis of cascade connections of two-port networks. The relationship between S and T parameters can be developed. Namely,

The chain scattering parameters or scattering transfer parameters (T parameters) (2) and We can also write